APDS: the autonomous pathogen detection system.

We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system was developed to provide early warning to civilians in the event of a bioterrorism incident and can be used at high profile events for short-term, intensive monitoring or in major public buildings or transportation nodes for long-term monitoring. The APDS is completely automated, offering continuous aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and nucleic acid-based polymerase chain reaction (PCR) amplification and detection. Highly multiplexed antibody-based and duplex nucleic acid-based assays are combined to reduce false positives to a very low level, lower reagent costs, and significantly expand the detection capabilities of this biosensor. This article provides an overview of the current design and operation of the APDS. Certain sub-components of the ADPS are described in detail, including the aerosol collector, the automated sample preparation module that performs multiplexed immunoassays with confirmatory PCR, and the data monitoring and communications system. Data obtained from an APDS that operated continuously for 7 days in a major U.S. transportation hub is reported.

Aerosols↗

Autonomous detection of aerosolized biological agents by multiplexed immunoassay with polymerase chain reaction confirmation.

The autonomous pathogen detection system (APDS) is an automated, podium-sized instrument that continuously monitors the air for biological threat agents (bacteria, viruses, and toxins). The system has been developed to warn of a biological attack in critical or high-traffic facilities and at special events. The APDS performs continuous aerosol collection, sample preparation, and detection using multiplexed immunoassay followed by confirmatory PCR using real-time TaqMan assays. We have integrated completely reusable flow-through devices that perform DNA extraction and PCR amplification. The fully integrated system was challenged with aerosolized Bacillus anthracis, Yersinia pestis, Bacillus globigii, and botulinum toxoid. By coupling highly selective antibody- and DNA-based assays, the probability of an APDS reporting a false positive is extremely low.

Aerosols↗

Development of an automated sample preparation module for environmental monitoring of biowarfare agents.

An automated sample preparation module, based upon sequential injection analysis (SIA), has been developed for use within an autonomous pathogen detection system. The SIA system interfaced aerosol sampling with multiplexed microsphere immunoassay-flow cytometric detection. Metering and sequestering of microspheres using SIA was found to be reproducible and reliable, over 24-h periods of autonomous operation. Four inbuilt immunoassay controls showed excellent immunoassay and system stability over five days of unattended continuous operation. Titration curves for two biological warfare agents, Bacillus anthracis and Yersinia pestis, obtained using the automated SIA procedure were shown to be similar to those generated using a manual microtiter plate procedure.

Antibodies, Bacterial↗

Autonomous detection of aerosolized Bacillus anthracis and Yersinia pestis.

We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system is designed to provide early warning to civilians in the event of a terrorist attack. The final APDS will be completely automated, offering aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and orthogonal, multiplexed PCR (nucleic acid) amplification and detection. The system performance (current capabilities include aerosol collection, multiplexed immunoassays, sample archiving, data reporting, and alarming) was evaluated in a field test conducted in a Biosafety Level 3 facility, where the system was challenged with, and detected, a series of aerosolized releases containing two live, virulent biological threat agents (Bacillus anthracis and Yersinia pestis). Results presented here represent the first autonomous, simultaneous measurement of these agents.

Aerosols↗

The effect of pulmonary circulation hemodynamics on right ventricular unloading via the bidirectional Glenn shunt: implications for congenitally corrected transposition repair.

The bidirectional Glenn shunt has been successfully applied as an adjunct to ventricular septal defect closure and pulmonary valvulotomy to treat congenitally corrected transposition of the great arteries (ccTGA). The purpose of this study was to examine the volume and pressure unloading effects of the bidirectional Glenn shunt on the hypertrophied pulmonary ventricle in a canine model of ccTGA. Five beagles underwent survival surgery to band the pulmonary artery. Three months later, a polytetrafluoroethylene graft was anastomosed to the superior vena cava and right pulmonary artery. The graft or superior vena cava was clamped to create the normal or bidirectional Glenn circulation, and hemodynamic data were recorded. The bidirectional Glenn shunt significantly reduced right ventricular volume loading and stroke work. Dogs with normal pre-bidirectional Glenn cardiac outputs had greatly reduced right ventricular volumes and pressures with the bidirectional Glenn shunt. Dogs with pre-bidirectional Glenn right ventricular dysfunction had moderate volume but no pressure decreases with the bidirectional Glenn shunt owing to improved left ventricular output. In these dogs it is likely that the decreased level of pressure and volume unloading is because of a concomitant improvement in left ventricular output post-bidirectional Glenn shunt placement. The bidirectional Glenn shunt is effective at unloading the right ventricle in a canine model of ccTGA.

Animals↗