Search PubMed⌕ Search

Biomedical subjects

Antonius Kettrup

Publications and source records attributed to Antonius Kettrup.

49 records · Page 3Linked to original sources

Prediction of soil adsorption coefficients from retention parameters on three reversed-phase liquid chromatographic columns.

Reversed-phase high-performance liquid chromatographic (RP-HPLC) retention parameters, which are determined by the intermolecular interactions in retention process, can be considered as the chemical molecular descriptors in linear free energy relationships (LFERs). On the basis of the characterization and comparison of octadecyl-bonded silica gel (ODS), cyano-bonded silica gel (CN), and phenyl-bonded silica gel (Ph) columns with linear solvation energy relationships (LSERs), a new multiple linear regression model using RP-HPLC retention parameters on ODS and CN columns as variables for estimation of soil adsorption coefficients was developed. It was tested on a set of reference substances from various chemical classes. The results showed that the multicolumn method was more promising than a single-column methpd was for the estimation of soil adsorption coefficients. The accuracy of the suggested model is identical with that of LSERs.

Adsorption↗

Characteristics of electroosmotic flow and migration of neutral solutes under stepwise gradient elution of capillary electrochromatography.

A theoretical study on the velocity of electroosmotic flow (EOF) and the retention times of neutral solutes under multiple-step gradient of capillary electrochromatography (CEC) was carried out, focusing on that with three kinds of mobile phases. Through the model computations, the detaining time of the second kind of mobile phase in the column was proved to play an important role in affecting EOF. The variation speed of EOF was shown to be determined by the differences among dead times in different steps. In addition, the prediction of the retention times of 13 aromatic compounds under gradient mode was performed with the deduced equations. A relative error below 3.3% between the calculated and experimental values was obtained, which demonstrated the rationality of the theoretical deduction. Our study could not only improve the comprehension of stepwise gradient elution, but also be of significance for the further optimization of separation conditions in the analysis of complex samples.

Chromatography, High Pressure Liquid↗

Up-scaling capillary zone electrophoresis separations of polydisperse anionic polyelectrolytes with preparative free-flow electrophoresis exemplified with a soil fulvic acid.

A scale-up of analytical capillary zone electrophoresis (CZE) to preparative free-flow electrophoresis (FFE) is described. FFE allows fractionations based on charge densities in larger amounts than in CZE, enabling further off-line analysis of the fractions. Model compounds (carboxylic acids and polystyrene sulfonates) showed a similar behavior in FFE as in CZE. Diffusion and electrodynamic distortion effects are more pronounced in FFE than in CZE. A soil fulvic acid was analyzed by CZE and fractionated by FFE. A comparison of the FFE fractions with CZE measurements of the same sample using the effective mobility scale showed good agreement of the two methods.

Benzopyrans↗

Determination of glycoalkaloids and relative aglycones by nonaqueous capillary electrophoresis coupled with electrospray ionization-ion trap mass spectrometry.

Glycoalkaloids are naturally occurring nitrogen-containing compounds present in many species of the family Solanaceae, including cultivated and wild potatoes (Solanum spp.), tomatoes (Lycopersicon spp.), etc. These compounds have pharmacological and toxicological effects on humans due to their significant anticholinesterase activity and disruption of cell membranes. Herein is reported the development of a capillary electrophoresis (CE) method using nonaqueous (NA) separation solutions in combination with ion trap mass spectrometry (MS and MS/MS) detection for the identification and quantification of glycoalkaloids and their relative aglycones. A mixture 90:10 v/v of MeCN-MeOH containing 50 mM ammonium acetate and 1.2 M acetic acid (applied voltage of 25.5 kV) was selected as a good compromise for the separation and detection of these compounds. The electrospray MS measurements were carried out in the positive ionization mode using a coaxial sheath liquid, methanol-water (1:1) with 1% of acetic acid at a flow rate of 2.5 microL/min. Under optimized experimental conditions, the predominant ion was the protonated molecular ion ([M+H](+)) of solanidine (m/z = 398), tomatidine (m/z = 416), chaconine (m/z = 852), solanine (m/z = 868), and tomatine (m/z = 1034). MS/MS experiments were carried out systematically by changing the relative collisional energy and monitoring the intensities of the fragment ions that were not high enough to allow better quantification than with the mother ions. The method was used for analyzing glycoalkaloids in potato extracts.

Electrophoresis, Capillary↗

Toxicity evaluation of reactive dyestuffs, auxiliaries and selected effluents in textile finishing industry to luminescent bacteria Vibrio fischeri.

The toxicity of 17 selected process effluents, 11 reactive dyestuffs and 8 auxiliaries from a textile dyeing and finishing mill in Ayazaga, Istanbul, Turkey was evaluated by bioluminescence test using bacteria Vibrio fischeri in LUMIStox 300. The EC20 and EC50 for auxiliaries, the EC20 for dyestuffs were determined. For selected process effluents GL-values, the dilution level at which a wastewater sample causes less than 20% inhibition, were examined. Our results demonstrate that the toxicity assessment with luminescent bacteria is effective and of practical use for chemicals applied in textile finishing industry with the limitation of the deep dark-colored dye bath samples and for the related effluents. Inhibition effects of numerous dyestuffs as well as auxiliaries to luminescent bacteria differed considerably with a range 5-600 mg l(-1) for EC20 and 9-6930 mg l(-1) for EC50, respectively. Among 17 effluents, I sample exhibited high toxicity (GL = 100), 7 showed moderate toxicity (GL = 12-32), and 9 had a GL-value <10 indicating a low or no toxicity.

Coloring Agents↗

Triazines in the aquatic systems of the Eastern Chinese Rivers Liao-He and Yangtse.

The results of a one-year monitoring program on the two Eastern Chinese River systems, i.e. the Liao-He and the Yangtse, with special emphasis on the presence of triazine herbicides are presented. Sediment, suspended solids and water samples from both rivers were analyzed. Additionally, recovery experiments on the SPE-in-field-enrichment procedure and the extraction methods were performed. The samples were measured by gas chromatography coupled with mass spectrometry, electron capture detection and a newly developed mu-plasma atomic emission detector. A typical result of a one-year monitoring was obtained in case of the Liao-He: During winter, at low water period, low triazine values were found. A similar situation was found in early spring. Highest concentrations of atrazine up to 1600 ng/l were found in late spring in the water samples. Maximum concentrations of atrazine, simazine, propazine, simetryn and prometryn were observed in this season as a result of the actual use of triazines. Finally, after the high water period in autumn the triazine concentrations decreased. Additionally, atrazine adsorbed on sediment (up to 2.8 ng/g) and suspended solids was determined (up to 8 ng/l) during late spring sampling. Therefore, the logarithm of the organic carbon based sorption coefficient of atrazine could be calculated. Low levels of atrazine were measured in the water of Yangtse (up to 18.3 ng/l). The concentrations from all sampling points and sampling stations of a particular sampling date were similar, which indicates a homogeneous distribution of this herbicide. Due to the high discharge rate of up to 79,000 m3/s in case of the Yangtse a considerable mass transport of up to 57.5 kg per day atrazine may take place, even at concentrations below the European drinking water limit of 100 ng/l.

Adsorption↗

Half-lives of tetra-, penta-, hexa-, hepta-, and octachlorodibenzo-p-dioxin in rats, monkeys, and humans--a critical review.

The elimination half-lives (t1/2) in Sprague-Dawley rats for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), 1,2, 3,7,8-pentachlorodibenzo-p-dioxin (PeCDD), 1,2,3,4,7,8-hexachlorodibenzo-p-dioxin (HxCDD), 1,2,3,4,6,7,8-heptachlorodibenzo-p-dioxin (HpCDD) and 1,2,3,4,6,7,8,9-octachlorodibenzo-p-dioxin (OCDD) were estimated in long-term studies by Schlatter, Poiger and others. Furthermore, there are some published half-lives of TCDD in adult humans. The average half-life of TCDD in adult humans is approximately 2840 days, while in Sprague-Dawley rats the average t1/2 of TCDD is 19 days. The t1/2 of TCDD in humans is about 150 times that of rats. This factor was used to calculate the t1/2 values of the other polychlorinated dibenzo-p-dioxins (PCDDs) in humans from the rat data. Furthermore, the terminal t1/2 values of PCDDs in adult humans were calculated from the regression equation: logt1/2H = 1.34 logt1/2R + 1.25 which was recently established for 50 xenobiotics (t1/2H = terminal half-lives in days for humans, t1/2R = terminal half-lives in days for rats). The following terminal half-lives in adult humans were obtained: 12.6 years for 1,2,3,7,8-PeCDD, 26-45 years for 1,2,3,4,7,8-HxCDD, 80-102 years for 1,2,3,4,6,7,8-HpCDD and ca. 112-132 years for OCDD. These half-lives of PCDDs are critically compared with measured t1/2 values of PCDDs and other persistent organic pollutants in rats, monkeys and humans.

Animals↗

Influence of methanol on retention of hydrophobic organic chemicals in soil leaching column chromatography.

The influence of methanol in methanol-water mixed eluents on the capacity factor (k'), an important parameter which could depict leaching potential of hydrophobic organic chemicals (HOCs) in soil leaching column chromatography (SLCC), was investigated. Two reference soils, GSE 17201 obtained from Bayer Landwirtschaftszentrum, Monheim, Germany and SP 14696 from LUFA, Spencer, Germany, were used as packing materials in soil columns, and isocratic elution with methanol-water mixtures at different volume fractions of methanol (phi) were tested. Short-term exposure of the column (packed with the GSE 17201 soil) to the eluents increased solute retention by a certain (23% log-unit) degree evaluated through a correlation with the retention on the same soil column but unpreconditioned by methanol-containing eluents. Long-term exposure of soil columns to the eluents did not influence the solute retention. A log-linear equation, log k' = log k'(w) - S(phi), could well and generally describe the retention of HOCs in SLCC. For the compounds of homologous series, logk'(w) had good linear relationship with S, indicating the hydrophobic partition mechanism existing in the retention process.

Chromatography↗

Linear solvation energy relationships regarding sorption and retention properties of hydrophobic organic compounds in soil leaching column chromatography.

The capacity factors of a series of hydrophobic organic compounds (HOCs) were measured in soil leaching column chromatography (SLCC) on a soil column, and in reversed-phase liquid chromatography on a C18 column with different volumetric fractions (phi) of methanol in methanol-water mixtures. A general equation of linear solvation energy relationships, log(XYZ) XYZ0 + mV(I)/100 + spi + bbetam + aalpham, was applied to analyze capacity factors (k'), soil organic partition coefficients (Koc) and octanol-water partition coefficients (P). The analyses exhibited high accuracy. The chief solute factors that control logKoc, log P, and logk' (on soil and on C18) are the solute size (V(I)/100) and hydrogen-bond basicity (betam). Less important solute factors are the dipolarity/polarizability (pi*) and hydrogen-bond acidity (alpham). Log k' on soil and log Koc have similar signs in four fitting coefficients (m, s, b and a) and similar ratios (m:s:b:a), while log k' on C18 and logP have similar signs in coefficients (m, s, b and a) and similar ratios (m:s:b:a). Consequently, logk' values on C18 have good correlations with logP (r > 0.97), while logk' values on soil have good correlations with logKoc (r > 0.98). Two Koc estimation methods were developed, one through solute solvatochromic parameters, and the other through correlations with k' on soil. For HOCs, a linear relationship between logarithmic capacity factor and methanol composition in methanol-water mixtures could also be derived in SLCC.

Adsorption↗

Quantitative structure-property relationships for octanol-air partition coefficients of polychlorinated biphenyls.

Based on nine quantum chemical descriptors computed by PM3 Hamiltonian, using partial least squares analysis, a significant quantitative structure-property relationship for the logarithm of octanol-air partition coefficients (logK(OA)) of polychlorinated biphenyls (PCBs) was obtained. The cross-validated Q2cum value of the model is 0.962, indicating a good predictive ability. The intermolecular dispersive interactions and thus the size of the PCB molecules play a key role in governing log K(OA). The greater the size of PCB molecules, the greater the logK(OA) values. Increasing ELUMO (the energy of the lowest unoccupied molecular orbital) values of the PCBs leads to decreasing logK(OA) values, indicating possible interactions between PCB and octanol molecules. Increasing Q(Cl)+, (the most positive net atomic charges on a chlorine atom) and Q(C)- (the largest negative net atomic charge on a carbon atom) values of PCBs results in decreasing lg K(OA) values, implying possible intermolecular electrostatic interactions between octanol and PCB molecules.

Environmental Pollutants↗

Retention behavior of hydrophobic organic chemicals as a function of temperature in soil leaching column chromatography.

To study the transport mechanism of hydrophobic organic chemicals (HOCs) and the energy change in soil/solvent system, a soil leaching column chromatographic (SLCC) experiment at an environmental temperature range of 20-40 degrees C was carried out, which utilized a reference soil (SP 14696) packed column and a methanol-water (1:4 by volume ratio) eluent. The transport process quickens with the increase of column temperature. The ratio of retention factors at 30 and 40 degrees C (k'30/k'40) ranged from 1.08 to 1.36. The lower enthalpy change of the solute transfer in SLCC (from eluent to soil) than in conventional reversed-phase liquid chromatography (e.g., from eluent to C18) is consistent with the hypothesis that HOCs were dominantly and physically partitioned between solvent and soil. The results were also verified by the linear solvation energy relationships analysis. The chief factor controlling the retention was found to be the solute solvophobic partition, and the second important factor was the solute hydrogen-bond basicity, while the least important factors were the solute polarizability-dipolarity and hydrogen-bond acidity. With the increase of temperature, the contributions of the solute solvophobic partition and hydrogen-bond basicity gradually decrease, and the latter decreases faster than the former.

Adsorption↗

Ozonation of the purified hydrolyzed azo dye Reactive Red 120 (CI).

The combination of chemical and biological water treatment processes is a promising technique to reduce recalcitrant wastewater loads. The key to the efficiency of such a system is a better understanding of the mechanisms involved during the degradation processes. Ozonation has been applied to many fields in water and wastewater treatment. Especially for effluents of textile finishing industry ozonation can achieve high color removal, enhance biodegradability, destroy phenols and reduce the COD. However, little is known about the reaction intermediates and products formed during ozonation. This work focuses on the oxidative degradation of purified (>90%), hydrolyzed Reactive Red 120 (Color Index), a widely used azo dye in the textile finishing processes with two monochlorotriazine anchor groups. Ozonation of the dye in ultra pure water was performed in a laboratory scale cylindrical batch reactor. Decolorization, determined by measuring the light absorbance at the maximum wavelength in the visible range (535 nm), was almost complete after 150 min with an ozone concentration of 12.8 mg/l. The TOC/TOC0 ratio was about 74% and the COD was diminished to 46% of the initial value. The BOD5/COD ratio increased from 0.01 to 0.14. To obtain detailed information on the reaction processes during ozonation and the resulting oxidation products organic and inorganic anions were analyzed. Oxidation and cleavage of the azo group yielded nitrate. Cleavage of the sulfonic acid groups of aromatic rings caused an increase in the amount of sulfate. Formic acid and oxalic acid were identified as main oxidation products by high performance ion chromatography (HPIC). The concentrations of these major products were monitored at defined time intervals during ozonation.

Coloring Agents↗

[Determination of anions in the products of ozonation of reactive dye by ion chromatography].

A method for the determination of anions in the degradation products of C. I. Reactive Red 120 by ozonation was investigated. The sample can be pretreated with a Dionex OnGuard P column, which has high selectivity for removing phenols, azo group-contaning compounds, aromatic carboxylic aicds etc. For the separation of organic and inorganic anions in the products, the anion exchange chromatograhy with gradient elution of NaOH was used. All the species were detected by both suppressed conductivity and UV absorbance detectors. The sulfate, oxalate, chloride, nitrate and formate could be identified even in very low concentration with ion chromatography, within 18 min, with the recoveries between 91.6% - 108.3%. The results indicate that the method is reliable, simple, rapid and especially sensitive. In combining with the determination results of conventional parameters of the solution of Reactive Red 120, a preliminary elucidation of the degradation mechanism

Anions↗