Variation of the count-dependent Metz filter with imaging system modulation transfer function.

A systematic investigation was conducted of how a number of parameters which alter the system modulation transfer function (MTF) influence the count-dependent Metz filter. Since restoration filters are most effective at those frequencies where the object power spectrum dominates that of the noise, it was observed that parameters which significantly degrade the MTF at low spatial frequencies strongly influence the formation of the Metz filter. Thus the radionuclide imaged and the depth of the source in a scattering medium had the most influence. This is because they alter the relative amount of scattered radiation being imaged. For low-energy photon emitters, the collimator employed and the distance from the collimator were found to have less of an influence but still to be significant. These cause alterations in the MTF which are more gradual, and hence are most pronounced at mid to high spatial frequencies. As long as adequate spatial sampling is employed, the Metz filter was determined to be independent of the exact size of the sampling bin width, to a first approximation. For planar and single photon emission computed tomographic (SPECT) imaging, it is shown that two-dimensional filtering with the Metz filter optimized for the imaging conditions is able to deconvolve scatter and other causes of spatial resolution loss while diminishing noise, all in a balanced manner.

Filtration↗

Constrained least-squares restoration of nuclear medicine images: selecting the coarseness function.

Image restoration using the constrained least-squares (CLS) method theoretically adapts to the image being processed. In addition, it only requires knowing the modulation transfer function of the imaging system when applied to nuclear medicine images. Prompted by these observations, a systematic evaluation of the effects of the form of the "coarseness function" [C(f)] used by the CLS method has been conducted. Nine C(f)'s are evaluated using an observer preference and a normalized mean-squared error (NMSE) criterion. This evaluation is conducted for three modulation transfer functions and a wide range of count levels. The results of the subjective studies support using the form of C(f) which has been most widely employed in previous studies, i.e., the form designed to minimize the energy in the second derivative of the restored image. A different form of C(f) is generally found to be optimal by the mean-squared error criterion. The CLS method is then compared to: (1) no processing, (2) count-dependent smoothing, and (3) count-dependent Metz restoration. When evaluated using objective measurements of error and contrast, the CLS method is found to be slightly inferior to the best method, Metz restoration. However, CLS restoration is found to be equal to or better than the other methods when judged by the results of observer preference studies.

Image Processing, Computer-Assisted↗

Modifying constrained least-squares restoration for application to single photon emission computed tomography projection images.

Image restoration methods have been shown to increase the contrast of nuclear medicine images by decreasing the effects of scatter and septal penetration. Image restoration can also reduce the high-frequency noise in the image. This study applies constrained least-squares (CLS) restoration to the projection images of single photon emission computed tomography (SPECT). In a previous study, it was noted that CLS restoration has the potential advantage of automatically adapting to the blurred object. This potential is confirmed using planar images. CLS restoration is then modified to improve its performance when applied to SPECT projection image sets. The modification was necessary because the Poisson noise in low count SPECT images causes considerable variation in the CLS filter. On phantom studies, count-dependent Metz restoration was slightly better than the modified CLS restoration method, according to measures of contrast and noise. However, CLS restoration was generally judged as yielding the best results when applied to clinical studies, apparently because of its ability to adapt to the image being restored.

Computer Simulation↗

Activity quantitation in SPECT: a study of prereconstruction Metz filtering and use of the scatter degradation factor.

A study of activity quantitation with prereconstruction Metz filtering and use of the scatter degradation factor (SDF) to numerically correct for scatter was conducted. The ratio of the count rate per unit activity for source locations within a 30 x 23-cm water-filled tub phantom to the count rate per unit activity for Tc-99m point sources of known activity imaged in air was used to judge the accuracy of activity determination. The investigation was conducted for certain locations within the tub when it was uniformly filled with Tc-99m activity, and for the same locations at the center of 5, 4, 3, and 2-cm diam, hot spheres imaged in a cold background. The source locations were the center, and one-fourth, one-half, and three-fourths the major axis. Various methods of combining the conjugate views for use with prereconstruction attenuation correction (arithmetic and geometric mean), and extent to which the Metz filter followed the inverse filter before rolling off to suppress noise were investigated. Without Metz filtering, attenuation correction was performed using a transmission curve that included buildup. With Metz filtering, the good-geometry attenuation coefficient was used and the combined views were scaled by the SDF calculated for the average body thickness. Depending on the size of the sphere and the extent to which the inverse filter was followed, Metz filtering combined with use of the SDF improved the accuracy of activity quantitation.

Filtration↗

The effect of intrinsic attenuation correction methods on the stationarity of the 3-D modulation transfer function of SPECT.

The application of stationary restoration techniques to SPECT images assumes that the modulation transfer function (MTF) of the imaging system is shift invariant. It was hypothesized that using intrinsic attenuation correction (i.e., methods which explicitly invert the exponential radon transform) would yield a three-dimensional (3-D) MTF which varies less with position within the transverse slices than the combined conjugate view two-dimensional (2-D) MTF varies with depth. Thus the assumption of shift invariance would become less of an approximation for 3-D post- than for 2-D pre-reconstruction restoration filtering. SPECT acquisitions were obtained from point sources located at various positions in three differently shaped, water-filled phantoms. The data were reconstructed with intrinsic attenuation correction, and 3-D MTFs were calculated. Four different intrinsic attenuation correction methods were compared: (1) exponentially weighted backprojection, (2) a modified exponentially weighted backprojection as described by Tanaka et al. [Phys. Med. Biol. 29, 1489-1500 (1984)], (3) a Fourier domain technique as described by Bellini et al. [IEEE Trans. ASSP 27, 213-218 (1979)], and (4) the circular harmonic transform (CHT) method as described by Hawkins et al. [IEEE Trans. Med. Imag. 7, 135-148 (1988)]. The dependence of the 3-D MTF obtained with these methods, on point source location within an attenuator, and on shape of the attenuator, was studied. These 3-D MTFs were compared to: (1) those MTFs obtained with no attenuation correction, and (2) the depth dependence of the arithmetic mean combined conjugate view 2-D MTFs.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗