Search PubMed⌕ Search

Biomedical subjects

Antonio Colombo

Publications and source records attributed to Antonio Colombo.

207 records · Page 12Linked to original sources

Coronary stenting using a 6 F. diagnostic catheter: a report of two cases.

Standard guiding catheters for coronary interventions may not selectively engage the coronary ostium despite a successful cannulation with a diagnostic catheter of the same curve. This discrepancy is explained by a slight difference in shape between the two catheters (shorter tip of the guiding, absence of tip tapering, etc.). The authors report on the use of 6 F. coronary diagnostic catheters as guiding catheters for coronary angioplasty and stent implantation in two patients with critical stenoses: in the right coronary artery distal to a right internal mammary artery anastomosis in one and in the ostial right coronary artery in the other. In both cases, the use of diagnostic catheters was the key to success despite the vessel orifice being unfavourable for the use of different types of guiding catheters.

Journal Article↗

Clinical and quantitative angiographic outcomes following elective implantation of the self-expanding Wallstent for longer coronary artery lesions--final results of the Wellstent native study.

BACKGROUND: Implantation of short balloon-expandable stents provides superior clinical and angiographic outcome compared with balloon angioplasty in selected patients. The purpose of the Wellstent study was to evaluate the safety and efficacy of the self-expanding Wallstent combined with aspirin and ticlopidine in patients with stable or unstable angina related to a native coronary lesion up to 45 mm in length. METHODS: 105 patients (111 lesions) with stable (57%) or unstable (43%) angina were included in this prospective multicentre evaluation. Angiography before and after Wallstent implantation and at 6-month follow-up was analysed at the core lab using the CAAS 2 system. The primary end-point was incidence of major adverse cardiac events (MACE) at 30 days. Secondary end-points were angiographic outcome at 6 months and MACE at 6 months and 1 year. RESULTS: Acute procedural success (successful stent implantation with residual stenosis <20%) was achieved in 99%. Mean reference diameter was 3.18 +/- 0.66 mm, minimal luminal diameter was 1.00 +/- 0.50 mm pre- and 2.84 +/- 0.47 mm poststent (diameter stenosis 16 +/- 6%). The mean hospital stay was 2.2 days. At 30 days, 95% of patients were free of MACE. At 6 month and 1 year clinical follow-up, 75% and 71% of patients, respectively, remained free of MACE, the majority of which (19 of 30) were re-interventions at re-angiography. In 90% of eligible patients, MLD at follow-up was 1.65 +/- 0.75 mm (late loss 1.20 +/- 0.66 mm, loss index 0.66), diameter stenosis 42 +/- 15%, with a restenosis rate of 32%. Longer stents were associated with greater luminal loss (P = 0.001) and less-favourable clinical outcome. CONCLUSIONS: Wallstent implantation, combined with aspirin and ticlopidine, achieved excellent acute and 30 day clinical results in a heterogenous high-risk patient group. Clinical outcome at 6 months and 1 year remained good, and most adverse events were re-PTCA during follow-up angiography. The loss index of 0.66 and restenosis rate of 32%, related in part to the use of longer stents, emphasizes the continuing need for effective anti-proliferative therapy.

Journal Article↗

Palmaz-Schatz stent embolization: long-term clinical and angiographic follow-up.

A long-term clinical and angiographic follow-up of a case of peripheral coronary stent embolization is reported. No clinical sequelae occurred in the immediate and long-term (five years) followup. The five-year follow-up angiographic images provided visual documentation of absence of stent-associated stenosis. This case highlights the concept that fibro-intimal hyperplasia may not occur when plaque and balloon trauma are absent at the site of stent embolization.

Journal Article↗

Coronary stent implantation throughout technical evolution: immediate and follow-up results.

Coronary stenting (stent implantation) has evolved over the last 5 years with changes in stent design, stent material and the implantation technique. The use of high-pressure balloon inflation (HP), intravascular ultrasound (IVUS) and appropriate antiplatelet therapy have contributed to the abolishment of the need for subsequent anticoagulation, allowing extended stent applications. We compared results in three groups of patients having stent implantation throughout the period of evolution: group A: no IVUS, no HP, with subsequent anticoagulation treatment (n 3 434); group B: no IVUS, yes HP, without subsequent anticoagulation treatment (n 3 192); and group C: yes IVUS, yes HP, without subsequent anticoagulation treatment (n 3 588). The primary success rates were comparable in all groups. There was a clear change in indications for stenting in groups B and C compared with group A (elective stenting: group A 3 32%; group B 3 66%; group C 3 69%; P < 0.0001), in reference vessel size (group A 3 3.22 3 0.37 mm; group B 3 2.92 3 0.56 mm; group C 3 2.98 3 0.57 mm; P < 0.0001), and for presence of type B2 and C lesions (group A 3 57%; group B 3 72%; group C 3 74%; P < 0.001). The complication rate significantly decreased in group C (group A 3 3.6%; group B 3 4.1%; group C 3 1.2%; P < 0.001) and the mean patient hospital stay decreased to 2 days in groups B and C due to the abolition of the need for anticoagulant treatment. The angiographic restenosis rate increased in groups B and C (group A 3 20%; group B 3 34%; group C 3 32%; P < 0.001). The need for a repeat procedure increased as stenting of more complex lesions and smaller vessels was attempted: target lesion revascularization (TLR) was performed in 16% of patients in group A (73/434), in 18% of group B (35/192) and in 22% of group C (129/588) (P 3 0.04 for A versus C). Major cardiac events (MACE) occurred in 142 patients in group A (33%), 60 patients in group B (31%) and in 181 patients in group C (30%). The evolving technique of coronary stenting has expanded the spectrum of indications and range of coronary vessels attempted, and decreased the complication rates and hospital stay. However, in less-favorable subsets, additional improvements are needed to affect the long-term outcome.

Journal Article↗

Is sirolimus better than paclitaxel? A review of the comparative data on drug-eluting stents.

Drug-eluting stents have been unequivocally demonstrated to reduce in-stent restenosis when compared to bare metal stents, with resultant lower rates of repeat revascularization. Comparative data are now emerging which compare the performance of sirolimus- and paclitaxel-eluting stents to each other rather than to bare metal stents. In this article, we review these data with the aim of placing the studies in context thereby providing an overall view of this rapidly developing field as it stands at present.

Animals↗

Influence of Class I interferons on performance of vascular cells on stent material in vitro.

PURPOSE: Numerous reports suggest that Class 1 interferons (IFNs), particularly IFN-gamma, inhibit migration and proliferation of different types of human cells. The objective of the present study was to determine the effect of Class I IFNs on viability and growth characteristics of human aortic endothelial cells (ECs), smooth muscle cells (SMC) and fibroblasts (FBs) in vitro. METHODS: Stainless-steel (316-l) disks were coated with fibrin meshwork containing IFN-gamma or IFN-alpha. The discs and IFN embedded meshwork were incubated with human EC, SMC and FB, and then cultured, whereas control cells were seeded onto uncoated surfaces or plain fibrin meshwork. Concentrations of recombinant IFN varied from 5 to 20 ng/cm(2). Assessment of effect on cell viability, growth and attachment was performed utilizing Alamar Blue (AB) assay. Cell morphology was assessed by scanning electron microscopy (SEM). RESULTS: We have now shown inhibitory capacity of IFN-gamma on all three types of unstimulated cells. The growth-inhibitory effect was maximal with SMC, while it was minimal with FB and EC. IFN-gamma abrogated mitogenic responses of SMC but not EC and partially FB to VEGF and FGF stimulation. IFN-alpha was able to inhibit EC growth and, to a lesser extent, FB, and did influence growth rates of SMC. Biochemical analysis of lactate dehydrogenase activity suggested that IFN was not toxic to vascular cells. We also measured the expression of cell adhesive molecules: P- and E-selections, PECAM and ICAM-1. These molecules were upregulated by IFN in EC. Media derived from quiescent human SMC displayed low immunoreactive elastase activity, while conditional media after IFN-gamma treatment but not IFN-alpha treatment had approximately a threefold greater activity. CONCLUSION: These data suggest that IFN-gamma significantly inhibits SMC growth in the absence of significant endothelial toxicity and is dose-dependent; however, animal experiments are needed to further explore the antirestenotic effects of IFNs.

Antineoplastic Agents↗

Beta-radiation therapy for long lesions in native coronary vessels: a matched comparison between de novo and in-stent restenotic lesions.

OBJECTIVE: The purpose of this study was to evaluate effectiveness and to compare clinical outcome of intracoronary beta-radiation to treat long lesions (>20 mm) in patients with de novo stenosis vs. patients with in-stent restenosis (ISR). METHODS: A matched comparison of 44 patients with 63 de novo lesions and 48 patients with 63 ISR lesions (>20 mm) treated with intracoronary beta-radiation was performed. RESULTS: Stents were implanted in 65.1% of de novo and 19% of ISR lesions (P=.001). Radiation doses delivered were 17.2+/-3.0 vs. 20.3+/-3.0 Gy at 2 mm from the source center for de novo and ISR lesions. There was no difference in the incidence of in-hospital events. Clinical follow-up at 16.4+/-6.7 months showed no difference in major adverse cardiac events (MACE) between de novo and ISR patients (27.3% vs. 25%, P=.8). Late total occlusions (LTOs) occurred in eight patients (four in each group) treated with stents at the time of radiation and after discontinuation of ticlopidine. By multivariate analysis, stent implantation was the only predictor of late occlusions (OR 8.25, 95% CI 1.73-38.46, P<.008). Restenosis rates were similar for de novo and ISR lesions (29.3% vs. 23.2%, P=.46), as well as target lesion revascularization (TLR) and target vessel revascularization (TVR) rates (22.7% vs. 22.9% and 29.5% vs. 29.2%, respectively). CONCLUSIONS: Intracoronary beta-radiation gives comparable results when used to treat de novo or ISR lesions provided new stent implantation can be avoided. Long-term combined antiplatelet therapy is mandatory for patients who receive new stents at the time of radiation treatment.

Adult↗

Contrast agent--associated nephrotoxicity.

Radiocontrast media can lead to a reversible form of acute renal failure that begins soon after the contrast dye administration and generally is benign. Contrast media accounts for 10% of all causes of hospital-acquired acute renal failure and represents the third leading cause of in-hospital renal function deterioration after decreased renal perfusion and postoperative renal insufficiency. The in-hospital mortality rate in patients developing renal insufficiency is related directly to the magnitude increase of serum creatinine concentration. The mortality rate ranges from 3.8% with an increase in serum creatinine level of 0.5 to 0.9 mg/dL to 64% with an increase of greater than 3.0 mg/dL. The mechanism by which contrast-induced renal failure occurs is not well understood. Contrast agent-associated nephrotoxicity appears to be a result of direct contrast-induced renal tubular epithelial cell toxicity and renal medullary ischemia. Furthermore, a key mechanism seems to be alteration in renal dynamics, probably caused by imbalances between vasodilator and vasoconstrictor factors, including the activities of nitric oxide, prostaglandins, endothelin, and reactive oxygen species. The optimal strategy to prevent contrast-associated nephrotoxicity remains uncertain. At present, recommendations are as follows: (1) periprocedural hydration, (2) use of a low-osmolality contrast, and (3) limiting the amount of contrast agent. Recently, considerable interest has resulted from the preliminary positive data on the effectiveness of prophylactic administration of acetylcysteine and fenoldopam. The former may prevent the direct oxidative tissue damage, whereas the latter is a selective intrarenal vasodilator.

Acetylcysteine↗