Search PubMed⌕ Search

Biomedical subjects

B Brunelli

Publications and source records attributed to B Brunelli.

At least 19 recordsLinked to original sources

A novel mimetic antigen eliciting protective antibody to Neisseria meningitidis.

Molecular mimetic Ags are of considerable interest as vaccine candidates. Yet there are few examples of mimetic Ags that elicit protective Ab against a pathogen, and the functional activity of anti-mimetic Abs has not been studied in detail. As part of the Neisseria meningitidis serogroup B genome sequencing project, a large number of novel proteins were identified. Herein, we provide evidence that genome-derived Ag 33 (GNA33), a lipoprotein with homology to Escherichia coli murein transglycosylase, elicits protective Ab to meningococci as a result of mimicking an epitope on loop 4 of porin A (PorA) in strains with serosubtype P1.2. Epitope mapping of a bactericidal anti-GNA33 mAb using overlapping peptides shows that the mAb recognizes peptides from GNA33 and PorA that share a QTP sequence that is necessary but not sufficient for binding. By flow cytometry, mouse antisera prepared against rGNA33 and the anti-GNA33 mAb bind as well as an anti-PorA P1.2 mAb to the surface of eight of nine N. meningitidis serogroup B strains tested with the P1.2 serosubtype. Anti-GNA33 Abs also are bactericidal for most P1.2 strains and, for susceptible strains, the activity of an anti-GNA33 mAb is similar to that of an anticapsular mAb but less active than an anti-P1.2 mAb. Anti-GNA Abs also confer passive protection against bacteremia in infant rats challenged with P1.2 strains. Thus, GNA33 represents one of the most effective immunogenic mimetics yet described. These results demonstrate that molecular mimetics have potential as meningococcal vaccine candidates.

Adult↗

[The Monte Carlo method and parallel estimation in the drawing up of radiosurgery treatment plans].

PURPOSE: We investigated the practical application of a calculation algorithm based on the Monte Carlo method to stereotactic radiosurgery treatment planning. In radiosurgery, high dose gradients and the lack of electronic disequilibrium make high resolution matrices and high computing power and speed necessary to obtain accurate dose distribution. To date, the main obstacle to the wider-spread use of the Monte Carlo method has been the huge computing time necessary to obtain a dose distribution on current hardware. MATERIAL AND METHODS: In this project, developed within the ESPRIT program, funded by the European Union, a Parsytec CC (Cognitive Computing) computer was used with 9 processors (Power PC 604, 133 Mhz, RAM 64 Mb) with IBM AIX/EPX OS and availability for Fortran parallel codes compilation, connected to a PC for data input, results rendering, and dose distribution calculation with a conventional algorithm for comparison with the Monte Carlo code (an EGS4 user code). The module named Rapt Region Extractor performs data compression with an octree method without decreasing resolution, for RAM and computing time requirements to remain acceptable. A model of the 6 MV photon beam from Clinac 2100C Varian linear accelerator was devised, based on incident photon energy spectrum and, for each collimator dimension, on bidimensional dose distribution orthogonal to beam direction measured at SSd = SAD = 100 cm. RESULTS: Parallelization was carried out on event numbers, allowing a simulation speed to number of processor ratio close to unity. A new random number generator was used, capable of correctly running on the parallel architecture. The simulation procedure includes: 1) CT acquisition in DICOM 3.0 format, Analyze or with scanner; 2) Target delineation, treatment arc definition. 3) Dose calculation, with both conventional and Monte Carlo methods. 4) Dose distribution rendering on every transverse, sagittal or coronal planes overlapped in color wash on anatomical representation. Comparison between conventional and Monte Carlo algorithms were carried out on an anthropomorphic phantom and 10 real patients, with 2.5 mm anatomical resolution and standard deviation never exceeding 2%. A simulation with 10,000,000 events and 1% maximum variance can be run in 43'. When PTV is an homogeneous areas the differences between the two methods are around 5%, while when PTV is localized in dishomogeneous areas discrepancies reach 20% in the bone. CONCLUSIONS: In conclusion, the feasibility of direct simulation with the Monte Carlo method in radiosurgery has been demonstrated within time and hardware costs compatible with clinical practice.

Algorithms↗

[Results and considerations regarding auditory neonatal screening based on the use of transient evoked otoacoustic emission].

The authors present a 5-year clinical experience in audiological screening performed at the neonatal center of the Policlinico of Perugia, Italy. The study was performed using an IL088 Otodynamics unit produced by Bray & Kemp. A total of 1328 newborns (2656 ears) were tested on the 4th day of life and during spontaneous sleep. None of the children had any audiological risk factors. The test was repeated one month later for all subjects who lacked Transient Evoked Otoacoustic Emissions and in many cases ABR testing was performed by 3 months of age. The authors present the undoubted advantages of the present method which include the fact that it is a) easy to perform, b) non invasive, c) sensitive and d) effective. They then discuss the main problems which arose during the course of the screening and advance some solutions. For the most part these problems involved the high number of false positives (13.1%) and the high percentage of subjects who were lost to subsequent controls (approximately 6% of the total population). The number of false positives could be reduced by using a linear acoustic stimulation (rather than the non-linear stimulation which is the default parameter for the machine). Such a linear stimulation can improve the signal-to-noise ratio, thus making it possible to adopt a reproducibility index lower than the 70% presently used (however, this brings with it the risk of including a certain number of false negatives). Finally, they discuss the possibility of only retesting those subjects with bilateral lack of TEOAEs, thus reducing the number of check-ups to be performed a month later.

Acoustic Stimulation↗

[Products of acoustic distortion in the examination of deafness in an infant].

Distortion-product otoacoustic emissions (DPOAEs) are otoacoustic emissions evoked by two pure tones. The greatest advantage of DPOAEs is their frequency specificity with respect to the eliciting bitonal stimuli. The purpose of this study was to compare DPOAEs in two populations. This paper reports input/output DPOAEs functions and DPOAE-audiograms for audiometric frequencies of f2 between 696 and 6006 Hz in a normal neonate population and in an adult control group. Fifteen healthy fullterm newborns (29 ears) and 8 normal-hearing adults (16 ears) participated as subjects. Results at medium frequencies indicate that the maximum amplitudes of the DPOAEs were generated by neonates, the detection threshold was better and the dynamic range was greater than in adults, making them potentially valid for studying cochlear functioning in infants.

Adult↗

[Preliminary evaluation of the clinical use of a system for intraoperative radiotherapy with electrons (IORT)].

The preliminary evaluation of the dosimetric characteristics of a dedicated intraoperative electron beam therapy system is described (Bionix Corporation). The linear accelerator is the Varian 2100 C with electron beam energies of 6, 9, 12, 16 e 20 MeV. The isodose distribution for each of 15 available applicators (5 plane and 10 beveled) has been studied with a water phantom. The problems of the homogeneity of dose distribution, scattered and leakage radiation outside the applicators and X-ray contamination of the electron beams have been addressed, at the nominal 20 MeV energy for exemplification. The accurate knowledge of such physical and dosimetric properties are necessary for the implementation of the IORT techniques in terms of choice of the applicator size and electron beam energy for tumor coverage and dose sparing of critical organs.

Combined Modality Therapy↗

[Physico-technical aspects of total skin irradiation with high-intensity-dose electrons].

The authors have addressed the physical and technical problems involved in the total skin irradiation with a linear accelerator Varian Clinac 2100 C expressly preset for this modality with electrons of 6 MeV nominal energy and dose rate of about 2500 UM/min at the isocenter. The six dual field technique has been implemented and the effect of interposed degrading filters has been evaluated with film dosimetry on an anthropomorphic phantom. It was verified that the total skin electron irradiation expressly offered by the manufacturer as an established treatment option on the Clinac 2100 C with high performance ionizing chambers and high dose rate makes the all procedure safer and simpler.

Electrons↗

[Verification of 3 computerized systems for drafting a plan for treatment with electrons].

The electron beam treatment planning systems, with the availability of more and more developed hardware for complex calculation algorithms, need quality controls of accuracy and comparability of treatment plans from different systems. In this paper three systems have been evaluated; their similar computation algorithms (pencil beam) have been used but in some conditions (beam reconstruction, oblique incidence and dishomogeneity) different results have been drawn. The basic data (PDD, dose profile, etc.) were the same for every system, therefore it has been observed that different results are mainly due to differences in: a) input of parameter values, b) calculation algorithm approximations, c) image acquisitions and elaboration.

Electrons↗