Search PubMed⌕ Search

Biomedical subjects

B J Balcom

Publications and source records attributed to B J Balcom.

14 recordsLinked to original sources

A comparison of three SPRITE techniques for the quantitative 3D imaging of the 23Na spin density on a 4T whole-body machine.

Sodium density maps acquired with three SPRITE-based methods have been compared in terms of the resulting quantitative information as well as image quality and acquisition times. Consideration of factors relevant for the clinical implementation of SPRITE shows that the Conical-SPRITE variant is preferred because of a 20-fold reduction in acquisition time, slightly improved image quality, and no loss of quantitative information. The acquisition of a 3D data set (32x32x16; FOV=256x256x160 mm) for the quantitative determination of sodium density is demonstrated. In vivo Conical-SPRITE 23Na images of the brain of a healthy volunteer were acquired in 30 min with a resolution of 7.5x7.5x7.5 mm and a signal-to-noise ratio of 23 in cerebrospinal fluid and 17 in brain tissue.

Brain↗

Spatially resolved measurement of rock core porosity.

Density weighted, centric scan, Conical SPRITE MRI techniques are applied in the current work for local porosity measurements in fluid saturated porous media. The methodology is tested on a series of sandstone core samples. These samples vary in both porosity and degree of local heterogeneity due to bedding plane structure. The MRI porosity measurement is in good agreement with traditional gravimetric measurements of porosity. Spatially resolved porosity measurements reveal significant porosity variation in some samples. This novel MRI technique should have applications to the characterization of local porosity in a wide variety of porous media.

Journal Article↗

Quantitative density profiling with pure phase encoding and a dedicated 1D gradient.

A new centric scan imaging methodology for density profiling of materials with short transverse relaxation times is presented. This method is shown to be more robust than our previously reported centric scan pure phase encode methodologies. The method is particularly well suited to density imaging of low gyro-magnetic ratio non-proton nuclei through the use of a novel dedicated one-dimensional magnetic field gradient coil. The design and construction of this multi-layer, water cooled, gradient coil is presented. Although of large diameter (7.62 cm) to maximize sample cross section, the gradient coil has an efficiency of several times that offered by conventional designs (6 mT/m/A). The application of these ideas is illustrated with high resolution density-weighted proton (1H) images of hazelnut oil penetration into chocolate, and lithium ion (7Li) penetration into cement paste. The methods described in this paper provide a straightforward and reliable means for imaging a class of samples that, until now, have been very difficult to image.

Cacao↗

A novel high temperature 1H NMR imaging probe for combustion studies: the behaviour of both a lit and unlit methane gas jet.

The design of a NMR probe suitable for very high temperature samples is described. The loop gap resonator is water cooled and tuned to 100 MHz for use in a 2.4 T horizontal bore magnet. The probe has been specifically designed for imaging of the combustion process. An experiment is described in this paper which shows the behaviour of a methane gas jet when both lit and unlit. The jet of gas may be observed in its unlit state flowing at up to 2 ms(-1) from a 1 mm diameter orifice using a Single Point Imaging technique. Images of the lit gas show loss of nuclear polarisation within 3 mm of the orifice. A residual amount of un-decomposed gas is visible in the first few millimetres of the flame neck. A computational fluid dynamics model is used to verify the distribution of molecular methane, as well as the temperature of the flame.

Journal Article↗

Centric scan SPRITE magnetic resonance imaging: optimization of SNR, resolution, and relaxation time mapping.

Two strategies for the optimization of centric scan SPRITE (single point ramped imaging with T1 enhancement) magnetic resonance imaging techniques are presented. Point spread functions (PSF) for the centric scan SPRITE methodologies are numerically simulated, and the blurring manifested in a centric scan SPRITE image through PSF convolution is characterized. Optimal choices of imaging parameters and k-space sampling scheme are predicted to obtain maximum signal-to-noise ratio (SNR) while maintaining acceptable image resolution. The point spread function simulation predictions are verified experimentally. The acquisition of multiple FID points following each RF excitation is described and the use of the Chirp z-Transform algorithm for the scaling of field of view (FOV) of the reconstructed images is illustrated. Effective recombination of the rescaled images for SNR improvement and T*2 mapping is demonstrated.

Algorithms↗

Water content profiles with a 1D centric SPRITE acquisition.

The purpose of this work is to develop a rapid MRI method amenable to profiling with minimal or no T(1) relaxation weighting. The behavior of a signal during a centric SPRITE acquisition is analyzed. It is shown that the technique can be made immune to a broad range of T(1) changes. In a properly executed measurement, only T(2)* and proton density parameters define the image intensity. A T(2)* mapping technique can be easily applied, separating T(2)* and proton density contributions to the image. A drying soil sample with low initial water content is experimentally studied as a demonstration of the technique. A characteristic baseline artifact is easily removed from the profiles by a simple operation.

Linear Models↗

Imaging of heterogeneous materials with a turbo spin echo single-point imaging technique.

A magnetic resonance imaging method is presented for imaging of heterogeneous broad linewidth materials. This method allows for distortionless relaxation weighted imaging by obtaining multiple phase encoded k-space data points with each RF excitation pulse train. The use of this method, turbo spin echo single-point imaging-(turboSPI), leads to decreased imaging times compared to traditional constant-time imaging techniques, as well as the ability to introduce spin-spin relaxation contrast through the use of longer effective echo times. Imaging times in turboSPI are further decreased through the use of low flip angle steady-state excitation. Two-dimensional images of paramagnetic doped agarose phantoms were obtained, demonstrating the contrast and resolution characteristics of the sequence, and a method for both amplitude and phase deconvolution was demonstrated for use in high-resolution turboSPI imaging. Three-dimensional images of a partially water-saturated porous volcanic aggregate (T(2L) approximately 200 ms, Deltanu(1/2) approximately 2500 Hz) contained in a hardened white Portland cement matrix (T(2L) approximately 0.5 ms, Deltanu(1/2) approximately 2500 Hz) and a water-saturated quartz sand (T(2) approximately 300 ms, T(2)(*) approximately 800 microseconds) are shown.

Copper Sulfate↗

Single-point magnetic resonance imaging study of water adsorption in pellets of zeolite 4A.

The water uptake process in commercial type particles of zeolite 4A has been studied using a single-point MRI method. True proton density, T1, T2, and T*2 relaxation times were obtained with submillimetric resolution, overcoming the restrictions of short T*2 signals. The molecular mobility in nonequilibrium conditions has been characterized by relaxation time mapping. A clear reduction of the water sorption rate was observed by comparing MRI profiles of a loosely packed bed and gravimetric measurements of spread particles from the same sieved zeolite batch.

Adsorption↗

Relaxation time mapping of short T*2 nuclei with single-point imaging (SPI) methods.

New techniques for quantitative mapping of T1, T2, and T*2 are proposed, based on the single-point imaging (SPI) method, for materials with short nuclear magnetic resonance relaxation times which cannot be imaged with traditional methods. Relaxation times extracted from two-dimensional images of uniform doped agarose phantoms (T*2 approximately 60-210 microseconds) as well as hardened mortar (T*2 approximately 220 microseconds) and polymers (T*2 approximately 20-100 microseconds), using these techniques, agreed with bulk measurements. The method was then applied to a partially dried cylindrical concrete sample (T*2 approximately 115 microseconds).

Image Enhancement↗

The influence of shrinkage-cracking on the drying behaviour of White Portland cement using Single-Point Imaging (SPI).

The removal of water from pores in hardened cement paste smaller than 50 nm results in cracking of the cement matrix due to the tensile stresses induced by drying shrinkage. Cracks in the matrix fundamentally alter the permeability of the material, and therefore directly affect the drying behaviour. Using Single-Point Imaging (SPI), we obtain one-dimensional moisture profiles of hydrated White Portland cement cylinders as a function of drying time. The drying behaviour of White Portland cement, is distinctly different from the drying behaviour of related concrete materials containing aggregates.

Construction Materials↗

Concrete thawing studied by single-point ramped imaging.

A series of two-dimensional images of proton distribution in a hardened concrete sample has been obtained during the thawing process (from -50 degrees C up to 11 degrees C). The SPRITE sequence is optimal for this study given the characteristic short relaxation times of water in this porous media (T2* < 200 micros and T1 < 3.6 ms). The relaxation parameters of the sample were determined in order to optimize the time efficiency of the sequence, permitting a 4-scan 64 x 64 acquisition in under 3 min. The image acquisition is fast on the time scale of the temperature evolution of the specimen. The frozen water distribution is quantified through a position based study of the image contrast. A multiple point acquisition method is presented and the signal sensitivity improvement is discussed.

Image Processing, Computer-Assisted↗

Diffusion in Fe(II/III) radiation dosimetry gels measured by magnetic resonance imaging.

We analyse the diffusion problem in the traditional Fe(II/III) agarose gel system employed in MRI studies of radiation dosimetry. The diffusion coefficient is measured using an inversion recovery null-point imaging method in a model gel/water phantom. The diffusion coefficient of Fe(III) in 1% agarose gel at pH 1.1 is D = 2.7 +/- 0.3 x 10(-6) cm2 s-1. The diffusion coefficient of Fe(II) is D = 3.3 +/- 0.5 x 10(-6) cm2 s-1. Measurement of the diffusion coefficients permits simulation of the MRI signal intensity from phantoms with model radiation dose distributions. We allow for diffusion of both Fe(II) and Fe(III) in our simulations as well as the effect of both relaxation agents on the local spin-lattice relaxation time T1. We also analyse the effects of the physical penumbra on the diffusion problem.

Gels↗

Lateral diffusion in model membranes is independent of the size of the hydrophobic region of molecules.

We have systematically investigated the probe size and shape dependence of lateral diffusion in model dimyristoyl phosphatidylcholine membranes. Linear hydrophobic polymers, which differ in length by an order of magnitude, were used to explore the effect on the lateral diffusion coefficient of hydrodynamic restrictions in the bilayer interior. The polymers employed are isoprenoid alcohols--citronellol, solanesol, and dolichol. Tracer lateral diffusion coefficients were measured by fluorescence photobleaching recovery. Despite the large difference in lengths, the nitrobenzoxadiazole labelled alcohols all diffuse at the rate of lipid self-diffusion (5.0 x 10(-12) m2 s-1, 29 degrees C) in the liquid crystal phase. Companion measurements in isotropic polymer solution, in gel phase lipid membranes and with nonpolar fluorescent polyaromatic hydrocarbons, show a marked dependence of the lateral diffusion coefficient on the probe molecule size. Our results in the liquid crystal phase are in accord with free area theory which asserts that lateral diffusion in the membrane is restricted by the surface-free area. Probe molecules which are significantly longer than the host phospholipid, seven times longer in the case of dolichol, are still restricted in their lateral motion by the surface properties of the bilayer in the liquid crystal phase. Fluorescence quenching experiments indicate that the nitrobenzoxadiazole label does not reside at the aqueous interface, although it must reside in close proximity according to the diffusion measurements.

Diffusion↗

Concrete/mortar water phase transition studied by single-point MRI methods.

A series of magnetic resonance imaging (MRI) water density and T2* profiles in hardened concrete and mortar samples has been obtained during freezing conditions (-50 degrees C < T < 11 degrees C). The single-point ramped imaging with T1 enhancement (SPRITE) sequence is optimal for this study given the characteristic short relaxation times of water in this porous media (T2* < 200 microseconds and T1 < 3.6 ms). The frozen and evaporable water distribution was quantified through a position based study of the profile magnitude. Submillimetric resolution of proton-density and T2*-relaxation parameters as a function of temperature has been achieved.

Cementation↗