Search PubMed⌕ Search

Biomedical subjects

B Bjellqvist

Publications and source records attributed to B Bjellqvist.

22 records · Page 2Linked to original sources

Plasma protein map: an update by microsequencing.

The reference plasma protein map, obtained with immobilized pH gradients in the first dimension of two-dimensional electrophoresis, is presented. By microsequencing, more than 40 polypeptide chains were identified. The new polypeptides and previously known proteins are listed in a table and labeled on the protein map, thus providing an update of the human plasma two-dimensional gel database.

Amino Acid Sequence↗

Improving the detection of proteins after transfer to polyvinylidene difluoride membranes.

N-Terminal sequence analysis of proteins separated by two-dimensional polyacrylamide gel electrophoresis and transferred onto polyvinylidene difluoride (PVDF) membranes has become the method for molecular characterization of proteins contained in biological samples. However, the proteins of lower abundance cannot be sequenced directly, without improving the technique. We have studied a drying method on several PVDF membranes including Trans-Blott, Immobilon P and Problott. Using Amido Black, Coomassie Brilliant Blue R-250 and Ponceau S, we have obtained, in comparison with the non-dried membranes, an enormous increase in the number of detectable proteins.

Electrophoresis, Gel, Two-Dimensional↗

Reference points for comparisons of two-dimensional maps of proteins from different human cell types defined in a pH scale where isoelectric points correlate with polypeptide compositions.

A highly reproducible, commercial and nonlinear, wide-range immobilized pH gradient (IPG) was used to generate two-dimensional (2-D) gel maps of [35S]methionine-labeled proteins from noncultured, unfractionated normal human epidermal keratinocytes. Forty one proteins, common to most human cell types and recorded in the human keratinocyte 2-D gel protein database were identified in the 2-D gel maps and their isoelectric points (pI) were determined using narrow-range IPGs. The latter established a pH scale that allowed comparisons between 2-D gel maps generated either with other IPGs in the first dimension or with different human protein samples. Of the 41 proteins identified, a subset of 18 was defined as suitable to evaluate the correlation between calculated and experimental pI values for polypeptides with known composition. The variance calculated for the discrepancies between calculated and experimental pI values for these proteins was 0.001 pH units. Comparison of the values by the t-test for dependent samples (paired test) gave a p-level of 0.49, indicating that there is no significant difference between the calculated and experimental pI values. The precision of the calculated values depended on the buffer capacity of the proteins, and on average, it improved with increased buffer capacity. As shown here, the widely available information on protein sequences cannot, a priori, be assumed to be sufficient for calculating pI values because post-translational modifications, in particular N-terminal blockage, pose a major problem. Of the 36 proteins analyzed in this study, 18-20 were found to be N-terminally blocked and of these only 6 were indicated as such in databases. The probability of N-terminal blockage depended on the nature of the N-terminal group. Twenty six of the proteins had either M, S or A as N-terminal amino acids and of these 17-19 were blocked. Only 1 in 10 proteins containing other N-terminal groups were blocked.

Amino Acid Sequence↗

The influence of the support material used on band sharpness in Immobiline gels.

To achieve excellent isoelectrofocusing results with the use of Immobiline gels, the quality of the support is essential. Effects such as diffuse bands, missing protein fractions, streaking and trailing could originate from a support of inadequate quality. Two different treatments to eliminate these effects were evaluated. A washing procedure improves the band sharpness, and addition of carrier ampholytes eliminates streaking and trailing.

Buffers↗