Search PubMed⌕ Search

Biomedical subjects

Antonio Giannella-Neto

Publications and source records attributed to Antonio Giannella-Neto.

5 recordsLinked to original sources

Comparative effects of vaporized perfluorohexane and partial liquid ventilation in oleic acid-induced lung injury.

BACKGROUND: It is currently not known whether vaporized perfluorohexane is superior to partial liquid ventilation (PLV) for therapy of acute lung injury. In this study, the authors compared the effects of both therapies in oleic acid-induced lung injury. METHODS: Lung injury was induced in 30 anesthetized and mechanically ventilated pigs by means of central venous infusion of oleic acid. Animals were assigned to one of the following groups: (1) control or gas ventilation (GV), (2) 2.5% perfluorohexane vapor, (3) 5% perfluorohexane vapor, (4) 10% perfluorohexane vapor, or (5) PLV with perfluorooctane (30 ml/kg). Two hours after randomization, lungs were recruited and positive end-expiratory pressure was adjusted to obtain minimal elastance. Ventilation was continued during 4 additional hours, when animals were killed for lung histologic examination. RESULTS: Gas exchange and elastance were comparable among vaporized perfluorohexane, PLV, and GV before the open lung approach was used and improved in a similar fashion in all groups after positive end-expiratory pressure was adjusted to optimal elastance (P < 0.05). A similar behavior was observed in functional residual capacity (FRC) in animals treated with vaporized perfluorohexane and GV. Lung resistance improved after recruitment (P < 0.05), but values were higher in the 10% perfluorohexane and PLV groups as compared with GV (P < 0.05). Interestingly, positive end-expiratory pressure values required to obtain minimal elastance were lower with 5% perfluorohexane than with PLV and GV (P < 0.05). In addition, diffuse alveolar damage was significantly lower in the 5% and 10% perfluorohexane vapor groups as compared with PLV and GV (P < 0.05). CONCLUSIONS: Although the use of 5% vaporized perfluorohexane permitted the authors to reduce pressures needed to stabilize the lungs and was associated with better histologic findings than were PLV and GV, none of these perfluorocarbon therapies improved gas exchange or lung mechanics as compared with GV.

Administration, Inhalation↗

Effects of descending positive end-expiratory pressure on lung mechanics and aeration in healthy anaesthetized piglets.

INTRODUCTION: Atelectasis and distal airway closure are common clinical entities of general anaesthesia. These two phenomena are expected to reduce the ventilation of dependent lung regions and represent major causes of arterial oxygenation impairment in anaesthetic conditions. In the present study, the behavior of the elastance of the respiratory system (Ers), as well as the lung aeration assessed by CT-scan, was evaluated during a descendent positive end-expiratory pressure (PEEP) titration. This work sought to evaluate the potential usefulness of the Ers monitoring to set the PEEP in order to prevent tidal recruitment and hyperinflation of healthy lungs under general anaesthesia. METHODS: PEEP titration (from 16 to 0 cmH2O, with a tidal volume of 8 ml/kg) was performed, and at each PEEP, helical CT-scans were obtained during end-expiratory and end-inspiratory pauses in six healthy, anaesthetized and paralyzed piglets. The distribution of lung compartments (hyperinflated (HA), normally- (NA), poorly- (PA), and non-aerated areas (N)) was determined and the tidal re-aeration was calculated as the difference between end-expiratory and end-inspiratory PA and NA areas. Similarly, the tidal hyperinflation was obtained as the difference between end-inspiratory and end-expiratory HA. The Ers was estimated on a breath-by-breath basis from the equation of motion of the respiratory system during all PEEP titration with the least squares method. RESULTS: HA decreased throughout PEEP descent from PEEP 16 cmH2O to ZEEP (ranges from 24-62% to 1-7% at end-expiratory and from 44-73% to 4-17% at end-inspiratory pauses) whereas NA areas increased (30-66% to 72-83% at end-expiratory and from 19-48% to 73-77% at end-inspiratory pauses). From 16 to 8 cmH2O, Ers decreased with a correspondent reduction in tidal hyperinflation. A flat minimum of Ers was observed from 8 to 4 cmH2O. For PEEP below 4 cmH2O, Ers increased associated with a rise in tidal re-aeration and a flat maximum of the NA areas. CONCLUSION: In healthy piglets under a descending PEEP protocol, the PEEP at minimum Ers presented a compromise between maximizing NA areas and minimizing tidal re-aeration and hyperinflation. High levels of PEEP, greater than 8 cmH2O, reduced tidal re-aeration but enlarged hyperinflation with a concomitant decrease in normally aerated areas.

Anesthesia, General↗

Effects of filtering and delays on the estimates of a nonlinear respiratory mechanics model.

Estimation of mechanical properties of the respiratory system may be disturbed by instrumentation and physical set-up. The effects of lowpass filtering, filter mismatch and inter-channel delay in the digital converter are assessed on numerically simulated signals from a nonlinear model of the respiratory system. Large biases in model parameter estimates (up to about -300% for some parameters) were caused by these instrumental interferences and were reduced by including an inertance in the retrieved model. The results reinforce the importance of a careful evaluation of the instrumental set-up used in physiological measurements.

Airway Resistance↗

Comparison of computerized methods for detecting the ventilatory thresholds.

The aim of this study was to compare computerized automatic methods to detect the ventilatory threshold (VT). Thirty apparently healthy and physically active volunteers [22.5 (6.5) years; 1.72 (0.08) m; 71.9 (8.5) kg] were submitted to a progressive and maximal cycle exercise. The gas exchange was monitored breath-by-breath with a fast gas analyser. The VT and respiratory compensation (RC) were automatically detected based on the respiratory exchange ratio, the ventilatory equivalent for O2 and the ventilatory equivalent for CO2, pulmonary ventilation, end-tidal PO2 and PCO2, and v-slope. In addition, VT and RC were also determined independently by visual inspection by two experienced investigators, and the results were compared with those of the automatic procedures. The automatic VT averaged 77% of the maximal VO2 and the RC 88%. The agreement between the experienced observers was very close [mean difference: 44.4 (16.1) ml, r = 0.94, not significant]. Data were expressed as the mean value together with the standard deviation in each case. The automatic and visual inspection procedures did not present significant differences, resulting in 29.6 (29.6) ml with a reliability of r = 0.86. All methods were significantly correlated for VT and RC (r = 0.93 on average, P < 0.01). ANOVA did not show differences between either the VT methods (P = 0.131) or the RC methods (P = 0.41). In conclusion, the present study has compared several simultaneous breath-by-breath ergospirometric methods that are used to describe the anaerobic threshold, showing high confidence when compared to visual inspection. No statistical differences were found between the VT and RC techniques for physically active subjects indicating that these methods may be equally effectively employed.

Adult↗

A closed-loop mechanical ventilation controller with explicit objective functions.

A closed-loop lung ventilation controller was designed, aiming to: 1) track a desired end-tidal CO2 pressure (Pet CO2), 2) find the positive end-expiratory pressure (PEEP) of minimum estimated respiratory system elastance (Ers,e), and 3) follow objective functions conjectured to reduce lung injury. After numerical simulations, tests were performed in six paralyzed piglets. Respiratory mechanics parameters were estimated by the recursive least squares (RLS) method. The controller incorporated a modified PI controller for Pet CO2 and a gradient descent method for PEEP. In each animal, three automated PEEP control runs were performed, as well as a manual PEEP titration of Ers,e and a multiple PetCO2 step change trial. Overall performance indexes were obtained from PEEP control, such as minimum Ers,e (37.0 +/- 4.5 cmH2O x L(-1)), time to reach the minimum Ers,e (235 +/- 182 s) and associated PEEP (6.5 +/- 1.0 cmH2O), and from Pet CO2 control, such as rise time (53 +/- 22 s), absolute overshoot/undershoot of PetCO2 (3 +/- 1 mmHg), and settling time (145 +/- 72 s). The resulting CO2 controller dynamics approximate physiological responses, and results from PEEP control were similar to those obtained by manual titration. Multiple dependencies linking the involved variables are discussed. The present controller can help to implement and evaluate objective functions that meet clinical goals.

Algorithms↗