Bioelectrical impedance for monitoring the efficacy of lymphoedema treatment programmes.

The treatment of lymphoedema includes a combination of massage, compression bandaging, and exercise. To date the most common technique of assessing the efficacy of treatment has involved estimating the total limb volume from circumferential measurements at fixed intervals along the limb. This study investigated the application of multiple frequency bioelectrical impedance analysis, MFBIA, to monitor the volume of lymphoedema in the upper limb of patients who developed this disorder following surgery for cancer of the breast. Daily measurements of both circumference and impedance of both the affected and unaffected limbs were recorded for 20 patients throughout their 4 week treatment programmes. Twenty control subjects were also monitored daily over a similar 4 week period. Prior to the commencement of treatment the bioimpedance technique detected a significant (P < 0.01) asymmetry between the two limbs of the control subjects, associated with handedness (P < 0.001). Circumferential estimates of limb volumes in the control group detected no asymmetry. Impedance measures of extracellular fluid showed all of the patients to lie outside the 95% confidence interval determined from the data of the control group. The trends of the impedance measures and the circumferential estimates of volume throughout the 4 week program were found to be significantly different (P < 0.05); MFBIA exhibiting a greater sensitivity in the detection of lymphoedema. The results demonstrate that MFBIA is significantly more sensitive than circumferential measurement both in the early diagnosis of lymphoedema and in monitoring change.

Adult↗

Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans.

OBJECTIVE: To assess the application of a Cole-Cole analysis of multiple frequency bioelectrical impedance analysis (MFBIA) measurements to predict total body water (TBW) and extracellular water (ECW) in humans. This technique has previously been shown to produce accurate and reliable estimates in both normal and abnormal animals. DESIGN: The whole body impedance of 60 healthy humans was measured at 496 frequencies (ranging from 4 kHz to 1 MHz) and the impedance at zero frequency, Ro, and at the characteristic frequency, Zc, were determined from the impedance spectrum, (Cole-Cole plot). TBW and ECW were independently determined using deuterium and bromide tracer dilution techniques. SETTING: At the Dunn Clinical Nutrition Centre and The Department of Biochemistry, University of Queensland. SUBJECTS: 60 healthy adult volunteers (27 men and 33 women, aged 18-45 years). RESULTS: The results presented suggest that the swept frequency bioimpedance technique estimates total body water, (SEE = 5.2%), and extracellular water, (SEE = 10%), only slightly better in normal, healthy subjects than a method based on single frequency bioimpedance or anthropometric estimates based on weight, height and gender. CONCLUSIONS: This study has undertaken the most extensive analysis to date of relationships between TBW (and ECW) and individual impedances obtained at different frequencies ( > 400 frequencies), and has shown marginal advantages of using one frequency over another, even if values predicted from theoretical bioimpedance models are used in the estimations. However in situations where there are disturbances of fluid distribution, values predicted from the Cole-Cole analysis of swept frequency bioimpedance measurements could prove to be more useful.

Adolescent↗

Multiple frequency bioelectrical impedance for the prediction of total body potassium in cystic fibrosis.

The use of multiple frequency bioelectrical impedance analysis (MFBIA) was compared with single frequency bioelectrical impedance analysis (SFBIA) and anthropometry to estimate the size of the body cell mass (BCM) in a paediatric cystic fibrosis population. BCM was independently determined from the accepted gold standard reference of total body potassium (TBK). MFBIA was used to measure the impedance of the body at 248 frequencies from 4 kHz to 1 MHz. Data were analysed using Cole-Cole plots of reactance versus resistance. The limits of agreement procedure was used to determine the reliability and precision of the different techniques to predict values for TBK, in an individual subject. The results indicate that MFBIA with a precision of 12% offers little improvement over single frequency BIA but is better and more accurate than anthropometry for the prediction of TBK in an individual patient.

Journal Article↗

The use of Cole-Cole plots to compare two multifrequency bioimpedance instruments.

Two commercially available multifrequency bioimpedance spectrometers (Xitron 4000B and SEAC SFB3) were compared by performing measurements on a set of electronic circuits and by studying 14 healthy volunteers. Output data were plotted as reactance versus resistance and fitted with a semi-circle using a least squares fitting program. In tests with six electronic circuits both instruments produced impedance loci that were well described by semicircular Cole-Cole plots, though there were some minor discrepancies using the Xitron instrument at frequencies above 150 kHz. When tested on the volunteers the SEAC instrument gave very good fits (RMSE = 1.5 Omega) to a semi-circle from 5-600 kHz on all volunteers. The Xitron instrument gave excellent fits to the semi-circle between 5 and 55 kHz (RMSE = 0.7 Omega) but above 55 kHz the phase measurements stayed constant or even increased, confirming the anomalous behaviour reported by other authors. The conclusions to be drawn are that the semicircular plots predicted by the Cole-Cole theory give a very good description of multifrequency impedance data recorded by the SEAC SFB3 instrument, on human subjects, for frequencies between 5 and 600 kHz. The Xitron 4000B is not able to reproduce the theoretically expected results in humans above 55 kHz.

Journal Article↗

Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis.

Bioelectrical impedance analysis (BIA) using a frequency of 50 kHz is an established method of predicting total body water (TBW). However, very little research has been performed to determine whether 50 kHz is the optimum frequency for the prediction of TBW from impedance measurements. This paper analyses a mathematical expression describing the equivalent electrical circuit for biological tissue, and derives a graphical representation of the resistive and reactive components. The nature of the resulting impedance locus was used in the analysis of measured whole-body impedance of 42 rats over a range of frequencies to determine the impedance at the characteristic frequency, Zc, and also the impedance at zero frequency, R0. The standard error associated with the prediction of TBW (determined by isotope dilution) using Zc was 5.9% compared with a standard error of prediction of 10.1% using the established BIA method at 50 kHz on the same data. Predictions of extracellular water (ECW) using the impedance at zero frequency, R0, yielded a standard error of 3.2% compared with standard errors of 4.8% and 4.2% using single frequency BIA measurements at 5 kHz and 1 kHz, respectively. These results demonstrate a significant (P < 0.01) improvement in the prediction of TBW and ECW using multiple frequency bioelectrical impedance analysis (MFBIA).

Animals↗

Multi-frequency bioelectrical impedance augments the diagnosis and management of lymphoedema in post-mastectomy patients.

The value of multiple frequency bioelectric impedence analysis (MFBIA) in the monitoring and management of post-mastectomy lymphoedema of the arm was evaluated in 15 patients and controls. The technique was found to produce quantitative agreement with a clinical diagnosis of lymphoedema and with the currently-used measure (limb volume calculated from circumferential measurements) of limb size. The significance of this finding lies in MFBIA being diagnostically informative: it indicates when an observed change in limb volume is directly, albeit theoretically, attributable to accumulation of extracellular fluid. MFBIA potentially offers the means for earlier definitive diagnosis and more-accurate monitoring of extracellular fluid changes during and after treatment.

Adult↗

Bioimpedance spectrometry in the determination of body water compartments: accuracy and clinical significance.

Bioelectrical impedance analysis (BIA) offers the potential for a simple, portable and relatively inexpensive technique for the in vivo measurement of total body water (TBW). The potential of BIA as a technique of body composition analysis is even greater when one considers that body water can be used as a surrogate measure of lean body mass. However, BIA has not found universal acceptance even with the introduction of multi-frequency BIA (MFBIA) which, potentially, may improve the predictive accuracy of the measurement. There are a number of reasons for this lack of acceptance, although perhaps the major reason is that no single algorithm has been developed which can be applied to all subject groups. This may be due, in part, to the commonly used wrist-to-ankle protocol which is not indicated by the basic theory of bioimpedance, where the body is considered as five interconnecting cylinders. Several workers have suggested the use of segmental BIA measurements to provide a protocol more in keeping with basic theory. However, there are other difficulties associated with the application of BIA, such as effects of hydration and ion status, posture and fluid distribution. A further putative advantage of MFBIA is the independent assessment not only of TBW but also of the extracellular fluid volume (ECW), hence heralding the possibility of being able to assess the fluid distribution between these compartments. Results of studies in this area have been, to date, mixed. Whereas strong relationships of impedance values at low frequencies with ECW, and at high frequencies with TBW, have been reported, changes in impedance are not always well correlated with changes in the size of the fluid compartments (assessed by alternative and more direct means) in pathological conditions. Furthermore, the theoretical advantages of Cole-Cole modelling over selected frequency prediction have not always been apparent. This review will consider the principles, methodology and applications of BIA. The principles and methodology will be considered in relation to the basic theory of BIA and difficulties experienced in its application. The relative merits of single and multiple frequency BIA will be addressed, with particular attention to the latter's role in the assessment of compartmental fluid volumes.

Body Composition↗

Effect of temperature and sweating on bioimpedance measurements.

The effect of skin temperature and hydration status has been suggested by some researchers as a common cause of variation in bioimpedance measurements of the body. This paper details a simple method of measuring the transverse impedance of the skin. The measured resistance and reactance was found to decrease by 35% and 18% for an increase of 20 degrees C. Similarly a decrease in resistance and reactance of 20% and 25% respectively was detected after hydration of the skin. However, the changes in skin temperature and hydration were found to have no significant effect on the whole body bioimpedance measurements using the standard tetra-polar electrode technique.

Body Composition↗

A comparison of segmental and wrist-to-ankle methodologies of bioimpedance analysis.

The common approach of bioelectrical impedance analysis to estimate body water uses a wrist-to-ankle methodology which, although not indicated by theory, has the advantage of ease of application particularly for clinical studies involving patients with debilitating diseases. A number of authors have suggested the use of a segmental protocol in which the impedances of the trunk and limbs are measured separately to provide a methodology more in keeping with basic theory. The segmental protocol has not, however, been generally adopted, partly because of the increased complexity involved in its application, and partly because studies comparing the two methodologies have not clearly demonstrated a significant improvement from the segmental methodology. We have conducted a small pilot study involving ten subjects to investigate the efficacy of the two methodologies in a group of normal subjects. The study did not require the independent measure of body water, by for example isotope dilution, as the subjects were maintained in a state of constant hydration with only the distribution between limbs and trunk changing as a result of change in posture. The results demonstrate a significant difference between the two methodologies in predicting the expected constancy of body water in this study, with the segmental methodology indicating a mean percentage change in extracellular water of -2.2%, which was not significantly different from the expected null result, whereas the wrist-to-ankle methodology indicated a mean percentage change in extracellular water of -6.6%. This is significantly different from the null result, and from the value obtained from the segmental methodology (p = 0.006). Similar results were obtained using estimates of total body water from the two methodologies.

Ankle↗

Bioelectrical impedance analysis for measurement of body fluid volumes: a review.

The need for a portable, inexpensive, accurate and safe method for measuring body composition is well established. Bioelectrical impedance analysis (BIA) has the potential to partially meet this need by estimating the water component of body composition. There are still a number of unresolved questions and limitations to the applications of BIA, however. This paper briefly reviews the theory of BIA, its application and its limitations. Recent progress in the development and validation of swept or multiple frequency BIA used to determine both extracellular water and total body water is discussed in detail.

Adipose Tissue↗