Search PubMed⌕ Search

Biomedical subjects

B Golosio

Publications and source records attributed to B Golosio.

5 recordsLinked to original sources

Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy.

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detector allowed its use with a larger pinhole collimator than could be used with the CZT detector. Additionally, the improved pinhole collimator and alignment features of the apparatus permitted much more rapid setup for acquisition of x-ray spectra than was possible on the system described in the earlier work. These improvements in detector technology, collimation and ease of alignment, as well as low cost, make this apparatus attractive as a tool for both laboratory research and advanced mammography quality control.

Calibration↗

A Simulator for X-ray images.

A simulator for X-ray images is presented based on a virtual X-ray source and a virtual human body obtained from tomographic slices. In the simulator it is possible to modify the tube potential, the anodic current, the exposure time, the filtration and some geometric parameters such as source-skin distance, orientation and field size. The virtual body consists of a three-dimensional voxel matrix in which CT numbers for each point of the body are stored. The interactions of X rays passing through the body are evaluated using the pencil beam technique. The image is obtained by computing the dose absorbed by the detector and converting it into optical density using a proper response function. The image spatial resolution is limited by the voxel size. The influence of each parameter on the image quality can be observed interactively. The dose absorbed in each point of the body is an important parameter obtained as output of the simulator.

Computer Simulation↗

Direct analysis of molybdenum target generated x-ray spectra with a portable device.

In routine applications, information about the photon flux of x-ray tubes is obtained from exposure measurements and cataloged spectra. This approach relies mainly on the assumption that the real spectrum is correctly approximated by the cataloged one, once the main characteristics of the tube such as voltage, target material, anode angle, and filters are taken account of. In practice, all this information is not always available. Moreover, x-ray tubes with the same characteristics may have different spectra. We describe an apparatus that should be useful for quality control in hospitals and for characterizing new radiographic systems. The apparatus analyzes the spectrum generated by an x-ray mammographic unit. It is based on a commercial CZT produced by AMPTEK Inc. and a set of tungsten collimator disks. The electronics of the CZT are modified so as to obtain a faster response. The signal is digitized using an analog to digital converter with a sampling frequency of up to 20 MHz. The whole signal produced by the x-ray tube is acquired and analyzed off-line in order to accurately recognize pile-up events and reconstruct the emitted spectrum. The energy resolution has been determined using a calibrated x-ray source. Spectra were validated by comparison of the HVL measured using an ionization chamber.

Algorithms↗

A new algorithm for computer tomographic reconstruction from partial view projections.

Conventional algorithms for tomographic reconstruction require the acquisition of a complete set of projections at uniform angular displacements. In many cases, however, the geometry of the sample or a loss of data can significantly reduce the range of the available projections. Several algorithms have been proposed in literature to handle such situations, but their performances are low or they require strong constraints and hypothesis about the nature of the sample or the data. Here a new method is proposed. It is based on a novel morphing technique, which affords in general terms the problem of curve matching and is here specialized to the case of tomographic reconstruction. The proposed algorithm is very fast in comparison to other approaches having similar effectiveness; furthermore, it allows one to obtain good quality images even when a significant fraction of the views is absent, without any hypothesis about the nature of the sample or the kind of measurement. The results obtained by applying this technique to the Shepp-Logan phantom and to a clinical scan are reported here and discussed.

Algorithms↗

A real-time classification system of thalassemic pathologies based on artificial neural networks.

Thalassemias are pathologies that derive from genetic defects of the globin genes. The most common defects among the population affect the genes that are involved in the synthesis of alpha and beta chains. The main aspects of these pathologies are well explained from a biochemical and genetic point of view. The diagnosis is fundamentally based on hematologic and genetic tests. A genetic analysis is particularly important to determine the carriers of alpha-thalassemia, whose identification by means of the hematologic parameters is more difficult in comparison with heterozygotes for alpha-thalassemia. This work investigates the use of artificial neural networks (ANNs) for the classification of thalassemic pathologies using the hematologic parameters resulting from hemochromocytometric analysis only. Different combinations of ANNs are reported, which allow thalassemia carriers to be discriminated from normals with 94% classification accuracy, 92% sensitivity, and 95% specificity. On the basis of these results, an automated system that allows real-time support for diagnoses is proposed. The automated system interfaces a hemochromo analyzer to a simple PC.

Adolescent↗