Search PubMed⌕ Search

Biomedical subjects

B Canaud

Publications and source records attributed to B Canaud.

At least 55 records · Page 3Linked to original sources

[Kinetic modeling of LDL oxidation using software (NELOP program) and validation in a population at vascular risk].

Oxidized LDL (low density lipoprotein) are considered to be the major initiating event in atherogenesis. In vitro models have been studied but no mathematic modeling can assess quantitatively the oxidability of LDL and antioxidant effects. We have developed a mathematic modeling allowing quantification of different kinetic parameters to LDL oxidation. This model has been validated by means of a software (software NELOP) in normal population (HV) and in a cardiovascular risk population, hemodialysis (HD). LDL are collected and purified by sequential ultracentrifugations from 12 healthy volunteers and hemodialysis patients. LDL oxidability (0.1 microM) is initiated by 5 microM copper and monitored continuously by conjugated diene production. All parameters are evaluated and correlated to those obtained by NELOP. Significant correlations between measured and calculated parameters (Vmax: r2 = 0.99, p < 0.05) allow to validate NELOP in both populations. Our results show that hemodialysis LDL present an enhanced susceptibility to copper induced oxidation (lag time: 96.6 +/- 48.6 mn in HV versus 54.5 +/- 22.2 mn in HD). NELOP seems to be a useful tool to evaluate LDL oxidation in cardiovascular risk populations.

Aged↗

Evaluation of high-flux hemodiafiltration efficiency using an on-line urea monitor.

On-line urea monitoring of the effluent dialysate offers a real-time assessment of dialysis efficiency and metabolic/nutritional characteristics of hemodialysis patients. Quantitative parameters were evaluated by dialysate urea kinetic modeling (DUKM) with an on-line urea sensor in 23 patients treated by high-flux hemodiafiltration (HDF) (215 sessions of 210 to 240 minutes with a mean blood flow rate of 367 +/- 44 mL/min). Overall, the mean effective Kt/V was 1.52 +/- 0.29, the urea mass removed (22.8 +/- 5.5 g/session or 814 +/- 198 mmol/session), the solute removal index (SRI) 73% +/- 6.1%, and the mean normalized protein catabolic rate (nPCR), 1.15 +/- 0.31 g/kg/day. Blood urea kinetic modeling (BUKM), based on pre- and postsession urea concentrations, using equations from Daugirdas and Garred to calculate equilibrated Kt/V and nPCR, respectively, were in good agreement with DUKM, the differences observed appearing not clinically relevant. The variability of evaluated parameters was verified over consecutive sessions for a mean period of 3 weeks in the entire group. Mean variation in Kt/V was 8%; in urea mass removal, 18%; and in nPCR, 18%. When assessed over 1 week in a subgroup of 13 patients, Kt/V and PCR remained relatively stable, and urea mass removal per- and postsession declined from 23.5 +/- 8.0 g (840 +/- 285 mmol) to 18.7 +/- 6.3 g (667 +/- 225 mmol) from the first to the third session of the week, most likely as a consequence of interdialytic intervals. Predialysis urea concentrations followed the same trend. In the current study, DUKM with on-line urea sensor has confirmed that HDF is a highly efficient renal replacement modality; the variability observed in quantitative parameters supports a need for frequent adequacy monitoring. On-line urea monitoring of effluent dialysate is a simple device that provides the opportunity to tailor treatment to patient needs.

Blood Urea Nitrogen↗

Effective blood flow and recirculation rates in internal jugular vein twin catheters: measurement by ultrasound velocity dilution.

The ultrasound dilution technology (Transonic Systems, Ithaca, NY) is a reliable method to assess blood flow (Qb) and recirculation rates (R) in vascular access during hemodialysis. However, the information available on these parameters for central venous dialysis catheters remains scarce at this point. Real Qb and R were evaluated in 33 well-functioning TwinCath (Medcomp, Harleysville, PA) inserted as mid- or long-term hemodialysis vascular access (mean duration since insertion, 270 +/- 253 days); all were implanted into the right internal jugular vein with their multiperforated distal tips located in the superior vena cava or right atrium. Several types of dialysis machines were used (Monitral and AK100, Hospal-Gambro, Lyon, France; 2008E and 4008E, Fresenius, Bad Homburg, Germany). Real Qb was measured with the ultrasound dilution method and compared with the set Qb (indicated by the dialysis machine); R, also evaluated by ultrasound dilution, was evaluated at various Qb with nonreversed lines; therefore, a total of 121 measures were performed. Arterial and venous pressures (PA and PV) were recorded simultaneously. The 33 measures at a set Qb of 200 mL/min showed a mean effective Qb of 210 +/- 18 mL/min and a mean R of 5.3 +/- 5.3%. At a Qb of 300 mL/min, 33 repeated measures resulted in mean effective Qb of 303 +/- 21 mL/min and R of 8.5 +/- 7.0%; 28 measures performed at a set Qb of 350 mL/min showed that the effective Qb was 336 +/- 24 mL/min and that R was 7.8% +/- 6.7%. Finally, an effective Qb of 372 +/- 26 mL/min and an R of 10.9 +/- 8.6% were found for the 27 measures performed at an indicated Qb of 400 mL/min. The difference between indicated and effective Qb was particularly significant for set Qb equal to or above 350 mL/min (P < 0.001). Variable correlations were observed between obtained parameters: Qb eff and R (r = 0.34), PV and R (r = 0.36), Qb eff and PV (r = 0.78), Qb eff and PA (r = 0.71), and PV and PA (r = 0.53). In conclusion, TwinCath delivers an effective Qb of nearly 375 mL/min when Qb is set at 400 mL/min on most dialysis machines. Mean R in TwinCath varies between 5% and 11% for Qb within the range of 200 to 400 mL/min. In well-functioning TwinCath, the ratio between PV and Qb remains usually below 0.5.

Catheterization, Central Venous↗

On-line haemodiafiltration: state of the art.

Faced with the shortcomings of conventional dialysis on a long-term basis, as illustrated by the dialysis-related pathology, a need for a new strategy exists to improve the overall quality of treatment in end-stage renal failure (ESRF) patients. On-line haemodiafiltration (HDF) seems to be the best therapeutic option to achieve this goal at the present time. By enhancing convective clearances through highly permeable membranes, HDF offers the greatest solute fluxes both for low and higher molecular weight uraemic toxins. As for example, in our routinely performed HDF programme based on 3 weekly sessions lasting 3-4 h each, double-pool urea Kt/V achieved was 1.55+/-0.20 and beta2-microglobulin Kt/V was 0.91. By producing substitution fluid from fresh dialysate, the technique of HDF is simplified and becomes economically affordable. By improving the haemodynamic tolerance, HDF allows more elderly and high risk cardiovascular patients to be treated more safely. By using bicarbonate-buffered infusate, HDF facilitates the correction of acidosis. Both by using ultrapure bicarbonate dialysate and down-regulating the membrane reactivity via a 'protein cake', HDF introduces the first step for a full haemocompatibility concept. Finally, by giving access to virtually unlimited amounts of sterile and non-pyrogenic fluid, HDF should introduce new therapeutic options such as a totally automated and feed-back-controlled machine. Today's on-line HDF is already a step forward to enhance the overall efficacy of renal replacement therapy and to improve the global care of ESRF patients.

Hemodiafiltration↗

Temporary vascular access for extracorporeal renal replacement therapies in acute renal failure patients.

Temporary vascular access is an essential component to perform any extracorporeal renal replacement therapy (RRT) in the acute renal failure patient. RRT used in the acute setting may be categorized in two groups: intermittent (IRRT) and continuous (CRRT). Therapeutic indications are based on clinical and technical considerations. Continuous modalities are mainly utilized in intensive care units for hemodynamically compromised patient. Initially performed spontaneously via an arteriovenous circuit, CRRT modalities have progressively become venovenous with the circulatory assistance of a blood pump. Since both intermittent and continuous RRT modalities are now performed almost exclusively by venovenous modalities, this article deals exclusively with temporary venous catheters. At present, double-lumen catheters represent the most common vascular access for RRT modalities. Semi-rigid polyurethane catheters currently used in case of emergency are limited to short term use. Hemocompatible, flexible silicone catheters, less aggressive for the vessels, seem better suited for the medium and long term run. The tunneled silicone catheters (DualCath type) meet the short and long term needs, and allow for blood flow rates up to 400 ml/min. The internal jugular vein, particularly the right one, seems to warrant the proper functioning of catheters while reducing the risk of stenotic complications. Subclavian access should be limited in time and reserved for silicone catheters in order to limit the risk of stenosis and/or thrombosis. Femoral access, very useful in cases of emergency and respiratory problems, greatly impairs the patient's mobility and should be limited by time to prevent thrombosis and/or infection. Late and/or delayed dysfunctioning of catheters are indicative of a thrombosis. Performance standards of catheters are less of a limiting factor in continuous low flow RRT modalities than in the intermittent ones. Finally, careful handling of the catheter essential to prevent infectious complications.

Acute Kidney Injury↗

[Acute renal insufficiency: nutrition disorders and therapeutic consequences].

Catabolism is usually enhanced in acute renal failure (ARF). Its magnitude varies from one patient to another and can change significantly in the same patient from day to day, reflecting its clinical course. It depends on the severity of the ARF, the underlying process, the associated co-morbidity, and therapeutic approach. The detection of patients at high risk for malnutrition is extremely important; nutritional markers and indexes of caloric and protein requirements are useful to adapt renal replacement and nutritional support to ARF patients. Various biochemical parameters (namely, serum albumin and prealbumin), anthropometic measures, indirect calorimetry, urea and creatinine kinetics are all useful tools to evaluate metabolic status and requirements nutritional. Commonly, the caloric requirements are nearly 35 kcal/kg/24 h with correction factors applied for certain clinical situations: carbohydrates account for 50 to 60% of those needs whereas lipids account for the rest. The total amount of fluid administered has to be adapted to the possible ultrafiltration achieved by dialysis. Daily dialysis sessions and continuous renal replacement therapy allow larger volumes and thus facilitate nutritional support. Protein needs frequently exceed 1.2 g/kg/24 h to maintain the nitrogen balance, with a calorie to protein ration close to 150 kcal per g of nitrogen. Sufficient amounts of vitamins and oligo-elements are necessary. Stimulating anabolism by exogenous mediators, such as androgenic hormones or growth factors (rh-IGF1, rh-GH) is an avenue that deserves better definition in critically ill ARF patients.

Acute Kidney Injury↗

Protein catabolic rate over lean body mass ratio: a more rational approach to normalize the protein catabolic rate in dialysis patients.

Protein catabolic rate (PCR), equivalent to dietary protein intake in "stable" dialysis patients, is widely accepted as a marker of their protein nutritional status. PCR is usually established from urea generation rate using urea kinetic modeling (UKM), but the normalizing factor is still a matter of controversy. By convention, PCR is expressed in grams of protein degraded daily divided by the dry body weight (BW) (nPCRBW). To be valid, this implies that dry BW is close to ideal BW and that body composition is preserved with a lean body mass (LBM) over BW ratio near 0.73. Such conditions being infrequently found in dialysis patients, it has been proposed to normalize PCR to ideal BW or to total body water, but these correction factors are not really appropriate. A more rational approach would be to express PCR as the ratio of protein degraded to the kilograms of LBM (nPCRLBM), thus offering the main advantage of directly coupling PCR to changes in protein or nitrogen reserve. In this study, we developed a combined kinetic model of urea and creatinine applied to the midweek dialysis cycle in 66 end-stage renal disease (ESRD) patients. UKM provided Kt/V and PCR, whereas creatinine kinetic modeling (CKM) was used to calculate LBM. Thirty-four patients with a preserved LBM (LBM/dry BW ratio equal to or greater than 0.70; mean ratio, 0.81 +/- 0.11) and with a dry/ideal BW ratio of 1.01 +/- 0.16 had a mean PCR of 1.14 +/- 0.30 g/kg/24 h when normalized to BW (nPCRBW) and of 1.40 +/- 0.30 g/kg/24 h when normalized to LBM (nPCRLBM). In the 32 patients with a reduced LBM (LBM/dry BW ratio, below 0.70; mean ratio, 0.60 +/- 0.09) and dry/ideal BW ratio of 1.11 +/- 0.23, the mean nPCRBW was 0.99 +/- 0.31 g/kg/24 h, whereas nPCRLBM was 1.62 +/- 0.32 g/kg/24 h. For both subgroups, Kt/V was similar, with mean values of 1.76 +/- 0.34 and 1.69 +/- 0.27. Normalizing PCR to LBM offers a double benefit: it compensates for the error induced by abnormal body composition (eg, obese patients) and permits PCR to be adjusted for the decrease in LBM that occurs with age. We propose nPCRLBM as a more rational index to express PCR in dialysis patients.

Aged↗

Urea kinetic modeling for CRRT.

Urea kinetic modeling (UKM) for dialysis quantification and prescription, although widely used in chronic renal failure (CRF), has been largely absent in the acute setting. A quantitative approach to prescription of continuous renal replacement therapies (CRRTs) for acute renal failure (ARF) based on UKM is presented. For patients with a relatively constant urea generation rate, G, who are receiving a fixed dose of CRRT, blood urea nitrogen (BUN) falls in an exponential fashion, approaching a plateau level after 3 to 4 days of continuous treatment. The CRRT clearance, K, necessary to achieve a desired plateau value of BUN, Cgoal, may be computed as G/Cgoal x K for all but predilutional CRRT modalities may be calculated as equal to the effluent (dialysate plus ultrafiltrate) flow rate from the filter. Urea mass balance equations are proposed for the determination of patient G value either during the pretreatment rise in BUN or during the decline in BUN with CRRT. In the absence of a reliable estimate of patient G, a reasonable CRRT starting prescription is to set the filter effluent rate in liters per hour (approximately K) to 1.2 times the patient's body weight in kilograms divided by the desired Cgoal in milligrams per deciliter. This relationship assumes moderate hypercatabolism (normalized protein catabolic rate = 2.0 g/kg/d) and patient urea distribution volume equal to 60% of body weight. For Cgoal = 60 mg/dL, this reduces to an easily remembered formula for K (in L/hr) of twice the patient's body weight divided by 100.

Acute Kidney Injury↗

Central venous dialysis catheter dysfunction.

Central venous catheter dysfunction is a limiting factor in regard to renal replacement therapy efficiency and can thus influence patient morbidity. Early catheter dysfunction is frequently due to mechanical problems such as inadequate positioning, kinking, or constriction, but early fibrin deposition can develop soon after insertion. Delayed dysfunction usually results from thrombus formation, either within the lumen, around the catheter ("fibrin sleeve"), or in the host vein. Catheter dysfunction is suspected clinically or documented by simple imaging studies. It is usually evident and manifested by failure to aspirate blood from the lumen(s), inadequate blood flow and/or high resistance pressures during hemodialysis. However, a more subtle dysfunction may lead to a high recirculation of dialyzed blood and be overlooked if dialysis adequacy is not monitored regularly. Local instillation of a fibrinolytic agent is usually successful in restoring catheter patency. Central venous dialysis catheters present intrinsic limitations consequent to their composition and design, whereas extrinsic limitations result from site of insertion, blood properties and anatomic particularities of a given individual. These characteristics largely determine overall catheter performances. Performance parameters to consider include maximal consistently achievable blood flow rate, resistance to blood flow indicated by arterial and venous pressures during hemodialysis, and blood recirculation rate. Catheter longevity is an important consideration for cuffed catheters implanted for long-term use. The tolerated blood recirculation within central venous dialysis catheters should be below 10% to 15%, and is ideally between 3% to 7% in most clinical settings. Several recent studies confirm that short femoral catheters recirculate significantly more than is desirable. Well functioning and nonreversed internal jugular and subclavian venous catheters have, in general, recirculation rates less than 5%. With regard to various performance criteria, the TwinCath (Medcomp, Harleysville, PA) appears particularly advantageous. In any case, a good catheter maintenance program is of critical importance for the prevention and the early detection of catheter dysfunction.

Catheterization, Central Venous↗

Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement.

The "gold standard" method to evaluate the mass balances achieved during dialysis for a given solute remains total dialysate collection (TDC). However, since handling over 100 liter volumes is unfeasible in our current dialysis units, alternative methods have been proposed, including urea kinetic modeling, partial dialysate collection (PDC) and more recently, monitoring of dialysate urea by on-line devices. Concerned by the complexity and costs generated by these devices, we aimed to adapt the simple "gold standard" TDC method to clinical practice by diminishing the total volumes to be handled. We describe a new system based on partial dialysate collection, the continuous spent sampling of dialysate (CSSD), and present its technical validation. Further, and for the first time, we report a long-term assessment of dialysis dosage in a dialysis clinic using both the classical PDC and the new CSSD system in a group of six stable dialysis patients who were followed for a period of three years. For the CSSD technique, spent dialysate was continuously sampled by a reversed automatic infusion pump at a rate of 10 ml/hr. The piston was automatically driven by the dialysis machine: switched on when dialysis started, off when dialysis terminated and held during the by pass periods. At the same time the number of production cycles of dialysate was monitored and the total volume of dialysate was calculated by multiplying the volume of the production chamber by the number of cycles. Urea and creatinine concentrations were measured in the syringe and the masses were obtained by multiplying this concentration by the total volume. CSSD and TDC were simultaneously performed in 20 dialysis sessions. The total mass of urea removed was calculated as 58038 and 60442 mmol/session (CSSD and TDC respectively; 3.1 +/- 1.2% variation; r = 0.99; y = 0.92x -28.9; P < 0.001). The total mass of creatinine removed was 146,941,143 and 150,071,195 mumol/session (2.2 +/- 0.9% variation; r = 0.99; y = 0.99x + 263; P < 0.001). To determine the long-term clinical use of PDC and CSSD, all the dialysis sessions monitored during three consecutive summers with PDC (during 1993 and 1994) and with CSSD (1995) in six stable dialysis patients were included. The clinical study comparing PDC and CSSD showed similar urea removal: 510 +/- 59 during the first year with PDC and 516 +/- 46 mmol/dialysis session during the third year, using CSSD. Protein catabolic rate (PCR) could be calculated from total urea removal and was 1.05 +/- 0.11 and 1.05 +/- 0.09 g/kg/day with PDC and CSSD for the same periods. PCR values were clearly more stable when calculated from the daily dialysate collections than when obtained with urea kinetic modeling performed once monthly. We found that CSSD is a simple and accurate method to monitor mass balances of urea or any other solute of clinical interest. With CSSD, dialysis efficacy can be monitored at every dialysis session without the need for bleeding a patient. As it is external to the dialysis machine, it can be attached to any type of machine with a very low cost. The sample of dialysate is easy to handle, since it is already taken in a syringe that is sent directly to the laboratory. The CSSD system is currently in routine use in our unit and has demonstrated its feasibility, low cost and high clinical interest in monitoring dialysis patients.

Creatinine↗

Erythropoietin and oxidative stress in haemodialysis: beneficial effects of vitamin E supplementation.

Oxidative stress can produce profound alterations to cellular membrane lipids, impairing cell metabolism and viability. This phenomenon, previously observed in haemodialysis patients, has been proposed as a significant factor in regard to haemodialysis-related shortened red blood cells (RBC) survival. In the present study, several parameters associated with oxidative stress were evaluated in a group of haemodialysis patients either receiving erythropoietin therapy (n = 12, mean erythropoietin dose 88 +/- 24 U/kg/week) or not receiving such therapy (n = 30), and in 38 controls. Malonyldialdehyde (MDA, nmol/ml), an end-product of lipid peroxidation, and RBC antioxidant systems were measured, including RBC alpha-tocopherol (RBC vitamin E, mg/l), RBC glutathione (GSH, nmol/mgHb), and RBC superoxide dismutase activity (SOD, U/mgHb). Plasma vitamin E concentrations were also evaluated. Finally, oral vitamin E supplementation (500 mg daily), an exogenous antioxidant, was administered for 6 months to seven patients from the dialysis group receiving erythropoietin while oxidative parameters were repeatedly evaluated and erythropoietin requirements monitored, in order to appreciate the therapeutic relevance of an antioxidant supplementation. An elevation of serum MDA was observed in all haemodialysis patients and a significant decrease in RBC vitamin E, despite normal serum vitamin E levels. Furthermore, the reduction in RBC vitamin E was more important in patients treated with erythropoietin. Vitamin E supplementation resulted in a significant increase in RBC vitamin E (from 0.3 +/- 0.1 to 1.2 +/- 0.2 mg/l of pellet) and a reduction in erythropoietin dose (from 93 +/- 24 to 74 +/- 26 U/kg/week) while maintaining stable haemoglobin concentrations. These results suggest that the oxidative stress could be one of the resistance factors to erythropoietin response in haemodialysis and that vitamin E supplementation could have a sparing effect on erythropoietin dosage requirement.

Adult↗

Urea rebound and delivered Kt/V determination with a continuous urea sensor.

BACKGROUND: The recent introduction of urea sensors for dialysis monitoring has made possible new approaches to urea kinetic modelling. In this study we show how the equilibrated postdialysis urea concentration (Ceq) and Kt/V corrected for double-pool urea kinetics (Kt/Vdp) can be accurately determined using an on-line sensor providing a continuous measure of blood water urea. A modification of the Smye constant volume double-pool theory led to the following equations for Ceq and Kt/Vdp [formula: see text] where Cpre is the blood concentration measured at the start of dialysis, t is the length of the dialysis session (in min) and S(ex) is the constant slope of the blood urea logarithm concentration decline following development of the intercompartmental urea concentration gradient in the first 30-60 min of dialysis. METHODS: These equations were tested in 11 patients undergoing 165-240 min of paired filtration dialysis with continuous monitoring of blood urea concentration. Cpre was determined as the plateau concentration during a preliminary period of 15-20 min of slow isolated ultrafiltration. S(ex) was accurately determined from linear regression applied to the urea sensor data from the 80-min point to the end of dialysis. RESULTS: Ceq and Kt/Vdp determined from the above equations compared closely to values determined from 25-40 min of urea rebound monitoring with the urea sensor: 10.6 +/- 3.0 versus 10.8 +/- 2.7 mmol/l (mean +/- SD) for Ceq and 1.21 +/- 0.24 versus 1.18 +/- 0.20 for Kt/Vdp, compared to single-pool values of Kt/V = 1.34 +/- 0.23. CONCLUSION: This technique may be readily programmed into on-line urea monitors to provide current and extrapolated values of Ceq and Kt/Vdp from about the first hour of dialysis.

Adult↗