Search PubMed⌕ Search

Biomedical subjects

B J Grant

Publications and source records attributed to B J Grant.

At least 37 records · Page 2Linked to original sources

Pulmonary arterial elasticity in awake dogs.

We measured the relationship between pulmonary arterial pressure (Ppa), diameter (D), and length of a segment of the main pulmonary artery (MPA) in chronically instrumented conscious dogs breathing spontaneously (CCC). There were no physiologically significant changes in Ppa or D in the CCC dogs postoperatively, and the cross-sectional MPA shape measured by fast computed tomography was nearly circular. These results suggest that the MPA was not distorted by chronic instrumentation. We compared measurements made in the CCC dogs with previous measurements in acutely instrumented anesthetized dogs with open chests (AAO). The elasticity of MPA in the CCC animals was frequency dependent between 1 and 14 Hz and was similar to that in the AAO dogs. Oscillations of D preceded Ppa at cardiac frequencies in the AAO animals, but the D and Ppa oscillations were in phase in the CCC animals. The oscillations of length relative to D were significantly less in the CCC than in the AAO dogs. We conclude that, with limitations, the hemodynamic properties of the MPA can be measured in the CCC subjects. We suggest that the discrepancies between the AAO and CCC dogs can be attributed to differences in extrinsic loading of the MPA.

Animals↗

Compliance of the main pulmonary artery during the ventilatory cycle.

Transmural pulmonary arterial pressure (Ppa), diameter (D), and length (L) of a segment of the main pulmonary artery (MPA) were measured simultaneously in anesthetized open-chest dogs. The instantaneous volume was calculated from D and L. Pulmonary arterial elasticity for diameter (EpD) was calculated as the ratio of the amplitude of Ppa to D oscillation normalized by the mean D. Similar indexes were calculated for L (EpL) and V (Epv). Compliance per unit length was calculated from the dimensions and elasticity of the MPA. Under control conditions with 5 cmH2O positive end-expiratory pressure, EpD, EpL, and Epv at cardiac frequency were 175 +/- 27, 147 +/- 27, and 55 +/- 7 cmH2O, respectively. EpD increased with positive end-expiratory pressure, but EpL decreased and Epv was unaffected. EpD, EpL, Epv, and compliance per unit length were not significantly different between the start of inspiration and the start of expiration. In addition, there were no significant phase differences between the oscillations of Ppa and V at respiratory frequency. We conclude that the previously reported time variation of pulmonary arterial compliance during the ventilatory cycle is not due to time-varying properties of the MPA.

Animals↗

Flow-mediated vasodilatation of the main pulmonary artery.

This study compares the independent effects of flow (Qpa) and transmural pressure (Ppa) on the diameter (D) and length of a segment (L) of the main pulmonary artery (MPA) in anesthetized open-chested dogs. Qpa was increased by a shunt from the left lower lobe pulmonary artery to an external jugular vein. Ppa was increased with positive end-expiratory pressure (n = 5), or with a femoral arteriovenous shunt (n = 5). Mean Ppa, Qpa, D and L were calculated by averaging over a single cardiac cycle selected at end expiration of successive breaths. The independent effects of Ppa and Qpa on MPA dimensions were determined by multiple linear regression. The effects of Ppa delta D%/delta P% = 0.153 +/- 0.03 SE) and Qpa (delta D%/delta Q% = 0.021 +/- 0.004 SE) on D were similar in both groups of dogs. Changes of L (delta L%/delta Ppa% = 0.168 +/- 0.042 SE and delta Qpa% = 0.033 +/- 0.006 SE, n = 5) were similar to the corresponding changes of D. We conclude that the effects of flow are small relative to pressure and that flow not only causes vasodilatation but also vasoelongation of the MPA.

Animals↗

Time-varying pulmonary arterial compliance.

We tested the hypothesis that pulmonary arterial compliance (Ca) varies during the ventilatory cycle. Pressure and flow in the main pulmonary artery were measured in open-chest dogs under chloralose anesthesia (n = 12) with a positive-pressure volume-cycled ventilator. Input impedance was calculated from the pressure and flow waves of heart cycles obtained immediately after the start of inspiration (SI) and immediately after the start of expiration (SE). A lumped parameter model was used to calculate Ca from the input impedance spectrum of the main pulmonary artery. Three levels of positive end-expiratory pressure (PEEP) were used before and after meclofenamate (n = 6) or vagotomy (n = 6). Ca was significantly greater at SE than at SI at each level of PEEP. PEEP increased Ca at SE but not at SI. None of these changes was altered by meclofenamate or vagotomy, suggesting that these differences of Ca were due to passive mechanical effects rather than an active neurohumoral mechanisms. We conclude that Ca is time varying during the ventilatory cycle because it is altered by the dynamic increase of lung volume between SI and SE, but not with the quasi-static increase of lung volume induced by raising the level of PEEP. These changes of Ca were unaffected by vagal feedback or inhibition of cyclooxygenase. We suggest that the increased Ca just after the start of expiration may result from dynamic shifts of blood volume from the extra-alveolar to the alveolar vessels.

Animals↗

High-frequency oscillation during simulated altitude exposure.

Ventilatory requirements using high-frequency oscillation (HFO) during simulated altitude exposure were investigated in control dogs and animals with oleic acid-induced lung injury. FIO2 values of 0.21 and 1.0 were supplied by bias flow to the normal and injured dogs, respectively. After a control period, animals were exposed to a simulated altitude of 8,000 ft (barometric pressure 564 torr), followed by a second control period at ground level. Both experimental groups had similar values of PaCO2 at ground level and during exposure to reduced barometric pressure. The tidal volume necessary to maintain eucapnia was higher in oleic acid-injured animals compared with the control group; cardiac output and functional residual capacity were lower. The alveolar-arterial oxygen difference was substantially larger in the oleic acid group. Adequate gas exchange can be maintained with HFO during exposure to altitude provided that ventilation and inspired PO2 are not reduced below normobaric levels.

Altitude↗

In vitro posttranslational modification of lamin B cloned from a human T-cell line.

Autoimmune diseases are characterized by spontaneously occurring autoantibodies which have proven to be useful reagents for the characterization of specific nuclear proteins. Using a monoclonal autoantibody (72B9) derived from a murine lupus strain, we have cloned a cDNA from the human T-cell line MOLT-4, which encodes nuclear lamin B. The identity of the encoded protein as lamin B was established by both biochemical and immunological criteria. Inspection of the deduced amino acid sequence of lamin B revealed the presence in coil 1B of the alpha-helical domain of a leucine heptad repeat region. Analysis of mRNA in HL60 and MOLT-4 cells, which express only lamin B, or HeLa cells, which express all three major lamins (A, B, and C), together with the comigration of in vitro-translated product with isolated HeLa cell lamin B by two-dimensional gel electrophoresis, suggests that a single lamin B is expressed in mammalian somatic cells. In vitro translation with the cDNA clone revealed an EDTA-sensitive posttranslational modification which resulted in an increase in the apparent molecular weight to that equivalent to the native in vivo-synthesized lamin B protein. This in vitro modification included incorporation of a product of mevalonolactone and required an intact carboxy terminus.

Amino Acid Sequence↗

Effects of pulmonary vascular obstruction on right ventricular afterload.

We compared the effects of three forms of vascular obstruction: positive end-expiratory pressure (PEEP), ensnarement of the left main pulmonary artery (SN), and pulmonary thromboembolism (EMB) on right ventricular afterload. We measured right ventricular and pulmonary arterial pressures and flow in open-chested dogs under anesthesia (n = 8). Pulmonary artery input impedance (Zin) was calculated by Fourier analysis of the pressure and flow waves. Characteristic impedance (Zc) and pulmonary arterial compliance (Ca) were estimated from Zin with a lumped parameter model. Although PEEP, SN, and EMB all increased mean pulmonary arterial pressure, PEEP, had negligible effect on Zc and Ca, whereas SN increased Zc but decreased Ca (+24% and -49%, respectively), and EMB decreased both Zc and Ca (-33% and -39%, respectively). These changes of Zc affect wave reflection and alter the energy transmission ratio, which is the ratio of hydraulic power output in the measured and forward waves (Wm/Wf). Under control conditions, Wm/Wf was 62% and was not affected significantly by SN (59%) or by PEEP (46%), but it fell significantly to 30% after EMB. Simulation of these experiments in a mathematical model suggested that the increase of Zc with SN was due to an active neurohumoral effect; all other responses were consistent with passive mechanical effects. In additional experiments, we tested the effects of meclofenamate (n = 6) and ketanserin (n = 6) and of atropine and vagotomy (n = 5) on the response to SN and EMB. The serotonin antagonist, ketanserin, blunted the increase of Zc to SN, but none of the interventions significantly affected the response of Zc or Ca to EMB.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Role of molecular diffusion in conventional and high frequency ventilation.

The influence of molecular diffusion on gas-mixing during conventional mechanical ventilation (CMV) and high frequency ventilation (HFV) was studied by observing the wash-in of six poorly soluble, inert gases in arterial blood. Anesthetized dogs were ventilated either with CMV or HFV. Following a step change in inspired gas composition, the increase in arterial concentrations of hydrogen, helium, methane, ethane, isobutane, and sulfur hexafluoride was determined by gas chromatography. The relative gas diffusivities encompassed a range of almost one order of magnitude. Propane, present in inspired gas during both the control and wash-in phases, served as an internal reference for calculation of blood tracer concentrations. The wash-in of all six inert gases followed a single exponential time course during both CMV and HFV. The rate of wash-in of each gas decreased with increasing molecular weight (MW). The relationship of rate constants to a measure of relative diffusivity (MW-0.5) was significantly different than zero for both types of ventilation. The slope of this relationship was three times larger for CMV than HFV, indicating that molecular diffusion has a greater role in gas mixing during ventilation with large tidal volumes. Diffusion has a minor role in gas mixing during high frequency ventilation with small tidal volumes. Demonstration of the presence of gas separation secondary to molecular diffusion during HFV is enhanced by measuring wash-in, rather than wash-out, of inert gases because gas separation is likely to be obscured as exhaled gases pass through the well-mixed central airways during gas wash-out.

Animals↗

Optimization of routine transformation of Escherichia coli with plasmid DNA.

Methods to optimize resources and transformation efficiency of routine daily transformations of DH1 Escherichia coli prepared by three calcium chloride methods were investigated and compared with polyethylene glycol and Hanahan methods. The benefit of a heat-shock step, a preplating incubation step to allow expression of antibiotic resistance, use of log phase bacteria and prolonged storage of bacteria were investigated using pBR322 and pUC18 plasmid DNAs. Bacteria prepared by CaCl2 methods consistently gave efficiencies of 4 x 10(6) transformants/microgram of plasmid DNA or better and were overall the most labor- and resource-efficient methods. Use of log phase bacteria, a heat shock and an incubation step were found to be beneficial for freshly prepared bacteria for all methods. Prolonged storage of up to 30 days of bacteria prepared by the CaCl2 methods was beneficial, resulting in a sustained increase in transformation efficiency when selection was by ampicillin but not when by tetracycline resistance. Also found when using bacteria stored three days or longer was an increased transformation efficiency of stationary vs. log phase bacteria and an unchanged or even increased efficiency when the preplating incubation step was omitted. The Hanahan methods were the most labor and resource intensive and routinely gave efficiencies of 2 x 10(7). Higher efficiencies of 10(8) were obtained only with repeated trial and error and were not consistently reproducible. The polyethylene glycol method consistently gave efficiencies of 2 x 10(7), and bacteria could easily be prepared daily or frozen with a minimal decrease in efficiency.

Ampicillin Resistance↗

Effect of cardiac output on pulmonary hemodynamics.

The purpose of this study was to test the hypothesis that there is a direct relation between pulmonary arterial input resistance and compliance in seven anesthetized cats. Cardiac output was altered by varying the direction and flow through an arteriovenous fistula with a roller pump. Pulmonary arterial input impedance was calculated from the Fourier analysis of the pressure and flow waveforms. Input resistance, pulmonary arterial compliance and characteristic impedance were estimated from the impedance spectra with a lumped parameter model. We found that pulmonary arterial compliance increased with cardiac output (P less than 0.002) but characteristic impedance was independent of flow. The observed response has the effect of reducing the hydraulic power lost by the pulmonary vasculature due to wave reflection. In three additional cats we measured the diameter of the main pulmonary artery by sonomicrometry. We found a linear relation between mean pulmonary arterial pressure and pulmonary arterial diameter during alterations of cardiac output. This result suggests that the increase of pulmonary arterial compliance with cardiac output is due to geometric factors rather than changes in vascular elastic properties.

Animals↗

Dynamic response of local pulmonary blood flow to alveolar gas tensions: experiment.

The purpose of this study was to investigate the mechanism that causes a damped oscillatory response of local pulmonary blood flow to local hypoxia. The left lower lobe (LLL) of 10 anesthetized dogs was ventilated independently but synchronously with the rest of the lungs. Blood flow to the LLL as a proportion of total flow (QLLL/QT) was measured during the on-transient of the hypoxic response when LLL inspirate was changed from O2 to N2. There was a damped oscillatory response of QLLL/QT to hypoxia (34 of 40 trials). In contrast, the off-transient was always monotonic. There was no enhancement of the steady state or dynamic hypoxic response with repeated challenges. Local alveolar hypercapnia caused a damped oscillatory response in the presence of local hypoxia (15 of 20 trials), but there was no response in the presence of local hyperoxia. We conclude that 1) the dynamic pulmonary vascular response to O2 and CO2 are not additive because the response to CO2 is attenuated by hyperoxia and 2) the damped oscillatory response that occurs during hypoxia is the result of changes of local alveolar CO2 per se.

Animals↗

Effect of perivascular electromagnetic flow probes on pulmonary hemodynamics.

We determined the effect of perivascular electromagnetic flow probes (EMF) on pulmonary hemodynamics in acute experiments. In seven dogs placement of the EMF on the main pulmonary artery (MPA) increased pulmonary arterial pulse pressure by 25% (17.8-21.9 cmH2O, P less than 0.005) and mean right ventricular pressure by 12% (23.2-25.9 cmH2O, P less than 0.001) but did not alter heart rate, systemic blood pressure, mean pulmonary arterial pressure, or right ventricular end-diastolic pressure. This response was not abolished by local application of lidocaine to the MPA. In three cats input impedance was calculated from measurements of pressure and flow in the MPA. Impedance was calculated with flow measured using an EMF and ultrasonic volume flow probe (USF), which avoids the constraining effect of the EMF. When flow was measured with an EMF rather than a USF, there was a significant difference in the impedance spectra (P less than 0.001), but it was only apparent in the moduli greater than six harmonics. We conclude that the EMF does affect right ventricular afterload in acute experiments and alters the measured input impedance.

Animals↗

The effect of nasal flow on breathlessness in patients with chronic obstructive pulmonary disease.

Many patients with chronic obstructive pulmonary disease (COPD) receiving supplemental oxygen state that this treatment makes them less short of breath at rest. We postulated that this phenomenon may be related to improved arterial oxygenation, reduced ventilation, or stimulation of nasal receptors caused by the flow of gas. Eight patients who reported this phenomenon were studied in a quiet room. Each patient received zero flow, 2, or 4 L/min of air or oxygen through nasal cannula for 5 min at each level in random order in a single blind manner. At the end of each period, arterial blood gas composition was measured, and breathlessness was assessed with a visual analog scale. The scale was calibrated to read from zero (not at all breathless) to 100 (extremely short of breath). The entire protocol was repeated after application of topical lidocaine to the nasal passages. Results were assessed by analysis of variance. We found no significant effect of inspired oxygen concentration, gas flow, arterial oxygen tension, or arterial carbon dioxide tension on breathlessness. There was, however, a significant increase in breathlessness after nasal anesthesia from 44 +/- 3 SEM to 52 +/- 4 SEM (p less than 0.005). We suggest that the reduction of breathlessness in these patients by nasal oxygen is a placebo effect caused by wearing the nasal cannulas and is unrelated to gas flow or the increased arterial oxygen tension.

Administration, Inhalation↗

Characterization of pulmonary arterial input impedance with lumped parameter models.

The purpose of this study is to evaluate systematically the ability of lumped parameter models to approximate pulmonary arterial input impedance (Zin) and estimate characteristic impedance (Zc) and pulmonary arterial compliance (Cart). To assess goodness of fit, the parameters of each model were adjusted so that the model's impedance approximates the Zin measured in anesthetized cats. To assess the ability of the model to estimate Zc and Cart, the lumped parameter models were fitted to Zin calculated from a distributed parameter model of the feline pulmonary vasculature. In addition, we assessed the concordance between the lumped parameter model estimates of Zc and Cart. The results indicate that no one model was superior; any of four models would be a reasonable choice. A four-element model was used to compare Zin measured at different phases of the respiratory cycle. Small differences in the impedance spectra were found that have not been previously reported. We conclude that lumped parameter models can be used to provide close approximations to Zin, to estimate Zc and Cart, and to provide a useful approach for statistical comparisons of impedance spectra.

Computer Simulation↗

Air transportation of patients with acute respiratory failure: theory.

Adult respiratory distress syndrome (ARDS) that results from severe trauma often occurs in remote places, making it necessary to transport the patients to tertiary medical facilities by air. Since these severely hypoxic patients are exposed to additional risk of reduced inspired oxygen tension due to decreased barometric pressure, the feasibility of transportation of these patients was investigated by computer analysis. Mathematical models of pulmonary gas exchange in patients with ARDS were developed to calculate arterial and mixed venous blood tensions while breathing room air and oxygen at sea level, 8,000 ft, and 40,000 ft. Under each condition the following parameters were varied: alveolar ventilation (VA), cardiac output (Q), metabolic rate (VO2), hematocrit (Hcrit), and membrane diffusing capacity for oxygen (DmO2). Most of the gas exchange problems at altitude could be overcome by breathing oxygen as long as cardiac output and hematocrit were adequate. Hypoxemia in ARDS patients will not be greatly affected by the reduced inspired oxygen tensions at altitude in much the same way that hypoxemia in ARDS is poorly responsive to increased inspired oxygen tensions at sea level.

Aerospace Medicine↗

Ventilatory criteria for aeromedical evacuation.

Ventilatory requirements during simulated aeromedical transportation were investigated in normal dogs and animals with oleic acid-induced lung injury. Inspired oxygen fractions of 0.21 and 1.0 were used to ventilate the normal and injured dogs, respectively. Both groups were ventilated with a constant-volume piston ventilator. After a control period, animals were exposed to a simulated altitude of 8,000 ft (barometric pressure 564 mm Hg), followed by a second control period at ground level. Both groups of animals had no change in carbon dioxide production, arterial PCO2 or ventilation during exposure to reduced barometric pressure. Systemic blood pressure, heart rate, cardiac output, and lung volume were all lower in oleic acid-injured animals than controls; the alveolar-arterial oxygen difference was larger in the oleic acid group. With altitude exposure, arterial and mixed venous oxygen tensions were decreased in both groups. Adequate gas exchange can be maintained during exposure to altitude even in animals with abnormal function provided that ventilation is constant and the inspired oxygen fraction is increased to compensate for the reduced barometric pressure.

Aerospace Medicine↗

Adequacy of tissue oxygenation in intact dog intestine.

Changes in O2 consumption, O2 extraction, and intramural pH, resulting from a decreasing O2 delivery, were studied in the intact dog intestine. The O2 delivery was decreased by ischemia, hypoxia, and combined hypoxia-ischemia. A noninvasive approach for determining intramural pH based on the principle of tonometry was used. There was a strong correlation between the changes in intramural pH and intestinal O2 consumption as O2 delivery was decreased. Intramural pH and O2 consumption were initially maintained in the face of decreasing O2 delivery, but after a critical point they decreased. This critical point was 60.3 +/- 1.6% of base-line O2 delivery in the ischemic group and 51.3 +/- 2.7% of base line in the hypoxic-ischemic group. Despite a decrease to 36.0 +/- 5.6% of base-line O2 delivery, the intramural pH and O2 consumption did not decrease in the hypoxic group. O2 extraction increased with decreasing O2 delivery but did not plateau, indicating no diffusion limitation. The data suggest that blood flow is the major factor limiting intestinal O2 consumption. It is concluded that the noninvasive measure of intramural pH is a good marker of the adequacy of tissue oxygenation in canine intestine.

Animals↗

Dynamic response of local pulmonary blood flow to alveolar gas tensions: analysis.

It has been reported that left lower lobe pulmonary blood flow (Q) and alveolar CO2 decrease then oscillate in a progressively damped manner when the lobar inspirate is changed from pure O2 to N2. This damped oscillatory response of lobar Q is abolished by maintaining lobar CO2 constant. We set out to develop the simplest mathematical model that can simulate these experimental results by using techniques derived from control theory. Different models were tested. The simplest model that predicts the experimental data incorporates an exponential decrease of lobar Q to local alveolar hypoxia (time constant 3 min) and a damped oscillatory response of lobar Q to local alveolar hypocapnia. The response to hypocapnia has two components: a vasodilator effect possibly related to intracellular [H+] and a vasoconstrictor effect possibly related to changes of molar CO2. Both these components (time constants of 4.8 min) interact with each other by cross-coupled elements (time constants of 4.8 min). This model can be used to forecast results so that its validity can be tested by experiment.

Animals↗