Evaluation of diastolic function with Doppler echocardiography: the PDF formalism.

A new parametrized diastolic filling (PDF) formalism for evaluation of holodiastolic (left and right) ventricular function via Doppler echocardiography is presented. It is motivated by the empiric observation that during diastole the heart behaves as a suction pump whose dynamics, in certain respects, are those of a damped harmonic oscillator. An expression for elastic recoil (suction) initiated ventricular diastolic fluid inflow velocity v(t) is obtained by differentiation from the solution x(t) of the linear differential equation that describes the motion of a forced, damped harmonic oscillator. It is solved for "over-damped" motion, for zero initial velocity and initial displacement = xo cm. An explicit forcing term F(t) = Fosin(omega t) is included to account for late diastolic (atrial) filling. The quantitative parameters of the model include inertia (mass; m), viscosity (damping constant; c), source of stored energy for suction (spring constant; k), and its initial displacement xo, the amplitude and frequency of the (atrial) forcing term Fo, omega. The mathematical behavior of the solution v(t) and its dependence on the parameters xo, c, and k, which characterize the contour of the Doppler velocity profile (DVP), is discussed. When clinical examples of normal and abnormal transmitral DVPs are compared with v(t) calculated using the harmonic oscillator model, excellent agreement [DVP-v(t)]/v(t) approximately 0.05 is obtained throughout diastole. Thus the model allows accurate qualitative and quantitative characterization of global ventricular diastolic behavior by noninvasive means in a variety of normal and abnormal stiffness-compliance states. In addition, it may serve as a prototype for a class of mathematical models that can encompass the essential dynamic elements of ventricular diastolic function that couple to flow and further enhance the role of the heart as a suction pump.

Animals↗

Quantitative ultrasonic tissue characterization with real-time integrated backscatter imaging in normal human subjects and in patients with dilated cardiomyopathy.

We have shown previously that the physical properties of myocardium in dogs can be characterized with quantitative ultrasonic integrated backscatter and that interrogation of the tissue with ultrasound can delineate cardiac cycle-dependent changes in ultrasonic backscatter in normal tissue that disappear with ischemia and reappear with reperfusion if functional integrity is restorable. To determine whether this approach can be applied to man, we implemented an automatic gain compensation and continuous data acquisition system to characterize myocardium with quantitative ultrasonic backscatter and to detect cardiac cycle-dependent changes in real time. We developed a two-dimensional echocardiographic system with quantitative integrated backscatter imaging capabilities for use in human subjects that can automatically differentiate ultrasonic signals from blood as opposed to those obtained from tissue and adjust the slope of the gain compensation appropriately. Real-time images were formed from a continuous signal proportional to the logarithm of the integrated backscatter along each A-line. In our initial investigation, 15 normal volunteers (ages 17 to 40 years, heart rates 44 to 88 beats/min) and five patients with dilated cardiomyopathy (ages 22 to 52, heart rates 82 to 120 beats/min) were studied with conventional parasternal long-axis echocardiographic views. Diastolic-to-systolic variation of integrated backscatter in the interventricular septum and left ventricular posterior wall was seen in each of the normal subjects averaging 4.6 +/- 1.4 dB (SD) and 5.3 +/- 1.5 dB (n = 127 sites), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Quantitative ultrasonic characterization of the nature of atherosclerotic plaques in human aorta.

To determine the feasibility of quantitative ultrasonic techniques to define the composition of atherosclerotic plaques, samples of freshly excised human aortas were sewn to a sample holder and immersed in a saline bath for ultrasonic interrogation. Integrated backscatter of a 2-microsecond portion of the backscattered radiofrequency signal was measured with a 10 MHz focused transducer. Integrated backscatter was calculated by normalizing the root-mean-square voltage of the gated signal to the root-mean-square voltage obtained by replacing the tissue sample with a nearly perfect reflector. Microscopic examination of the 124 interrogated sites allowed differentiation of normal, fibrous, fibrofatty, and calcified regions. A site was considered calcified if it contained any histochemically detectable calcium. Values of integrated backscatter were markedly elevated from calcified regions (-30.0 +/- 6.4 dB, n = 25; mean +/- SD; p less than 0.001) compared to normal (-43.2 +/- 2.4 dB, n = 20) and fibrofatty (-43.9 +/- 3.4 dB, n = 43) sites. Values from fibrous regions (-40.7 +/- 3.8 dB, n = 36) were also significantly different compared with the calcified and fibrofatty regions (p less than 0.001). Thus, we have demonstrated that quantitative ultrasonic backscatter identifies and differentiates calcification and fibrosis in atherosclerotic sites offering promise for the noninvasive assessment of the pathologic status of the arterial wall.

Aorta↗

Noninvasive detection by Doppler echocardiography of combined ventricular septal rupture and mitral regurgitation in acute myocardial infarction.

The diagnosis of combined ventricular septal rupture and mitral regurgitation complicating acute myocardial infarction is difficult and in previously reported cases has required right and left heart catheterization. This study utilized simultaneous Doppler and two-dimensional echocardiography to diagnose these combined lesions in two cases. Doppler echocardiography should have its greatest impact in the early noninvasive diagnosis of these complications.

Aged↗

Applicability of ultrasonic tissue characterization for longitudinal assessment and differentiation of calcification and fibrosis in cardiomyopathy.

Progress in tissue characterization of myocardium with ultrasound suggests that quantitative recognition of ischemic or scarred tissue will be achieved. Despite the increasing recognition and importance of cardiomyopathy, its diagnosis generally requires invasive procedures such as cardiac catheterization and biopsy. To investigate methods that permit the characterization of longitudinal cardiomyopathic changes that might ultimately be extended for noninvasive studies in patients, quantitative ultrasonic methods were utilized for in vitro tissue characterization of hearts from Syrian hamsters of selected age of either 2 to 3 or 5 to 7 months. Normal hamsters were used as controls. Myocardial sites (n = 600) from the young Syrian hamsters exhibited values (+/- standard error) of integrated ultrasonic backscatter averaging -53.87 +/- 0.26 dB, which were significantly different from values (n = 500) in age-matched control hamsters (-58.07 +/- 0.08 dB; p less than 0.001). Cardiomyopathic hearts from older animals exhibited backscatter values (n = 500 sites) averaging -50.87 +/- 0.22 dB, again significantly different from values (n = 300 sites) in age-matched control hamsters (-55.91 +/- 0.11 dB; p less than 0.001). In addition, ultrasonic attenuation was significantly different for hearts from the control and cardiomyopathic hamsters of both age ranges. The results correlated with sequential calcification and fibrosis characteristics assessed histopathologically. This study indicates that quantitative characterization of myocardium with ultrasound may permit longitudinal assessment of cardiomyopathic changes in diverse disease entities and their response to therapy.

Age Factors↗

Effects of myocardial contraction on ultrasonic backscatter before and after ischemia.

To determine whether contraction and relaxation influence quantitative myocardial ultrasonic backscatter we measured systolic and diastolic integrated backscatter separately in 10 pentobarbital-anesthetized dogs with defined, paced heart rates, before and after coronary occlusion. Data were acquired from intramural sites by coupling a broadband 5-MHz transducer to the left ventricular epicardium. Integrated backscatter was obtained from seven sequential ECG gated intervals throughout the cardiac cycle over the frequencies of 2.5-7.5 MHz and referenced to values obtained with a steel reflector. Before coronary occlusion myocardium in all dogs exhibited a decrease in integrated backscatter from end diastole to end systole (P less than 0.05) in control zones and in zones destined to become ischemic (P less than 0.05). Thirty minutes after occlusion integrated backscatter did not change in control zones but was elevated in ischemic zones with blunting of the diastolic-to-systolic variation. Thus myocardium undergoing contraction exhibits a decrease in integrated backscatter, and measurement of integrated backscatter at end systole differentiates ischemic from normal myocardium.

Analysis of Variance↗

Changes in myocardial backscatter throughout the cardiac cycle.

This investigation was performed to identify and quantify systematic variations of myocardial ultrasonic backscatter throughout the cardiac cycle. Using a broadband 5 MHz focused transducer coupled to the epicardial surface of the left ventricle in dogs, backscatter measurements were obtained from each of 7 intervals (windows) of 34 milliseconds duration evenly distributed throughout the cardiac cycle and referenced to backscatter from a steel reflector. Values of integrated backscatter obtained demonstrated a consistent and reproducible pattern throughout the cardiac cycle characterized by elevated values at end-diastole and significantly lower values at end-systole. The average maximum difference was 3.5 dB.

Animals↗

Electrocardiographic changes in concussion.

A patient is described in whom electrocardiographic changes simulating acute nontransmural myocardial infarction occurred in association with head trauma. Despite extensive noninvasive investigation, including computerized axial tomography and myocardial scanning, no acute structural central nervous system or cardiac abnormality could be detected. A review of the literature failed to reveal a similar case of these electrocardiographic changes occurring in the absence of organic brain or cardiac pathology.

Aged↗

Ultrasonic myocardial tissue characterization in the operating room: initial results using transesophageal echocardiography.

Ultrasonic tissue characterization provides quantitative assessment of myocardial function and viability. We have previously reported that normal myocardium is characterized by a diastolic-to-systolic cyclic variation of integrated backscatter (IB), whereas ischemic myocardium exhibits blunting of this pattern. To define the applicability of this measurement to characterize the left ventricular myocardium in the operating room, we studied 26 consecutive patients undergoing open heart surgery (12 coronary artery bypass graft, 13 valvular, 1 other) with 5 MHz transesophageal echocardiography. Images of the left ventricle were obtained in the short-axis plane (papillary muscle level) before cardiopulmonary bypass. M-mode acquisition of myocardial IB was attempted from the anterior and inferior segments in each patient. The cyclic variation of IB was measured in at least two consecutive cycles in addition to a qualitative assessment of wall motion. Quantitative measurement of IB was possible in 39/52 (75%) myocardial segments. Cyclic variation of IB averaged 5.7 +/- 1.4 dB (SD) in segments with normal wall motion (n = 25); no difference was noted in the cyclic variation of IB among anterior or inferior walls. Hypokinetic segments demonstrated significant reduction of the cyclic variation (3.8 +/- 1.8 dB; p less than 0.001). Difficulty with obtaining myocardial IB was related to near-field artifact or lateral displacement of the left ventricular wall during systole. Transesophageal echocardiography holds promise for the evaluation of myocardial function and its preservation during cardiac surgery.

Aged↗

Detection of remote myocardial infarction with quantitative real-time ultrasonic characterization.

We have previously shown that the intrinsic properties of myocardium can be characterized quantitatively by the assessment of ultrasonic integrated backscatter. In this study we utilized a novel, real-time, two-dimensional system capable of quantitative integrated backscatter imaging to determine whether zones of remote myocardial infarction in dogs could be delineated definitively by ultrasonic tissue characterization. Detection of such zones in patients is needed as a basis for management decisions related to thrombolysis, angioplasty, and coronary surgery. Integrated backscatter was measured through the closed chest from 25 myocardial sites. Zones of infarction exhibited time-averaged integrated backscatter values approximately 10 dB (9.5 +/- 0.5 dB, standard error of the mean) greater than those in normal regions (p less than 0.001). In addition, the physiologic cardiac cycle--dependent variation of integrated backscatter was blunted significantly in zones of infarction [0.8 dB +/- 0.3 vs. 3.8 +/- 0.6 (p less than 0.01) for normal regions]. Ultrasonic results matched the histopathologic features assessed directly. Thus quantitative ultrasonic tissue characterization can differentiate infarcted tissue from normal myocardium and offers promise for quantitative detection of histopathology in vivo.

Animals↗

The role of transthoracic echocardiography in the management of patients seen in an outpatient cardiology clinic.

Transthoracic two-dimensional (2D) Doppler echocardiography may provide new or additional information in patients, but it is often not known whether the results alter the treatment plan. We investigated whether results of clinically indicated 2D echocardiography were different from the physician's clinical examination or led to changes in management in 200 consecutive outpatients seen in a university-based clinic. A questionnaire was completed by the physician regarding physical findings and treatment plan before 2D echocardiography was performed. After results were known, the physician was asked to report any differences compared with clinical examination or changes in patient management. Most patients (83%) were studied to evaluate left ventricular (LV) or valvular function. 2D echocardiography confirmed clinical assessment in 182 patients (one inadequate 2D echocardiogram) and disclosed a new diagnosis in 17. 2D echocardiography provided additional information, not expected from clinical assessment or history, in 94 patients. Clinical assessment, compared with 2D echocardiography, was concordant in 154 (77%) of 199 patients with regard to LV systolic function but in only 22 (50%) of 44 with valve disease. Alterations in management based on results of 2D echocardiography were instituted in 73 patients (36%), most often manifested by changes in pharmacologic therapy (n = 45; 62%). Results of 2D echocardiography obviated the need for further cardiac evaluation, surgery, or procedures in 30 patients, avoiding additional patient charges of $125,754.00. In contrast, results of 2D echocardiography led to the need for further evaluation, surgery, or procedures in 32 patients, resulting in additional patient charges of $70,860.00. In conclusion, 2D echocardiography provides new or additional information that results in changes in management strategy in one third of patients, and 2D echocardiography offers relative cost savings by avoiding additional procedures.

Adolescent↗

A model of right ventricular failure after global myocardial ischemia and mechanical left ventricular support.

Postcardiotomy right ventricular (RV) failure after institution of mechanical left ventricular (LV) support is poorly understood. Using a canine model supported by cardiopulmonary bypass (CPB), the animals underwent 30 min of aortic clamping or no ischemia and were weaned to an LV assist device (LVAD). Echocardiographic measurements of LV and RV cavity size off support allowed calculation of percentage change in cavity area (fractional shortening). There were no differences at baseline. After 2 hrs on LVAD, there were significant differences between ischemic and control groups in both LV (38 +/- 12 vs. 61 +/- 6) and RV (15 +/- 3 vs. 55 +/- 12). The ischemic RV also had significantly decreased function compared with the LV (38 +/- 12 vs. 15 +/- 3). The control group demonstrated no differences in ventricular function. The authors concluded that global ischemia diminishes LV and RV function, and this effect is accentuated in the RV after LVAD support. In controls, RV function is not affected by LVAD support, but after ischemia, LVAD support alone often will be inadequate.

Animals↗