Search PubMed⌕ Search

Biomedical subjects

B Boné

Publications and source records attributed to B Boné.

At least 19 recordsLinked to original sources

Adjunctive diagnostic value of targeted electrical impedance imaging to conventional methods in the evaluation of breast lesions.

PURPOSE: To determine the diagnostic accuracy of targeted electrical impedance imaging in characterizing breast lesions, and to evaluate whether lesion size, depth and histopathology affect the diagnosis. MATERIAL AND METHODS: A total of 137 women with 145 lesions (79 malignant and 66 benign) found by palpation or mammography were prospectively enrolled in this study. The patients were examined by means of clinical breast examination, mammography, ultrasonography, and electrical impedance imaging with TransScan TS2000. A level of suspicion (LOS) post-processing algorithm (v2.67) was used for TS2000 lesion assessment. Imaging findings were correlated with cytologic (n=54) and histologic diagnoses (n=91). Patients with benign lesions were followed up for a mean of 36 months. RESULTS: TS2000 showed a high sensitivity (86%) which did not differ significantly from that of mammography (87%) and ultrasonography (US) (75%). The specificity of TS2000 (49%) was significantly lower compared to mammography (97%, P<0.0001) and US (100%, P<0.0001). The additive use of TS2000 to mammography and US yielded no significant increase in sensitivity (97%), but the decrease in specificity was significant (46%, P<0.0001). Diagnostic effectiveness of TS2000 (Az=0.68), as measured by the area under the ROC curve, was significantly lower than for mammography (Az=0.93, P<0.0001) and for US (Az=0.91, P<0.0001). When using TS2000 in addition to mammography and US (Az=0.86), a significant impairment was found (P=0.0003). CONCLUSION: The role of targeted electrical impedance imaging as an adjunct to mammography and ultrasonography in the diagnosis of breast lesions is not justified by the result of this study.

Adult↗

Complementary use of scintimammography with 99m-Tc-MIBI to triple diagnostic procedure in palpable and non-palpable breast lesions.

PURPOSE: The aim of this study was to determine the clinical value of scintimammography with 99m-Tc-MIBI (Sc) as a complementary method to the triple diagnostic procedure in the diagnosis of breast lesions. MATERIAL AND METHODS: Ninety-six consecutive patients with 65 palpable and 54 non-palpable breast lesions were included in a prospective study. All lesions were evaluated by clinical examination, mammography and fine-needle-aspiration cytology (FNAC), called triple diagnostic procedure (TD). Prone planar scintimammography with 99m-Tc-MIBI was performed in all patients. Five groups were defined for diagnosis: 1 = normal; 2 = benign; 3 = probably benign; 4 = highly suspect of malignancy; and 5 = malignant. In the calculations, groups 1-3 were considered benign, and 4-5 malignant. All lesions were excised and examined histologically. The additional value of Sc + TD procedure was studied separately for palpable and non-palpable lesions. RESULTS: Histologically, 83 malignant and 36 benign lesions were found in the 119 breast lesions. Sensitivity for malignancy in palpable lesions of TD alone and of the combination TD + Sc were 95.6% and 100%, respectively. Sensitivity for malignancy in non-palpable lesions of TD and TD + Sc was 89.1% and 97.2%, respectively. CONCLUSION: Adding scintimammography to the triple diagnostic procedure increased the sensitivity for the detection of both palpable and non-palpable breast cancers, but decreased the specificity.

Biopsy, Needle↗

Can contrast-enhanced MR imaging predict survival in breast cancer?

PURPOSE: To investigate the value of pre-operative contrast-enhanced MR imaging (CE-MRI) in predicting the disease-free and overall survival in breast cancer. MATERIAL AND METHODS: The study population consisted of 50 consecutive patients with histopathologically verified primary breast cancer who pre-operatively underwent CE-MRI examination between 1992 and 1993. A three-time point MR examination was performed where the enhancement rates (C1 and C2), signal enhancement ratio (SER=C1/C2) and washout (W=C1-C2) were calculated. The relation of these MR parameters to disease-free and overall survival was investigated. The median follow-up for surviving patients was 95 months. Univariate and multivariate statistical analyses were performed to evaluate the impact of different factors on prediction of survival. RESULTS: Of the MR parameters examined at univariate analysis, increased C1 (p=0.029), W (p=0.0081) and SER values (p=0.0081) were significantly associated with shorter disease-free survival, and only C1 (p=0.016) was related significantly to overall survival. Multivariate analysis for disease-free survival showed that the SER (p=0.014) and tumor size (p=0.001) were significant and independent predictors. Age (p=0.003), lymph node status (p=0.014), tumor size (p=0.039) and proliferating cell nuclear antigen index (p=0.053) remained independently associated with overall survival at multivariate analysis. C1 was not confirmed as an independent predictor of overall survival. CONCLUSION: Our findings support the presumption that CE-MRI is useful in predicting the disease-free survival in patients with breast cancer.

Breast Neoplasms↗

Dynamic MR imaging of the breast. Analysis of kinetic and morphologic diagnostic criteria.

PURPOSE: To assess the value of kinetic and architectural diagnostic criteria on dynamic MR breast imaging, and to construct a scoring system for lesion characterization. MATERIAL AND METHODS: A total of 92 women with 109 histopathologically verified breast lesions were included in this retrospective study. The patients were examined by a 1.5 T system using a dedicated double breast coil. A dynamic examination with one precontrast and seven postcontrast series was performed, using a T1-weighted 3D FLASH sequence. Thirty lesions (15 malignant and 15 benign) were randomly chosen for the validation set, and the remaining 79 lesions (62 malignant and 17 benign) formed the estimation set, in which multivariate analysis was performed in order to select the most important features. These parameters were then used for constructing the scoring system, which was tested on the validation set. The scoring system was compared with the routine standard evaluation that used all established diagnostic criteria. ROC curves were generated to assess the diagnostic accuracy of different approaches. RESULTS: In the multivariate analysis of the 79 lesions, time-to-peak enhancement and the descriptor of margins were found to be the most important independent factors for distinguishing benign from malignant lesions, and formed the basis of the scoring system. The areas under the ROC curves for the standard evaluation, and the scoring system were 0.813 and 0.880 in the 30 lesions. CONCLUSION: Time-to-peak enhancement and the descriptor of margins appear to be the most important diagnostic criteria for mass lesions in dynamic breast MR imaging.

Breast↗

Comparison of 99mTc-sestamibi scintimammography and dynamic MR imaging as adjuncts to mammography in the diagnosis of breast cancer.

PURPOSE: To compare the diagnostic accuracy of planar 99mTc-sestamibi scintimammography with dynamic contrast-enhanced MRI (CE-MRI) on the basis of histopathologic results, and to determine the clinical value of these methods as adjuncts to mammography. MATERIAL AND METHODS: A total of 90 consecutive women with 111 histopathologically verified breast lesions were enrolled in the study. Patients underwent scintimammography and CE-MRI in addition to mammography. Each finding was classified on a BI-RADS-like five-point rating scale describing the degree of suspicion for malignancy, and all findings were correlated with the histopathological results. RESULTS: The overall sensitivity/specificity/accuracy was 85%/59%/78% for mammography, 94%/47%/80% for CE-MRI, and 82%/75%/80% for scintimammography, respectively. CE-MRI showed higher sensitivity (p = 0.008), but its specificity was lower than scintimammography (p = 0.049). Using ROC analysis, significant improvement ( p = 0.034) was found between mammography and the combination of mammography + CE-MRI, while mammography + scintigraphy showed no higher diagnostic accuracy than mammography alone. CONCLUSION: If high sensitivity and spatial resolution are needed, CE-MRI is to be preferred in clinical practice as an adjunct to mammography, rather than scintigraphy.

Adult↗

Comparison of lesion size estimated by dynamic MR imaging, mammography and histopathology in breast neoplasms.

To evaluate the accordance of size measurements of malignant breast lesions 65 women with 76 malignant lesions were preoperatively examined with triple diagnosis (mammography was performed in three views with additional views if necessary) and dynamic MR imaging using a subtraction technique with a 3D T1-weighted sequence. Maximum lesion size at histopathology was used as gold standard and compared with maximum lesion size at MRI and mammography. All measurements were made independently for each method. Histopathology verified 48 invasive, 5 in situ, and 23 mixed lesions. No significant difference was found for the pure invasive lesions ( p=0.366). In the mixed lesions a slightly better result for MRI was indicated ( p=0.116), although there was a great spread. Only five pure in situ lesions were assessed, too few to draw any statistical conclusions ( p>0.5). An overall difference indicated a slight superiority of MRI ( p=0.097). The MR imaging and mammography are both good at measuring the size of detected invasive breast malignancies. The total sizes of mixed lesions are frequently underestimated by both MRI and mammography, although the invasive parts were equally well described and measured with both methods.

Breast↗

Value of MR imaging in clinical evaluation of breast lesions.

PURPOSE: To evaluate the value of dynamic MR imaging as an adjunctive tool to triple diagnosis (TD) (physical examination, mammography and fine needle aspiration cytology) in diagnosing breast lesions. MATERIAL AND METHODS: Ninety-three consecutive patients with 114 palpable or mammographically detected breast lesions were examined with TD and MR imaging. The MR examination was performed dynamically using a dedicated breast coil. Five diagnostic groups were defined on a scale from 1=normal, to 5 = malignant, where groups 1-3 were defined as benign and groups 4-5 as malignant. All lesions were histopathologically examined. The sensitivity and specificity were calculated for mammography alone, TD, MR and the combination of MR and TD. RESULTS: Histopathology revealed 32 benign and 82 malignant lesions (73 invasive and 9 cancer in situ). The sensitivity/specificity was 84%/59% for mammography, 93%/41% for TD, 94%/47% for MR and 99%/19% for TD + MR. In the 32 mammographically dense breasts, mammography/TD/MR/TD + MR had a sensitivity of 72%/94%/94%/100% and a specificity of 79%/57%/36%/29%, respectively. CONCLUSION: MR imaging might be of value as an additive method to TD by increasing the sensitivity, but at the cost of decreasing specificity. Patients with mammographically dense parenchyma might have more benefit of the additive value, as the decrease in specificity in these patients was less pronounced in our study.

Adult↗

International investigation of breast MRI: results of a multicentre study (11 sites) concerning diagnostic parameters for contrast-enhanced MRI based on 519 histopathologically correlated lesions.

A multicentre study was undertaken to provide fundamentals for improved standardization and optimized interpretation guidelines of dynamic contrast-enhanced MRI. Only patients scheduled for biopsy of a clinical or imaging abnormality were included. They underwent standardized dynamic MRI on Siemens 1.0 (163 valid lesions > or = 5 mm) or 1.5 T (395 valid lesions > or = 5 mm) using 3D fast low-angle shot (FLASH; 87 s) before and five times after standardized bolus of 0.2 mmol Gd-DTPA/kg. One-Tesla and 1.5 T data were analysed separately using a discriminant analysis. Only histologically correlated lesions entered the statistical evaluation. Histopathology and imaging were correlated in retrospect and in open. The best results were achieved by combining up to five wash-in or wash-out parameters. Different weighting of false-negative vs false-positive calls allowed formulation of a statistically based interpretation scheme yielding optimized rules for the highest possible sensitivity (specificity 30%), for moderate (50%) or high (64-71%) specificity. The sensitivities obtained at the above specificity levels were better at 1.0 T (98, 97, or 96%) than at 1.5 T (96, 93, 86%). Using a widely available standardized MR technique definition of statistically founded interpretation rules is possible. Choice of an optimum interpretation rule may vary with the clinical question. Prospective testing remains necessary. Differences of 1.0 and 1.5 T are not statistically significant but may be due to pulse sequences.

Adult↗

Circulation in the breast after radiotherapy and breast conservation.

OBJECTIVE: To investigate the breast circulation after radiotherapy and breast conservation. DESIGN: Open clinical study. SETTING: University hospital, Sweden. SUBJECTS: 24 patients with breast cancer (mean age 54 years, range 41-64). INTERVENTIONS: The glandular and the subcutaneous circulation in the breast were measured by Xenon (133Xe) clearance and the skin circulation by laser Doppler fluxmetry (LDF) two to five years after radiotherapy (50 Gy) following lumpectomy. The subcutaneous circulation was measured 2 cm above and medial or lateral to the areolar border and the glandular circulation 2 cm below and medial or lateral to the areolar border in the quadrant not previously operated on for carcinoma. The skin circulation was measured at the corresponding sites. MAIN OUTCOME MEASURES: Circulation in the subcutaneous and glandular tissue measured by 133Xe clearance and in the skin by LDF. RESULTS: The subcutaneous circulation, expressed as the ratio of 133Xe clearance in the operated irradiated: non-operated non-irradiated breast, was 0.88 (0.94) (median, interquartile range) and the glandular circulation 0.93 (0.75). The skin circulation ratios over the corresponding areas were 1.00 (0.37) and 1.00 (0.38), respectively. CONCLUSION: Radiotherapy after breast conservation surgery does not lead to long-term changes in basal glandular, subcutaneous, or skin circulation in the breast.

Adult↗

The potential influence of fine-needle aspiration on MR imaging of the breast.

PURPOSE: The aim of this study was to determine whether fine-needle aspiration biopsy (FNAB) of breast lesions causes structural changes or changes in contrast enhancement, that could impair the evaluation of these lesions at MR investigation of the breast. MATERIAL AND METHODS: Fifteen patients with 17 lesions were examined with MR imaging of the breast both before and after the FNAB with a mean interval of 7.1 days. At both examinations, signal intensities were measured pre- and post-contrast enhancement in the lesions as well as in surrounding breast parenchyma and muscle. Imaging with contrast enhancement was performed semidynamically with two images obtained in rapid sequence (acquisition time 6.23 min) immediately after bolus injection of gadopentetate dimeglumine, 0.1 mmol/kg b.w., and the contrast enhancement in both images was calculated. RESULTS: The diagnostic value of MR images was unimpaired by FNAB, and no statistical difference between contrast enhancement in corresponding images obtained before and after FNAB was found, either within the lesions or in the breast parenchyma or muscle. CONCLUSION: FNAB of the breast can be performed without impairing the diagnostic outcome of MR investigation.

Adult↗

The role of scintimammography with 99mTc-sestamibi as a complementary diagnostic technique in the detection of breast cancer.

PURPOSE: To prospectively determine the clinical value of scintimammography (Sc) with 99mTc-sestamibi as a complementary method to triple diagnosis (TD) in detecting malignant disease of the breast. MATERIAL AND METHODS: Ninety-six patients with 119 clinically or mammographically detected breast lesions underwent TD procedures, including clinical examination, mammography and fine-needle aspiration cytology. Prone planar Sc with 99mTc-sestamibi was performed in all 96 patients. Five groups were defined for diagnosis: 1=normal; 2=benign; 3=probably benign; 4=highly suspect of malignancy; and 5=malignant. All lesions were histopathologically examined. The results of each method per se and the combination of TD with Sc (TD+Sc) were analyzed. RESULTS: Histopathology of the 119 surgically excised breast lesions found 83 malignant and 36 benign lesions. TD missed 6 of 83 carcinomas, resulting in a sensitivity of 92.7%. Sc alone showed sensitivity of 85.5%. The combination TD+Sc missed 1 of 83 carcinomas, and thus had a sensitivity of 98.7%. In mammographically dense breasts both TD and Sc detected 16 of 18 carcinomas, while the combination TD+Sc led to detection of all 18 carcinomas. CONCLUSION: Adding Sc to TD increases the sensitivity for detection of breast carcinomas. Sc with 99mTc-sestamibi is recommended as a complimentary method to TD in selected cases such as mammographically dense breasts.

Adenocarcinoma↗

Imaging breasts with silicone implants.

Over the last two decades, the use of breast implants both for breast augmentation and for breast reconstruction following mastectomy has increased substantially. It is estimated that around two million women have undergone breast augmentation, while hundreds of thousands have had breast reconstruction surgery. Different types of material have been used for breast implants, but silicone gel implants have been the dominating implant type. Many implants can lead to complications, such as hardening and rupture, and may therefore need in vivo evaluation by imaging, particularly if they lead to clinical symptoms. They can also pose problems in the assessment of surrounding breast tissue by conventional mammography. In this respect, imaging modalities such as ultrasound, computed tomography and magnetic resonance imaging offer greater possibilities to assess a failing implant, as well as surrounding breast tissue. Several factors, mainly of a psychological nature, lead to requests for breast implants. In this review article, only the imaging aspects of breasts with silicone gel implants will be dealt with. Each modality is concisely presented with its possibilities and limitations.

Breast Implantation↗

Evaluation of planar scintimammography with 99mTc-MIBI in the detection of axillary lymph node metastases of breast carcinoma.

PURPOSE: The aim of our prospective study was to evaluate the role of planar scintimammography with 99mTc-MIBI in detecting axillary lymph node metastases in women with primary breast carcinoma. MATERIAL AND METHODS: Fifty-eight patients underwent scintimammography rior to axillary lymph node dissection. Ten minutes after injection of 700 MBq 99mTc-MIBI, two prone lateral projections were obtained, followed by a supine anterior projection. Sixty-one axillae (3 bilateral) were operated upon and the status of the lymph nodes verified with histopathology. The scintigraphic result was compared to the histopathologic findings. RESULTS: A sensitivity of 67% and a specificity of 80% of planar scintimammography in detecting axillary lymph node metastases were achieved. CONCLUSION: Scintimammography with 99mTc-MIBI is not recommended as a routine method for the detection of axillary lymph node metastases in patients with breast carcinoma.

Axilla↗

Comparison of planar and SPECT scintimammography with 99mTc-sestamibi in the diagnosis of breast carcinoma.

PURPOSE: To compare results of planar and SPECT breast imaging with 99mTc-MIBI in detecting primary breast cancer. MATERIAL AND METHODS: Twenty-six consecutive patients with 34 suspected breast lesions underwent both planar and SPECT scintimammography. Ten minutes after injection of 700 MBq 99mTc-MIBI, 2 prone lateral projections were obtained, followed by a supine anterior projection. Forty minutes after injection, a SPECT study was done. All lesions were operated upon and verified with histopathology. RESULTS: A sensitivity of 85% and specificity of 88% of planar scintimammography in diagnosis of primary breast lesions were achieved. The corresponding values for SPECT were 61% and 64%. CONCLUSION: The diagnostic accuracy of planar scintimammography was not improved by using SPECT imaging.

Breast↗

Sensitivity and specificity of planar scintimammography with 99mTc-sestamibi.

PURPOSE: The aim of our prospective study was to determine the diagnostic accuracy of planar breast imaging with 99mTc-MIBI in detecting malignant disease. MATERIAL AND METHODS: Ninety-six consecutive patients with 121 clinically- and/or mammographically-detected breast lesions underwent preoperative planar scintimammography. Ten minutes after injection of 700 MBq 99mTc-MIBI, two lateral prone and one anterior supine projections with an acquisition time of 8 minutes each were obtained. Interpretation of scintimammographic results was made blindly and any focal accumulation of MIBI in the breasts was the criterion for an abnormal scintigram. All lesions were operated on and histologically verified. RESULTS: Histologically, 86 malignant and 35 benign lesions were found in 121 breast lesions. A sensitivity of 83.7% and a specificity of 74.2% for malignancy was achieved at planar scintimammography. CONCLUSION: Scintimammography with 99mTc-MIBI is an imaging modality of modest usefulness in the investigation of breast lesions. The method has a low sensitivity in lesions smaller than 10 mm in diameter, which decreases the clinical use of the method.

Adult↗

Contrast-enhanced MR imaging as a prognostic indicator of breast cancer.

BACKGROUND: Using contrast-enhanced MR imaging in the diagnosis of breast cancer may provide additional information not only on tumor extension but also on the biological behavior of tumors. Thus certain characteristics such as tumor angiogenesis and the proliferating activity of the tumor, which have been shown to correlate significantly with prognosis, are both potentially amenable to analysis by MR imaging. MATERIAL AND METHODS: We compared contrast enhancement in 50 malignant breast tumors at MR imaging to several prognostic factors, such as tumor size, lymph-node status, histological grade of malignancy, tumor angiogenesis, and proliferating activity as shown by the mitotic count and PCNA immunoreactivity. RESULTS: There was significant correlation between contrast enhancement at MR imaging of breast cancer and both tumor angiogenesis and proliferative cellular activity as shown by PCNA immunoreactivity. Furthermore, there was a correlation between contrast enhancement and tumor malignancy grade as well as tumor invasiveness. CONCLUSION: These observations suggest that contrast enhancement at MR imaging may be influenced by factors that have prognostic value. If this assumption is correct, contrast-enhanced MR imaging may become a valuable prognostic tool in the pre-operative evaluation of breast cancers.

Breast Neoplasms↗

Mechanism of contrast enhancement in breast lesions at MR imaging.

PURPOSE: The aim of the study was to explain why breast lesions are enhanced by contrast medium at MR imaging and to elucidate the histopathological basis for the overlap in the enhancement patterns of benign and malignant breast lesions. MATERIAL AND METHODS: Ten invasive breast carcinomas and 10 benign breast lesions were selected for the study. Of the 10 carcinomas, 5 showed a strong and early contrast enhancement, and 5 did not. Of the 10 benign lesions, 5 showed a strong and early contrast enhancement, and 5 showed no enhancement. The following morphometric variables were evaluated: proliferation cell index of neoplastic parenchymal cells, S-phase fraction, nuclear ploidy analysed by image DNA-cytometry, microvessel density, and the percentage proportion of the interstitial area. RESULTS: Contrast enhancement was related to the proliferating activity of the hyperplastic or neoplastic parenchymal cells and was inversely correlated with the interstitial area in carcinomas as well as in benign tumours and non-neoplastic lesions of the breast. CONCLUSION: Morphometric variables play an important role in the general mechanism of MR contrast enhancement in examinations of the breast and explain the histopathological basis for the overlap in the enhancement patterns of benign and malignant breast lesions.

Breast↗

Comparison of the contrast enhancement pattern in two different T1-weighted 3-D sequences in MR imaging of the breast.

PURPOSE: Can a complementary 3-D T1-weighted sequence (MPRAGE) facilitate the evaluation of contrast enhancement in patients with widespread and early contrast enhancement in our standard 3-D T1-weighted FLASH sequence? MATERIAL AND METHODS: Twenty patients with 27 breast lesions were examined with both FLASH and MPRAGE sequences. The MR examinations were reviewed independently by three radiologists. RESULTS: In both the FLASH and MPRAGE sequences, 11 lesions were true-positive. In the FLASH sequence alone, 3 lesions were true-negative and 13 false-positive in comparison to the MPRAGE sequence alone in which 10 lesions were true-negative and 6 false-positive. Seven lesions that were false-positive in the FLASH sequence were true-negative in the MPRAGE sequence: this shows that MPRAGE has the potential to downgrade the false-positive findings found in the FLASH sequence. CONCLUSION: Due to its higher sensitivity, FLASH is the sequence of first choice at routine examination. However, when atypical increased enhancement was found, the addition of the MPRAGE sequence improved the specificity of the MR investigation.

Adult↗