Estimation of arterial compliance in aortic regurgitation: three methods evaluated in pigs.

Three methods for measuring arterial compliance when aortic regurgitation is present are examined. The first two methods are based on a Windkessel model composed of two elements, compliance C and resistance R. Arterial compliance was estimated from diastolic pressure waveforms and diastolic regurgitant flow for one method, and from systolic aortic pressure waveforms and systolic flow for the other method. The third method was based on a three-element Windkessel model, composed of characteristic resistance r, compliance C and resistance R. In this method arterial compliance was calculated by adjusting the model to the modulus and phase of the first harmonic term of the aortic input impedance. The three methods were compared and validated in six anaesthetised pigs over a broad range of aortic pressures. The three methods were found to give quantitatively similar estimates of arterial compliance at mean aortic pressures above 60 mm Hg. Below 60 mm Hg, estimates of arterial compliance varied widely, probably because of poor validity of the Windkessel models in the low pressure range.

Animals↗

Quantification of aortic regurgitation by Doppler echocardiography: a new method evaluated in pigs.

We have developed a method to quantify aortic regurgitant orifice and volume, based on measurements of the velocity of the regurgitant jet, aortic systolic flow, the systolic and diastolic arterial pressures, a Windkessel arterial model, and a parameter estimation technique. In six pigs we produced aortic regurgitant flows between 2.1 and 17.8 ml per beat, i.e. regurgitant fractions from 0.06 to 0.58. Pulmonary and aortic flows were measured with electromagnetic flow probes, aortic pressure was measured invasively, and the regurgitant jet velocity was obtained with continuous-wave Doppler. The parameter estimation procedure was based on the Kalman filter principle, resulting primarily in an estimate of the regurgitant orifice area. The area was multiplied by the velocity integral of the regurgitant jet to estimate regurgitant volume. A strong correlation was found between the regurgitant volumes obtained by parameter estimation and the electromagnetic flow measurement. These results from our study in pigs suggest that it may be possible to quantify regurgitant orifice and volume in patients completely noninvasively from Doppler and blood pressure measurements.

Animals↗

Autocorrelation length of normal and myopathic human myocardium measured by acoustic microscopy: implications for clinical ultrasonic tissue characterization.

The pattern of acoustic speckle present in ultrasonic images of tissue may be affected by pathological changes in the tissue. To investigate the possibility for such an effect in dilated cardiomyopathy, we examined acoustic micrographs of frozen sections of normal (autopsy) and myopathic (transplant recipient) human myocardium. The resulting images were digitized, and the major axis autocorrelation length calculated for each image. For the normal specimens (n = 75, four patients), the mean autocorrelation length was 37 +/- 18 microns, with the maximum value of 92 microns. The myopathic specimens (n = 64, four patients) had a mean of 52 +/- 19 microns, with a maximum of 100 microns. We conclude that the changes in structure between normal and myopathic myocardium are significant (p less than 0.001), but on so small a scale in relation to the wave length of clinical ultrasound that there will only be changes in the intensity of the backscattered signal, not the pattern of speckle.

Acoustics↗

Estimation of regurgitant volume and orifice in aortic regurgitation combining CW Doppler and parameter estimation in a Windkessel-like model.

A method for noninvasive estimation of regurgitant orifice and volume in aortic regurgitation is proposed and tested in anesthetized open chested pigs. The method can be used with noninvasive measurement of regurgitant jet velocity with continuous wave ultrasound Doppler measurements together with cuff measurements of systolic and diastolic systemic pressure in the arm. These measurements are then used for parameter estimation in a Windkessel-like model which include the regurgitant orifice as a parameter. The aortic volume compliance and the peripheral resistance are also included as parameters measurements in the open chest pigs are used. Electromagnetic flow measurements in the ascending aorta and pulmonary artery are used for control, and a correlation between regurgitant volume obtained from parameter estimation and electromagnetic flow measurements of 0.95 over a range from 2.1 to 17.8 mL is obtained.

Animals↗

Intravascular ultrasound as a guiding modality for mechanical atherectomy and laser ablation.

One of the most compelling practical applications for intravascular ultrasound imaging is in enhancing the safety and efficacy of the second-generation catheter devices designed to ablate or remove plaque. Initial studies have shown that intravascular ultrasound is well suited to demonstrate the amount of atheroma present in a vessel, and the distribution within the vessel wall at any given point. Further clinical studies are required to determine whether more complete debulking of atheroma, guided by ultrasound imaging, has a favorable impact in reducing the rates of acute closure and restenosis following the procedure.

Angioplasty, Laser↗

Analysis of backscattered ultrasound from normal and diseased arterial wall.

Intra-arterial ultrasonic imaging has several features which affect the feasibility of clinical tissue characterization when compared with trans-thoracic ultrasound. The short distance from transducer to tissue, fluid path, high frequencies, and special characteristics of the tissues of interest all contribute to making practical tissue characterization by measurement of the backscattered signal more probable in intra-arterial imaging. The properties of backscattered ultrasound, and methods of characterizing such signals, are discussed with special reference to intra-arterial applications.

Acoustics↗

The initial clinical evaluation of a transesophageal system with pulsed Doppler, continuous wave Doppler, and color flow imaging based on an annular array technology.

The application of transesophageal echocardiography (TEE) offers access to a great deal of important clinical information regarding cardiovascular anatomy and physiology. Two applications which have not been reported and would appear to be of interest are continuous wave Doppler capabilities and the implementation of higher frequency transducers. A TEE system designed at the Institute of Biomedical Engineering in Trondheim, which is based on an annular array technology, offers these capabilities. We evaluated this instrument in the clinical setting in a series of 30 patients to test the probe function in terms of the tissue and flow imaging quality with a 7.5 MHz carrier frequency, and to report on the implementation of a continuous wave Doppler modality in a TEE probe. We found that the annular array method permitted the use of high frequency probes for tissue and flow imaging which resulted in excellent image resolution, and that shifting the carrier frequency of the transducer to a lower frequency permitted the optimization of the Doppler sensitivity. The continuous wave Doppler was used to measure abnormal blood flow velocities in excess of 5.0 m/s, and was particularly useful in the operating room as velocity measurements could be obtained without compromising the sterile field. The results of our evaluation indicate that high imaging frequencies and continuous wave Doppler can be applied by an annular array TEE transducer.

Adolescent↗

Cross sectional early mitral flow velocity profiles from colour Doppler.

Instantaneous cross sectional flow velocity profiles from early mitral flow in 10 healthy men were constructed by time interpolation of the velocity data from each point in sequentially delayed two dimensional digital Doppler ultrasound maps. This interpolation allows correction of the artificially produced skewness of velocities across the flow sector caused by the time taken to scan the flow sector for velocity recording of pulsatile blood flow. These results suggested that early mitral flow studied in an apical four chamber view is variably skewed both at the leaflet tips and at the annulus. The maximum flow velocity overestimated the cross sectional mean velocity at the same time by a factor of 1.2-2.2. Also the maximum time velocity integral overestimated the cross sectional mean time velocity integral to the same extent. This cross sectional skew must be taken into account when calculation of blood flow is based on recordings with pulsed wave Doppler ultrasound from a single sample volume.

Adolescent↗

Non-invasive estimation of pulmonary artery systolic pressure with Doppler ultrasound.

Systolic pressure in the pulmonary artery was estimated from the interval between pulmonary valve closure and tricuspid valve opening, and the heart rate using a nomogram previously described. The timing of valve movements was recorded by Doppler ultrasound. The estimated pressure correlated well with that obtained at catheterisation in 45 of 48 patients with pulmonary hypertension. Instantaneous variations in pressure and changes with treatment and during exercise could be measured. The method was easy to apply in all age groups, and was found useful both in detecting pulmonary hypertension and in the follow-up of patients. It may help to determine the optimal time for surgery or the effect of treatment.

Adolescent↗

Non-invasive assessment of aortic stenosis by Doppler ultrasound.

The peak pressure drop across the aortic valve in aortic stenosis has been measured by Doppler ultrasound. Maximum velocity in the Doppler signal from the aortic jet was recorded using a maximum frequency estimator. With an angle close to zero between ultrasound beam and maximal velocity in the jet, peak pressure drop can be calculated from the maximal velocity measured; a larger angle will underestimate maximal velocity and pressure drop. In 57 of 63 patients with aortic stenosis, the aortic jet could be reached by the ultrasound beam and, in 37 of these, peak pressure drop by ultrasound was compared with that obtained at catheterisation. In patients less than 50 years of age the aortic jet was easy to find, the measurement was reproducible, and underestimation of the pressure drop obtained at catheterisation was within 25 per cent in 17 of 18 patients. In patients over 50 years Doppler signals from the aortic jet were more difficult to obtain, and pressure drop was significantly underestimated in one-third, but time of maximum velocity in systole could indicate whether moderate or severe aortic stenosis was present.

Adolescent↗

Diagnosis of valvular heart disease using transcutaneous Doppler ultrasound.

An ultrasonic Doppler instrument capable of measuring mean and maximum velocities inside a small sample volume is presented. The instrument has been used for determining velocities in normal and diseased heart valves. A method is described for identifying the different heart valves, based on their relation to one another as well as the form of the velocity curve. The pressure drop across the mitral valve can be determined from the maximum velocity and the mean velocity can be used to determine the degree of aortic insufficiency. Recordings of mean and maximum velocities can give an indication of the form of the whole spectrum, thus making complete frequency analysis unnecessary for most purposes.

Aorta, Thoracic↗