Search PubMed⌕ Search

Biomedical subjects

Antonio R Webb

Publications and source records attributed to Antonio R Webb.

5 recordsLinked to original sources

Hemocompatibility evaluation of poly(glycerol-sebacate) in vitro for vascular tissue engineering.

Poly(glycerol-sebacate) (PGS) is an elastomeric biodegradable polyester that could potentially be used to engineer blood vessels in vivo. However, its blood-material interactions are unknown. The objectives of this study were to: (a) fabricate PGS-based biphasic tubular scaffolds and (b) assess the blood compatibility of PGS in vitro in order to get some insight into its potential use in vivo. PGS was incorporated into biphasic scaffolds by dip-coating glass rods with PGS pre-polymer. The thrombogenicity (platelet adhesion and aggregation) and inflammatory potential (IL-1beta and TNFalpha expression) of PGS were evaluated using fresh human blood and a human monocyte cell line (THP-1). The activation of the clotting system was assessed via measurement of tissue factor expression on THP-1 cells, plasma recalcification times, and whole blood clotting times. Glass, tissue culture plastic (TCP), poly(l-lactide-co-glycolide) (PLGA), and expanded polytetrafluorethylene (ePTFE) were used as reference materials. Biphasic scaffolds with PGS as the blood-contacting surface were successfully fabricated. Relative to glass (100%), platelet attachment on ePTFE, PLGA and PGS was 61%, 100%, and 28%, respectively. PGS elicited a significantly lower release of IL-1beta and TNFalpha from THP-1 cells than ePTFE and PLGA. Similarly, relative to all reference materials, tissue factor expression by THP-1 cells was decreased when exposed to PGS. Plasma recalcification and whole blood clotting profiles of PGS were comparable to or better than those of the reference polymers tested.

Biocompatible Materials↗

Biomechanical characterization of vaginal versus abdominal surgical wound healing in the rabbit.

OBJECTIVE: The objective of the study was to compare biomechanical properties of vaginal versus abdominal surgical wound healing in the rabbit. STUDY DESIGN: Bilateral 6-mm full-thickness circular segments were excised from the vagina and abdominal skin in 38 New Zealand White female rabbits. Animals were killed 0, 4, 7, 10, 14, 21, 28, and 35 days after wounding, and the wounds were assessed for surface area and tensile properties. RESULTS: Wound closure and scar contraction were significantly faster in the vagina than the abdomen (P = .001). Baseline tensile strength (P = .05), modulus (P = .001), and tensile energy to break (P = .18) were higher in the abdomen, whereas maximal tissue elongation was higher in the vagina (P = .13). After wounding, a drop in tensile strength, modulus, and tensile energy to break was observed in both tissues through postwounding day 4, followed by a progressive recovery of these properties. A progressive loss of elasticity was noted in both tissues after wounding. CONCLUSION: The surgical wound closes and contracts faster in the rabbit vagina than in its abdomen. Although these tissues have different biomechanical properties at baseline, they regenerate their tensile strength and lose their elasticity at a similar rate.

Abdomen↗

Synthesis and evaluation of poly(diol citrate) biodegradable elastomers.

Herein, we report the synthesis and evaluation of a novel family of biodegradable and elastomeric polyesters, poly(diol citrates). Poly(diol citrates) were synthesized by reacting citric acid with various diols to form a covalent cross-linked network via a polycondensation reaction without using exogenous catalysts. The tensile strength of poly(diol citrates) were as high as 11.15+/-2.62 MPa and Young's modulus ranged from 1.60+/-0.05 to 13.98+/-3.05 MPa under the synthesis conditions that were investigated. Elongation was as high as 502+/-16%. No permanent deformation was found during mechanical tests. The equilibrium water-in-air contact angles of measured poly(diol citrates) films ranged from 15 degrees to 53 degrees . The mechanical properties, degradation and surface characteristics of poly(diol citrates) could be controlled by choosing different diols as well as by controlling the cross-link density of the polyester network. Various types of poly(diol citrate) scaffolds were fabricated to demonstrate their processing potential. These scaffolds were soft and could recover from deformation. In vitro and in vivo evaluation using cell culture and subcutaneous implantation, respectively, confirmed cell and tissue compatibility. The introduction of poly(diol citrates) will expand the repertoire of currently available biodegradable polymeric elastomers and should help meet the requirements of tissue engineering applications.

Animals↗

Biodegradable polyester elastomers in tissue engineering.

Tissue engineering often makes use of biodegradable scaffolds to guide and promote controlled cellular growth and differentiation in order to generate new tissue. There has been significant research regarding the effects of scaffold surface chemistry and degradation rate on tissue formation and the importance of these parameters is widely recognised. Nevertheless, studies describing the role of mechanical stimuli during tissue development and function suggest that the mechanical properties of the scaffold will also be important. In particular, scaffold mechanics should be taken into account if mechanical stimulation, such as cyclic strain, will be incorporated into strategies to grow improved tissues or the target tissue to be replaced has elastomeric properties. Biodegradable polyesters, such as polyglycolide, polylactide and poly(lactide-co-glycolide), although commonly used in tissue engineering, undergo plastic deformation and failure when exposed to long-term cyclic strain, limiting their use in engineering elastomeric tissues. This review will cover the latest advances in the development of biodegradable polyester elastomers for use as scaffolds to engineer tissues, such as heart valves and blood vessels.

Animals↗

Novel biphasic elastomeric scaffold for small-diameter blood vessel tissue engineering.

Compliance mismatch, thrombosis, and long culture times in vitro remain important challenges to the clinical implementation of a tissue-engineered small-diameter blood vessel (SDBV). To address these issues, we are developing an implantable elastomeric and biodegradable biphasic tubular scaffold. The scaffold design uses connected nonporous and porous phases as a basis to mimic, respectively, the intimal and medial layers of a blood vessel. Biphasic scaffolds were fabricated from poly(diol citrate), a novel class of biodegradable polyester elastomer. Scaffolds were characterized for tensile and compressive properties, burst pressure, compliance, foreign body reaction (via subcutaneous implantation in rats), and cell distribution and differentiation (via histology, scanning electron microscopy, and immunohistochemistry). Tensile tests, burst pressure, and compliance measurements confirm that the incorporation of a nonporous phase to create a "skin" connected to the porous phase of a scaffold can provide bulk mechanical properties that are similar to those of a native vessel. Compression tests confirm that the scaffolds are soft and recover from deformation. Subcutaneously implanted poly(diol citrate) porous scaffolds produce a thin fibrous capsule and allow for tissue ingrowth. In vitro culture of tubular biphasic scaffolds seeded with human aortic smooth muscle cells (HASMCs) and endothelial cells (HAECs) demonstrates the ability of this design to support cell compartmentalization, coculture, and cell differentiation. The newly formed HAEC monolayer stained positive for von Willebrand factor whereas collagen- and calponin-positive HASMCs were present in the porous phase.

Animals↗