Search PubMed⌕ Search

Biomedical subjects

B D Malhotra

Publications and source records attributed to B D Malhotra.

14 recordsLinked to original sources

Application of electrochemically prepared polypyrrole-polyvinyl sulphonate films to DNA biosensor.

Double stranded calf thymus deoxyribonucleic acid (DNA) was physisorbed onto polypyrrole-polyvinyl sulphonate (PPY-PVS) films electrochemically deposited onto indium-tin-oxide (ITO) coated glass plates. These DNA immobilized PPY-PVS films optimized for various conditions, such as polymerization potential, pH of buffer, DNA concentration and scan rate were characterized using Fourier-transform infrared (FT-IR) spectroscopy, atomic force microscopy (AFM) and cyclic voltammetry (CV) techniques, respectively. The amperometric response studies of these DNA/PPY-PVS electrodes were carried out as a function of 2-aminoantharcene (2-AA, 0.01-20 ppm) and o-chlorophenol (OCP, 0.1-30 ppm) concentration, respectively at 25 degrees C. The observed amperometric current arising due to oxidation of guanine in the DNA/PPY-PVS films decreased linearly with the increase in the concentration of 2-AA and OCP. It has been revealed that 10 ppm of 2-AA is sufficient to reduce the observed guanine oxidation peak current by approximately -95+/-10% as compared to the reported values. A 25 ppm of OCP was capable enough to reduce the guanine oxidation current to zero. These DNA/PPY-PVS electrodes were found to have a shelf life of about 4 months when stored at 25 degrees C.

Anthracenes↗

Lactose biosensor based on Langmuir-Blodgett films of poly(3-hexyl thiophene).

An amperometric lactose biosensor was developed by immobilizing lactase (EC 3.2.1.23) and galactose oxidase (GaO) (EC 1.1.3.9) in Langmuir-Blodgett (LB) films of poly(3-hexyl thiophene) (P3HT)/stearic acid (SA) for estimation of lactose in milk and its products to prevent "lactose intolerance". The enzyme immobilized LB film was used as working electrode and platinum as reference electrode. The enzyme electrodes show a linearity 1-6 g/dL of lactose and have a shelf life more than 120 days. The reusability of electrode was found ten times with 3% loss in current response. The enzyme electrode was characterized by Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and kinetic parameters such as pH, temperature and stability. The working electrode may be used for the estimation of lactose/galactose in food and biological fluids.

Animals↗

Poly-3-hexyl thiophene Langmuir-Blodgett films for application to glucose biosensor.

Langmuir-Blodgett films of poly(3-hexyl thiophene) have been prepared by simultaneous entrapment of glucose oxidase and transferred onto the indium-tin-oxide coated glass plates. The films have been characterized by FTIR spectroscopy and detailed response studies have been performed with respect to glucose concentration, temperature, and storage time. These P3HT/SA/GOX electrodes have been utilized for glucose estimation from 100-500 mg/dL by amperometric method. The electrodes have been found to have sensitivity of 0.75 nA/mg/dL detection limit of 50 mg/dL and shelf life of about 75 days at 4 degrees C.

Biosensing Techniques↗

Biosensor based on Langmuir-Blodgett films of poly(3-hexyl thiophene) for detection of galactose in human blood.

An amperometric biosensor was developed to estimate galactose in human blood serum. Monolayers of poly(3-hexyl thiophene) were placed on glass plates coated with indium tin oxide formed by dispensing a mixed solution of stearic acid in chloroform on to a water sub-phase. Galactose oxidase was mixed with poly(3-hexyl thiophene)/stearic acid in chloroform and dispensed on to the air-water interface of Langmuir-Blodgett trough. These monolayers were transferred on to glass plates which were used as working electrodes with platinum as a reference electrode. The amperometric galactose biosensor thus fabricated had a linear response from 0.05 to 0.5 g galactose l(-1) in blood serum. The normal level in blood is < 0.05 g galactose l(-1) in adults and 0-0.2 g galactose l(-1) in infants. In case of galactosemia, this increases to above 0.2 g galactose l(-1) in infants.

Adult↗

Application of polyaniline/sol-gel derived tetraethylorthosilicate films to an amperometric lactate biosensor.

The electrochemical entrapment of polyaniline (PANI) onto sol-gel derived tetraethylorthosilicate (TEOS) films deposited onto indium-tin-oxide (ITO) coated glass has been utilized for immobilization of lactate dehydrogenase (LDH). The performance of these sol-gel/PANI/LDH electrodes has been investigated as a function of the lactate concentration, applied potential, pH of the medium and interferents. The amperometric response of the electrodes under optimum conditions exhibited a linear relationship from 1 mM to 4 mM. An attempt has been made to extend the linearity up to 10 mM for lactate by coating an external layer of polyvinyl chloride (PVC) over the sol-gel/PANI/LDH electrodes with a correlation coefficient of 0.89. These sol-gel/PANI/LDH electrodes have a response time of about 60 s, a shelf life of about 8 weeks at 0-4 degrees C and have implications in a lactate biosensor.

Aniline Compounds↗

Application of conducting polymers to biosensors.

Recently, conducting polymers have attracted much interest in the development of biosensors. The electrically conducting polymers are known to possess numerous features, which allow them to act as excellent materials for immobilization of biomolecules and rapid electron transfer for the fabrication of efficient biosensors. In the present review an attempt has been made to describe the salient features of conducting polymers and their wide applications in health care, food industries, environmental monitoring etc.

Biosensing Techniques↗

Mediated biosensors.

Direct electrode transfer between enzyme and the electrode in biosensors requires high efficiency therefore, synthetic replacement for oxygen led to the development of enzyme mediators and modified electrodes in biosensor fabrication. In this context, a number of electron acceptors and complexes have been used. Present paper gives an overview of various methodologies involved in the mediated systems, their merits and wide applications.

Biosensing Techniques↗

Immobilization of urease on poly(N-vinyl carbazole)/stearic acid Langmuir-Blodgett films for application to urea biosensor.

Urease was immobilized in mixed monolayers of poly(N-vinyl carbazole) (PNVK) and stearic acid (SA) formed at an air-water interface. The monolayers were transferred onto indium-tin-oxide (ITO) coated glass plates using Langmuir-Blodgett (LB) film deposition technique. Urease immobilized on PNVK/SA LB films, characterized using FTIR and UV-visible spectroscopy, was found to exhibit increased stability over a wide pH (6.5-8.5) and temperature (25-50 degrees C) range. Potentiometric measurements on these urease electrodes were carried out using an ammonium ion analyzer. Two values for K(m)(app) were obtained at lower and higher concentrations of substrate urea.

Biosensing Techniques↗

Synthesis and characterization of fluoro-substituted polyaniline.

Poly(2-fluoroaniline) was prepared by both chemical and electrochemical polymerization in acidic medium. Characterization of poly(2-fluoroaniline) was accomplished experimentally using ultraviolet-visible, Fourier transform infrared, differential scanning calorimetry, thermal gravimetric analysis, and X-ray diffraction techniques, respectively. Scanning electron microscopy studies revealed globular morphology of chemically synthesized poly(2-fluoroaniline). The cyclic voltammetric studies revealed diffusion-controlled phenomenon in electrochemically synthesized poly(2-fluoroaniline).

Aniline Compounds↗

Coimmobilization of urease and glutamate dehydrogenase in electrochemically prepared polypyrrole-polyvinyl sulfonate films.

Immobilization of urease and glutamate dehydrogenase enzymes in electrochemically prepared polypyrrole-polyvinyl sulfonate films (PPY-PVS) was carried out using physical adsorption and electrochemical entrapment techniques. Detailed studies on optimum pH, Fourier transform infrared spectroscopy, cyclic voltammetry, and scanning electron microscopy of the enzymes in the immobilized state were conducted. The value of the apparent Michaelis-Menten constant was experimentally determined to be 2.5 and 2.7 for physically adsorbed and electrochemically entrapped urease in PPY-PVS films, respectively.

Biosensing Techniques↗

Characterization of DNA immobilized on electrochemically prepared conducting polypyrrole-polyvinyl sulfonate films.

The article describes the adsorption characteristics of DNA onto electrochemically generated polypyrrole-polyvinyl sulfonate (PPY-PVS) films obtained as a function of pH. Adsorption on PPY doped with an anion proceeds by anion exchange, and since DNA possesses a fixed negative charge owing to PO4-, it favors a very strong binding displacing PVS with favorable energetic interactions. Characterization of adsorbed DNA onto the PPY-PVS films was carried out by ultraviolet-visible, Fourier transform infrared spectroscopy, and cyclic voltammetric studies.

Adsorption↗

Immobilization of lactate dehydrogenase on tetraethylorthosilicate-derived sol-gel films for application to lactate biosensor.

Tetraethylorthosilicate (TEOS)-derived sol-gel films were utilized for the immobilization of lactate dehydrogenase (LDH) by physical adsorption and sol-gel/LDH/sol-gel sandwich configuration. An attempt was made to ascertain the optimum pH and temperature for the immobilized LDH. It was shown that TEOS-derived sol-gel films containing physically adsorbed LDH exhibited linearity from 0.5 to 4 mM, whereas those containing LDH in sandwich configuration showed linearity from 0.5 to 3 mM L-lactate. These sol-gel films, immobilized with LDH, were found to be stable for about 4 weeks at 4-10 degrees C.

Adsorption↗