Search PubMed⌕ Search

Biomedical subjects

B F Hutton

Publications and source records attributed to B F Hutton.

56 records · Page 4Linked to original sources

Automatic detection of intradural spaces in MR images.

OBJECTIVE: An algorithm is presented for the automatic detection of intradural spaces in MR images of the human head. The primary motivation behind the present work has been to serve as a preprocessing step in automatic segmentation of brain tissue and CSF. A second objective was to use the algorithm in a fully automatic PET-MR registration algorithm. MATERIALS AND METHODS: The method is primarily designed for, and requires, dual echo (T1- and T2-weighted) MR images with transaxial orientations. The algorithm consists of three main stages. First, the head contour is detected using a series of low-level image-processing techniques. In the second stage, the pixels inside the head contour are clustered into a number of classes using the K-means algorithm. Finally, the extradural connected components are eliminated based on a number of heuristics. RESULTS: Test results are presented for 10 MR image sets consisting of 197 slices. As a quantitative measure of accuracy, manual segmentations were performed by radiologists on a number of slices and compared with the results obtained automatically. CONCLUSION: Visual inspection and quantitative validation of the results indicate that the algorithm accurately detects the intradural spaces in MR images. This is an important step in fully automatic segmentation and registration of MR images.

Algorithms↗

A fully automatic multimodality image registration algorithm.

OBJECTIVE: A fully automatic multimodality image registration algorithm is presented. The method is primarily designed for 3D registration of MR and PET images of the brain. However, it has also been successfully applied to CT-PET, MR-CT, and MR-SPECT registrations. MATERIALS AND METHODS: The head contour is detected on the MR image using a gradient threshold method. The head region in the MR image is then segmented into a set of connected components using the K-means clustering algorithm. When the two image sets are registered, the segmentation of the MR image indirectly generates a segmentation of the PET image. The best registration is taken to be the one that optimizes the segmentation induced on the PET image. In this article, the K-means minimum variance criterion is used as a cost function, and the optimization is performed using the method of coordinate descent. RESULTS: The algorithm was tested on 80 H2 15O PET and MR image pairs from 10 subjects. Qualitatively correct results were obtained in all cases. With use of external markers visible in both image modalities, the average registration error was estimated to be < 3 mm. CONCLUSION: The algorithm presented in this article requires no user interaction and can be applied to a wide range of registration problems. Quantitative and qualitative evaluations of the algorithm indicate a high degree of accuracy.

Algorithms↗