Search PubMed⌕ Search

Biomedical subjects

Augusto Azuara-Blanco

Publications and source records attributed to Augusto Azuara-Blanco.

6 recordsLinked to original sources

Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice.

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 +/- 0.28 minutes, 2.31 +/- 0.28 minutes, and 4.14 +/- 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF.

Aged↗

Quantification of interpoint topographic correlations of threshold values in glaucomatous visual fields.

PURPOSE: The authors sought to quantify neighboring and distant interpoint correlations of threshold values within the visual field in patients with glaucoma. METHODS: Visual fields of patients with confirmed or suspected glaucoma were analyzed (n = 255). One eye per patient was included. Patients were examined using the 32 program of the Octopus 1-2-3. Linear regression analysis among each of the locations and the rest of the points of the visual field was performed, and the correlation coefficient was calculated. The degree of correlation was categorized as high (r(2) > 0.66), moderate (0.66 > or = r(2) > 0.33), or low (r(2) < or = 0.33). The standard error of threshold estimation was calculated. RESULTS: Most locations of the visual field had high and moderate correlations with neighboring points and with distant locations corresponding to the same nerve fiber bundle. Locations of the visual field had low correlations with those of the opposite hemifield, with the exception of locations temporal to the blind spot. The standard error of threshold estimation increased from 0.6 to 0.9 dB with an r(2) reduction of 0.1. CONCLUSION: Locations of the visual field have highest interpoint correlation with neighboring points and with distant points in areas corresponding to the distribution of the retinal nerve fiber layer. The quantification of interpoint correlations may be useful in the design and interpretation of visual field tests in patients with glaucoma.

Female↗

Aqueous shunts for intractable glaucoma in infants.

BACKGROUND AND OBJECTIVE: To evaluate the long-term outcome of aqueous shunts in the treatment of infantile glaucoma refractory to conventional treatment. PATIENTS AND METHODS: The records of all patients up to 3 years of age managed with aqueous shunts for uncontrolled glaucoma between November 1990 and November 1996 were retrospectively reviewed. Ten eyes of 6 patients were included in the study. RESULTS: The mean preoperative intraocular pressure (IOP) was 29.75 +/- 4.15 (mm Hg; SD), with none of the eyes on antiglaucoma medication. Postoperatively, the mean IOP was 18.25 +/- 5.34 (mm Hg; SD) at a mean follow up of 50 +/- 25.6 (SD) months with 7 eyes on topical antiglaucoma medication. At the final follow up, 6 eyes were considered successfully controlled without reintervention, 2 more were controlled after shunt revision, and 2 were considered failures. CONCLUSIONS: Aqueous shunts were relatively effective in this series of infants with recalcitrant glaucoma.

Aqueous Humor↗