A feasibility study of contrast enhancement of acute myocardial infarction in multislice computed tomography: comparison with magnetic resonance imaging and gross morphology in pigs.

INTRODUCTION: Late enhancement magnetic resonance imaging (MRI) of myocardial infarction (MI) is clinically established. There are no reports on MI assessment using state-of-the-art multislice CT technology. For this reason, animal experiments were conducted to examine the applicability of contrast-enhanced ECG-gated multislice computed tomography (MSCT) for the detection of acute MI. The results were correlated with MRI and postmortem tissue staining. MATERIAL AND METHODS: Acute MI was induced in 14 pigs by balloon occlusion of the LAD. In 8 animals, the LAD was reperfused after 45 minutes. In 6 animals, the LAD was permanently blocked. MR imaging was performed 15 minutes after the administration of 0.2 mmol Gd-DTPA/kg/bodyweight. Subsequently, 16-slice MSCT was performed at various timepoints after injecting 120 mL of iodinated contrast medium. 2,3,5-Triphenyltetrazolin-chloride (TTC) staining was acquired for all hearts investigated. Correlation analysis was applied to compare the area of MI derived from MRI, MSCT, and TTC. The reperfused infarcts were compared with the nonreperfused infarcts using an unpaired t test. RESULTS: : Mean infarct area as measured by TTC staining was 18.3% +/- 7.8% of the left ventricular area. Good correlation of the spatial extent of the infarcted area was found for TTC and MRI as well as for TTC and MSCT data obtained 5 minutes postcontrast injection. MSCT imaging demonstrated a significant difference in density (P < 0.001) between nonreperfused (47.0 +/- 6.6 HU) and reperfused (116.4 +/- 19.8 HU) infarction. CONCLUSION: In our pilot study, contrast-enhanced MSCT was feasible to assess myocardial viability in pigs. MSCT also affords differentiation of nonreperfused and reperfused acute MI. MI sizes derived from MSCT imaging correlate well to those obtained with MRI and TTC.

Animals↗

MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs.

PURPOSE: To assess the feasibility of percutaneous magnetic resonance (MR)-guided intramyocardial injection of gadodiamide by using real-time imaging and to quantify T1 values and the size of the enhanced region for different concentrations of contrast agent for 30 minutes after injection. MATERIALS AND METHODS: Animal care committee approval was obtained. A catheter with a needle tip was advanced into the left ventricle in seven pigs by using real-time imaging with radial steady-state free precession. After intramyocardial injection of 2 mL of solution at concentrations of 0.05 or 0.10 mmol/mL gadodiamide, local changes in T1 values and size of the contrast material-enhanced region were sequentially measured at 3, 15, and 30 minutes after injection by using the Look-Locker sequence. Two-tailed paired Student t tests were used for statistical analysis. RESULTS: Catheter guidance and visualization of contrast agent distribution were feasible in all animals. Regional changes in T1 values were significantly different for different contrast agent concentrations (for 0.05 mmol/mL, 456 msec +/- 5 [+/- standard error of the mean]; for 0.10 mmol/mL, 228 msec +/- 4; P < .001) measured 3 minutes after injection. T1 values increased significantly (P < .05) to 720 msec +/- 7 for 0.05 mmol/mL gadodiamide and 445 msec +/- 6 for 0.10 mmol/mL gadodiamide 30 minutes after injection but remained significantly lower than those of remote myocardium (879 msec +/- 8). The size of the contrast-enhanced region increased from 13 mm(2) +/- 2 at 3 minutes to 30 mm(2) +/- 3 at 30 minutes (P < .05). CONCLUSION: Catheter MR-guided percutaneous intramyocardial injection is feasible; after intramyocardial injection of gadodiamide at concentrations of 0.05 and 0.10 mmol/mL, T1 values decreased over the observation time.

Animals↗

Spin-labeling coronary MR angiography with steady-state free precession and radial k-space sampling: initial results in healthy volunteers.

The purpose of this study was to prospectively compare free-breathing navigator-gated cardiac-triggered three-dimensional steady-state free precession (SSFP) spin-labeling coronary magnetic resonance (MR) angiography performed by using Cartesian k-space sampling with that performed by using radial k-space sampling. A new dedicated placement of the two-dimensional selective labeling pulse and an individually adjusted labeling delay time approved by the institutional review board were used. In 14 volunteers (eight men, six women; mean age, 28.8 years) who gave informed consent, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, vessel length, and subjective image quality were investigated. Differences between groups were analyzed with nonparametric tests (Wilcoxon, Pearson chi2). Radial imaging, as compared with Cartesian imaging, resulted in a significant reduction in the severity of motion artifacts, as well as an increase in SNR (26.9 vs 12.0, P < .05) in the coronary arteries and CNR (23.1 vs 8.8, P < .05) between the coronary arteries and the myocardium. A tendency toward improved vessel sharpness and vessel length was also found with radial imaging. Radial SSFP imaging is a promising technique for spin-labeling coronary MR angiography.

Adult↗

Malignant right coronary artery anomaly simulated by motion artifacts on MDCT.

OBJECTIVE: The aim of our study was to determine the prevalence of anomalous right coronary artery imitation due to motion artifacts in MDCT. Routine chest MDCT for reasons other than cardiac or vascular imaging is usually performed using breath-hold technique but without retrospective ECG gating and consequently yields pulsating motion artifacts. A possible artifact in front of the aortic root imitates an anomalous right coronary artery originating from the left posterior sinus. This course of the right coronary artery is considered a malignant variant and raises the question of far-reaching consequences such as a bypass operation. SUBJECTS AND METHODS: We performed a prospective study involving 355 patients undergoing routine chest CT examinations. To determine the prevalence of anomalous right coronary artery imitation caused by this motion artifact, all images were evaluated prospectively by an experienced radiologist. RESULTS: Twenty-one patients (5.9%) were suspected of having a malignant variant of the right coronary artery. However, in all patients prior chest CT or additional coronary MR angiography showed a normal origin of the right coronary artery. CONCLUSION: Routine chest MDCT without retrospective ECG gating may produce artifacts around the aorta simulating a malignant variant of the right coronary artery. Considering the low incidence of this malignant interarterial variant, the need for routine chest CT examinations combined with ECG gating and further workup can be disputed from an economic point of view. This artifact should be known to avoid unnecessary further examinations.

Adult↗

Minimally invasive close-chest method for creating reperfused or occlusive myocardial infarction in swine.

RATIONALE AND OBJECTIVES: We sought to evaluate a closed-chest model for reperfused and occlusive myocardial infarction (MI) in pigs and to report experiences and pitfalls. MATERIAL AND METHODS: In 44 pigs, a balloon catheter was advanced into the left descending coronary artery (LAD) under fluoroscopic guidance. The balloon was inflated and occlusion of the vessel angiographically confirmed while ECG was continuously monitored. In case of ventricular fibrillation, direct current defibrillation was performed. In 6 animals, the balloon was left inflated during the following experiments, to obtain occlusive MI. In all other cases, the balloon was deflated after 45 minutes. After the experiments were finished, the hearts were stained with 2,3,5-triphenyltetrazolium chloride for assessment of infarct size. RESULTS: MI was successfully induced in 34 animals (28 reperfused and 6 occlusive). Mean size of MI was 15.8 +/- 5.1% of left ventricular surface area for reperfused and 21.5 +/- 8.7% for occlusive infarcts. In one pig, 2,3,5-triphenyltetrazolium chloride did not confirm infarction. In 26 pigs, ventricular fibrillation occurred. Defibrillation was successful in 17 pigs. Failure rate because of ventricular fibrillation decreased from 42% (6) in the first 14 to 10% (3) in the next 30 animals. One animal died due to technical failure of the ventilator. After initial experiences, we used balloon catheters with a diameter of 2-3 mm, instead of 4 mm. The smaller balloon sizes were used so as to decrease the incidence of fibrillation. CONCLUSIONS: The described technique of LAD occlusion presents a less invasive alternative to open chest models. The major pitfall, causing fatal arrhythmia in our series, was over-dilatation of the LAD with the balloon catheter.

Animals↗

In vivo magnetic resonance imaging of coronary thrombosis using a fibrin-binding molecular magnetic resonance contrast agent.

BACKGROUND: The advent of fibrin-binding molecular magnetic resonance (MR) contrast agents and advances in coronary MRI techniques offers the potential for direct imaging of coronary thrombosis. We tested the feasibility of this approach using a gadolinium (Gd)-based fibrin-binding contrast agent, EP-2104R (EPIX Medical Inc), in a swine model of coronary thrombus and in-stent thrombosis. METHODS AND RESULTS: Ex vivo and in vivo sensitivity of coronary MR thrombus imaging was tested by use of intracoronarily delivered Gd-DTPA-labeled fibrinogen thrombi (n=6). After successful demonstration, in-stent coronary thrombosis was induced by x-ray-guided placement of thrombogenic-coated, MR-lucent stents (n=5). After stent placement, 60 micromol of EP-2104R was injected via the left main coronary artery. Free-breathing, navigator-gated 3D coronary MR angiography and thrombus imaging were performed (1) before and after stent placement and (2) before and after EP-2104R. Thrombi were confirmed by x-ray angiography and autopsy. Fibrinogen thrombi: 5 of 6 intracoronarily delivered Gd-labeled fibrinogen clots (approximately 250 micromol/L Gd) were visible on MRI and subsequently confirmed by x-ray angiography. In-stent thrombi: in-stent thrombosis was observed in all stents after EP-2104R. Four of 5 thrombi were confirmed by x-ray angiography. Chemical analysis of 2 thrombi demonstrated 99 to 147 micromol/L Gd. CONCLUSIONS: We demonstrate the feasibility of MRI of coronary thrombus and in-stent thrombosis using a novel fibrin-binding molecular MR contrast agent. Potential applications include detection of coronary in-stent thrombosis or thrombus burden in patients with acute coronary syndromes.

Animals↗

Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling: comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography--pilot study.

The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.

Adult↗

MR-guided radiofrequency ablation of hepatic malignancies at 1.5 T: initial results.

PURPOSE: To assess the feasibility of magnetic resonance (MR)-guided radiofrequency ablation (RFA) of hepatic malignancies using a high-field MR scanner. MATERIALS AND METHODS: A total of 10 patients with 14 primary (N = 1) or secondary (N = 13) hepatic malignancies underwent MR-guided RFA using a closed-bore 1.5 T MR scanner. Lesion diameters ranged from 2.0 cm to 4.7 cm. RFA was performed using a 200-W generator in combination with a 3.5-cm LeVeen electrode applying a standardized energy protocol. RESULTS: RFA was technically feasible in all patients. Necrosis diameter ranged from 2.5 cm to 6.8 cm. The mean follow-up period is 12.2 (1-18) months. In nine out of 10 patients, local tumor control was achieved. For this purpose, a second CT-guided RFA was required in two patients. In four patients, multifocal hepatic tumor progression occurred, with the treated lesion remaining tumor-free in three of these patients. Two patients showed extrahepatic tumor progression. Four patients remained tumor-free. No major complications occurred. CONCLUSION: MR-guided RFA of hepatic malignancies in a closed-bore high-field MR scanner is technically feasible and safe. It can be advantageous in locations considered unfavorable for CT-guided puncture or in patients in which iodinated contrast material is contraindicated.

Aged↗

In vivo safe catheter visualization and slice tracking using an optically detunable resonant marker.

The purpose of this study was to test the in vivo feasibility of safe automatic catheter tracking based on an optically detunable resonant marker installed on the catheter tip, and also to test the compatibility of this approach with guidewire materials. The design of the resonant marker and the integration into the real-time MR environment is described. The catheter was used for real-time MR-guided catheterization of the aorta, left ventricle, and carotid in two swine. For in-plane visualization, the marker was repeatedly detuned. For automatic slice tracking, a projection difference measurement including detuning was interleaved with the imaging sequence. In vitro experiments were conducted to investigate the RF-safety of the marker and the effect of the guidewires on the signal intensity. For all orientations the marker provided excellent in vivo contrast using a radial steady-state free-precession sequence. Flashing of the marker by repetitive tuning/detuning further improved the in-plane visualization. Automatic slice tracking during real-time imaging was successfully performed. The plastic guidewires did not interfere with the marker, and detuning by guidewires containing nitinol could be compensated. In conclusion, automatic slice tracking as well as excellent in-plane visualization can be achieved with this approach and it is safe with respect to RF transmission.

Animals↗

Use of a nonmetallic guide wire for magnetic resonance-guided coronary artery catheterization.

RATIONALE AND OBJECTIVES: Metallic guide wires can be subject to substantial heating when used in the magnetic resonance (MR) environment. Therefore, animal experiments were performed to test the feasibility of a non-metallic and MR-safe guide wire with passive markers for catheterization of coronary arteries under MR guidance. MATERIALS AND METHODS: Self-made guide wires consisting of a resin-microparticle compound covered by polytetrafluoroethylene were used to catheterize both coronary arteries of swine together with a non-braided catheter. Time needed for catheterization was recorded. RESULTS: MR-guided coronary artery catheterization with passive visualization of a self-made non-metallic guide wire is possible. In average 141 seconds (SD 68) were needed to manipulate the guide wire together with a catheter from the carotid artery into the left or right coronary artery ostium. CONCLUSION: Standard nitinol guide wires have to be considered unsafe for MR-guided interventions due to possible heating of electrical conducting structures in the MR environment. Passive visualization techniques allow MR-guided catheterization of small arteries like coronaries. However, there is the substantial disadvantage of obscuring the underlying anatomy of small vessels by the passive markers needed for real-time MR guidance.

Animals↗

T2-weighted turbo spin-echo images, maximum-intensity projections, and three-dimensional volume-rendering for delineation of pathologies and anatomic details of the inner ear.

PURPOSE: The aim of the current study was to compare 3-dimensional T2-weighted turbo spin-echo (TSE) axial slices, maximum-intensity projections (MIPs), and volume-rendered images with respect to the delineation of pathologic findings and anatomic structures of the inner ear. Each of the compared image types was available at 2 different resolutions. MATERIALS AND METHODS: In 64 patients, 3-dimensional T2-TSE images were acquired with a matrix of 128 x 100 and 230 x 230 (field-of-view 90 x 90 mm). Direct axial images, MIPs, and volume-rendered images from the 2 datasets were evaluated in terms of the delineation of pathologic findings and anatomic structures. Analysis was performed by 2 radiologists in consensus. RESULTS: Though axial images acquired with a matrix of 230 x 230 showed more anatomic details than images acquired with a matrix of 128 x 100, pathologic findings (33 in total) were assessable with the same confidence on images of either resolution. Pathologies completely surrounded by fluid were best assessed on axial slices. The delineation of pathologies not embedded in a fluid was almost equally good in axial slices, MIPs, or 3-dimensional volume-rendered images. CONCLUSION: Reading the axial images cannot be replaced by viewing postprocessed reconstructions for initial diagnosis, because only some of the pathologies can be delineated on MIPs and volume reconstructions. However, reconstructions can be valuable for assessing the extent of pathologies and their spatial relation to the anatomic structures.

Adolescent↗

Coronary artery stents in multislice computed tomography: in vitro artifact evaluation.

RATIONALE AND OBJECTIVE: The aim of this study was to systematically compare the ability to assess the coronary artery lumen in the presence of coronary artery stents in multislice spiral CT (MSCT). METHODS: Ten different coronary artery stents were examined with 4- and 16-detector row MSCT scanners. For image reconstruction, a standard and a dedicated convolution kernel for coronary artery stent visualization were used. Images were analyzed regarding lumen visibility, intraluminal attenuation, and artifacts outside the stent lumen. Results were compared using repeated-measure analysis of variance. RESULTS: Depending on stent type, scanner hardware, and convolution kernel, artificial lumen narrowing ranged from 20% to 100%. The convolution kernel had the most significant influence on the visibility of the stent lumen. Artificial lumen narrowing and intraluminal attenuation changes decreased significantly using the dedicated convolution kernel. In general, most severe artifacts were caused by gold or gold-coated stents. CONCLUSIONS: Independent of the scanner hardware or dedicated convolution kernels, routine evaluation of most coronary artery stents is not yet feasible using MSCT.

Analysis of Variance↗

New metallic MR stents for artifact-free coronary MR angiography: feasibility study in a swine model.

RATIONALE AND OBJECTIVES: The objective of this study was to investigate the potential for artifact-free coronary magnetic resonance angiography (cMRA) in the presence of dedicated metallic MR stents in vitro and in a swine model. METHODS: All investigations were performed at 1.5 T, applying a standard cMRA gradient echo sequence with a T2 preparation pulse. Two prototypes of each hand-woven, mechanically woven, and lasered Aachen Resonance Coronary MR Stents made out of an MR-compatible metallic alloy and dilated to 2.5 mm and 4 mm were examined in a water bath. RESULTS: Artifact behavior was judged independently by 2 radiologists as showing "no artifacts" for all tested stent types. Signal-to-noise ratios inside and outside of the stents were measured yielding a Pearson correlation coefficient of 0.98 (y = 1.22 + 0.92x). Nineteen stents (8 hand woven, 3 mechanically woven, 8 lasered) were deployed in coronary arteries of 19 domestic pigs and were examined by cMRA. Artifact behavior of the stents was analyzed by measuring the signal-to-noise ratio at the stent positions and compared with signal-to-noise ratio measurements outside of the stents, yielding a Pearson correlation coefficient of 0.90 (y = -0.75 + 1.06x). CONCLUSIONS: All 3 prototypes of coronary MR stents allowed complete visualization of the stent lumen and consequently determination of stent patency by cMRA.

Animals↗

Is postcontrast trueFISP imaging advantageous?

RATIONALE AND OBJECTIVES: Contrast of trueFISP images depends mainly on the T2/T1 ratio. Consequently, there is a potential gain in signal intensity after administration of paramagnetic contrast medium despite the strong T2 weighting. The purpose of this study was to analyze signal intensities of abdominal organs after applying contrast medium and to determine whether this yields an improved contrast for pathologies compared with precontrast trueFISP. MATERIALS AND METHODS: Fifty patients underwent an abdominal examination, including the trueFISP sequence before and after the administration of contrast medium. All images were obtained with a 1.5 T system. The mean signal-to-noise ratio before and after contrast medium was assessed for abdominal organs, vessels, muscle, and fat. The contrast-to-noise ratio (CNR) of pathologic lesions was calculated. RESULTS: The trueFISP sequence yielded a higher signal-to-noise ratio after application of contrast medium for all organs except for fat and the aorta. CNR of solid lesions (angiomyolipoma, liver adenoma, liver hemangioma, hepatocellular carcinoma) increased whereas contrast of cysts decreased. CONCLUSIONS: TrueFISP imaging after application of contrast medium led to better CNR for many solid lesions while cysts showed a diminished contrast. We advise trueFISP imaging sequences before and after contrast medium application.

Abdomen↗

Magnetic resonance-guided placement of aortic stents grafts: feasibility with real-time magnetic resonance fluoroscopy.

PURPOSE: The artifact behavior of different aortic stent-grafts was evaluated with real-time magnetic resonance (MR) imaging, and the feasibility of real-time MR-guided stent-graft placement in the abdominal aorta was tested. MATERIALS AND METHODS: Seven different stent-grafts and their deployment systems were analyzed in an in vitro setting regarding their artifacts on different real-time MR images with cartesian, spiral, and radial k-space filling. The device and the real-time sequence with the fewest artifacts were used for an in vivo study in a swine model. In four animals, a straight aortic stent-graft was placed in the infrarenal abdominal aorta under real-time MR guidance. Results were controlled with MR angiography, multislice spiral computed tomography, and digital subtraction angiography. RESULTS: The in vitro study proved only one of the seven stent grafts (including deployment systems) to be suitable for real-time MR-guided intervention. MR-guided placement of the stent-grafts was possible in all animals. In one animal, the stent-graft dislocated during withdrawal of the deployment system as a result of a mismatch between stent-graft diameter and size of the infrarenal aorta. CONCLUSION: Real-time MR-guided placement of stent-grafts in the abdominal aorta with use of commercially available standard instruments is feasible. However, for clinical use, dedicated devices and deployment systems producing less artifacts are required.

Angiography, Digital Subtraction↗

Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: initial results.

BACKGROUND: The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS: Eight healthy volunteers (mean age 29 years) and eight patients (mean age 53 years) were investigated on a 1.5 Tesla MR system (ACS-NT, Philips, Best, The Netherlands). Renal MRA was performed using three navigator-gated free-breathing cardiac-triggered 3D SSFP sequences [repetition time (TR) = 4.4 ms, echo time (TE) = 2.2 ms, flip angle 85 degrees, spatial resolution 1.25 x 1.25 x 4.0 mm(3), scanning time approximately 1 minute 30 seconds]. The same sequence was performed without magnetization preparation, with a non-slab selective and a slab-selective inversion prepulse. Signal-to-noise ratio (SNR), contrast-to-noise (CNR) vessel length, and subjective image quality were compared. RESULTS: Three-dimensional SSFP imaging combined with a slab-selective inversion prepulse enabled selective and high contrast visualization of the renal arteries, including the more distal branches. Standard SSFP imaging without magnetization preparation demonstrated overlay by veins and renal parenchyma. A non-slab-selective prepulse abolished vessel visualization. CNR in SSFP with slab-selective inversion was 43.6 versus 10.6 (SSFP without magnetization preparation) and 0.4 (SSFP with non-slab-selective inversion), P < 0.008. CONCLUSION: Navigator-gated free-breathing cardiac-triggered 3D SSFP imaging combined with a slab-selective inversion prepulse is a novel, fast renal MRA technique without the need for contrast media.

Adult↗

Assessment of myocardial function with interactive non-breath-hold real-time MR imaging: comparison with echocardiography and breath-hold Cine MR imaging.

PURPOSE: To compare a spiral gradient-echo sequence with a radial steady-state free precession sequence and to compare these two interactive real-time cardiac magnetic resonance (MR) imaging examinations with harmonic two-dimensional echocardiography (ECHO) for the evaluation of regional myocardial function. MATERIALS AND METHODS: Electrocardiographically triggered breath-hold steady-state free precession (BH-SSFP) MR imaging was the reference standard. Thirty-five nonselected patients scheduled for routine ECHO were included. Data from corresponding two-, three-, and four-chamber long-axis views and a midventricular short-axis view were acquired with each modality. Image quality and depiction of segmental wall motion were scored semiquantitatively by using the 16-segment model of the American Society of Echocardiography. Repeated-measures analysis of variance was performed to assess differences in image quality and wall motion depiction scores among the four imaging methods. Agreement was assessed by using Cohen kappa statistics. RESULTS: Compared with the image quality achieved with BH-SSFP MR imaging, the image quality achieved with radial MR imaging was similar (nonsignificant difference), but that achieved with spiral MR imaging and ECHO was significantly inferior (P <.0001). There were no significant differences in the image quality of the long- and short-axis views between the radial and BH-SSFP sequences, while the image quality of the long-axis spiral (P <.05) and the short- and long-axis ECHO (P <.0001) views was lower than that of the BH-SSFP views. Compared with the mean wall motion score for BH-SSFP MR imaging, the mean wall motion score for radial MR imaging was not significantly different, but those for ECHO (P <.05) and spiral MR imaging (P =.0003) were significantly lower. Cohen kappa coefficients for agreement with the BH-SSFP sequence regarding wall motion scoring were 0.47 for ECHO, 0.67 for the spiral sequence, and 0.89 for the radial sequence. CONCLUSION: The radial sequence enables similar accurate assessment of regional wall motion compared with the BH-SSFP sequence and yields image quality that is superior to that yielded by the spiral sequence and ECHO.

Adult↗

Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI.

UNLABELLED: The aim of this study was to validate Quantitative Gated SPECT (QGS) and 4D-MSPECT for assessing left ventricular end-diastolic and systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF) from gated (18)F-FDG PET. METHODS: Forty-four patients with severe coronary artery disease were examined with gated (18)F-FDG PET (8 gates per cardiac cycle). EDV, ESV, and LVEF were calculated from gated (18)F-FDG PET using QGS and 4D-MSPECT. Within 2 d (median), cardiovascular cine MRI (cMRI) (20 gates per cardiac cycle) was done as a reference. RESULTS: QGS failed to accurately detect myocardial borders in 1 patient; 4D-MSPECT, in 2 patients. For the remaining 42 patients, correlation between the results of gated (18)F-FDG PET and cMRI was high for EDV (R = 0.94 for QGS and 0.94 for 4D-MSPECT), ESV (R = 0.95 for QGS and 0.95 for 4D-MSPECT), and LVEF (R = 0.94 for QGS and 0.90 for 4D-MSPECT). QGS significantly (P < 0.0001) underestimated LVEF, whereas no other parameter differed significantly between gated (18)F-FDG PET and cMRI for either algorithm. CONCLUSION: Despite small systematic differences that, among other aspects, limit interchangeability, agreement between gated (18)F-FDG PET and cMRI is good across a wide range of clinically relevant volumes and LVEF values assessed by QGS and 4D-MSPECT.