Search PubMed⌕ Search

Biomedical subjects

B J Drew

Publications and source records attributed to B J Drew.

At least 37 records · Page 2Linked to original sources

Bedside diagnosis of myocardial ischemia with ST-segment monitoring technology: measurement issues for real-time clinical decision making and trial designs.

Monitoring of the ST segment is a valuable tool for guiding clinical decision making and evaluating anti-ischemia interventions in clinical trials; however, measurement issues hamper its diagnostic accuracy. This study reports the frequency and type of false positives and other measurement issues we have encountered during 12-lead ST-segment monitoring of patients in a cardiac care unit. Of 292 patients, 117 (40%) had one or more false positive events during an average of 41 hours of ST-segment monitoring, for a total of 506 false positive events. The 506 false positive events included 167 (36%) due to body positional change; 132 (26%) due to sudden increase in QRS complex/ST-segment voltage; 96 (19%) due to transient arrhythmia or pacing; 80 (16%) due to heart rate change in steeply sloped ST-segment contours; 26 (5%) due to a noisy signal; and 5 (1%) due to lead misplacement. It is concluded that many conditions in addition to myocardial ischemia can cause transient ST-segment deviation in patients with unstable coronary syndromes. Accurate ST-segment monitoring requires expertise in electrocardiogram interpretation, an understanding of the patient's clinical situation, and knowledge of the functions and limitations of the ST-segment monitoring system.

Aged↗

12-lead ST-segment monitoring vs single-lead maximum ST-segment monitoring for detecting ongoing ischemia in patients with unstable coronary syndromes.

BACKGROUND: 12-lead ECG monitoring of the ST segment is more sensitive than patients' symptoms for detecting ischemia after thrombolytic therapy or catheter-based interventions, but it is unclear whether monitoring of the single lead showing maximum ST deviation would be as efficacious. OBJECTIVE: To determine whether monitoring all 12 ECG leads for changes in the ST segment is necessary to detect ongoing ischemia in patients with unstable coronary syndromes. METHODS: Continuous 12-lead ST segment monitoring was performed in 422 patients from the onset of myocardial infarction or during balloon inflation in catheter-based interventions until the patient's discharge from the cardiac care unit. Computer-assisted techniques were used to determine (1) which lead showed the maximum ST deviation at the onset of myocardial infarction or during balloon inflation and (2) what proportion of later ischemic events were associated with ST deviation in this lead. RESULTS: The lead with the maximum ST deviation could be determined in 312 patients (74%). The remaining 110 (26%) had non-Q wave infarction without ST deviation or no ST changes during balloon inflation. During 18,394 hours of 12-lead ST monitoring, 118 (28%) of the 312 patients had a total of 463 ischemic events, 80% of which were silent. Of 377 ischemic events in which a maximum ST lead was detected, 159 (42%) did not show ST deviation in this lead (sensitivity, 58%; 95% CI, 53%-63%). Routine monitoring of leads V1 and II showed ST deviation in only 152 of the 463 events (sensitivity, 33%; 95% CI, 29%-37%). CONCLUSIONS: Monitoring of all 12 ECG leads for changes in the ST segment is necessary to detect ongoing ischemia in patients with unstable coronary syndromes.

Aged↗

Peak time of occurrence of myocardial ischemia in the coronary care unit.

BACKGROUND: The onset of acute myocardial infarction and sudden cardiac death has a circadian variation, with the peak occurrence between 6 AM and 12 noon. OBJECTIVES: To determine if a circadian variation exists for transient myocardial ischemia in patients admitted to the coronary care unit with unstable coronary syndromes. METHODS: The sample was selected from patients enrolled in a prospective clinical trial who had had ST-segment monitoring for at least 24 hours and had had at least one episode of transient ischemia. The 24-hour day was divided into 6-hour periods, and comparisons were made between the 4 periods. RESULTS: In 99 patients, 61 with acute myocardial infarction and 38 with unstable angina, a total of 264 (mean +/- SD, 3 +/- 2) ischemic events occurred. Patients were more likely to have ischemic events between 6 AM and noon than at other times. A greater proportion of patients complained of chest pain between 6 AM and noon than during the other 3 periods. However, more than half the patients never complained of chest pain during ischemia between 6 AM and noon. CONCLUSION: Transient ischemia occurs throughout the 24-hour day; however, ischemia occurs more often between 6 AM and noon. An important nursing intervention for detecting ischemia is continuous electrocardiographic monitoring of the ST segment, even during routine nursing care activities, which are often at a peak during the vulnerable morning hours.

Aged↗

Risk of thromboembolism in chronic atrial flutter.

Anticoagulant therapy is not conventionally used in the treatment of patients with atrial flutter. This recommendation has been based on sparse clinical experience, and recent preliminary reports suggest a significant risk of thromboembolism for these patients. A retrospective study was undertaken to assess the frequency of thromboembolic events as well as potential risk factors for these events in a cohort of patients with atrial flutter referred for radiofrequency ablation treatment. Eighty-six consecutive patients with a primary diagnosis of atrial flutter were evaluated. A history of embolic events was noted in 12 of 86 patients (14%) with atrial flutter, with an annual risk of approximately 3%. There were no differences in the prevalence of coronary artery disease, cardiomyopathy, valvular disease, or atrial fibrillation between the 2 groups of patients having an embolic event and those of patients without embolic events. Left ventricular function and left atrial size were also similar between the 2 groups. The only significant risk factor was hypertension (p < 0.05). However, in a regression model with other clinical variables (i.e., age, gender, left atrial size, presence or absence of any cardiac disease, length of time in flutter, left ventricular function, type of flutter, flutter cycle length, type of secondary arrhythmias) no significant predictors were found. Patients with transient ischemic attacks or pulmonary emboli were then excluded from the analysis in order to compare the thromboembolic risk in the present study to that reported in major atrial fibrillation trials. The overall risk becomes 7% (6 of 86), which over a mean follow-up period of 4.5 years yields an annual risk of approximately 1.6%. Although this risk is only 1/3 of that for patients with atrial fibrillation, this risk is higher than previously recognized for patients with chronic atrial flutter. Anticoagulant therapy should be seriously considered for these patients.

Adult↗

Comparison of standard and derived 12-lead electrocardiograms for diagnosis of coronary angioplasty-induced myocardial ischemia.

To determine whether a derived 12-lead electrocardiogram (ECG) would demonstrate typical ST-segment changes of ischemia during percutaneous transluminal coronary angioplasty (PTCA), 207 patients were monitored with continuous 12-lead ST-segment monitoring during angioplasty. Additionally, to compare the derived and standard ECGs during known periods of ischemia with PTCA balloon inflation, 151 patients were recorded with both electrocardiographic methods during the procedure. Of the 207 patients recorded with the derived ECG, 171 (83%) had typical ischemic ST-segment changes during PTCA balloon inflation. The amplitudes of these ST deviations were similar to those observed during transient myocardial ischemia observed in clinical settings (median peak ST deviation, 225 microV). There was agreement regarding presence or absence of ischemia in 150 of the 151 patients recorded with both derived and standard electrocardiographic methods (> 99% agreement). With use of the standard ECG as the "gold standard" for ischemia diagnosis, there were no false-positive results and only 1 false-negative result with the derived ECG. Furthermore, there was nearly perfect agreement between the two 12-lead methods in terms of anterior versus inferior wall patterns of ischemia. Future studies are required to determine whether continuous monitoring with a derived ECG would improve diagnosis and lead to better patient outcomes.

Adult↗

Frequency of disabling symptoms in supraventricular tachycardia.

The purposes of this study were to describe: clinical symptoms in a sample of consecutive patients with supraventricular tachycardia (SVT); incidence of sudden death, syncope, and other disabling symptoms; whether these symptoms differ by tachycardia mechanism; and to identify predictor variables of syncope in patients with SVT. Data were collected from chart reviews of 167 consecutive patients with SVT admitted for radiofrequency ablation. Three patients (2%) had nonlethal cardiac arrest, and a total of 16% (26 of 183) received at least 1 external direct-current shock for arrhythmia management. Twenty percent of subjects (33 of 167) reported at least 1 episode of syncope which was preceded by palpitations. The most frequent symptoms were: palpitations (96%), dizziness (75%), and shortness of breath (47%). We found atrioventricular nodal reentrant tachycardia (AVNRT) in 64 patients, atrioventricular-reciprocating tachycardia (AVRT) in 59, atrial tachycardia in 22, and atrial flutter in 22. The symptom profiles of patients with AVNRT, AVRT, and atrial tachycardia were very similar, but differed significantly (p <0.05) from those reported in the atrial flutter group. Multivariate analysis showed that heart rate > or = 170 beats/min was the only independent risk factor for syncope. Chi-square analysis demonstrated that SVT patients with heart rate > or = 170 beats/min had significantly more dizziness and syncope. Thus, despite a low incidence of associated heart disease, and good left ventricular function, there was a high frequency of disabling, potentially life-threatening symptoms associated with episodes of SVT in this sample. SVT can have potentially lethal consequences, and is more disruptive than previously thought.

Adult↗

Frequency, duration, magnitude, and consequences of myocardial ischemia during intracoronary ultrasonography.

To determine the frequency, duration, magnitude, and possible adverse effects of ischemia during intracoronary ultrasonography, real-time standard 12-lead electrocardiograms were recorded before, during, and after ultrasonography. Ischemia was defined as new-onset ST segment deviation of > or = 1 mm in one or more leads, measured at J + 80 msec. The magnitude of ischemia was expressed as the sum of absolute ST segment deviations across 12 leads. Eighteen (67%) of 27 patients had ischemia during intracoronary ultrasonography. The electrocardiogram resembled the characteristic pattern observed with occlusion of the vessel under study, involving ST segment elevation in contiguous leads in 89% of patients. A higher proportion of women (88%) had ischemia than men (58%), and women had smaller arterial lumenal areas compared with men (6.3 vs 9.1 mm2; p < 0.05). Individuals with ischemia were smaller than those without ischemia (body surface area = 1.99 vs 1.79 m2; p = 0.01). The mean duration of ischemia was 4 minutes and the mean 12-lead ST segment deviation score was 8.5 mm (maximum 20.5 mm). No patient with ischemia during ultrasonography had complications. Ischemia is common during intracoronary ultrasonography, particularly in women and individuals with smaller vessels; however, no adverse outcomes occur as a result.

Aged↗

Computer versus manual measurement of ST-segment deviation.

Total ST scores (sum of absolute deviations in all 12 electrocardiographic [ECG] leads) have been used for research purposes to estimate total ischemic burden and to predict reperfusion after thrombolytic therapy. Computerized monitoring systems are capable of measuring ST deviation to the 10-microV level, whereas humans are incapable of such precise resolution. The purpose of this study was to compare computer versus manual ST scores in 12-lead ECGs exhibiting ischemia and to compare interrater reliability of manual measurements between two experts. A total of 58 subjects with 100 microV or more ST deviation in one or more leads during percutaneous transluminal coronary angioplasty balloon inflation were selected for analysis. ST measurements were made at J + 80 ms, using the isoelectric line as a reference, and summed across all 12 leads. Manual measurements were made to a minimum of 50 microV by two independent reviewers blinded to the computer scores. Total ST scores were compared using paired t-tests, and Pearson coefficients were used to test the correlations. A high correlation was observed between the manual and computer measurements (r = .96, P < .00) and between the two reviewers (r = .96, P < .00). A high degree of interrater reliability is possible with manual measurements of ST deviation. Computer measurements are consistently greater than manual measurements, presumably because humans "round down" to the nearest 50 microV. As such, computers may detect ischemia that is missed by humans. However, computer and manual measurements of ST deviation should not be mixed when used as a variable for research.

Electrocardiography, Ambulatory↗

Body position effects on the ECG: implication for ischemia monitoring.

Rotation of the heart in relation to surface electrocardiographic (ECG) electrodes when a patient turns to one side has been reported to cause ST-segment shifts, triggering false alarms with continuous ST-segment monitoring. We prospectively analyzed ST-segment and QRS complex changes in both standard and derived ECGs in 40 subjects (18 with heart disease and 22 healthy) in supine, right- and left-lying positions. Of the 40 subjects, 6 (4 cardiac, 2 healthy) developed positional ST deviations of 1 mm or more on the standard ECG. In the derived method, five of the same six subjects showed ST-segment deviation of which most occurred in the left-lying position. Positional ST changes were most frequent for males and for cardiac patients (33%). Changes in QRS complex morphology were common on the standard (28 of 40, 70%) and less frequent on the derived ECGs (17 of 40, 43%), occurring in both healthy and cardiac subjects. QRS axis changes occurred only on the standard ECG. It was concluded that (1) right and left side-lying positions frequently induce clinically significant ECG changes; (2) positional ST-segment deviation is less frequent than previously reported and is most likely to occur in males with cardiac disease; and (3) the derived method is less prone to positional QRS changes than the standard ECG.

Adult↗

Estimating ischemic burden: comparison of two formulas.

BACKGROUND: Complex formulas based on elevations of the ST segment on the ECG allow noninvasive estimation of ischemic burden. However, the formulas require elaborate computations that make them clinically useless, particularly in critical and emergent situations. Estimation of the amount of ischemic myocardium is useful in monitoring effects of therapeutic interventions. OBJECTIVE: To compare a simplified formula that sums ST-segment deviations in 12 ECG leads with formulas widely validated in clinical trials: anterior ischemic area = 3[1.5(number of leads ST increases) -0.4]; inferior ischemic area = 3[0.6(sigma ST increases II, III, aVF) +2.0]. METHODS: Data were collected from 46 patients undergoing angioplasty of the left anterior descending branch of the coronary artery or the right coronary artery who had changes in the ST segment denoting ischemia during balloon inflation. Absolute values of ST-segment elevations or depressions in the 12 standard ECG leads with a minimum deviation of 0.5 mm were added to determine the sum of the ST-segment deviations during ischemia of the left anterior descending branch of the coronary artery and ischemia of the right coronary artery. This sum was compared with the anterior and inferior ischemic area scores. The Pearson Product-Moment Correlation Coefficient was used to measure the association between the scores. RESULTS: The sum of ST-segment deviations for the left anterior descending branch correlated with the anterior ischemic area score, and the sum of ST-segment deviations for the right coronary artery correlated with the inferior ischemic area score. CONCLUSIONS: The complex, but validated, formulas for anterior ischemic area and inferior ischemic area correlate well with the simpler sum of ST-segment deviations. Because the simpler sum is more clinically useful, it may provide an alternative for monitoring ischemic burden.

Data Interpretation, Statistical↗