Search PubMed⌕ Search

Biomedical subjects

B Carter

Publications and source records attributed to B Carter.

At least 37 records · Page 2Linked to original sources

Novel retinoid-related molecules as apoptosis inducers and effective inhibitors of human lung cancer cells in vivo.

Lung cancer causes more than 140,000 deaths annually in the United States alone, and the prognosis for non-small cell lung cancer (NSCLC) is particularly poor. Therapies using small molecules that preferentially kill lung tumor cells by inducing cellular suicide (apoptosis) would therefore be highly desirable. Retinoids have shown promise as cancer preventive and cancer therapeutic agents. Retinoid signals are mediated by two classes of nuclear receptors: the retinoic acid receptors (RAR alpha, beta, and gamma) and the retinoid X receptors (RXR alpha, beta and gamma). These receptors usually bind as heterodimers to specific DNA sequences and/or interact with other transcriptional regulators, such as AP-1 (ref. 10) to regulate gene transcription. Synthetic retinoids can be made that activate only specific portions of the complex retinoid response network and activate selective biological programs. To identify retinoids with novel biological activities, we used a high-throughput "biological activity fingerprint" screen on a large library of retinoids and retinoid-related molecules (RRMs). We identified new structures that are highly effective against lung cancer cells in vitro, inducing apoptosis. We show here for one of these compounds that it is very effective against a human NSCLC in vivo in an animal model. These new molecules show a distinct pattern of receptor signaling.

Animals↗

Cricoid pressure: teaching the recommended level.

The Sellick maneuver or cricoid pressure is an effective means of preventing passive aspiration of gastric contents. Recent studies recommend a pressure of 20 newtons (N) when the patient is awake, increasing to 30-40 N with unconsciousness. This study was proposed to determine whether with education and practice, anesthesia providers and assistants could be taught a recommended cricoid pressure and retain this skill. Cricoid force was measured using a life-size laryngotracheal model on a calibrated infant scale. Fifty-three participants were divided into six groups: MD faculty; CA-1, 2, and 3 Residents; certified registered nurse anesthetists (CRNA); and Others. Each was asked to apply pressure to the blinded model to simulate application of the Sellick's maneuver to an "awake" and "unconscious" patient on four occasions: before instruction of the recommended pressures (Preinstruction), after being informed of the recommended magnitudes of 20 N/awake and 30-40 N/anesthetized (Postinstruction), after a period of unblinded practice (Postpractice), and 3 mo or longer after practice (Follow-up). Initial attempts revealed inadequate force by all participants, "awake" and "anesthetized". All participants were able to learn the recommended amount of applied pressure and were able to retain this knowledge after 3 mo. This model represents an easy and practical means of teaching the application of the optimal level of force to practitioners and assistants.

Analysis of Variance↗

The essence of enduring and expressions of suffering: the reformulation of self.

In this study, biographical narratives of illness experiences were used to explicate the concepts of suffering and enduring. Three types of enduring were identified: enduring to survive (which occurs during physiological jeopardy), enduring to live (which occurs with untenable psychological stressors), and enduring to die (which occurs with inevitable degenerative and terminal disease). Suffering is defined as an emotional response to that which was endured, to the changed present, or to anticipating the altered future. Finally characteristics that differentiate enduring from suffering are delineated. The relationships between the two concepts are explored. Individuals move from enduring to suffering when they are able to acknowledge that which is being endured, and when they are emotionally strong enough to experience the emotional onslaught of suffering. If the latter is overwhelming, individuals may retreat to enduring. Once they have suffered enough and are able to accept the changed reality, individuals gain new insight and appreciation for life as a reformulated self.

Acute Disease↗

Characterization of TrkB receptor-mediated signaling pathways in rat cerebellar granule neurons: involvement of protein kinase C in neuronal survival.

TrkB belongs to the Trk family of tyrosine kinase receptors and mediates the response to brain-derived neurotrophic factor (BDNF) and neurotrophin-4/5 (NT-4/5). Here, we report that both truncated and full-length forms of TrkB receptors are expressed in developing cerebellar granule neurons. BDNF and NT-4/5 increased the survival of cultured cerebellar granule neurons. BDNF and NT-4/5 also induced an autophosphorylation of TrkB receptors and subsequently resulted in a phosphorylation and binding of phospholipase C-gamma (PLC-gamma) and SH2-containing sequence to the autophosphorylated TrkB receptors. Both contain src homology 2 (SH2) regions. In keeping with a signaling function of PLC-gamma, BDNF increased the phosphatidylinositol (PI) turnover and elevated intracellular calcium levels. To investigate the involvement of protein kinase C (PKC) in the survival of granular neurons, we show here activation of PKC after BDNF or TPA treatment and blocking of the observed survival-promoting effects of BDNF and TPA with calphostin C, a specific PKC inhibitor. In addition, BDNF activated c-ras in a concentration-dependent manner. These results suggest that two different pathways, the c-ras and the PLC-gamma pathway, are activated by TrkB receptors in primary neurons and that PKC activation is involved in the survival promoting effect of BDNF.

Animals↗

A comparison of two transcutaneous monitors for the measurement of arterial PO2 and PCO2 in neonates.

We examined the ability of two transcutaneous devices (Fastrac, Sensormedics Corporation, Yorba Linda, California, U.S.A. and Hewlett Packard M1018A, Hewlett Packard Component Monitoring System, Hewlett Packard, North Hollywood, U.S.A.) to measure arterial PCO2 and PO2 in neonates. Thirty-seven neonates had transcutaneous oxygen measured with the Hewlett Packard (HPO2 group), 38 neonates had transcutaneous carbon dioxide measured with the Hewlett Packard (HPCO2 group) and the Fastrac was used on 27 neonates (FTCO2 group). Both devices were operated with electrode temperatures of 43.5 degrees C although an additional ten subjects were studied using the Fastrac with an electrode temperature of 43.0 degrees C. The mean differences (transcutaneous--arterial) and upper and lower limits of agreement were calculated for each group. For the HPO2 group they were 3.78 mmHg (-12.23 to 19.80 mmHg), for the HPCO2 group they were 0.40 mmHg (-4.50 to 5.30 mmHg) and for the FTCO2 they were -0.96 mmHg (-7.85 to 5.92 mmHg). For the Fastrac group at an electrode temperature of 43.0 degrees C the mean difference and limits of agreement were -1.00 mmHg and -4.58 mmHg to 2.58 mmHg. The average sensitivity and specificity for both machines for the detection of hypocarbia were 82% and 92% respectively while for hypercarbia they were 90% and 94% respectively. For hypoxaemia, the sensitivity and specificity were 40% and 94% while for hyperoxaemia the sensitivity and specificity were 83% and 97%. We conclude that both machines provide a useful supplement to arterial PCO2 measurements and the Fastrac performs better at 43.0 degrees C. The measurement of PO2 is less accurate but is still of clinical use.

Blood Gas Monitoring, Transcutaneous↗

An alarm for monitoring CPAP.

We have built a device for use within the hospital and at home that is designed to warn of circuit disconnection when used in conjunction with continuous positive airway pressure (CPAP) therapy delivered via ventilators or CPAP generating systems. The Royal Children's Hospital CPAP alarm is a compact, battery operated alarm and monitor of circuit pressure. The device includes intrinsic safety features including a safety blow-off valve, a high pressure alarm and design features that make the device practical, safe and easy to use by both trained hospital personnel and home care attendants with limited training.

Equipment Design↗