Search PubMed⌕ Search

Biomedical subjects

B H Brown

Publications and source records attributed to B H Brown.

At least 55 records · Page 3Linked to original sources

Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. In addition there arises an increase in p' in early systole towards the periphery of the lung. Frequency behaviour of p' changes with location. At all times after the R-wave, in the centre of the lung p' is higher at higher frequency f whereas in the periphery it is lower at higher f. The principal decrease in p' can be explained by increasing pulmonary blood volume due to cardiac contraction. The early systolic increase is presumably due to venous return to the left atrium locally leading blood output from the right ventricle which is delayed by the windkessel effect. Based on a model taking extracapillary and capillary blood volume increase into account, the change in frequency behaviour of p' is explained by regional variations in extracapillary blood vessel size determining the relative contributions of extracapillary blood volume and capillary blood volume change to p' at a certain frequency.

Adult↗

Modelling of cardiac-related changes in lung resistivity measured with EITS.

Resistivity data from 9.6 kHZ to 1.2 MHz were recorded from eight normal subjects using an electrical impedance tomographic spectroscopy (EITS) system and then averaged to a mean cardiac cycle using the ECG gating technique. The Cole-Cole model, that is, extracellular resistance R connected in parallel with intracellular resistance S and membrane capacitance C in series, with a distribution parameter a, was applied to model the frequency characteristics and to produce parametric images. During systole, SC and RC were found to decrease and FR increase. The changes in R/S were not consistent among the subjects. We estimated the peak changes in R, S and C to be -2.5%, -3.3% and -7.6% respectively. The results can be explained by considering the blood vessels as spheres of different sizes with blood inside them. The decrease in R during systole might be caused by the increased blood content in relatively large vessels, whereas that in S by the increased blood volume in relatively small vessels. The capacitance of blood is normally smaller than that of lung tissue, whereas FR blood is higher than that of lung tissue. Hence, as blood content increases, C should decrease and FR increase.

Blood Volume↗

A fast parametric modelling algorithm with the Powell method.

This paper presents a model that comprises only two parameters (R/S, fr) and the application of three function minimization algorithms (simplex, Powell and modified Powell) to this model to obtain parametric images. Comparisons among the three algorithms in terms of efficiency and reliability were carried out. It was found that, with proper initialization by taking the shape of the modelled data into consideration, the minimization function can be approximated by a quadratic function near the minimum point, therefore the iteration times can be minimized in the modified Powell method. The results show that with the modified Powell method a substantial reduction of computation time can be achieved in the parametric imaging. This makes it possible to obtain a 16 x 16 parametric image in 1 s.

Algorithms↗

Measured and expected Cole parameters from electrical impedance tomographic spectroscopy images of the human thorax.

Electrical impedance tomographic spectroscopy (EITS) images have been recorded from a group of 12 normal subjects using frequencies from 9.6 kHz to 1.2 MHz. The impedance changes with frequency have been modelled on a pixel by pixel basis to produce parametric images as a means of characterizing tissue. The modelling was based on the Cole equation. The lungs are seen as areas of high characteristic frequency and low time constants SC and RS. The R/S images are much less uniform over the region of the lungs. Values characterizing the lung and cardiac regions are given. The results appear to be consistent with a model for the lungs whereby the model parameters can be related to alveolar structure and composition.

Adult↗

Detecting oesophageal-related changes using electrical impedance tomography.

Preliminary work has been carried out using the Sheffield mark II real time EIT system, looking for changes in conductivity which occur in the stomach and oesophagus following a swallow of a small volume of either a conducting or a non-conducting liquid. This has been done using three different configurations: a conventional transverse array placed around the thorax, a rosette array on the abdomen, and a rosette array placed on the back. Results show a significant difference between the two liquids, which can be detected equally well by the three electrode configurations.

Adult↗

Multifrequency and parametric EIT images of neonatal lungs.

The aims of the study were to investigate the problems involved in making multifrequency EIT measurements on neonates and to compare the images obtained with the results from a group of normal adults. The Sheffield electrical impedance tomographic spectroscopy (EITS) system acquires multifrequency data using a set of eight drive and eight receive electrodes. EITS measurements were made on an inhomogeneous group of 10 neonates admitted to the special care baby unit for observation and feeding. R/S, characteristic frequency, RC and SC parameters were generated using the Cole equation. Comparisons of the parameters were made with data collected from normal adults in another study. We have shown that it is possible to obtain EITS parametric images of neonatal lungs and that there are some differences in Cole parameters between the adult and neonatal groups.

Adult↗

Identifying oesophageal contents using electrical impedance tomography.

Investigations have been carried out using the Sheffield mark II real-time EIT system, to look at changes in conductivity associated with swallowing. A ring of 16 electrodes was placed around the neck of 10 subjects, who then performed swallows with four liquids of different conductivities, ranging from water (sigma = 0.03 mS cm-1) to salty soup (sigma = 35.8 mS cm-1). Results showed that the conductive and non-conductive liquids could be distinguished. Bolus transit times were calculated from region of interest curves, and the average transit time for the 10 subjects was found to be 320 +/- 100 ms.

Deglutition↗

A real-time electrical impedance tomography system for clinical use--design and preliminary results.

An instrument is described which produces images of the electrical impedance distribution within the body at a rate of 25 frames per second, allowing lung ventilation and lung perfusion to be observed in real time. The instrument makes impedance measurements using an array of 16 electrodes on the surface of the body, and reconstructs the images using a weighted backprojection technique. The design of the data acquisition electronics and the reconstruction and display processor are described. Some preliminary in vitro and in vivo results from the system are presented.

Algorithms↗

Detection of changes in intrathoracic fluid in man using electrical impedance tomography.

1. The Sheffield electrical impedance tomography system produces information on changes in the distribution of resistivity within tissue. We report on the assessment of electrical impedance tomography in monitoring changes in lung resistivity during a fluid challenge in normal man. 2. Eight normal subjects were studied. Electrical impedance tomography recordings were made at three different lung volumes before, during and after the intravenous infusion of 1 litre of 0.9% NaCl (saline). 3. The mean fall in lung resistivity during the infusion was -22% at total lung capacity (range -10% to -28%), -24% at tidal breathing (-15% to -37%) and -11% at residual volume (-5% to -19%) (P < 0.05 mean pre-infusion resistivity compared with the nadir value after infusion, Wilcoxon). 4. These changes in lung resistivity were probably due to a combination of a fall in haematocrit and an expansion of pulmonary blood volume.

Adult↗

Multi-frequency imaging and modelling of respiratory related electrical impedance changes.

Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are investigated using Cole-Cole modelling and also a physiological model of lung tissue. There is an excellent fit to the Cole-Cole model, and the results show that it should be possible to identify tissue on the basis of the impedance spectrum and the spectrum of the changes in impedance during breathing.

Cardiography, Impedance↗

A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli.

EIT images have been recorded from the upper thorax of 10 normal subjects and from two patients with pulmonary emboli. The Sheffield Mk2 system was used to obtain the EIT images during quiet tidal breathing and the images were then analysed to extract the cardiac and respiratory related components. In the 10 normal subjects the mean measured change in resistivity during tidal breathing was 9% (SD 3%) with no significant difference in four lung regions. The mean changes during the cardiac cycle were different in the four regions, ranging from -0.9% to -2.6%. The two patients showed very different cardiac related changes from those found in the normals in the posterior lung regions. The sign of the changes was positive, whereas it was negative in the normals. The changes in the anterior lung regions were within the range found in our normal group.

Adult↗

Noise equalization within EIT images.

We first describe experiments designed to measure the spatial distribution of noise within an electrical impedance tomographic image of a saline-filled tank. These experiments show that the noise increases by a factor of up to 30 from the periphery towards the centre of the image. We then propose a method of noise equalization that depends upon spending longer collecting the smaller potentials than the larger potentials. The method is tested and shown to give an improvement in noise uniformity of about 16 dB.

Algorithms↗

Clinical applications of electrical impedance tomography in the monitoring of changes in intrathoracic fluid volumes.

We have previously shown that EIT can detect changes in intrathoracic fluid volumes in normal subjects undergoing a fluid challenge. We now report the preliminary results of two studies designed to investigate the ability of EIT to monitor changes in intrathoracic fluid in disease states. All recordings were made using the Sheffield Mark 1 system with the 16 electrode array placed around the lower thorax. Ten patients were studied during the sequential aspiration of unilateral pleural effusions. Following recording of a baseline dataset during tidal breathing (600 cycles) fluid was aspirated in 300 ml aliquots up to a maximum of 1000 ml, 600 cycles of data being collected after each aspiration. On the side of the effusion there was a progressive increase in intrathoracic resistivity in all patients as the fluid was aspirated. The mean increase in resistivity per 100 ml aspirated was 7%, range 3%-13%, p < 0.01 pre- versus post-aspiration resistivity. In the contralateral lung there was a smaller increase in all subjects (mean 1.8%, range 1%-3%) consistent with a reduction in mediastinal shift following aspiration. In these preliminary observations we have shown that EIT can be used in the clinical environment to detect small changes in intrathoracic fluid.

Adult↗

Cardiac and respiratory related electrical impedance changes in the human thorax.

Electrical impedance measurements have been made from the human trunk over the frequency range 9.6 kHz to 614 kHz. Measurements have been made from 12 normal subjects and the amplitude of the impedance changes associated with the cardiac and respiratory cycles have been recorded. It was found that the real part of the impedance fell to 64.0% of its low frequency value over the measured range of frequencies and that the changes associated with respiration fell in a similar manner. However, the cardiac related changes fell more rapidly with increasing frequency to 28.2% of the low frequency value. The origin of the measured changes is discussed with a view to understanding why the cardiac related changes fall more rapidly. It is not possible to relate in any simple way the frequency dispersion of a single component to that of the whole trunk. However, the results are consistent with the lungs being the major origin of both the cardiac and respiratory related components. The origin of the cardiac related impedance changes could be the pulsatile volume changes in the pulmonary tree. These could be shunted by nonpulsatile lung tissue that has decreasing impedance at high frequency and thus decreases the relative magnitude of the cardiac related changes. This hypothesis needs to be tested using localized measurements from the thorax and 3-D modeling of the trunk.

Adult↗

Vibrotactile and electrotactile perception of time-varying pulse trains.

To establish the best strategy for transmitting speech-derived information via a single tactile channel, measurements were made on the perception of frequency- and/or amplitude-modulated pulse-train stimuli, with a comparison of the electrotactile and vibrotactile modalities. In one experiment, vibrotactile perception of 2-oct step changes in stimulus frequency was found to be significantly better than electrotactile on a time-scale appropriate for the transmission of speech features (e.g., with practiced subjects, information transfer of 69% with 200-ms vibrotactile stimuli, 32% with 200-ms electrotactile stimuli). Perception of step changes in stimulus amplitude was similar in the two modalities when changes in amplitude were tailored to match the different dynamic ranges available. In a second experiment, vibrotactile-perception of voice fundamental frequency with various codings was investigated. Both experiments showed information transfer for vibrotactile stimuli to be greater when frequency and amplitude modulation were used together rather than with one or the other in isolation (sentence-stress identification scores: 66% for FM stimuli, 69% for AM stimuli, 80% for FM/AM stimuli). It is concluded that frequency- and amplitude-modulated vibratory stimulation is a good choice in a practical device for the profoundly hearing impaired.

Adolescent↗

Back-projection distortions in applied potential tomography images due to non-uniform reference conductivity distributions.

An investigation was conducted to determine and quantify the distortions in applied potential tomography (APT) images reconstructed from data originating from bodies of non-uniform reference conductivity distributions. The results show that the distortions in the images are dependent on the reference conductivity distribution and on whether the images are formed by back projection along the assumed equipotentials of a uniform reference conductivity distribution or along the equipotentials of the true conductivity distribution. We believe that this last finding is significant since our previously held expectation, similar to that of Yorkey and Webster (1987), that back projection along the true equipotentials of the reference conductivity distribution should result in an accurate reconstruction, is shown to be incorrect.

Electric Conductivity↗

Noise and spatial resolution of a real-time electrical impedance tomograph.

The Sheffield real-time electrical impedance tomograph produces 25 images per second, using 16 electrodes with adjacent-pair current drive and non-iterative image reconstruction. We describe the data acquisition timing of this instrument and present quantitative measurements of its signal-to-noise ratio and spatial resolution.

Electric Conductivity↗