Search PubMed⌕ Search

Biomedical subjects

B Gebauer

Publications and source records attributed to B Gebauer.

At least 19 recordsLinked to original sources

[Potential advantages of the MRI for the radiofrequency ablation of liver tumors].

PURPOSE: To present first results of radiofrequency ablation of liver tumors using a new MR compatible applicator. MATERIALS AND METHODS: We performed 37 interventions in 20 patients (mean age 58.6 years) with primary intrahepatic malignancies or metastases: colorectal carcinoma n = 6, hepatocellular carcinoma n = 3, pancreatic carcinoma n = 4, sarcoma n = 2, cholangiocellular carcinoma n = 1, carcinoma of the tonsil n = 1, breast carcinoma n = 1, gastric carcinoma n = 1, and gastrointestinal stroma tumor n = 1. Interventions were performed under CT-guidance with CT fluoroscopy (n = 32) and under MR-guidance (n = 5) using fast T1-weighted sequences in breath-hold technique. RFA was performed with the RF-generator (150 W) under local anesthesia and sedation using MR compatible applicators (Starburst XL, Rita Medical Systems, USA) together with the appropriate Soft Tissue Introducer System. Intra-interventional control was performed with intrahepatically or intralesionally placed introducer system or applicator. MRI was performed with plain breath-triggered T2-weighted turbo spin echo sequences (TSE T2) with fat saturation. RESULTS: All interventions were performed without major events. The mean diameter of induced coagulation was 4.0 (+/- 0.7) cm. Repositioning was necessary in 8 interventions (21 %) after detection of residual tumor on an intra-interventional MRI. After a mean follow-up of 6.5 (+/- 1.2) months, the local tumor control rate was 92 %. CONCLUSION: MR-compatible RF applicators offer the opportunity for intra-interventional detection of residual tumor during RF ablations by use of sensitive MRI sequences. These procedures may lead to a higher confidence in tumour ablation and may reduce the number of re-interventions and local recurrences of intrahepatic tumors.

Catheter Ablation↗

[Imaging modalities in the preoperative staging of rectal carcinoma].

Thorough clinical examination, endorectal ultrasound, and magnetic resonance tomography (MRI) are decisive tools in the pretherapeutic work-up of patients with rectal cancer. Depth of infiltration to the rectal wall as well as involvement of perirectal lymph nodes by the tumor are the key questions to be answered. To receive adequate information from imaging procedures, the right questions need to be asked. The extent of invasion of the rectal wall and exact location of tumor infiltration to neighboring structures can be demonstrated by MRI very well, particularly if imaging planes are acquired at 90 degrees to the position of the rectum. Recent developments in computed tomography (CT) using isotrope voxels allow three-dimensional reconstructions of tumors without loss of imaging quality. Assessment of the primary tumor and its nodal metastases after preoperative radio-(chemo-)therapy is still seriously limited. Fusion of positron emission tomography and CT could be a step towards solving the problem of response assessment in the near future.

Contrast Media↗

[Soft tissue sarcoma].

Soft tissue sarcomas are characterized by their heterogeneity. With new diagnostic imaging techniques, low- and high-grade components of the tumor can be differentiated. Thus biopsies should be guided by imaging to assure representative specimens. Besides histopathology, the advent of chromosomal and gene expression analysis may allow more accurate classification in the near future. Gene expression profiling has already proven its value by finding new subclassifications in other tumor types. Furthermore, this technique is a promissing tool to predict the response of a tumor to neoadjuvant and adjuvant therapy. Up to now, response evaluation in neoadjuvant therapy is based on tumor size and not on vital tumor cells. Newer techniques (i.e., Magnetic-resonance-Spectroscopy, Molecular Imaging) can show the change of metabolism in neoadjuvant therapy and allow objective, comparative measurement of biological activity. The diagnostic of soft tissue sarcomas implies primarily a multidisciplinary approach for a stage associated therapy.

Biopsy↗

[Ultrasound- and fluoroscopy-guided implantation of peripherally inserted central venous catheters (PICCs)].

PURPOSE: Evaluation of ultrasound- and fluoroscopy-guided implantation of peripherally inserted central venous catheters (PICCs). MATERIALS AND METHODS: In 32 patients (12 males, 20 females; mean age 64.1 +/- 11.9 years) with clinical indication for long term central venous catheter (chemotherapy: N = 5; parenteral nutrition and fluid substitution: N = 26; parenteral pain therapy: N = 1) a PICC was placed by an interventional radiologist using ultrasound guidance. RESULTS: The placement of the PICC was technically successful in 31 (96.9%) patients, with placement of 20 single-lumen 5F PICCs, 4 double-lumen 6F PICCs and 7 double-lumen 7F PICCs. The mean duration of catheter usage was 28.4 (2 - 161) days with a total of 910 catheter days. No catheter occlusions were recorded. Two patients developed a superficial venous thrombosis of the upper extremity. The resulting thrombotic rate was 2.2 per 1000 catheter days. No catheter associated infection was recorded. CONCLUSION: The ultrasound guided placement of peripherally inserted central venous catheters (PICCs) via a superficial vein of the upper extremity is a practical alternative to central catheters via central veins.

Adult↗

[Long-term central venous lines and their complications].

The implantation of permanent (> 14 days) central venous catheters is constantly increasing, accelerated by a trend toward outpatient therapies. Subcutaneous tunneled and non-tunneled catheters as well as port systems are available. The interventional radiologist plays an important role in the implantation of central venous catheters as well as in detection and treatment of any complications. Various access ways via peripheral and central veins are described and the implantation techniques for the different systems explained. The use of peel-away sheaths allows the radiologist to implant subcutaneous tunneled catheters via the Seldinger technique without surgical preparation. Procedure-related early and late complications may occur, and the radiologist plays an important role in the surveillance and management of catheter-associated complications. This review demonstrates the different catheter systems and implantation techniques.

Catheterization, Central Venous↗

New concepts of staging in gastrointestinal tumors as a basis of diagnosis and multimodal therapy.

The therapy of gastrointestinal tumors is becoming more and more sophisticated and complex. This is due to an improved understanding of the pathogenesis of tumors, a more detailed classification and increasing therapeutic options. The basis of optimized therapeutic concepts is the exact evaluation of tumor spread and exact staging. The following review describes some of the most recent staging concepts in gastrointestinal tumors. Multislice computed tomography (CT), positron emission tomography (PET) and new supraparamagnetic iron oxide contrast agents for magnetic resonance imaging enable an increasing quality of the visualization of tumors and metastases. 3D imaging will be used for planning of surgical interventions in the future. Optical coherence tomography may contribute to an improved tumor staging and, thus, to the safety of limited interventions in early oesophageal- and gastric cancer patients. Laparoscopy and laparoscopic ultrasound become increasingly important for the identification of small metastases in the peritoneum, in lymph nodes and in the liver. The sentinel lymph node concept will contribute to an improved staging and individualized therapy as well.

Combined Modality Therapy↗

[Use of SPIO-enhanced T1- and T2-weighted images for the differentiation of liver lesions: an ROC analysis].

PURPOSE: The superparamagnetic iron oxide (SPIO) Resovist is a contrast media with shortening of both T(1) and T(2) relaxation time. This study evaluates the impact of SPIO-enhanced T(1)- and T(2)-weighted images for the differentiation of liver lesions. MATERIALS AND METHODS: SPIO-enhanced MRI examinations (1.5 T, Symphony Quantum) of 61 patients were analyzed. Thirty-seven patients had malignant liver lesions (metastases n = 32, HCC n = 5) proven by biopsy or laparotomy, 11 patients had benign liver lesions (FNH n = 2, hemangiomas n = 4, benign cysts n = 5, normal liver on laparoscopy n = 13). After unenhanced T(1)- and T (2)-weighted imaging, a bolus injection of 1.4 ml SPIO (Resovist) was given, followed by T(1)-weighted imaging at 20 s, 60 s, and 5 min and T(2)-weighted imaging at 10 min post injection. A score from 1 (benign) to 5 (malignant) was used by three blinded radiologist for the ROC analysis of the unenhanced T(1)-/T(2)-weighted images (set 1) and of the combinations of unenhanced T(1)/T(2)-weighted and SPIO T(1)-weighted images (set 2), unenhanced T(1)/T(2) and SPIO T(2)-w images (set 3) and all images (set 4). RESULTS: The accuracy of plain MRI (set 1: 56 %) was increased by SPIO-enhanced T(1)-weighted images (set 2: 81 %) and SPIO-enhanced T(2)-weighted images (set 3: 90 %). Best results were obtained using unenhanced T(1)-weighted, unenhanced T(2)-weighted and both SPIO T(1)-weighted and T(2)-weighted images (set 4: 93%). The accuracy of predicting histopathologic diagnosis was 91%. CONCLUSION: For the differentiation of liver lesions, SPIO-enhanced T(2)-weighted images had a greater impact on the accuracy of MRI than T (1)-weighted images, but SPIO-enhanced T(1)-weighted images provided additional information in some patients and should not be deleted.

Adult↗

[Transjugular implantation of venous port catheter systems].

PURPOSE: Prospective analysis of success and complication rates of chest port implantation via the internal jugular vein. MATERIALS AND METHODS: In 50 consecutive patients (25 men, 25 women; mean age 61 +/- 14 years) the internal jugular vein was punctured under ultrasound guidance. Through this access, a port system was inserted and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted into a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n = 46), total parenteral nutrition (n = 2) or intravenous medication (n = 2). RESULTS: A chest port catheter system was successfully implanted in all 50 patients. The mean duration of placement was 90 +/- 65 catheter days. No complications occurred during implantation. In the post-interventional period a single catheter dysfunction occurred (0.22 per 1,000 catheter days). Two local infections occurred in the early post-interventional period (0.43 per 1,000 catheter days). One port system had to be explanted prematurely due to pain. CONCLUSION: The ultrasound guided puncture of the internal jugular vein enables a safe access for insertion of a central venous port catheter system and is associated with a very low complication rate. Port placement via this access vein should therefore be the primary treatment.

Adult↗

[Flexible applicator systems for radiofrequency ablation (RFA) of hepatic tumors].

PURPOSE: To report our experience with flexible applicators in radiofrequency ablation (RFA) of hepatic tumors. MATERIALS AND METHODS: In 6 liver tumors in 6 patients, a flexible RFA-applicator system (RITA StarBurst FLEX, RITA Medical Systems, Mountain View, CA, USA) was placed under CT guidance. The Seldinger technique with an 11G access system (RITA StarBurst Access) was used to place the application system into the liver. Before and within a week after the ablation, all tumors were investigated with contrast-enhanced MRI. RESULTS: The Seldinger technique accommodated the placement of a thin 17.5-gauge needle for the initial puncture, enabling easy adjustment of the position of the needle. The flexible applicator of the RFA system could be placed in 4.5 (+/- 1.8) minutes on average. CONCLUSION: Flexible applicators facilitate CT-guided RFA and can be placed using the Seldinger technique.

Carcinoma, Hepatocellular↗

Intraperitoneal distribution of ultrasound contrast medium imaged with B-mode ultrasound and colour-stimulated acoustic emission imaging.

Intraperitoneal port catheter systems for local delivery of cytotoxic drugs require imaging prior to chemotherapy to confirm homogenous distribution of an injected fluid in the entire peritoneal cavity. This study was performed to assess whether contrast-enhanced ultrasound (US) is a suitable imaging modality for this task. Twelve patients with peritoneal carcinosis and an implanted intraperitoneal port catheter system were studied before chemotherapy. Ultrasound examinations were performed after bolus injections of the microbubble contrast medium Levovist. Distribution of the contrast medium in the peritoneal cavity was imaged using B-mode US and colour-stimulated acoustic emission imaging (SAE). Contrast-enhanced CT imaging was used as term of reference for evaluating the US results. Distribution of the microbubbles in the peritoneal cavity was easily detected by both US methods. In 10 of 12 patients a free distribution in all abdominal quadrants was seen with both US techniques. In 2 of 12 patients, CT and US showed contrast medium limited to the perihepatic area. Therapy was stopped and surgical repositioning of the catheter was performed. Ultrasound after intraperitoneal injection of a microbubble contrast agent provides reliable information about the distribution of intraperitoneally injected fluid in the peritoneal cavity. This method is therefore well suited for imaging port catheter systems prior to chemotherapy.

Acoustics↗

Survey of conventional and spiral ct doses.

PURPOSE: To investigate the radiation dose for conventional computed tomography (CT) and spiral CT during different CT examinations at various hospitals and practices. MATERIALS AND METHODS: CT dose index with an active length of 15 cm was measured in 16 different types of CT scanners by using ionization chamber dosimetry. Twenty-six holders (one who has legal responsibility under national law for a radiologic installation) operating a total of seven conventional and 20 spiral CT scanners were asked for their standard parameters for various CT examinations. Weighted CT dose index and dose-length product were determined for each examination. RESULTS: For most examinations, the tube current time product was significantly higher for conventional CT than for spiral CT (.002 </= P </=.05). The ratio of section distance to section thickness for conventional CT was significantly lower than the pitch for spiral CT (.001 </= P </=.05). The weighted CT dose index and dose-length product for spiral CT were about half of those for conventional CT. The third quartiles for weighted CT dose index and dose-length product for spiral CT were much lower than those recommended as reference doses. CONCLUSION: CT examinations with conventional CT scanners are often performed with unnecessarily high radiation dose. For the establishment of reference doses, the radiation dose with spiral CT scanners should be taken into account.

Humans↗

[Multi-slice spiral CT: 3D CT angiography for evaluating therapeutically relevant stenosis in peripheral arterial occlusive disease].

PURPOSE: Evaluation of 3D multislice CT angiography for the assessment of relevant stenoses of pelvic arteries and arteries of the lower extremity in patients with peripheral artery occlusive disease compared to digital subtraction angiography. METHOD/MATERIALS: For this study we examined 31 patients with peripheral artery occlusive disease. All patients received a multislice helical CT angiography and arterial digital subtraction angiography. Multislice CT angiography was performed with a Somatom Plus 4 Volume Zoom (Siemens, Erlangen, Germany). After test bolus injection of 20 ml Ultravist 370 (Schering AG, Berlin) additional 150 ml were applied with a flow rate of 3 ml/sec and a scan delay between 20-35 sec depending on individual blood circulation time. Collimation was 4 x 2.5 mm with a pitch of 6. Reconstructed slice thickness was 3 mm. 3D reconstructions of arteries of pelvic and lower extremity arteries were performed in volume rendering technique on a 3D Virtuoso workstation (Siemens, Erlangen). RESULTS: For the assessment of therapeutically relevant stenoses (over 50% reduction of luminal diameter) multislice CT achieved the following results compared to conventional angiography for the diagnosis of stenosis: sensitivity of 86%, specificity of 86% and an accuracy of 72%. CONCLUSIONS: Multislice helical CT angiography of pelvic arteries and arteries of the thigh represents a reliable means for the detection of relevant stenoses in patients with peripheral occlusive artery disease.

Adult↗

Removal of detergent and solvent from solvent-detergent-treated immunoglobulins.

The solvent-detergent (S/D) method was applied for inactivation of lipid-enveloped viruses during the production of immunoglobulins. Amberlite XAD-7 resin was used for removal of solvent (tri-n-butyl phosphate, TnBP) and detergent (Triton X-100) after the performed S/D inactivation procedure. The S/D reagents from the immunoglobulin preparation were adsorbed on Amberlite XAD-7, while immunoglobulins passed through the column and retained their biological activity. Using the method developed here, the final immunoglobulin preparation contains less than 1 ppm of Triton X-100 and less than 2 ppm TnBP.

Acrylic Resins↗

Ion-exchange chromatography separation of the detergent and the solvent from immunoglobulins after solvent-detergent treatment.

For inactivation of lipid-enveloped viruses during the immunoglobulin production, the solvent-detergent (S/D) method was applied. Tri-n-butyl phosphate (solvent) and Triton X-100 (detergent) were removed from S/D treated immunoglobulins by ion-exchange chromatography on Q-Sepharose Fast Flow (FF). During the chromatographic procedure immunoglobulins remained bound on a Q-Sepharose FF, whereas solvent and detergent were eluted by washing with starting buffer. Elution of immunoglobulins was achieved by increasing the ionic strength of the starting buffer. The final immunoglobulin preparation contained less than 10 microg/ml of Triton X-100 and less than 2 microg/ml tri-n-butyl phosphate. It was confirmed that the S/D procedure did not cause a significant change in polymers and specific antibodies content. Immunoglobulin classes were also not affected by the same procedure.

Chromatography, Ion Exchange↗

Characterization of F VIII concentrates produced by two methods incorporating double virus inactivation.

The trend toward the production of high purity factor VIII concentrates for clinical use is still in progress. Although all plasma derivatives must undergo viral inactivation procedures, the possibility of transmission of viral diseases is not completely eliminated. In order to reduce such risk, we have included double virus inactivation in the procedure of factor VIII concentrate production. In a scale-up procedure for isolation of factor VIII cryoprecipitate, two methods were used. The first is based on the chromatographic purification of factor VIII after pasteurization of cryoprecipitate solution and solvent/detergent (S/D) inactivation of viruses. The second is based on multistep precipitation of factor VIII by sodium chloride and glycine. Viral inactivation was performed by combination of S/D treatment and heating of final freeze-dried product 30 min at 100 degrees C. The typical yield of factor VIII activity in the freeze-dried product was about 20% for the first method, and 25-30% for the second. Electrophoretic analyses of both factor VIII preparations by SDS-PAGE and IEF show very low content of contaminant proteins, in accordance with observed 400-650-fold increase of their specific activity over plasma. Both factor VIII products were stable in the liquid state for more than 24 h at room temperature. The final products, after double viral inactivation, are considered to be suitable for clinical evaluations.

Antiviral Agents↗