Heart failure: a central factor in progressive mechanical and electrical cardiac dysfunction.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Arthur J Moss.
Explore the source record for details and available documents.
Long QT syndrome, a rare genetic disorder associated with life-threatening arrhythmias, has provided a wealth of information about fundamental mechanisms underlying human cardiac electrophysiology that has come about because of truly collaborative interactions between clinical and basic scientists. Our understanding of the mechanisms that control the critical plateau and repolarization phases of the human ventricular action potential has been raised to new levels through these studies, which have clarified the manner in which both potassium and sodium channels regulate this critical period of electrical activity.
In this study, we detail our recent experience with 2 successful Internet-based virtual cardiac symposia that focused on the Brugada syndrome and the long QT syndrome. The responses from cardiologists around the world exceeded our expectations, and clearly, this approach answered an unmet need and has major educational potential. Although we initiated the Virtual Cardiac Symposia with the idea of assisting cardiologists caring for patients with relatively infrequent cardiac conditions, we believe that this Internet-based educational approach will have similar applicability and value for cardiologists caring for patients with common cardiac disorders.
BACKGROUND: The implanted cardioverter defibrillator (ICD) improves survival in high-risk cardiac patients. This analysis from the MADIT-II trial database examines the long-term clinical course and subsequent mortality risk of patients after termination of life-threatening ventricular tachyarrhythmias by an ICD. METHODS AND RESULTS: Life-table survival analysis was performed, and proportional hazards regression analysis was used to evaluate the contribution of baseline clinical factors and time-dependent defibrillator therapy to mortality during long-term follow-up. Of 720 patients with an ICD (average follow-up 21 months), 169 patients received 701 antiarrhythmic device therapies for ventricular tachyarrhythmias. Few baseline characteristics distinguished patients who received appropriate ICD therapy for their first ventricular tachyarrhythmic episode. The probability of survival for at least 1 year after first therapy for ventricular tachycardia (VT) or ventricular fibrillation (VF) was 80%. The hazard ratios for the risk of death due to any cause in those who survived appropriate therapy for termination of VT and VF were 3.4 (P<0.001) and 3.3 (P=0.01), respectively, compared with those who survived without receiving ICD therapy, with a high frequency of heart failure and late nonsudden cardiac death after first successful ICD therapy for VF. CONCLUSIONS: Successful appropriate therapy by an ICD for VT or VF is associated with 80% survival at 1 year after arrhythmia termination. These patients are at increased risk for heart failure and nonsudden cardiac death after device termination of VT or VF and should receive special attention for the prevention and management of progressive left ventricular dysfunction during long-term follow-up.
Explore the source record for details and available documents.
OBJECTIVES: This study aimed to determine whether increased QT interval variability is associated with an increased risk for ventricular tachycardia (VT) or ventricular fibrillation (VF), documented by interrogation of the implantable cardioverter-defibrillator (ICD), in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II. BACKGROUND: Unstable repolarization has been proposed as a risk factor for re-entrant arrhythmias, but confirmatory data from clinical trials are lacking. METHODS: The QT variability was assessed in 10-min, resting high-resolution electrocardiogram recordings at study entry using a semiautomated algorithm that measured beat-to-beat QT duration in 817 MADIT II patients. The incidence of VT/VF requiring device therapy was determined by ICD interrogation. RESULTS: Median normalized QT variability (QTVN) was 0.179 and 0.125, respectively, in patients with VT/VF versus those without VT/VF (p = 0.001); QTVI (QTVN adjusted for heart rate variance) also was significantly (p < 0.05) higher in VT/VF patients than in those without VT/VF. Either QTVN or QTVI was linked with a significantly higher probability of VT/VF: two-year risk of VT/VF from Kaplan-Meier curves was 40% in highest quartile versus 21% in lower quartiles for QTVN, and 37% versus 22% for QTVI (p < 0.05 for each). In multivariate Cox regression models adjusting for clinical covariates (race, New York Heart Association functional class, time after myocardial infarction), top-quartile QTVI and QTVN were independently associated with VT/VF (hazard ratio for QTVN 2.18, 95%confidence interval [CI] 1.34 to 3.55, p = 0.002; hazard ratio for QTVI 1.80, 95% CI 1.09 to 2.95, p = 0.021). CONCLUSIONS: In postinfarction patients with severe left ventricular dysfunction, increased QT variability, a marker of repolarization lability, is associated with an increased risk for VT/VF.
The present study retrospectively explored the reasons for delay in the onset of survival benefit from the implanted cardioverter defibrillator (ICD) in the Second Multicenter Automatic Defibrillator Implantation Trial. The cumulative probability of cause-specific death over time was estimated by the Kaplan-Meier method and by proportional hazards regression analysis. Early cardiac death survival curves were similar by treatment assignment in the 0- to 12-month period (p = 0.76). Late cardiac death survival curves by treatment assignment in the >12- to 52-month follow-up period were divergent with a lower probability of late cardiac death in the ICD arm compared with conventional therapy group (p <0.001). The time-specific hazard ratios of ICD to conventional therapy for cardiac death in the early and late periods were significantly different from each other (nominal p = 0.004). There was a significant decrease in sudden cardiac death with ICD therapy in the early (p = 0.012) and late (p <0.001) groups. In the early period, the rate of nonsudden cardiac death was significantly higher in the ICD group than in the conventional therapy group (p = 0.003). Rates of late nonsudden cardiac death were similar in the 2 treatment arms (p = 0.11).
OBJECTIVES: The purpose of this study was to determine the efficacy of implantable cardiac defibrillator (ICD) therapy in preventing sudden cardiac death (SCD) in post-infarction patients with advanced left ventricular (LV) dysfunction. BACKGROUND: The Multicenter Automatic Defibrillator Implantation Trial (MADIT-II) randomized 1,232 post-infarction patients with an ejection fraction of < or =30% to ICD or conventional therapy. In the ICD group, there was a 31% decrease in the risk of total mortality. However, a better understanding of the mode of death is desirable in order to refine therapeutic interventions in high-risk populations. METHODS: We evaluated the 202 deaths, using a variation of the Hinkle-Thaler classification system as well as a clinical classification system to determine the incidence of SCD and the incidence of cardiac death due to progressive LV failure. RESULTS: The SCD rates were 10.0% in the conventional group and 3.8% in the ICD group (p < 0.01). The hazard ratio for the risk of SCD in the ICD group compared with the conventional therapy group was 0.33 (95% confidence interval 0.20 to 0.53, p < 0.0001). The ICD had no meaningful effect on non-sudden death (p = 0.32). The effect of defibrillator therapy in reducing SCD was similar in subgroup analyses stratified according to relevant baseline characteristics. CONCLUSIONS: The decrease in mortality with ICD therapy in MADIT-II is entirely due to a reduction in SCD, with similar reductions in SCD in a spectrum of subgroups stratified according to relevant baseline characteristics.
BACKGROUND: The management of long-QT syndrome (LQTS) patients who continue to have cardiac events (CEs) despite beta-blockers is complex. We assessed the long-term efficacy of left cardiac sympathetic denervation (LCSD) in a group of high-risk patients. METHODS AND RESULTS: We identified 147 LQTS patients who underwent LCSD. Their QT interval was very prolonged (QTc, 543+/-65 ms); 99% were symptomatic; 48% had a cardiac arrest; and 75% of those treated with beta-blockers remained symptomatic. The average follow-up periods between first CE and LCSD and post-LCSD were 4.6 and 7.8 years, respectively. After LCSD, 46% remained asymptomatic. Syncope occurred in 31%, aborted cardiac arrest in 16%, and sudden death in 7%. The mean yearly number of CEs per patient dropped by 91% (P<0.001). Among 74 patients with only syncope before LCSD, all types of CEs decreased significantly as in the entire group, and a post-LCSD QTc <500 ms predicted very low risk. The percentage of patients with >5 CEs declined from 55% to 8% (P<0.001). In 5 patients with preoperative implantable defibrillator and multiple discharges, the post-LCSD count of shocks decreased by 95% (P=0.02) from a median number of 25 to 0 per patient. Among 51 genotyped patients, LCSD appeared more effective in LQT1 and LQT3 patients. CONCLUSIONS: LCSD is associated with a significant reduction in the incidence of aborted cardiac arrest and syncope in high-risk LQTS patients when compared with pre-LCSD events. However, LCSD is not entirely effective in preventing cardiac events including sudden cardiac death during long-term follow-up. LCSD should be considered in patients with recurrent syncope despite beta-blockade and in patients who experience arrhythmia storms with an implanted defibrillator.
BACKGROUND: Prophylactic implantable defibrillators (ICDs) improve survival in patients with impaired ventricular function after myocardial infarction (MI), but it is uncertain whether mortality risk and survival benefit depend on the elapsed time from MI. METHODS AND RESULTS: The Multicenter Automatic Defibrillator Implantation Trial II examined the impact of ICDs on survival in post-MI patients with ejection fractions < or =30%. In 1159 patients, mean time from most recent MI to enrollment was 81+/-78 months. Patients were randomized to an ICD (n=699) or conventional care (n=460) in a 3:2 ratio. Mortality rates (deaths per 100 person-years of follow-up) in both treatment groups were analyzed by time from MI divided into quartiles (<18, 18 to 59, 60 to 119, and > or =120 months). In conventional care patients, these rates increased as time from MI increased (7.8%, 8.4%, 11.6%, 14.0%; P=0.03). Mortality rates in ICD patients were consistently lower in each quartile and showed minimal increase over time (7.2%, 4.9%, 8.2%, 9.0%; P=0.19). Covariate-adjusted hazard ratios for risk of death associated with ICD therapy were 0.97 (95% CI, 0.51 to 1.81; P=0.92) for recent MI (<18 months) and 0.55 (95% CI, 0.39 to 0.78; P=0.001) for remote MI (> or =18 months). CONCLUSIONS: Mortality risk in patients with ejection fractions < or =30% increases as a function of time from MI. The survival benefit associated with ICDs appears to be greater for remote MI and remains substantial for up to > or =15 years after MI.
BACKGROUND: Among coronary disease patients, concomitant peripheral arterial disease is a potent risk factor for future cardiac events and mortality. We sought to determine clinical and biochemical markers that might better elucidate the relationship between coronary and peripheral arterial disease. METHODS: Two months after an index myocardial infarction, 1045 patients provided detailed medical histories and underwent blood testing for selected hemostatic, lipid, and inflammatory markers. Patients were then followed up prospectively for a mean of 26 months. RESULTS: Compared with individuals without intermittent claudication (n = 966), those with claudication (n = 78) (information was unavailable for 1 individual) were significantly older and demonstrated an increased frequency of diabetes mellitus, tobacco use, prior cardiac and cerebrovascular events, and depressed left ventricular function. Individuals with claudication were less likely to receive beta-blocker therapy after the index infarction. Individuals with claudication had evidence of enhanced procoagulant and proinflammatory states manifested by relative elevations in plasma fibrinogen, D-dimer, C-reactive protein, and serum amyloid A concentrations. During follow-up, the presence of claudication was associated with an independent 2-fold increase in the combined end point of death or nonfatal cardiac event (38.5% vs 17.8%, P =.001) and a 5-fold increase in cardiac mortality (19.2% vs 3.6%, P =.001). Patients with intermittent claudication who were not treated with beta-blockers had a significant 3-fold mortality excess relative to those receiving beta-blockers. CONCLUSIONS: Following myocardial infarction, the added presence of intermittent claudication is associated with heightened procoagulant and proinflammatory states and an underuse of beta-blocker therapy and is a strong independent predictor of recurrent cardiovascular events.
The adult treatment panel III (ATP III) of the National Cholesterol Education Program recognizes metabolic syndrome (MS) as a secondary target for risk-reduction therapy given the well-known increase in risk of cardiovascular disease (CVD) by all MS components. We investigated potential CVD risk arising from 17 laboratory variables in postinfarction patients with MS by identifying such patients from the Thrombogenic Factors and Recurrent Coronary Events (THROMBO) study using slightly modified ATP III criteria for MS. This gave 272 patients with MS out of a total of 766 postinfarction patients without history of diabetes. Comparison between non-MS and MS patients using Kaplan-Meier analysis revealed no difference in outcome between groups. Additionally, a proportional hazards model applied to dichotomized laboratory parameters demonstrated only apoB as a significant predictor of risk for recurrent coronary events in MS patients with hazard ratio, 1.97 (95% CI; 1.08, 3.60; P < 0.05). We conclude that there is no difference in outcomes between non-MS and MS postinfarction patients; that apoB is significantly associated with risk for recurrent coronary events in postinfarction patients with MS; that further studies would be needed to recommend the routine determination of apoB in these patient groups.
Explore the source record for details and available documents.
The automatic ICD improves survival in patients with a history of sudden cardiac arrest. However, some patients do not meet the guidelines for ICD implantation or are unable to receive an implantable device. This study tested the hypothesis that these patients could benefit from a wearable cardioverter defibrillator. Patients with symptomatic heart failure and an ejection fraction of <0.30 (WEARIT Study) or patients having complications associated with high risk for sudden death after a myocardial infarction or bypass surgery not receiving an ICD for up to 4 months (BIROAD Study) were enrolled into two studies. After a total of 289 patients had been enrolled in the trial (177 in WEARIT and 112 in BIROAD), prespecified safety and effectiveness guidelines had been met. Six (75%) of eight defibrillation attempts were successful. Six inappropriate shock episodes occurred during 901 months of patient use (0.67% unnecessary shocks per month of use). Twelve deaths occurred during the study 6 sudden deaths: 5 not wearing and 1 incorrectly wearing the device). Most patients tolerated the device although 68 patients quit due to comfort issues or adverse reactions. The results of the present study suggest that a wearable defibrillator is beneficial in detecting and effectively treating ventricular tachyarrhythmias in patients at high risk for sudden death who are not clear candidates for an ICD and may be useful as a bridge to transplantation or ICD in some patients.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Careful assessment of QT interval prolongation is required before novel drugs are approved by regulatory authorities. The choice of the most appropriate method of electrocardiogram (ECG) acquisition and QT/RR interval measurement in clinical trials requires better understanding of the differences among currently available approaches. This study compared standard and Holter-derived 12-lead ECGs for utility in detecting sotalol-induced QT/QTc and RR changes. Manual methods (digitizing pad and digital on-screen calipers) were compared for precision of QT and RR interval measurement. METHODS AND RESULTS: Sixteen hundred pairs of serial 12-lead digital ECGs were recorded simultaneously by standard resting ECG device and by continuous 12-lead digital Holter over 3 days in 39 healthy male and female volunteers. No therapy was given on the 1st day followed by 160 mg and 320 mg of sotalol on the 2nd and 3rd day, respectively. Holter-derived and standard ECGs produced nearly identical sotalol-induced QT/QTc and RR changes from baseline, as did the manual digipad and on-screen caliper measurements. The variability of on-screen QT measurement in this study was greater than that of digipad. CONCLUSIONS: Digital 12-lead Holter and standard 12-lead ECG recorders, as well as the manual digitizing pad and digital on-screen calipers, are of equal utility for the assessment of drug-induced change from baseline in QT and RR interval, although the variability of the on-screen method in this study was greater than of the digipad.