Search PubMed⌕ Search

Biomedical subjects

Antje J Baeumner

Publications and source records attributed to Antje J Baeumner.

At least 19 recordsLinked to original sources

Application of ganglioside-sensitized liposomes in a flow injection immunoanalytical system for the determination of cholera toxin.

Cholera, an acute infectious disease associated with water and seafood contamination, is caused by the bacterium Vibrio cholerae, which lives and colonizes in the small intestine and secretes cholera toxin (CT), a causative agent for diarrhea in humans. Based on earlier lateral flow assays, a flow injection liposome immunoanalysis (FILIA) system with excellent sensitivity was developed in this study for the determination of CT at zeptomole levels. Ganglioside (GM1), found to have specific affinity toward CT, was inserted into the phospholipid bilayer during the liposome synthesis. These GM1-sensitized, sulforhodamine B (SRB) dye-entrapping liposomes were used as probes in the FILIA system. Anti-CT antibodies were immobilized in its microcapillary. CT was detected by the formation of a sandwich complex between the immobilized antibody and GM1 liposomes. During the assay, the sample was introduced first into the column, and then liposomes were injected to bind to all CT captured by the antibody in the microcapillary. Subsequently, the SRB dye molecules were released from the bound liposomes via the addition of the detergent octyl glucopyranoside. The released dye molecules were transported to a flow-through fluorescence detector for quantification. The FILIA system was optimized with respect to flow rate, antibody concentration, liposome concentration, and injected sample volume. The calibration curve for CT had a linear range of 10-16 to 10-14 g mL-1. The detection limit of this immunosensor was 6.6 x 10(-17) g mL-1 in 200-microL samples (equivalent to 13 ag or 1.1 zmol).

Antibodies↗

Application of a unique server-based oligonucleotide probe selection tool toward a novel biosensor for the detection of Streptococcus pyogenes.

We developed a software program for the rapid selection of detection probes to be used in nucleic acid-based assays. In comparison to commercially available software packages, our program allows the addition of oligotags as required by nucleic acid sequence-based amplification (NASBA) as well as automatic BLAST searches for all probe/primer pairs. We then demonstrated the usefulness of the program by designing a novel lateral flow biosensor for Streptococcus pyogenes that does not rely on amplification methods such as the polymerase chain reaction (PCR) or NASBA to obtain low limits of detection, but instead uses multiple reporter and capture probes per target sequence and an instantaneous amplification via dye-encapsulating liposomes. These assays will decrease the detection time to just a 20 min hybridization reaction and avoid costly enzymatic gene amplification reactions. The lateral flow assay was developed quantifying the 16S rRNA from S. pyogenes by designing reporter and capture probes that specifically hybridize with the RNA and form a sandwich. DNA reporter probes were tagged with dye-encapsulating liposomes, biotinylated DNA oligonucleotides were used as capture probes. From the initial number of capture and reporter probes chosen, a combination of two capture and three reporter probes were found to provide optimal signal generation and significant enhancement over single capture/reporter probe combinations. The selectivity of the biosensor was proven by analyzing organisms closely related to S. pyogenes, such as other Streptococcus and Enterococcus species. All probes had been selected by the software program within minutes and no iterative optimization and re-design of the oligonucleotides was required which enabled a very rapid biosensor prototyping. While the sensitivity obtained with the biosensor was only 135 ng, future experiments will decrease this significantly by the addition of more reporter and capture probes for either the same rRNA or a different nucleic acid target molecule. This will lead to the possibility of detecting S. pyogenes with a rugged assay that does not require a cell culturing or gene amplification step and will therefore enable rapid, specific and sensitive onsite testing.

Biosensing Techniques↗

Optimization of DNA-tagged liposomes for use in microtiter plate analyses.

Dye-encapsulating unilamellar DNA oligonucleotide-tagged liposomes were prepared and characterized for use as signal-enhancing reagents in a microtiter plate sandwich-hybridization analyses of single-stranded RNA or DNA sequences. The liposomes were synthesized using the reversed-phase evaporation method and tagged with DNA oligonucleotides by adding cholesteryl-modified DNA reporter probes to the initial lipid mixture. Liposomes were prepared using probe coverages of 0.0013-0.103 mol% of the total lipid input, several hydrophobic and poly(ethylene glycol)-based spacers between the cholesteryl anchor and the probe, and liposome diameters ranging from 200 nm to 335 nm. Their signal enhancement functionality was compared by using them in microtiter plate sandwich-hybridization assays for the detection of single-stranded DNA sequences. In these assays, an optimal reporter probe concentration of 0.103 mol%, a liposome diameter of 274 nm, and a phospholipid concentration of 0.3 mM were found. The length between the cholesteryl anchor and the probe was optimal when a spacer composed of TEG+(CH2O)3 was used. Under optimal conditions, a detection limit of 0.5 nM for a truncated synthetic DNA sequence was found with a coefficient of variation of 4.4%. A 500-fold lower limit of detection using fluorescence was found using lysed dye-encapsulating liposomes versus a single fluorescein-labeled probe. Finally, when this method was applied to the detection of atxA RNA extracted from E.coli SG12036-pIu121 and amplified using NASBA, a minimum extracted concentration of RNA of 1.1x10(-7) microg/microL was found.

DNA↗

Optimization of DNA-tagged dye-encapsulating liposomes for lateral-flow assays based on sandwich hybridization.

A novel protocol for the synthesis of dye-encapsulating liposomes tagged with DNA oligonucleotides at their outer surface was developed. These liposomes were optimized for use as signal enhancement agents in lateral-flow sandwich-hybridization assays for the detection of single-stranded RNA and DNA sequences. Liposomes were synthesized using the reverse-phase evaporation method and tagged with oligonucleotides by adding cholesteryl-modified DNA probes to the initial lipid mixture. This resulted in a greatly simplified protocol that provided excellent control of the probe coverage on the liposomes and cut the preparation time from 16 hours to just 6 hours. Liposomes were prepared using probe concentrations ranging from 0.00077 to 0.152 mol% of the total lipid, several hydrophobic and polyethylene glycol-based spacers between the cholesteryl anchor and the probe, and liposome diameters ranging from 208 nm to 365 nm. The liposomes were characterized by dynamic light scattering, visible spectroscopy, and fluorescence spectroscopy. Their signal enhancement functionality was compared by using them in lateral-flow optical biosensors for the detection of single-stranded DNA sequences. In these assays, an optimal reporter probe concentration of 0.013 mol%, liposome diameter of 315 nm, and liposome optical density of 0.4-0.6 at 532 nm were found. The spacer length between the cholesteryl anchor and the probe showed no significant effect on the signals in the lateral-flow assays. The results presented here provide important data for the general use of liposomes as labels in analytical assays, with specific emphasis on nucleic acid detection via lateral flow assays.

Biosensing Techniques↗

Sequential injection analysis system for the sandwich hybridization-based detection of nucleic acids.

A sequential injection analysis lab-on-valve (SIA-LOV) system was developed for the specific detection of single-stranded nucleic acid sequences via sandwich hybridization of specific DNA probes to the target sequence. One DNA probe was tagged with fluorescein; the other was biotinylated and immobilized to streptavidin-coated porous beads. The system was optimized with respect to buffer composition, length of hybridization and wash steps, and volumes and concentrations of components used. On-bead oligonucleotide hybridization was studied using UV detection at 260 nm, while a final dose response curve was quantified using fluorescence detection. A dynamic range of 1-1000 pmol was obtained for a synthetic DNA sequence that was homologous to a segment in the B. anthracis atxA mRNA. A within-day variation of 7.2% and a day-to-day variation of 9.9% was observed. Each analysis was completed within 20 min. Subsequently, the system was applied to the detection of atxA mRNA expressed in a surrogate organism and amplified using NASBA. The SIA-LOV will find its application in routine laboratory-based analysis of specific single-stranded DNA/RNA sequences. Future improvements will include the integration of dye-encapsulating liposomes for signal enhancement used in lieu of the single fluorophore-labeled probe in order to lower the limit of detection.

Biosensing Techniques↗

Electrochemical microfluidic biosensor for the detection of nucleic acid sequences.

A microfluidic biosensor with electrochemical detection for the quantification of nucleic acid sequences was developed. In contrast to most microbiosensors that are based on fluorescence for signal generation, it takes advantage of the simplicity and high sensitivity provided by an amperometric and coulorimetric detection system. An interdigitated ultramicroelectrode array (IDUA) was fabricated in a glass chip and integrated directly with microchannels made of poly(dimethylsiloxane) (PDMS). The assembly was packaged into a Plexiglas housing providing fluid and electrical connections. IDUAs were characterized amperometrically and using cyclic voltammetry with respect to static and dynamic responses for the presence of a reversible redox couple-potassium hexacyanoferrate (ii)/hexacyanoferrate (iii) (ferri/ferrocyanide). A combined concentration of 0.5 microM of ferro/ferricyanide was determined as lower limit of detection with a dynamic range of 5 orders of magnitude. Background signals were negligible and the IDUA responded in a highly reversible manner to the injection of various volumes and various concentrations of the electrochemical marker. For the detection of nucleic acid sequences, liposomes entrapping the electrochemical marker were tagged with a DNA probe, and superparamagnetic beads were coated with a second DNA probe. A single stranded DNA target sequence hybridized with both probes. The sandwich was captured in the microfluidic channel just upstream of the IDUA via a magnet located in the outside housing. Liposomes were lysed using a detergent and the amount of released ferro/ferricyanide was quantified while passing by the IDUA. Optimal location of the magnet with respect to the IDUA was investigated, the effect of dextran sulfate on the hybridization reaction was studied and the amount of magnetic beads used in the assay was optimized. A dose response curve using varying concentrations of target DNA molecules was carried out demonstrating a limit of detection at 1 fmol assay(-1) and a dynamic range between 1 and 50 fmol. The overall assay took 6 min to complete, plus 15-20 min of pre-incubation and required only a simple potentiostat for signal recording and interpretation.

Biosensing Techniques↗

Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat.

An electrochemical microfluidic biosensor with an integrated minipotentiostat for the quantification of RNA was developed based on nucleic acid hybridization and liposome signal amplification. Specificity of the biosensor was ensured by short DNA probes that hybridize with the target RNA or DNA sequence. The reporter probe was coupled to liposomes entrapping the electrochemically active redox couple potassium ferri/ferrohexacyanide. The capture probes were coupled to superparamagnetic beads that were isolated on a magnet in the biosensor. Upon capture, the liposomes were lysed to release the electrochemical markers that were detected on an interdigitated ultramicroelectrode array in the biosensor just downstream of the magnet. The current was measured, stored and displayed by miniaturized instrumentation (miniEC). The accuracy of the miniEC was evaluated by comparing its performance to a standard bench-top electrochemical workstation in static and dynamic DC amperometric experiments. In both sets of experiments, the inexpensive miniEC performance was comparable in signal strength to that of the electrochemical workstation. In fact, the miniEC achieved a detection limit of 0.01 microM combined ferri/ferrohexacyanide concentration which was 10 x lower than that of the standard lab-bench system. The response time of the miniEC system was the same for low concentrations taking about 10 s to steady state. It was, however, slower at higher concentrations, taking 5 s versus only 1 s for the bench-top system. Finally, the functionality of the miniEC was successfully demonstrated with the detection of Dengue virus RNA.

Biosensing Techniques↗

Recirculating, passive micromixer with a novel sawtooth structure.

A microfluidic device capable of recirculating nano to microlitre volumes in order to efficiently mix solutions is described. The device consists of molded polydimethyl siloxane (PDMS) channels with pressure inlet and outlet holes sealed by a glass lid. Recirculation is accomplished by a repeatedly reciprocated flow over an iterated sawtooth structure. The sawtooth structure serves to change the fluid velocity of individual streamlines differently depending on whether the fluid is flowing backwards or forward over the structure. Thus, individual streamlines can be accelerated or decelerated relative to the other streamlines to allow sections of the fluid to interact that would normally be linearly separated. Low Reynolds numbers imply that the process is reversible, neglecting diffusion. Computer simulations were carried out using FLUENT. Subsequently, fluorescent indicators were employed to experimentally verify these numerical simulations of the recirculation principal. Finally, mixing of a carboxyfluorescein labeled DMSO plug with an unlabeled DMSO plug across an immiscible hydrocarbon plug was investigated. At cycling rates of 1 Hz across five sawtooth units, the time was recorded to reach steady state in the channels, i.e. until both DMSO plugs had the same fluorescence intensity. In the case of the sawtooth structures, steady state was reached five times faster than in channels without sawtooth structures, which verified what would be expected based on numerical simulations. The microfluidic mixer is unique due to its versatility with respect to scaling, its potential to also mix solutions containing small particles such as beads and cells, and its ease of fabrication and use.

Computer Simulation↗

Microfluidic biosensor for the serotype-specific detection of dengue virus RNA.

The development of a microfluidic biosensor with fluorescence detection for the rapid, sensitive, and serotype-specific detection of Dengue virus is presented. The biosensor chip consists of poly(dimethylsiloxane) (PDMS) substrate with fabricated microchannels and a glass substrate used to seal the microchannels. These two substrates are packaged within a pressure-closed Plexiglas housing to provide a watertight reversible sealing at the PDMS-glass interface. The ability to reversibly seal the device permits easy disassembly and quick interchange of the device parts, which is ideal for developmental purposes. The biosensor employs a magnetic bead-based sandwich hybridization system in conjugation with liposome amplification for the specific detection of nucleic acids. The concentrations of the various biosensor components were optimized using a synthesized fragment of Dengue virus RNA. To evaluate the sensitivity of the assay, two detection systems, based on fluorescence measurements of intact and lysed liposomes, were analyzed. The entire analysis was complete within 20 min (including incubation time) with RNA detection limits of 0.125 nM and 50 pM for intact and lysed liposome detection systems, respectively. Subsequently, the biosensor was applied to the analysis of actual RNA obtained from Dengue virus serotypes 1-4. The resulting signals were compared to those obtained using standard electrochemiluminescence detection and shown to correspond perfectly with respect to serotype identification.

Base Sequence↗

Bacillus anthracis: toxicology, epidemiology and current rapid-detection methods.

B. anthracis, the causative agent for anthrax, has been well studied for over 150 years. Due to the genetic similarities among various Bacillus species, as well as its existence in both a spore form and a vegetative state, the detection and specific identification of B. anthracis have been proven to require complex techniques and/or laborious methods. With the heightened interest in the organism as a potential biological threat agent, a large number of interesting detection technologies have recently been developed, including methods involving immunological and nucleic acid-based assay formats. The technologies range from culture-based methods to portable Total Analysis Systems based on real-time PCR. This review with 170 references provides a brief background on the toxicology and epidemiology of B. anthracis, discusses challenges associated with its detection related to genetic similarities to other species, and reviews immunological and, with greater emphasis, nucleic acid-based detection systems.

Animals↗

Development of a microfluidic biosensor module for pathogen detection.

The development of a microfluidic biosensor module with fluorescence detection for the identification of pathogenic organisms and viruses is presented in this article. The microfluidic biosensor consists of a network of microchannels fabricated in polydimethylsiloxane (PDMS) substrate. The microchannels are sealed with a glass substrate and packed in a Plexiglas housing to provide connection to the macro-world and ensure leakage-free flow operation. Reversible sealing permits easy disassembly for cleaning and replacing the microfluidic channels. The fluidic flow is generated by an applied positive pressure gradient, and the module can be operated under continuous solution flow of up to 80 microL min(-1). The biosensor recognition principle is based on DNA/RNA hybridization and liposome signal amplification. Superparamagnetic beads are incorporated into the system as a mobile solid support and are an essential part of the analysis scheme. In this study, the design, fabrication and the optimization of concentrations and amounts of the different biosensor components are carried out. The total time required for an assay is only 15 min including sample incubation time. The biosensor module is designed so that it can be easily integrated with a micro total analysis system, which will combine sample preparation and detection steps onto a single chip.

Bacteria↗

A rapid biosensor for viable B. anthracis spores.

A simple membrane-strip-based biosensor assay has been combined with a nucleic acid sequence-based amplification (NASBA) reaction for rapid (4 h) detection of a small number (ten) of viable B. anthracis spores. The biosensor is based on identification of a unique mRNA sequence from one of the anthrax toxin genes, the protective antigen ( pag), encoded on the toxin plasmid, pXO1, and thus provides high specificity toward B. anthracis. Previously, the anthrax toxins activator ( atxA) mRNA had been used in our laboratory for the development of a biosensor for the detection of a single B. anthracis spore within 12 h. Changing the target sequence to the pag mRNA provided the ability to shorten the overall assay time significantly. The vaccine strain of B. anthracis (Sterne strain) was used in all experiments. A 500-microL sample containing as few as ten spores was mixed with 500 microL growth medium and incubated for 30 min for spore germination and mRNA production. Thus, only spores that are viable were detected. Subsequently, RNA was extracted from lysed cells, selectively amplified using NASBA, and rapidly identified by the biosensor. While the biosensor assay requires only 15 min assay time, the overall process takes 4 h for detection of ten viable B. anthracis spores, and is shortened significantly if more spores are present. The biosensor is based on an oligonucleotide sandwich-hybridization assay format. It uses a membrane flow-through system with an immobilized DNA probe that hybridizes with the target sequence. Signal amplification is provided when the target sequence hybridizes to a second DNA probe that has been coupled to liposomes encapsulating the dye sulforhodamine B. The amount of liposomes captured in the detection zone can be read visually or quantified with a hand-held reflectometer. The biosensor can detect as little as 1 fmol target mRNA (1 nmol L(-1)). Specificity analysis revealed no cross-reactivity with 11 organisms tested, among them closely related species such as B. cereus, B. megaterium, B. subtilis, B. thuringiensis, Lactococcus lactis, Lactobacillus plantarum, and Chlostridium butyricum. Also, no false positive signals were obtained from nonviable spores. We suggest that this inexpensive biosensor is a viable option for rapid, on-site analysis providing highly specific data on the presence of viable B. anthracis spores.

Bacillus anthracis↗

Multi-analyte single-membrane biosensor for the serotype-specific detection of Dengue virus.

A multi-analyte biosensor based on nucleic acid hybridization and liposome signal amplification was developed for the rapid serotype-specific detection of Dengue virus. After RNA amplification, detection of Dengue virus specific serotypes can be accomplished using a single analysis within 25 min. The multi-analyte biosensor is based on single-analyte assays (see Baeumner et al (2002) Anal Chem 74:1442-1448) developed earlier in which four analyses were required for specific serotype identification of Dengue virus samples. The multi-analyte biosensor employs generic and serotype-specific DNA probes, which hybridize with Dengue RNA that is amplified by the isothermal nucleic acid sequence based amplification (NASBA) reaction. The generic probe (reporter probe) is coupled to dye-entrapping liposomes and can hybridize to all four Dengue serotypes, while the serotype-specific probes (capture probes) are immobilized through biotin-streptavidin interaction on the surface of a polyethersulfone membrane strip in separate locations. A mixture of amplified Dengue virus RNA sequences and liposomes is applied to the membrane and allowed to migrate up along the test strip. After the liposome-target sequence complexes hybridize to the specific probes immobilized in the capture zones of the membrane strip, the Dengue serotype present in the sample can be determined. The amount of liposomes immobilized in the various capture zones directly correlates to the amount of viral RNA in the sample and can be quantified by a portable reflectometer. The specific arrangement of the capture zones and the use of unlabeled oligonucleotides (cold probes) enabled us to dramatically reduce the cross-reactivity of Dengue virus serotypes. Therefore, a single biosensor can be used to detect the exact Dengue serotype present in the sample. In addition, the biosensor can simultaneously detect two serotypes and so it is useful for the identification of possible concurrent infections found in clinical samples. The various biosensor components have been optimized with respect to specificity and sensitivity, and the system has been ultimately tested using blind coded samples. The biosensor demonstrated 92% reliability in Dengue serotype determination. Following isothermal amplification of the target sequences, the biosensor had a detection limit of 50 RNA molecules for serotype 2, 500 RNA molecules for serotypes 3 and 4, and 50,000 molecules for serotype 1. The multi-analyte biosensor is portable, inexpensive, and very easy to use and represents an alternative to current detection methods coupled with nucleic acid amplification reactions such as electrochemiluminescence, or those based on more expensive and time consuming methods such as ELISA or tissue culture.

Biosensing Techniques↗

A universal nucleic acid sequence biosensor with nanomolar detection limits.

A quantitative universal biosensor was developed on the basis of olignucleotide sandwich hybridization for the rapid (30 min total assay time) and highly sensitive (1 nM) detection of specific nucleic acid sequences. The biosensor consists of a universal membrane and a universal dye-entrapping liposomal nanovesicle. Two oligonucleotides, a reporter and a capture probe that can hybridize specifically with the target nucleic acid sequence, can be coupled to the universal biosensor components within a 10-min incubation period, thus converting it into a specific assay. The liposomal nanovesicles bear a generic oligonucleotide sequence on their outer surface. The reporter probes consist of two parts: the 3' end is complementary to the generic liposomal oligonucleotide, and the 5' end is complementary to the target sequence. Streptavidin is immobilized in the detection zone of the universal membranes. The capture probes are biotinylated at the 5' end and are complementary to another segment in the target sequence. Thus, by incubating the liposomal nanovesicles with the reporter probes, the target sequence, and the capture probes in a hybridization buffer for 20 min, a sandwich complex is formed. The mixture is applied to the membrane, migrates along the strip, and is captured in the detection zone via streptavidin-biotin binding. The biosensor assay was optimized with respect to hybridization conditions, concentrations of all components, and length of the generic probe. It was tested using synthetic DNA sequences and authentic RNA sequences isolated and amplified using nucleic acid sequence-based amplification (NASBA) from Escherichia coli, Bacillus anthracis, and Cryptosporidium parvum. Dose-response curves were carried out using a portable reflectometer for the instantaneous quantification of liposomal nanovesicles in the detection zone. Limits of detection of 1 fmol per assay (1 nM) and dynamic ranges between 1 fmol and at least 750 fmol (1-750 nM) were obtained. The universal biosensors were compared to specific RNA biosensors developed earlier and were found to match or exceed their performance characteristics. In addition, no changes to hybridization conditions were required when switching to the detection of a new target sequence or when using actual nucleic acid sequence-based amplified RNA sequences. Therefore, the universal biosensor described is an excellent tool for use in laboratories or at test sites for rapidly investigating and quantifying any nucleic acid sequence of interest.

Animals↗

A generic sandwich-type biosensor with nanomolar detection limits.

A quantitative and highly sensitive, yet simple and rapid, biosensor system was developed for the detection of nucleic acid sequences that can also be adapted to the detection of antigens. A dipstick-type biosensor with liposome amplification, based on a sandwich assay format with optical detection, was combined with a simple coupling reaction that allows the transformation of the generic biosensor components to target specific ones by a mere incubation step. This biosensor platform system was developed and optimized, and its principle was proven using DNA oligonucleotides that provided a nucleic acid biosensor for the specific detection of RNA and DNA sequences. However, the coupling reaction principle chosen can also be used for the immobilization of antibodies or receptor molecules, and therefore for the development of immunosensors and receptor-based biosensors. The generic biosensor consists of liposomes entrapping sulforhodamine B that are coated with streptavidin on the outside, and polyethersulfone membranes with anti-fluorescein antibodies immobilized in the detection zone. In order to transform the generic biosensor into a specific DNA/RNA biosensor, two oligonucleotides that are able to hybridize to the target sequence were labeled with a biotin and a fluorescein molecule, respectively. By simultaneously incubating the liposomes, both oligonucleotides, and the target sequence in a hybridization buffer for 20-30 min at 42 degrees C, a sandwich complex was formed. The mixture was applied to the polyethersulfone membrane. The complex was captured in the detection zone and quantified using a hand-held reflectometer. The system was tested using RNA sequences from B. anthracis, C. parvum and E. coli. Quantitation of concentrations between 10 fmol and 1000 fmol (10-1000 nM) was possible without altering any biosensor assay conditions. In addition, no changes to hybridization conditions were required when using authentic nucleic acid sequence-based amplified RNA sequences, and the generic biosensor compared favorably with those previously developed specifically for the RNA sequences. Therefore, the universal biosensor described is an excellent tool, for use in laboratories or at test sites, for rapidly investigating and quantifying any nucleic acid sequence of interest, as well as potentially any antigen of interest that can be bound by two antibodies simultaneously.

Animals↗

Biosensors for environmental pollutants and food contaminants.

This review article provides an overview of the most recent literature on biosensors for environmental pollutants and food contaminants. Due to the large number of publications, only papers published between 2000 and January 2003 were considered. Also, while not all of the published literature could be reviewed here, over 200 references are cited to provide a good overview of research undertaken in the last two years. Older publications are covered by a number of earlier review articles. This article provides an introduction into the field including specific consideration of the application areas, describes the typical biosensor assay format used, and is subsequently structured according to the biorecognition elements used (i.e., nucleic acids, enzymes, whole cells, tissue and whole organisms, antibodies and receptors, and biomimetic materials). In addition, a section on microbiosensing systems is provided. Since only very few microbiosensors with applications in environmental and food systems have been published, enabling technology is also covered in this article.

Biosensing Techniques↗

Ganglioside-liposome immunoassay for the ultrasensitive detection of cholera toxin.

An extremely sensitive bioassay has been developed for cholera toxin (CT) detection, using ganglioside-incorporated liposomes. Cholera is a diarrheal disease, often associated with water or seafood contamination. Ganglioside GM1 was used to prepare the liposomes by spontaneous insertion into the phospholipid bilayer. CT recognition and signal generation is based on the strong and specific interaction between GM1 and CT. In a sandwich immunoassay, CT was detected as a colored band on the nitrocellulose membrane strip, where CT bound to GM1-liposomes can be captured by immobilized antibodies. The intensity of the band could be visually estimated or measured by densitometry, using computer software. The limit of detection (LOD) of CT in the assay system was found to be 10 fg/mL which is equivalent to 8 zmol in the 70-microL sample. The assay was also tested with water samples spiked with CT, providing a LOD of 0.1-30 pg/mL, which is much better than previously reported limits of detection from other assays. The assay could be completed within 20 min. These results demonstrate that the bioassay developed for CT is rapid and ultrasensitive, suggesting the possibility for detecting CT, simply and reliably, in field screening.

Antibodies↗

Biosensor for the specific detection of a single viable B. anthracis spore.

A simple membrane strip-based biosensor for the detection of viable B. anthracis spores was developed and combined with a spore germination procedure as well as a nucleic acid amplification reaction to identify as little as one viable B. anthracis spore in less than 12 h. The biosensor is based on identification of a unique mRNA sequence from the anthrax toxin activator (atxA) gene encoded on the toxin plasmid, pXO1. Preliminary work relied on plasmid vectors in both E. coli and B. thuringiensis expressing the atxA gene. Once the principle was firmly established, the vaccine strain of B. anthracis was used. After inducing germination and outgrowth of spores of B. anthracis (Sterne strain), RNA was extracted from lysed cells, amplified using nucleic acid sequence-based amplification (NASBA), and rapidly identified by the biosensor. While the biosensor assay requires only 15-min assay time, the overall process takes 12 h for the detection of as little as one viable B. anthracis spore, and is shortened significantly, if larger amounts of spores are present. The biosensor is based on an oligonucleotide sandwich-hybridization assay format. It uses a membrane flow-through system with an immobilized oligonucleotide probe that hybridizes with the target sequence. Signal amplification is provided when the target sequence hybridizes to a second oligonucleotide probe that has been coupled to dye-encapsulating liposomes. The dye in the liposomes then provides a signal that can be read visually or quantified with a hand-held reflectometer. The biosensor can detect as little as 1.5 fmol of target mRNA. Specificity analysis revealed no crossreactivity with closely related species such as B. cereus, B. megaterium, B. subtilis, B. thuringiensis etc.

Bacillus anthracis↗