DNA commission of the International Society of Forensic Genetics: recommendations on forensic analysis using Y-chromosome STRs.

During the past few years the DNA commission of the International Society of Forensic Genetics has published a series of documents providing guidelines and recommendations concerning the application of DNA polymorphisms to the problems of human identification. This latest report addresses a relatively new area, namely Y-chromosome polymorphisms, with particular emphasis on short tandem repeats (STRs). This report addresses nomenclature, use of allelic ladders, population genetics and reporting methods.

Alleles↗

Population variation at the CODIS core short tandem repeat loci in Europeans.

Substantial STR population data exist to estimate F(ST) (or theta) values across Europeans. Eleven populations across Europe were analyzed, and the estimate over all 13 CODIS core STR loci is 0.0028. This value is much less than the conservative estimate of 0.01 advocated by the second National Research Council Report in 1996. Because of the low value for theta, whether independence is assumed or an adjustment for substructure is employed, there is little practical consequence for forensic purposes for estimating the frequency of a multiple locus DNA profile. If theta is used, a value of 0.01 is very conservative for Europeans. The same STR population data can be used for evolutionary studies on Europeans, and the calculated genetic distances are consistent with the ethnohistory of the populations.

Journal Article↗

Using a CCD camera imaging system as a recording device to quantify human DNA by slot blot hybridization.

Slot blot hybridization of membrane-immobilized, single-stranded human DNA with the higher primate-specific alphoid probe D17Z1 is routinely used in forensic science to estimate the amount of DNA in biological samples. Typically, a chemiluminescent signal captured on film records the hybridization, and the quantity of the signal is related to the amount of immobilized DNA. Digital imaging using a cooled CCD camera offers an alternate non-film-based method for image acquisition with comparable sensitivity of detection, a greater dynamic range, enhanced capability of data interpretation, and often faster results than film. In addition, the data support the premise that more accurate and precise human DNA quantification should be obtained by not assuming a linear response of signal to known standards. Instead, quantity should be estimated using a second-order standard curve (R2 = 0.999). Finally, a CCD camera imaging system offers versatility for image capture of different signal sources and analysis of samples on a variety of support media.

DNA↗

CODIS STR loci data from 41 sample populations.

Allele distributions for 12 or 13 CODIS core tetrameric short tandem repeat (STR) loci CSFIPO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, and vWA were determined in 41 population data sets. The major population groups comprise African Americans, U.S. Caucasians, Hispanics, Far East Asians, and Native Americans. There was little evidence for departures from Hardy-Weinberg expectations (HWE) in any of the populations. The FST estimates over all thirteen STR loci are 0.0006 for African Americans, -0.0005 for Caucasians, 0.0021 for Hispanics, 0.0039 for Asians, and 0.0282 for Native Americans.

Ethnicity↗

Concordance study on population database samples using the PowerPlex 16 kit and AmpFlSTR Profiler Plus kit and AmpFlSTR COfiler kit.

Over 500 population database samples comprising African Americans, Bahamians, and Southwestern Hispanics were typed using the PowerPlex 16 and the Profiler Plus COfiler kits. There was only one sample in which a typing difference was observed. An FGA heterozygote profile was observed using the PowerPlex 16 primers, and a single allele FGA profile was observed using Profiler Plus primers. Thus, the extant data suggest that the primers used in the PowerPlex 16, Profiler Plus, and COfiler kits are reliable for typing reference samples destined for use in CODIS. In addition, African American, Bahamian, and Southwestern Hispanic databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic. The application of the product rule is valid for estimating the rarity of a multiple loci profile consisting of these two and the 13 core STR loci.

DNA Fingerprinting↗

Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples.

The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.

DNA Fingerprinting↗

Validation of STR typing by capillary electrophoresis.

With the use of capillary electrophoresis (CE), high-resolution electrophoretic separation of short tandem repeat (STR) loci can be achieved in a semiautomated fashion. Laser-induced detection of fluorescently labeled PCR products and multicolor analysis enable the rapid generation of multilocus DNA profiles. In this study, conditions for typing PCR-amplified STR loci by capillary electrophoresis were investigated using the ABI Prism 310 Genetic Analyzer (Applied Biosystems). An internal size standard was used with each run to effectively normalize mobility differences among injections. Alleles were designated by comparison to allelic ladders that were run with each sample set. Multiple runs of allelic ladders and of amplified samples demonstrate that allele sizes were reproducible, with standard deviations typically less than 0.12 bases for fragments up to 317 bases in length (largest allele analyzed) separated in a 47 cm capillary. Therefore, 99.7% of all alleles that are the same length should fall within the measurement error window of +/- 0.36 bases. Microvariants of the tetranucleotide repeats were also accurately typed by the analytical software. Alleles differing in size by one base could be resolved in two-donor DNA mixtures in which the minor component comprised > or = 5% of the total DNA. Furthermore, the quantitative data format (i.e., peak amplitude) can in some instances assist in determining individual STR profiles in mixed samples. DNA samples from previously typed cases (typed for RFLP, AmpliType PM+DQA1, and/or D1S80) were amplified using AmpFlSTR Profiler Plus and COfiler and were evaluated using the ABI Prism 310. Most samples yielded typable results. Compared with previously determined results for other loci, there were no discrepancies as to the inclusion or exclusion of suspects or victims. CE thus provides efficient separation, resolution, sensitivity and precision, and the analytical software provides reliable genotyping of STR loci. The analytical conditions described are suitable for typing samples such as reference and evidentiary samples from forensic casework.

DNA Fingerprinting↗

Identification of missing persons: the Spanish "Phoenix" program.

In 1999, Spain was the first country to officially start a National Program to try to identify cadavers and human remains which could not be identified by the use of traditional forensic approaches. This attempt is called "Phoenix Program". Two independent mitochondrial DNA (mtDNA) databases were generated, which can automatically compare and match identical or similar sequences. One is the Reference Database, with mtDNA sequences from maternal relatives of missing persons, who provide the samples (buccal swabs) voluntarily; the other is the Questioned Database, comprised of mtDNA data of unknown remains and cadavers. Although the first phase of the program (typing of all unidentified human remains) will probably not be completed until December 2003, positive identifications are being made in the interim. To date, more than 1,200 families have contacted Phoenix, and at least 280 reference samples and 48 questioned evidences have been analyzed. When mtDNA matches are found, another independent analysis is performed as a part of the quality control mechanism. Once a match is confirmed (so far in 6 cases), an attempt is made to analyze short tandem repeat (STR) loci. We call for international collaboration to make this effort valuable worldwide.

Cadaver↗

A compendium of human mitochondrial DNA control region: development of an international standard forensic database.

A compendium of human mitochondrial DNA (mtDNA) control region types has been constructed. This updated compilation indexes over 10,000 population-specific mtDNA nucleotide sequences in a standardized format. The sequences represent mtDNA types from the Scientific Working Group on DNA Analysis Methods (SWGDAM) mtDNA database and from the public literature. The SWGDAM data are considered to be of higher quality than the public data, particularly for counting the number of times a particular haplotype has been observed.

Base Sequence↗

Length variation in HV2 of the human mitochondrial DNA control region.

Hair samples were typed from three individuals who exhibited length heteroplasmy in the homopolymeric cytosine stretches (C-stretch) in hypervariable region 2 (HV2). The study demonstrated that for different hairs within an individual, the HV2 C-stretch region can vary with respect to the number of cytosines and/or proportion of C-stretch length variants. Length heteroplasmy may occur regardless of the prominent length variant present in this region. Differences in the number of cytosines at the C-stretch region, or a variation in the relative amounts of heteroplasmic length variants, cannot be used to support an interpretation of exclusion.

Amino Acid Sequence↗

Practical applications of genotypic surveys for forensic STR testing.

Legitimate genotype frequency estimation for multiallelic loci relies on component allele frequencies, as population surveys represent only a fraction of possible DNA profiles. Multilocus genotypes from two ethnic human populations, African American (n=195) and U.S. Caucasian (n=200), were compiled at 13 STR loci that are used worldwide in forensic investigation (D3S1358, vWA, FGA, D16S539, TH01, TPOX, CSF1PO, D8S1179, D21S11, D18S51, D5S818, D13S317, and D7S820). Sex-specific AmpFlSTR multiplexes provided stringent PCR-based STR typing specifically optimized for multicolor fluorescence detection. Heterozygosity at each STR locus ranged from 0.57 to 0.89 and encompassed from seven (TH01) to twenty-one (D21S11) alleles. Homozygosity tests, tests based on the distinct numbers of observed homozygous and heterozygous classes, log likelihood ratio tests, and exact tests assessed that the degree of divergence from theoretical Hardy-Weinberg proportions for all 13 STRs does not have practical consequence in genotype frequency estimation. Departures from linkage equilibrium, between loci, that imposed significance to forensic calculations were not indicated by observed variance of the number of heterozygous loci or Karlin interclass correlation tests. For forensic casework, reliable multilocus profile estimates may be obtained from the product of component genotype frequencies, each calculated through application of the Hardy-Weinberg equation to population database allele frequency estimates reported here. The average probability that two randomly selected, unrelated individuals possess an identical thirteen-locus DNA profile was one in 1.8x10(15) African Americans and one in 3.8x10(14) U.S. Caucasians.

Black or African American↗