Numerical study of wavelength-swept semiconductor ring lasers: the role of refractive-index nonlinearities in semiconductor optical amplifiers and implications for biomedical imaging applications.

Recent results have demonstrated unprecedented wavelength-tuning speed and repetition rate performance of semiconductor ring lasers incorporating scanning filters. However, several unique operational characteristics of these lasers have not been adequately explained, and the lack of an accurate model has hindered optimization. We numerically investigated the characteristics of these sources, using a semiconductor optical amplifier (SOA) traveling-wave Langevin model, and found good agreement with experimental measurements. In particular, we explored the role of the SOA refractive-index nonlinearities in determining the intracavity frequency-shift-broadening and the emitted power dependence on scan speed and direction. Our model predicts both continuous-wave and pulse operation and shows a universal relationship between the output power of lasers that have different cavity lengths and the filter peak frequency shift per round trip, therefore revealing the advantage of short cavities for high-speed biomedical imaging.

Amplifiers, Electronic↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗

115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser.

We demonstrate an ultrahigh-speed wavelength-swept semiconductor laser using a polygon-based wavelength scanning filter. With a polygon rotational speed of 900 revolutions per second, a continuous wavelength tuning rate of 9200 nm/ms and a tuning repetition rate of 115 kHz were achieved. The wavelength tuning range of the laser was 80 nm centered at 1325 nm, and the average polarized output power was 23 mW.

Equipment Design↗

Double-clad fiber for endoscopy.

Endoscopes employing a single optical fiber may have advantages over conventional fiber-bundle or CCD array imaging techniques, including the potential for greater flexibility and miniaturization. Although single-mode fibers can provide superior resolution compared with multimode fibers, they are prone to increased speckle noise and suffer from limited optical throughput and reduced depth of field. We demonstrate the use of a double-clad fiber for single-mode illumination and multimode detection to achieve high-resolution, reduced-speckle imaging with high optical throughput and a large depth of field.

Endoscopes↗

Three-dimensional spectrally encoded imaging.

A method for three-dimensional surface measurements with phase-sensitive spectrally encoded imaging is demonstrated. Both transverse and depth information is transmitted through a single-mode optical fiber, allowing this scheme to be incorporated into a miniature probe. This approach is demonstrated by measurement of the profile of a lens surface and by three-dimensional imaging of the face of a small doll.

Fiber Optic Technology↗

High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter.

Ultrahigh-speed tuning of an extended-cavity semiconductor laser is demonstrated. The laser resonator comprises a unidirectional fiber-optic ring, a semiconductor optical amplifier as the gain medium, and a novel scanning filter based on a polygonal scanner. Variable tuning rates up to 1150 nm/ms (15.7-kHz repetition frequency) are demonstrated over a 70-nm wavelength span centered at 1.32 microm. This tuning rate is more than an order of magnitude faster than previously demonstrated and is facilitated in part by self-frequency shifting in the semiconductor optical amplifier. The instantaneous linewidth of the source is <0.1 nm for 9-mW cw output power and a low spontaneous-emission background of -80 dB.

Equipment Design↗

Speckle reduction in optical coherence tomography by "path length encoded" angular compounding.

Speckle, the dominant factor reducing image quality in optical coherence tomography (OCT), limits the ability to identify cellular structures that are essential for diagnosis of a variety of diseases. We describe a new high-speed method for implementing angular compounding by path length encoding (ACPE) for reducing speckle in OCT images. By averaging images obtained at different incident angles, with each image encoded by path length, ACPE maintains high-speed image acquisition and requires minimal modifications to OCT probe optics. ACPE images obtained from tissue phantoms and human skin in vivo demonstrate a qualitative improvement over traditional OCT and an increased SNR that correlates well with theory.

Algorithms↗

Evaluation of intracoronary stenting by intravascular optical coherence tomography.

BACKGROUND: Conventional contrast cineangiography and intravascular ultrasound (IVUS) provide a limited definition of vessel microstructure and are unable to evaluate dissection, tissue prolapse, and stent apposition on a size scale less than 100 micro m. OBJECTIVE: To evaluate the use of intravascular optical coherence tomography (OCT) to assess the coronary arteries in patients undergoing coronary stenting. METHODS: OCT was employed in patients having percutaneous coronary interventions. Images were obtained before initial balloon dilatation and following stent deployment, and were evaluated for vessel dissection, tissue prolapse, stent apposition, and stent asymmetry. IVUS images were obtained before OCT, using an automatic pull back device. RESULTS: 42 stents were imaged in 39 patients without complications. Dissection, prolapse, and incomplete stent apposition were observed more often with OCT than with IVUS. Vessel dissection was identified in eight stents by OCT and two by IVUS. Tissue prolapse was identified in 29 stents by OCT and 12 by IVUS; the extent of the prolapse (mean (SD)) was 242 (156) microm by OCT and 400 (100) microm by IVUS. Incomplete stent apposition was observed in seven stents by OCT and three by IVUS. Irregular strut separation was identified in 18 stents by both OCT and IVUS. CONCLUSIONS: Intracoronary OCT for monitoring stent deployment is feasible and provides superior contrast and resolution of arterial pathology than IVUS.

Adult↗

Diagnosis of specialized intestinal metaplasia by optical coherence tomography.

BACKGROUND AND AIMS: Optical coherence tomography (OCT) is an imaging technique that produces high-resolution cross-sectional images in vivo. The aim of this study was to establish the sensitivity and specificity of OCT for diagnosing specialized intestinal metaplasia (SIM). METHODS: OCT was used to image the stomach and esophagus of 121 patients. A total of 288 biopsy-correlated OCT images were acquired. OCT criteria for SIM were formulated by analyzing 75 images of SIM. The SIM image criteria were retrospectively tested by applying them to images of gastric, squamous, SIM, and cardiac epithelium. The criteria were then tested prospectively to determine the sensitivity and specificity of OCT for diagnosing SIM. RESULTS: OCT images of SIM are characterized by (1) absence of the layered structure of normal squamous epithelium and the vertical "pit and crypt" morphology of gastric mucosa, (2) disorganized architecture with inhomogeneous tissue contrast and an irregular mucosal surface, and (3) presence of submucosal glands. These criteria were 100% sensitive and 93% specific for SIM when applied retrospectively and 97% sensitive and 92% specific when tested prospectively. CONCLUSIONS: OCT is highly sensitive and specific for SIM and may aid in the diagnosis and surveillance of this preneoplastic lesion.

Adult↗

High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography.

BACKGROUND: Optical coherence tomography is a new, high spatial-resolution, cross-sectional imaging technique. We investigated the ability of optical coherence tomography to provide detailed images of subsurface structures in the upper gastrointestinal (GI) tract. METHODS: Optical coherence tomography was performed during routine upper GI endoscopy on 32 patients including 20 patients with Barrett's esophagus. An endoscopic mucosal biopsy was obtained immediately after imaging and was used for histopathologic correlation. RESULTS: Optical coherence tomography provided clear delineation of layers of the normal human esophagus extending from the epithelium to the longitudinal muscularis propria. Gastric mucosa was differentiated from esophageal mucosa, Barrett's esophagus was differentiated from normal esophageal mucosa, and esophageal adenocarcinoma was distinguished from normal esophagus and Barrett's esophagus. CONCLUSIONS: Optical coherence tomography allows visualization of the subsurface architectural morphology of the upper GI tract. The diagnostic information provided by this new imaging modality suggests that it may be a useful adjunct to endoscopy.

Anatomy, Cross-Sectional↗

Optical coherence tomography in the gastrointestinal tract.

Optical coherence tomography (OCT) is a high-resolution, cross-sectional optical imaging technique that allows in situ imaging of tissue by measuring back-reflected light. OCT provides images in real time with a resolution approaching that of conventional histopathology, but without the need for tissue removal. OCT imaging can be performed endoscopically to visualize gastrointestinal tissue using a fiberoptic catheter passed through the instrument channel of a conventional endoscope. The resolution of OCT allows visualization of the different layers of gastrointestinal epithelium and the differentiation of Barrett's epithelium from normal gastric and squamous mucosa. OCT has also been used to image esophageal adenocarcinoma and colonic polyps. Recent developments include Doppler OCT, spectroscopic OCT, and ultrahigh-resolution OCT, which can visualize nuclei within single cells. Although still in its infancy as a clinical tool, OCT currently provides high-resolution images over the same imaging depth as conventional mucosal biopsy, and may prove to be a useful and minimally invasive technique for evaluating gastrointestinal tissue, particularly for early neoplastic changes.

Digestive System↗

Porcine coronary imaging in vivo by optical coherence tomography.

OBJECTIVE: A high-resolution coronary artery imaging modality has the potential to address important diagnostic and management problems in cardiology. Optical coherence tomography (OCT) is a promising new optical imaging technique with a resolution of approximately 10 microm. The purpose of this study was to use a new OCT catheter to demonstrate the feasibility of performing OCT imaging of normal coronary arteries, intimal dissections, and deployed stents in vivo. METHODS AND RESULTS: Normal coronary arteries, intimal dissections, and stents were imaged in five swine with OCT and compared with intravascular ultrasound (IVUS). In the normal coronary arteries, visualization of all of the layers of the vessel wall was achieved with a saline flush, including the intima which was not identified by IVUS. Following dissection, detailed layered structures including intimal flaps, intimal defects, and disruption of the medial wall were visualized by OCT. IVUS failed to show clear evidence of intimal and medial disruption. Finally, the microanatomic relationships between stents and the vessel walls were clearly identified only by OCT. CONCLUSIONS: In this preliminary experiment, we have demonstrated that in vivo OCT imaging of normal coronary arteries, intimal dissections, and deployed stents is feasible, and allows identification of clinically relevant coronary artery morphology with high-resolution and contrast.

Animals↗

High resolution in vivo intra-arterial imaging with optical coherence tomography.

BACKGROUND: Optical coherence tomography (OCT) is a new method of catheter based micron scale imaging. OCT is analogous to ultrasound, measuring the intensity of backreflected infrared light rather than sound waves. OBJECTIVE: To demonstrate the ability of OCT to perform high resolution imaging of arterial tissue in vivo. METHODS: OCT imaging of the abdominal aorta of New Zealand white rabbits was performed using a 2.9 F OCT imaging catheter. Using an ultrashort pulse laser as a light source for imaging, an axial resolution of 10 micrometer was achieved. RESULTS: Imaging was performed at 4 frames/second and data were saved in either super VHS or digital format. Saline injections were required during imaging because of the signal attenuation caused by blood. Microstructure was sharply defined within the arterial wall and correlated with histology. Some motion artefacts were noted at 4 frames/second. CONCLUSIONS: In vivo imaging of the rabbit aorta was demonstrated at a source resolution of 10 micrometer, but required the displacement of blood with saline. The high resolution of OCT allows imaging to be performed near the resolution of histopathology, offering the potential to have an impact both on the identification of high risk plaques and the guidance of interventional procedures.

Animals↗

High resolution imaging of normal and osteoarthritic cartilage with optical coherence tomography.

OBJECTIVE: We describe optical coherence tomography (OCT), a high resolution micron scale imaging technology, for assessment of osteoarthritic articular cartilage microstructure. OCT is analogous to ultrasound, measuring the intensity of backreflected infrared light rather than acoustical waves. METHODS: OCT imaging was performed on over 100 sites on 20 normal and osteoarthritic cartilage specimens in vitro. RESULTS: Microstructures that were identified included fibrillations, fibrosis, cartilage thickness, and new bone growth at resolutions between 5 and 15 microm. In addition, the polarization sensitivity of imaging suggested a diagnostic role of polarization spectroscopy. CONCLUSION: OCT represents an attractive new technology for intraarticular imaging due to its high resolution (greater than any available clinical technology), ability to be integrated into small arthroscopes, compact portable design, and relatively low cost.

Arthrography↗

Two- and three-dimensional high-resolution imaging of the human oviduct with optical coherence tomography.

OBJECTIVE: To evaluate the feasibility of optical coherence tomography, a new method of micron-scale imaging, for high-resolution assessment of the oviduct. Optical coherence tomography is analogous to ultrasound except that it measures the backreflection of infrared light rather than acoustical waves. DESIGN: The ampulla of a human fallopian tube was imaged in vitro using optical coherence tomography. Images were generated in 2 and 3 dimensions. SETTING: University. PATIENT(S): Samples were obtained from women who had undergone hysterectomy for leiomyomatosis. INTERVENTION(S): None MAIN OUTCOME MEASURE(S): The ability to perform imaging on a micron scale, which is a level of resolution higher than that of any currently available clinical technology. RESULT(S): Two- and three-dimensional data sets of the reflectance of a human fallopian tube were acquired. A volume of 5 x 5 x 2.5 mm (length x width x depth) was scanned. The axial resolution was 11 microm, and the lateral resolution at the focus was 20 microm. The data sets showed detailed structures of the fallopian tube. CONCLUSION(S): Our ability to obtain micron-scale two- and three-dimensional images of an in vitro oviduct suggests that it may be possible to identify and surgically treat tubal causes of infertility.

Diagnostic Imaging↗

Optical biopsy in human pancreatobiliary tissue using optical coherence tomography.

Optical coherence tomography (OCT) is a new technique for performing high-resolution, cross-sectional tomographic imaging in human tissue. OCT is analogous to ultrasound B mode imaging except that it uses light rather than acoustical waves. As a result, OCT has over 10 times the resolution of currently available clinical high-resolution cross-sectional imaging technologies. In this work, we investigate the capability of OCT to differentiate the architectural morphology of pancreatobiliary tissues. Normal pancreatobiliary tissues, including the gallbladder, common bile duct, pancreatic duct, and pancreas were taken postmortem and imaged using OCT. Images were compared to corresponding histology to confirm tissue identity. Microstructure was delineated in different tissues, including tissue layers, glands, submucosal microvasculature, and pancreatic islets of Langerhans. The ability of OCT to provide high-resolution imaging of pancreatobiliary architectural morphology suggests the feasibility of using OCT as a powerful diagnostic endoscopic imaging technology to image early stages of pancreatobiliary disease.

Biliary Tract↗