Search PubMed⌕ Search

Biomedical subjects

B Cancho-Grande

Publications and source records attributed to B Cancho-Grande.

8 recordsLinked to original sources

Determination of pesticides by solid phase extraction followed by gas chromatography with nitrogen-phosphorous detection in natural water and comparison with solvent drop microextraction.

The European Union specifies that drinking water can contain pesticide residues at concentrations of up to 0.1 microg/L each and 0.5 microg/L in total, and that 1-3 microg/L of pesticides can be present in surface water, but the general idea is to keep discharges, emissions and losses of priority hazardous substances close to zero for synthetic substances. Therefore, in order to monitor pesticide levels in water, analytical methods with low quantification limits are required. The method proposed here is based on solid phase extraction (SPE) followed by gas chromatography with a nitrogen-phosphorous detector (GC-NPD). During method development, six organophosphate pesticides (azinphos-ethyl, chlorfenvinphos, chlorpyriphos, ethoprophos, fenamiphos and malathion) and two organonitrogen pesticides (alachlor and deltamethrin) were considered as target analytes. Elution conditions that could influence the efficiency of the SPE were studied. The optimized methodology exhibited good linearity, with determination coefficients of better than 0.996. The analytical recovery for the target analytes ranged from 70 to 100%, while the within-day precision was 4.0-11.5%. The data also showed that the nature of the aqueous matrice (ultrapure, surface or drinking water) had no significant effect on the recovery. The quantification limits for the analytes were found to be 0.01-0.13 microg/L (except for deltamethrin, which was 1.0 microg/L). The present methodology is easy, rapid and gives better sensitivity than solvent drop microextraction for the determination of organonitrogen and organophosphate pesticides in drinking water at levels associated with the legislation.

Chromatography, Gas↗

Occurrence of organochlorine pesticides in stream sediments from an industrial area.

Contaminated stream sediments are a serious problem because contaminant residues will be persistent for a long time. Organochlorine pesticides (OCPs) were screened in stream sediments collected along stream flows close to an industrial area in northwestern Spain. Analyses were performed by extraction with organic solvents followed by gas chromatography-mass spectrometry detection. OCPs such as hexachlorobenzene, hexachlorocyclohexane (alpha and beta isomers) and DDT were detected at levels ranging between 29 and 392 microg/kg indicating there is a moderate to severe pollution in the area even though they were banned a few decades ago.

Agriculture↗

Stirring bar sorptive extraction in the determination of PAHs in drinking waters.

The application of a new extraction technique which is known as stir bar sorptive extraction (SBSE), followed by high-performance liquid chromatography with a fluorescence detector, was assessed for determining eight polycyclic aromatic hydrocarbons (PAHs) in water samples. The extraction conditions such as acetonitrile addition; effects of temperature and salt; and finally, extraction and desorption time profiles were studied. Once SBSE was optimized, analytical method parameters such as linearity (r(2)>0.991), precision (<9%), detection (0.5-7.3 ng/L) and quantitation (1.0-22 ng/L) limits were estimated. To correct for the 43-57% absolute recovery depending on the PAH, calibration was done with a line obtained submitting standard-spiked blank tap waters to the complete sample treatment and analysis. Consequently, relative recovery was about 100% because all water samples (those for calibration purposes and those for recovery estimation) were processed in the same way and the absolute recovery remained constant. SBSE method characteristics were checked with the analysis of real drinking waters in the search for PAHs.

Adsorption↗

Application of single-drop microextraction and comparison with solid-phase microextraction and solid-phase extraction for the determination of alpha- and beta-endosulfan in water samples by gas chromatography-electron-capture detection.

Water contamination due to the wide variety of pesticides used in agriculture practices is a global environmental pollution problem. The 98/83 European Directive requires the measurement of pesticides residues at a target concentration of 1.0 microg/l in surface water and 0.1 microg/l in drinking water. In order to reach the level of detection required, efficient extraction techniques are necessary. The application of a new extraction technique: single-drop microextraction (SDME), followed by gas chromatography with electron-capture detection, was assessed for determining alpha-endosulfan and beta-endosulfan in water samples. Experimental parameters which control the performance of SDME, such as selection of microextraction solvent and internal standard, optimization of organic drop volume, effects of sample stirring, temperature and salt addition, and sorption time profiles were studied. Once SDME was optimized, analytical parameters such as linearity, precision, detection and quantitation limits, plus matrix effects were evaluated. The SDME method was compared with solid-phase microextraction and solid-phase extraction with the aim of selecting the most appropriate method for a certain application.

Chromatography, Gas↗

HPLC method for determining ethylenediamine migration from epoxy-amine food packaging coatings into EU food simulants.

A simple, rapid, sensitive and inexpensive method has been developed for the determination of ethylenediamine (EDA) in European Union food simulants. The method involves precolumn derivatization with ortho-phthaldehyde (OPA) and 2-mercaptoethanol (ME) to obtain a fluorescent derivative. Liquid chromatographic (HPLC) elution was achieved with methanol-ultrapure water (65:35) as mobile phase with a Waters Spherisorb 5 microm ODS 2 column. Fluorescence detection (FD) was performed at 330 nm (excitation wavelength) and 450 nm (emission). Total chromatographic analysis time was < 10 min. The proposed method was validated by checking linearity, detection and quantification limits, and precision. Relative recovery rates were of about 100% because samples and standard-spiked blanks were processed in the same way. Method precision (RSD < 6%) was satisfactory and the quantification limit (0.25 mg x (-1)) indicated that specific migration limit for EDA in EU food simulants (12 mg x kg(-1)) can be easily controlled. When the validated method was applied to epoxy-amine formulations used for can coatings under different curing conditions, EDA migration was < 1.4 mg x l(-1).

Acetic Acid↗

Optimization of solid-phase extraction and solid-phase microextraction for the determination of alpha- and beta-endosulfan in water by gas chromatography-electron-capture detection.

Water contamination due to the wide variety of pesticides used in agriculture practices is a global environmental pollution problem. The 98/83/European Directive requires to measure residues of pesticides at a target concentration of 1.0 microg/l in surface water and 0.1 microg/l in drinking water. In order to reach the level of detection required, efficient extraction techniques are required. Although solid-phase extraction (SPE) is the most common technique for isolation and concentration of pesticides from water, solid-phase microextraction (SPME) is being increasingly applied for this purpose. In this study, a direct-SPME procedure has been developed for the determination of alpha-endosulfan and beta-endosulfan in waters; experimental parameters such as selection of SPME coating, effect of temperature, effect of salt addition, optimization of the sample volume, adsorption and desorption profiles and desorption temperature were studied and optimized. Analytical parameters such as linearity, precision, detection and quantitation limits, and matrix effects for SPE and SPME methods were evaluated for comparison purposes with the aim of selecting the most appropriate for a certain application. Both extraction techniques, SPE and SPME, were followed by gas chromatography with electron-capture detector.

Chromatography, Gas↗

Comparison of solid-phase extraction and solid-phase microextraction for carbofuran in water analyzed by high-performance liquid chromatography-photodiode-array detection.

In this study a direct solid-phase microextraction (SPME) procedure has been developed for the determination of carbofuran in water. Experimental parameters such as selection of SPME coating, effect of temperature, effect of salt addition and solvent desorption were studied and optimized. Analytical parameters such as linearity, precision, detection and quantitation limits, and matrix effects for solid-phase extraction (SPE) and SPME methods were evaluated for comparison purposes with the aim of selecting the most appropriate depending on the detection capabilities required. SPE and SPME were followed by high-performance liquid chromatography with diode-array detection, using a 50 x 4.6 mm I.D. guard column and a 150 x 4.6 mm I.D. analytical column, both packed with C18 silica. Both methods can be applied to real samples and give the same results, but SPE allows the detection of lower carbofuran concentrations (0.06 microg/L) as compared to

Carbofuran↗