[Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy].

PURPOSE: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. MATERIAL AND METHODS: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall accessibility as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). RESULTS: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of - 0.05 (95 % confidence interval [- 0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p = 0.001) but fewer crush artifacts (p = 0.022) while the accessibility did not differ significantly between the two needle types (p = 0.064). There was also no significant difference in the calculated areas of the tissue cores (p = 0.236). According to the different calibers of the biopsy needles, the lengths (p = 0.008) and widths (p = 0.000) of the biopsy specimens differed significantly. CONCLUSIONS: The core biopsy specimens obtained with an MR-compatible 16G titanium alloy biopsy needle are of the same histopathologic quality as specimens obtained with a ferromagnetic 18G stainless steel needle.

Aged↗

Uterine artery embolization for symptomatic fibroids: short-term versus mid-term changes in disease-specific symptoms, quality of life and magnetic resonance imaging results.

BACKGROUND: Prospective study to evaluate changes in symptom severity, health-related quality of life (HRQOL) and uterine and leiomyoma volume after uterine artery embolization (UAE). METHODS: Eighty-two women completed a validated uterine fibroid symptom and quality of life (UFS-QOL) questionnaire and underwent magnetic resonance imaging (MRI) before and 3-20 months after UAE. Primary outcome measures were changes in symptom severity and QOL at short-term follow-up [median 5 (range 3-7) months] and mid-term follow-up [median 14 (8-20) months]. Secondary outcome measures included the frequency of additional procedures to control persistent symptoms and changes in dominant fibroid volume (DFV) and uterine volume (UV). RESULTS: Of 82 patients, 71 (86.6%) patients completed follow-up, 7 (8.5%) patients had a second procedure and 4 (4.9%) were lost to follow-up. Symptom severity scores decreased from a median of 43.75 to 21.88 (P < 0.001) in the short-term follow-up group and from a median of 43.75 to 9.38 (P < 0.001) in the mid-term follow-up group. QOL scores increased from a median of 56.90 to 87.93 (P < 0.001) and 66.81 to 96.12 (P < 0.001), respectively. During short-term follow-up, median UV decreased by 27% (95% CI 20.25-33.81, P < 0.001) and median DFV by 62% (95% CI 47.81-71.55, P < 0.001), whereas UV decreased by 36% (95% CI 23.34-55.02, P < 0.001) and DFV by 66% (95% CI 54.28-71.92, P < 0.001) for the mid-term follow-up group. A decrease in UV correlated with change in symptom severity (P < 0.005). CONCLUSIONS: Women report significant improvements in fibroid-specific symptoms and QOL at short- and mid-term follow-ups after UAE.

Adult↗

Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries.

PURPOSE: To investigate the influence of sublingual glycerol trinitrate (1.2 mg, Nitrate [nitroglycerine], Nitrolingual N Spray) on the coronary artery diameter on multislice computed tomography (MSCT) coronary angiography. MATERIALS AND METHODS: Out of our database of patients who underwent MSCT (slice thickness of 0.5 mm, Aquilion, Toshiba) coronary angiography between July 2003 and November 2005 (950 patients) we retrospectively identified patients with follow-up examinations who received Nitrate for one examination while another examination was performed without Nitrate (10 patients). Another 10 patients who underwent two MSCT examinations with sublingual Nitrate administration were randomly selected from this database to serve as control group. For the resulting 40 MSCT examinations, blinded MSCT datasets were prepared, which were randomly evaluated by a reader blinded to the patient information and whether or not Nitrate had been given. The proximal coronary artery diameters were measured for the left main coronary artery (LMA), the left anterior descending coronary artery (LAD), the left circumflex coronary artery (LCX), and the right coronary artery (RCA) in all 40 datasets, resulting in altogether 160 measurements. RESULTS: The proximal diameters of all four coronary arteries were significantly larger on the MSCT coronary angiograms obtained after sublingual administration of Nitrate compared with the examinations in the same 10 patients without Nitrate (p < 0.001). The average diameters without and with Nitrate for the LMA, LAD, LCX, and RCA were 4.3 +/- 1.1 vs. 4.8 +/- 0.9 mm (12 % increase, p < 0.005), 3.0 +/- 0.6 vs. 3.5 +/- 0.5 mm (17 % increase, p < 0.001), 2.7 +/- 0.6 vs. 3.2 +/- 0.7 mm (19 % increase, p < 0.005), and 2.9 +/- 0.9 vs. 3.5 +/- 0.7 mm (21 % increase, p < 0.005), respectively. In the control group of 10 patients who underwent two MSCT coronary angiographies after sublingual Nitrate, no significant difference in the proximal diameter of all four main coronary vessels was observed. CONCLUSION: Sublingual administration of Nitrate results in significantly larger proximal coronary artery diameters on MSCT coronary angiography and might thus be recommended for routine examinations.

Administration, Sublingual↗

[Whole-body MR angiography: comparison of two protocols for contrast media injection].

PURPOSE: To compare two injection strategies for contrast media injection in whole-body MR angiography quantitatively and qualitatively with regard to contrast and image quality. MATERIAL AND METHODS: 40 patients were examined at 1.5 Tesla using either a single injection protocol or a double injection protocol with two separate bolus injections. Vessel regions I (supraaortic/thoracic), II (abdominal/pelvic), III (upper legs) and IV (lower legs) were examined in the following order: single injection: I, II, III, IV, double injection: I and IV after the first injection, II and III after the second bolus injection. Quantitative evaluation: SI measurements were carried out in 2 arteries per region. Contrast values were calculated. Qualitative evaluation: Evaluation of regions I-IV regarding vessel contrast, venous overlay and image quality on a five-point scale by two reviewers in consensus. The Mann-Whitney-U test was used to test the differences for significance. RESULTS: Quantitative evaluation: Using the double injection protocol, significantly higher contrast values in regions I and II and significantly lower contrast values in the subregions IIIa (upper part of III) and IVb (lower part of IV) were obtained (p < 0.05). The mean contrast values in subregions IIIb (lower part of III) and IVa (upper part of IV) were lower using the double injection protocol, but not significantly. Qualitative evaluation: Using the double injection protocol, region II was rated significantly higher (mean ratings: 3.55, 3.45 and 3.5 versus 2.7, 2.5 and 2.55; p < 0.05) and region III significantly lower (mean ratings: 3.1, 2, 2.5 versus 3.9, 3.1 and 3.55; p < 0.05) for all three examined criteria. When using the double injection protocol, ratings were significantly lower in region IV regarding vessel contrast and image quality (mean ratings: 2.4 and 2.15 versus 3.45 and 3.15; p < 0.05). The ratings regarding venous overlay in region IV showed no significant differences (mean ratings: 2.15 versus 2.75; p > 0.05). CONCLUSION: Due to the better results in the supraaortic/thoracic and abdominal/pelvic regions, the double injection protocol is preferred. However, both protocols require further improvement.

Adult↗

[A new method for standardized diagnosis following renal transplantation. Ultrasound with contrast enhancement].

Ultrasound (US) imaging is an important diagnostic tool following renal transplantation. Unfortunately, due to the heterogeneity of the recipients and their multimorbidity, imaging procedures in the early phase after kidney transplantation are difficult and of limited use. We performed a study to evaluate the use of a contrast enhancer for US examination as a standardized method in the follow-up of kidney transplant recipients.The study included 40 recipients: 32 were examined on the 5th to 7th day following transplantation and 8 patients at the time when clinically suspicious findings occurred (acute rejection, tumor, acute tubular necrosis). Following the intravenous application of the contrast medium, pictures were taken during the arterial and parenchymatous phase and compared with conventional B-mode and power Doppler pictures of the same visual plane. Three examiners assessed different parameters of the transplant organ (max. vascularized area, suspected hematomas, tumors, rejection, acute tubular necrosis). Findings were confirmed by histological results of a biopsy if rejection, tumor, or acute tubular necrosis were suspected. Application of ultrasound contrast medium significantly increased visualization of the vascularized kidney area. Also, US findings in the follow-up after acute rejection therapy corresponded with the clinical course; 19 hematomas could be detected with contrast medium compared to only 9 without. With contrast medium a perfusion deficit was detectable in three patients compared to one patient with power Doppler US. Also, US contrast medium helped to detect tumor vascularization in two patients in whom conventional sonography suspected no abnormality. Ultrasound contrast medium enhancement is a reproducible, reliable, and easy to apply method which is superior to conventional sonography in the follow-up after kidney transplantation. This method is also helpful to detect and control acute rejections and to better visualize hematomas, deficits of perfusion, and tumors.

Adolescent↗

[Characterization of sonographically detected breast lesions using three-dimensional data sets].

PURPOSE: The diagnostic value of 3D ultrasound (US) was evaluated in comparison to 2D US on the basis of a set of pre-defined criteria for breast lesions. The individual criteria were correlated with the histological findings and they were ranked according to their significance for lesion characterization in both 3D US and 2D US. MATERIALS AND METHODS: A total of 92 breast lesions were examined of which 61 were malignant and 31 were benign, as confirmed by histology of core biopsy specimens (Aplio 80, Toshiba, Otawara, Japan). The 2D and 3D data sets were stored digitally. The vascular tree was stored separately using 3D fusion. In addition, a power Doppler (PD) examination was performed. A total of 644 individual images were evaluated by two independent readers. The lesions were evaluated using established criteria (BI-RADS classification). For statistical evaluation, the individual US measurements were classified according to the following two groups: those suggesting malignant lesions and those suggestive of benign lesions. Pearsons's chi-square test was performed for both groups. The 2D and 3D techniques were compared directly using kappa (kappa) statistics. Odds ratios (OR) were determined for the purpose of weighting the individual criteria. The sensitivities and specificities of 2D and 3D US were calculated. RESULTS: The diagnostic value of 3D US was comparable to that of 2D US, with only slight differences observed for specific measurements. Analysis of 2D US data indicated that there was a strong correlation between malignant tumor growth and two specific 2D criteria: lesion margin and effect of the lesion on adjacent breast tissue (r (2) = 0.632, p < 0.001). Analysis of 3D images indicated that the significant measurements for tumor malignancy were shape and lesion margin in sagittal, transverse (r (2) = 0741, p < 0.001), and frontal views (r (2) = 0.592, p < 0.001) as well as retraction and lesion demarcation in the frontal views (r (2) = 0.649, p < 0.001). The comparison of 2D and 3D yielded primarily moderate (kappa = 0.412) to good (kappa = 0.789) agreement between the individual criteria. Crucial criteria for lesion characterization were the effect of the lesion on adjacent breast tissue (OR 47.8 [16.0-143.3]) in 2D US and the lesion margin (OR 36.4 [15.3-86.6]) and the 3 additional criteria of the frontal plane (OR 21.9-32.9) in 3D US. The two US techniques had comparable sensitivities (2D/3D 95-97 %/92-95 %) and specificities (2D/3D 54-58 %/61-67 %). The reconstructed 3D view of the vascular tree was subjectively considered to be helpful by both readers. A higher degree of vascularization was observed with 3D US. CONCLUSIONS: The diagnostic role of 3D ultrasound in the diagnostic evaluation of breast cancer is comparable to that of 2D US. Our findings illustrate the significance of the evaluation of frontal views in lesion characterization.

Adult↗

Cine magnetic resonance imaging of the small bowel: comparison of different oral contrast media.

PURPOSE: To evaluate several substances regarding small bowel distension and contrast on balanced steady-state free precession (bSSFP) cine magnetic resonance (MR) images. MATERIAL AND METHODS: Luminal contrast was evaluated in 24 volunteers after oral application of two different contrast agent groups leading to either bright lumen (pineapple, blueberry juice) or dark lumen (tap water, orange juice) on T1-weighted images. Bowel distension was evaluated in 30 patients ingesting either methylcellulose or mannitol solution for limiting intestinal absorption. Fifteen patients with duodeno-jejunal intubation served as the control. Quantitative evaluation included measurement of luminal signal intensities and diameters of four bowel segments, qualitative evaluation assessed luminal contrast and distension on a five-point scale. RESULTS: Quantitative and qualitative evaluation of the four contrast agents revealed no significant differences regarding luminal contrast on bSSFP images. Quantitative evaluation revealed significantly lower (P<0.05) small bowel distension for three out of four segments (qualitative evaluation: two out of four segments) for methylcellulose in comparison to the control. Mannitol was found to be equal to the control. CONCLUSION: Oral ingestion of tap water or orange juice in combination with mannitol is recommended for cine MR imaging of the small bowel regarding luminal contrast and small bowel distension on bSSFP sequences.

Administration, Oral↗

Prospective 7 year follow up imaging study comparing radiography, ultrasonography, and magnetic resonance imaging in rheumatoid arthritis finger joints.

OBJECTIVE: To perform a prospective long term follow up study comparing conventional radiography (CR), ultrasonography (US), and magnetic resonance imaging (MRI) in the detection of bone erosions and synovitis in rheumatoid arthritis (RA) finger joints. METHODS: The metacarpophalangeal and proximal interphalangeal joints II-V (128 joints) of the clinically dominant hand of 16 patients with RA were included. Follow up joint by joint comparisons for erosions and synovitis were made. RESULTS: At baseline, CR detected erosions in 5/128 (4%) of all joints, US in 12/128 (9%), and MRI in 34/128 (27%). Seven years later, an increase of joints with erosions was found with CR (26%), US (49%) (p<0.001 each), and MRI (32%, NS). In contrast, joint swelling and tenderness assessed by clinical examination were decreased at follow up (p = 0.2, p<0.001). A significant reduction in synovitis with US and MRI (p<0.001 each) was seen. In CR, 12 patients did not have any erosions at baseline, while in 10/12 patients erosions were detected in 25/96 (26%) joints after 7 years. US initially detected erosions in 9 joints, of which two of these joints with erosions were seen by CR at follow up. MRI initially found 34 erosions, of which 14 (41%) were then detected by CR. CONCLUSION: After 7 years, an increase of bone erosions was detected by all imaging modalities. In contrast, clinical improvement and regression of synovitis were seen only with US and MRI. More than one third of erosions previously detected by MRI were seen by CR 7 years later.

Adult↗

[Transarterial embolization for uterine fibroids: clinical success rate and results of magnetic resonance imaging].

PURPOSE: To analyze the clinical success rate and the findings of magnetic resonance imaging (MRI) after uterine artery embolization of symptomatic leiomyomas (fibroids) of the uterus. MATERIALS AND METHODS: This is a prospective single-center case study of 80 consecutively treated patients, followed for 3 - 6 months (group I), 7 - 12 months, (group II), and 13 - 25 months (group III). MRI was used to determine the uterine volume and size of the dominant leiomyoma. Symptoms and causes requiring repeat interventions were analyzed. RESULTS: Significant (p < 0.01) volume reduction of the uterus (median: 34.95 % confidence interval [CI]: 30.41 - 41.76 %) and dominant leiomyoma (median: 52.07 %, CI: 47.71 - 61.57 %) was found. The decrease in uterine volume (I-III: 22.68 %, 33.56 %, 47.93 %) and dominant leiomyoma volume (I-III: 41.86 %, 62.16 %, 73.96 %) progressed with the follow-up time. Bleeding resolved significantly (p < 0.0001) in all three follow-up groups (groups I-III: 92.86 %, 95.23 %, 96.67 %). Furthermore, urinary frequency (groups I-III: 70 %, 75 %, 82.35 %) and sensation of pelvic pressure (groups I-III: 42.86 %, 60 %, 93.75 %) improved, which was statistically significant in group III (p < 0.01). The number of leiomyomas correlated (p < 0.05) with improvement of the bleeding and the pelvic pressure. Repeat therapy was necessary for complications in four patients (5 %) and for therapeutic failure in three patients (3.8 %). Permanent amenorrhea was observed in four patients (5 %) of age 45 years or older. CONCLUSION: Uterine artery embolization of uterine leiomyomas has a high clinical success rate with an acceptable incidence of complications and repeat interventions.

Adult↗

[Endovenous treatment of primary varicose veins: an effective and safe therapeutic alternative to stripping?].

Endovenous laser therapy (EVLT) is a new, minimally invasive therapeutic option for treating primary varicose veins and provides an effective and safe alternative to conventional surgical management (stripping). Short-term and intermediate-term outcome is comparable to surgical stripping in terms of elimination of venous reflux (90 % - 98 %), resolution of visible varices (85 %), and improvement of subjective complaints such as sensations of heaviness and tension (96 %). Complications occur in 1 % - 3 % of cases, which is markedly below the rate of conventional surgical management (up to 30 %). The intermediate-term incidence of recurrent varicosis in a vein treated by EVLT depends on the laser fluence applied and is reported to range from 7 % - 9 % compared to 10 % - 20 % after surgical intervention. Based on a review of the current literature and our own experience, this survey article presents an overview of the indications and contraindications, the technique and pathophysiology of laser-induced venous occlusion, and the results and possible complications of EVLT.

Anesthesia↗

[Surgery for congestive heart failure--the role of computed tomography in the pre- and postoperative diagnostic evaluation].

The treatment of advanced, drug resistant congestive heart failure gains in importance in the field of cardiac surgery. Cardiac imaging for preoperative assessment and follow-up focuses on the determination of ventricular volumes and function as well as on the detection of postoperative complications. Computed tomography (CT) is highly accurate irrespective of the individual patient's anatomic situation, has a low examiner dependence and short examination time, does not require an arterial vascular access and can be performed in patients with metal implants. CT is the modality of choice in the follow-up of heart transplants to detect extracardiac and cardiac complications including coronary calcifications as an early sign of transplant vasculopathy. In addition, CT visualizes the elements of mechanical assist devices and can identify their possible local cardiac and mediastinal complications. CT can detect fibrolipomatous involution of the mobilized muscle flap in dynamic cardiomyoplasty and can depict fibrous reactions along the epicardial mesh implant in passive cardiac containment. Further indications include assessment of typical local postoperative complications, such as intrathoracic infection and mediastinal bleeding, intracardiac thrombus formation or pericardial effusion. CT is routinely used for evaluating bypass patency but is limited in assessing associated valve defects since it does not visualize flow.

Cardiovascular Surgical Procedures↗

[MRI for troubleshooting detection of prostate cancer].

Prostate cancer is the most common malignancy in males. Men aged 50 and older are recommended to undergo an annual digital rectal examination (DRE) and determination of prostate-specific antigen (PSA) in serum for early detection. However, prostate biopsies guided by transrectal ultrasound (TRUS) come up negative for cancer in many patients despite having PSA levels above 4 ng/ml. T2-weighted Magnetic Resonance Imaging (MRI) is able to represent the prostate including the surrounding anatomy and depict suspicious areas of low intensity within a high-intensity peripheral zone. MRI has a higher sensitivity for detecting prostate carcinomas than DRE and TRUS in patients having an elevated PSA value and a negative core biopsy. However, its specificity is poor since other abnormalities such as prostatic intraepithelial neoplasia (PIN), prostatitis, scars, or haemorrhage have a similar MRI appearance. The use of additional techniques such as MR spectroscopy and contrast-enhanced dynamic MRI improves sensitivity, but in particular it improves the specificity of tumor detection. Newly developed biopsy devices enable the performance of targeted biopsies in areas that appear suspicious in the MRI.

Biopsy↗

Differentiation of prostate cancer from normal prostate tissue in an animal model: conventional MRI and dynamic contrast-enhanced MRI.

PURPOSE: To differentiate orthotopically implanted prostate cancer from normal prostate tissue using magnetic resonance imaging (MRI) and Gd-DTPA-BMA-enhanced dynamic MRI in the rat model. MATERIAL AND METHODS: Tumors were induced in 15 rats by orthotopic implantation of G subline Dunning rat prostatic tumor cells. MRI was performed 56 to 60 days after tumor cell implantation using T1-weighted spin-echo, T2-weighted turbo SE sequences, and a 2D FLASH sequence for the contrast medium based dynamic study. The interstitial leakage volume, normalized permeability and the permeability surface area product of tumor and healthy prostate were determined quantitatively using a pharmacokinetic model. The results were confirmed by histologic examination. RESULTS: Axial T2-weighted TSE images depicted low-intensity areas suspicious for tumor in all 15 animals. The mean tumor volume was 46.5 mm(3). In the dynamic study, the suspicious areas in all animals displayed faster and more pronounced signal enhancement than surrounding prostate tissue. The interstitial volume and the permeability surface area product of the tumors increased significantly by 420 % (p < 0.001) and 424 % (p < 0.001), respectively, compared to normal prostate tissue, while no significant difference was seen for normalized permeability alone. CONCLUSION: The results of the present study demonstrate that quantitative analysis of contrast-enhanced dynamic MRI data enables differentiation of small, slowly growing orthotopic prostate cancer from normal prostate tissue in the rat model.

Animals↗

Complex genital malformation in a female with congenital adrenal hyperplasia: evaluation with magnetic resonance imaging.

This is a case of complex genital malformation in a young patient with congenital adrenal hyperplasia. The magnetic resonance imaging (MRI) findings included ostium of the vagina into the urethra (common urogenital opening), prostate-like tissue surrounding the urethra, and hyperplasia of the left adrenal gland. The report provides information on the clinical findings, the MRI examination, including the applied sequences and the MR findings, and gives an overview of the disease pattern and its frequency of occurrence.

Adrenal Hyperplasia, Congenital↗

Near monochromatic X-rays for digital slot-scan mammography: initial findings.

X-ray spectra are composed of a broad bremsspectrum and anode-characteristic emission lines. In mammography typically molybdenum (Mo), rhodium (Rh) or tungsten (W) anodes are used in combination with Mo, Rh or aluminium filters. Only the photons with energies between 17 and 22 keV of the resulting spectrum are suitable for the soft tissue imaging needed for mammography. The aim of this article is to present first results obtained with a monochromator module mounted at the exit of the X-ray tube of a conventional clinical mammography unit. The experimental setup consists of a Siemens Mammomat 300, an X-ray monochromator module and a linear array detector for image acquisition. The technique is similar to the slot-scan technique known from digital mammography. The experimental machine allows to obtain images both with polychromatic and monochromatic X-rays. Initial evaluation of the system was performed by examination of a contrast-detail phantom (CD-MAM-phantom, Nijmegen, The Netherlands). Images done with the new monochromatic technique were compared to images of the phantom done with polychromatic spectra, with film-screen mammography as well as with digital mammography. The new technique with monochromatic slot-scan mammography resulted in correct identification of 93% of the phantom. Digital slot-scan mammography with polychromatic beam resulted in correct identification of 87%, digital full-field mammography in 83% and conventional film-screen mammography in 70% of the phantom. The results suggest that monochromatization has a potential for improving image quality or decreasing dose in X-ray mammography.

Equipment Design↗