Search PubMed⌕ Search

Biomedical subjects

Audrey Smith

Publications and source records attributed to Audrey Smith.

4 recordsLinked to original sources

The diverse cardiac morphology seen in hearts with isomerism of the atrial appendages with reference to the disposition of the specialised conduction system.

Congenital cardiac malformations which include isomerism of the atrial appendages are amongst the most challenging of problems for diagnosis and also for medical and surgical management. The nomenclature for pathological description is controversial, but difficulties can be overcome by the use of a segmental approach. Such an approach sets out the morphology and the topology of the chambers of the heart, together with the types and modes of the atrioventricular, ventriculo-arterial, and venous connections. We have applied this method to a study of 35 hearts known to have isomerism of the atrial appendages. We have already published accounts of 27 of these cases, but these were reviewed for this study in the light of our increased awareness of the implications of isomerism, and 8 new cases were added. After examining, or re-examining, the morphology of every heart in detail, we grouped them together according to their ventricular topology and modes of atrioventricular connection. Then we studied the course of the specialised conduction system, by the use of the light microscope, first in each individual case, and then together in their groups. We conclude that the pathways for atrioventricular conduction in hearts with isomerism of the atrial appendages are conditioned both by ventricular topology, and by the atrioventricular connections. Based on our experience, we have been able to establish guidelines that direct the clinician to the likely location of the conduction tissues.

Atrial Appendage↗

Carbon nanotube-chitosan system for electrochemical sensing based on dehydrogenase enzymes.

Multiwalled carbon nanotubes (CNT) were solubilized in aqueous solutions of a biopolymer chitosan (CHIT). The CHIT-induced solubilization of CNT facilitated their manipulations, including the modification of electrode surfaces for sensor and biosensor development. The colloidal solutions of CNT-CHIT were placed on the surface of glassy carbon (GC) electrodes to form robust CNT-CHIT films, which facilitated the electrooxidation of NADH. The GC/CNT-CHIT sensor for NADH required approximately 0.3 V less overpotential than the GC electrode. The susceptibility of CHIT to chemical modifications was explored in order to covalently immobilize glucose dehydrogenase (GDH) in the CNT-CHIT films using glutaric dialdehyde (GDI). The stability and sensitivity of the GC/CNT-CHIT-GDI-GDH biosensor allowed for the interference-free determination of glucose in the physiological matrix (urine). In pH 7.40 phosphate buffer solutions, linear least-squares calibration plots over the range 5-300 microM glucose (10 points) had slopes 80 mA M(-1) cm(-2) and a correlation coefficient 0.996. The detection limit was 3 microM glucose (S/N = 3). The CNT-CHIT system represents a simple and functional approach to the integration of dehydrogenases and electrodes, which can provide analytical access to a large group of enzymes for wide range of bioelectrochemical applications including biosensors and biofuel cells.

Biosensing Techniques↗