Search PubMed⌕ Search

Biomedical subjects

Annelise E Barron

Publications and source records attributed to Annelise E Barron.

At least 19 recordsLinked to original sources

Optical monitoring of bubble size and shape in a pulsating bubble surfactometer.

The pulsating bubble surfactometer (PBS) is often used for in vitro characterization of exogenous lung surfactant replacements and lung surfactant components. However, the commercially available PBS is not able to dynamically track bubble size and shape. The PBS therefore does not account for bubble growth or elliptical bubble shape that frequently occur during device use. More importantly, the oscillatory volume changes of the pulsating bubble are different than those assumed by the software of the commercial unit. This leads to errors in both surface area and surface tension measurements. We have modified a commercial PBS through the addition of an image-acquisition system, allowing real-time determination of bubble size and shape and hence the accurate tracking of surface area and surface tension. Compression-expansion loops obtained with the commercially available PBS software were compared with those provided by the image-analysis system for dipalmitoylphosphatidylcholine, Infasurf, and Tanaka lipids (dipalmitoylphosphatidylcholine-palmitoyloleoylphosphatidyl-glycerol-palmitic acid, 68:22:9) at concentrations of 0.1 and 1.0 mg/ml and at frequencies of 1 and 20 cycles/min. Whereas minimum surface tension as determined by the image-analysis system is similar to that measured by the commercially available software, the maximum surface tension and the shapes of the interfacial area-surface tension loops are quite different. Differences are attributable to bubble drift, nonsinusoidal volume changes, and variable volume excursions seen with the modified system but neglected by the original system. Image analysis reveals that the extent of loop hysteresis is greatly overestimated by the commercial device and that an apparent, rapid increase in surface tension upon film expansion seen in PBS loops is not observed with the image-analysis system. The modified PBS system reveals new dynamic characteristics of lung surfactant preparations that have not previously been reported.

Equipment Design↗

Poly(acrylamide-co-alkylacrylamides) for electrophoretic DNA purification in microchannels.

We have created a family of water-soluble block copolymers of acrylamide and N-alkylacrylamides that are designed to selectively remove proteins from DNA via microchannel electrophoresis. It was hypothesized that the inclusion of hydrophobic subunits in the polymer chain, in sufficient concentration, could lead to protein adsorption due to hydrophobic interactions. A series ofN-alkylacrylamide comonomers with varying alkyl chain lengths (C4, C6, C8) and also an N,N-dialkyl group (C6-C6) were synthesized via reactions between acryloyl chloride and the respective alkylamines. Copolymers were synthesized using an aqueous "micellar" polymerization technique, which involves dissolving acrylamide in the aqueous phase while hydrophobic monomers are solubilized in sodium dodecyl sulfate micelles. Copolymers comprising up to 4 mol % of a hydrophobic subunit (as verified by (1)H NMR) were synthesized. Polymer molecular weights were determined by tandem gel permeation chromatography-multiangle laser light scattering, and ranged from 1.5 x 10(6) to 4.3 x 10(6). Capillary electrophoresis analysis of bovine serum albumin and beta-lactoglobulin migration in these matrixes revealed that the octylacrylamide and dihexylacrylamide copolymers show the most significant extent of protein adsorption while butylacrylamides show no noteworthy adsorption trend. All copolymer matrixes studied allowed the passage of a dsDNA digest, and displayed some DNA sieving ability at 0.5% (w/w) in TTE (50 mM Tris, 50 mM TAPS, 2 mM EDTA, pH 8.4) buffer. These matrixes are demonstrated in on-chip experiments to adsorb protein, in a step toward meeting the front-end processing goals of mu-TAS for genetic analysis applications.

Acrylamides↗

Protein polymer drag-tags for DNA separations by end-labeled free-solution electrophoresis.

We demonstrate the feasibility of end-labeled free-solution electrophoresis (ELFSE) separation of DNA using genetically engineered protein polymers as drag-tags. Protein polymers are promising candidates for ELFSE drag-tags because their sequences and lengths are controllable not only to generate monodisperse polymers with high frictional drag, but also to meet other drag-tag requirements for high-resolution separations by microchannel electrophoresis. A series of repetitive polypeptides was designed, expressed in Escherichia coli, and purified. By performing an end-on conjugation of the protein polymers to a fluorescently labeled DNA oligomer (22 bases) and analyzing the electrophoretic mobilities of the conjugate molecules by free-solution capillary electrophoresis (CE), effects of the size and charge of the protein polymer drag-tags were investigated. In addition, the electrophoretic behavior of bioconjugates comprising relatively long DNA fragments (108 and 208 bases) and attached to uncharged drag-tags was observed, by conjugating fluorescently labeled polymerase chain reaction (PCR) products to charge-neutral protein polymers, and analyzing via CE. We calculated the amount of friction generated by the various drag-tags, and estimated the potential read-lengths that could be obtained if these drag-tags were used for DNA sequencing in our current system. The results of these studies indicate that larger and uncharged drag-tags will have the best DNA-resolving capability for ELFSE separations, and that theoretically, up to 233 DNA bases could be sequenced using one of the protein polymer drag-tags we produced, which is electrostatically neutral with a chain length of 337 amino acids. We also show that denatured (unfolded) polypeptide chains impose much greater frictional drag per unit molecular weight than folded proteins, such as streptavidin, which has been used as a drag-tag before.

DNA↗

End-labeled free-solution electrophoresis of DNA.

DNA is a free-draining polymer. This subtle but "unfortunate" property of highly charged polyelectrolytes makes it impossible to separate nucleic acids by free-flow electrophoresis. This is why one must typically use a sieving matrix, such as a gel or an entangled polymer solution, in order to obtain some electrophoretic size separation. An alternative approach consists of breaking the charge to friction balance of free-draining DNA molecules. This can be achieved by labeling the DNA with a large, uncharged molecule (essentially a hydrodynamic parachute, which we also call a drag-tag) prior to electrophoresis; the resulting methodology is called end-labeled free-solution electrophoresis (ELFSE). In this article, we review the development of ELFSE over the last decade. In particular, we examine the theoretical concepts used to predict the ultimate performance of ELFSE for single-stranded (ssDNA) sequencing, the experimental results showing that ELFSE can indeed overcome the free-draining issue raised above, and the technological advances that are needed to speed the development of competitive ELFSE-based sequencing and separation technologies. Finally, we also review the reverse process, called free-solution conjugate electrophoresis (FSCE), wherein uncharged polymers of different sizes can be analyzed using a short DNA molecule as an electrophoretic engine.

DNA↗

Simple, helical peptoid analogs of lung surfactant protein B.

The helical, amphipathic surfactant protein, SP-B, is a critical element of pulmonary surfactant and hence is an important therapeutic molecule. However, it is difficult to isolate from natural sources in high purity. We have created and studied three different, nonnatural analogs of a bioactive SP-B fragment (SP-B(1-25)), using oligo-N-substituted glycines (peptoids) with simple, repetitive sequences designed to favor the formation of amphiphilic helices. For comparison, a peptide with a similar repetitive sequence previously shown to be a good SP mimic was also studied, along with SP-B(1-25) itself. Surface pressure-area isotherms, surfactant film phase morphology, and dynamic adsorption behavior all indicate that the peptoids are promising mimics of SP-B(1-25). The extent of biomimicry appears to correlate with peptoid helicity and lipophilicity. These biostable oligomers could serve in a synthetic surfactant replacement to treat respiratory distress syndrome.

Circular Dichroism↗

Sparsely cross-linked "nanogel" matrixes as fluid, mechanically stabilized polymer networks for high-throughput microchannel DNA sequencing.

We have developed sparsely cross-linked "nanogels", subcolloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel replaceable DNA sequencing matrixes for capillary and microchip electrophoresis. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and a low percentage (approximately 10(-4) mol %) of N,N-methylene bisacrylamide (Bis). Nanogels and nanogel networks were characterized by multiangle laser light scattering and rheometry, respectively, and tested for DNA sequencing in both capillaries and chips with four-color LIF detection. Typical nanogels have an average radius of approximately 230 nm, with approximately 75% of chains incorporating a Bis cross-linker. The properties and performance of nanogel matrixes are compared here to those of a linear polyacrylamide (LPA) network, matched for both polymer weight-average molar mass (M(w)) and the extent of interchain entanglements (c/c). At sequencing concentrations, the two matrixes have similar flow characteristics, important for capillary and microchip loading. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, substantially longer average read lengths are obtained under standard conditions with the nanogel matrix at a 98.5% accuracy of base-calling (for CE: 680 bases, an 18.7% improvement over LPA, with the best reads as long as 726 bases, compared to 568 bases for the LPA matrix). We further investigated the use of the nanogel matrixes in a high-throughput microfabricated DNA sequencing device consists of 96 separation channels densely fabricated on a 6-in. glass wafer. Again, preliminary DNA sequencing results show that the nanogel matrixes are capable of delivering significantly longer average read length, compared to an LPA matrix of comparable properties. Moreover, nanogel matrixes require 30% less polymer per unit volume than LPA. The addition of a small amount of low molar mass LPA or ultrahigh molar mass LPA to the optimized nanogel sequencing matrix further improves read length as well as the reproducibility of read length (RSD < 1.6%). This is the first report of a replaceable DNA sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrixes appropriately matched for molar mass and the extent of interchain entanglements. These results could have significant implications for the improvement of microchip-based DNA sequencing technology.

Acrylic Resins↗

A very thin coating for capillary zone electrophoresis of proteins based on a tri(ethylene glycol)-terminated alkyltrichlorosilane.

We describe the use of a tri(ethylene glycol)-terminated alkyltrichlorosilane to create a very thin, protein-resistant "self-assembled monolayer" coating on the inner surface of a fused-silica capillary. The same compound has been demonstrated previously on flat silica substrates to resist adsorption of many proteins. As a covalently bound capillary coating, it displays good resistance to the adsorption of cationic proteins, providing clean separations of a mixture of lysozyme, cytochrome c, ribonuclease A, and myoglobin for more than 200 consecutive runs. Electroosmotic flow (EOF) was measured as a function of pH; the coated capillary retains significant cathodal EOF, with roughly 50% of the EOF of an uncoated capillary at neutral pH, making this coating promising for applications requiring some EOF. The EOF was reasonably stable, with a 2.9% relative standard deviation during a 24 h period consisting of 72 consecutive separations of cationic proteins. Efficiencies for cationic protein separations were moderate, in the range of 190,000-290,000 theoretical plates per meter. The coating procedure was simple, requiring only a standard cleaning procedure followed by a rinse with the silane reagent at room temperature. No buffer additives are required to maintain the stability of the coating, making it flexible for a range of applications, potentially including capillary electrophoresis-mass spectrometry (CE-MS).

Adsorption↗

Thermoresponsive N,N-dialkylacrylamide copolymer blends as DNA sieving matrices with a thermally tunable mesh size.

In an earlier study we showed that a blend of thermoresponsive and nonthermoresponsive hydroxyalkylcelluloses could be used to create a thermally tunable polymer network for double-stranded (ds) DNA separation. Here, we show the generality of this approach using a family of polymers suited to a wider range of DNA separations: a blended mixture of N,N-dialkylacrylamide copolymers with different thermoresponsive behaviors. A mixture of 47% w/w N,N-diethylacrylamide (DEA)/53% w/w N,N-dimethylacrylamide (DMA) (DEA47; thermoresponsive, transition temperature = 55 degrees C in water) and 30% w/w DEA/70% w/w DMA (DEA30; nonthermoresponsive, transition temperature > 85 degrees C in water) copolymers in the ratio of 1:5 w/w DEA47:DEA30 was used to separate a dsDNA restriction digest (PhiX174-HaeIII). We investigated the effects of changing mesh size on dsDNA separation, as controlled by temperature. We observed good DNA separation performance with the copolymer blend at temperatures ranging from 25 degrees C to 48 degrees C. The separation selectivity was evaluated quantitatively for certain DNA fragment pairs as a function of temperature. The results were compared with those obtained with a control matrix consisting only of the nonthermoresponsive DEA30. Different DNA fragment pairs of various sizes show distinct temperature-dependent selectivities. Over the same temperature range, no significant temperature dependence of selectivity is observed for these DNA fragment pairs in the nonthermoresponsive control matrix. Overall, the results show similar trends in the temperature dependency of separation selectivity to what was previously observed in hydroxyalkylcellulose blends, for the same DNA fragment pairs. Finally, we showed that a ramped temperature scheme enables improved separation in the blended copolymer matrix for both small and large DNA fragments, simultaneously in a single capillary electrophoresis (CE) run.

Acrylamide↗

DNA sequencing and genotyping in miniaturized electrophoresis systems.

Advances in microchannel electrophoretic separation systems for DNA analyses have had important impacts on biological and biomedical sciences, as exemplified by the successes of the Human Genome Project (HGP). As we enter a new era in genomic science, further technological innovations promise to provide other far-reaching benefits, many of which will require continual increases in sequencing and genotyping efficiency and throughput, as well as major decreases in the cost per analysis. Since the high-resolution size- and/or conformation-based electrophoretic separation of DNA is the most critical step in many genetic analyses, continual advances in the development of materials and methods for microchannel electrophoretic separations will be needed to meet the massive demand for high-quality, low-cost genomic data. In particular, the development (and commercialization) of miniaturized genotyping platforms is needed to support and enable the future breakthroughs of biomedical science. In this review, we briefly discuss the major sequencing and genotyping techniques in which high-throughput and high-resolution electrophoretic separations of DNA play a significant role. We review recent advances in the development of technology for capillary electrophoresis (CE), including capillary array electrophoresis (CAE) systems. Most of these CE/CAE innovations are equally applicable to implementation on microfabricated electrophoresis chips. Major effort is devoted to discussing various key elements needed for the development of integrated and practical microfluidic sequencing and genotyping platforms, including chip substrate selection, microchannel design and fabrication, microchannel surface modification, sample preparation, analyte detection, DNA sieving matrices, and device integration. Finally, we identify some of the remaining challenges, and some of the possible routes to further advances in high-throughput DNA sequencing and genotyping technologies.

Animals↗

Structural and spectroscopic studies of peptoid oligomers with alpha-chiral aliphatic side chains.

Substantial progress has been made in the synthesis and characterization of various oligomeric molecules capable of autonomous folding to well-defined, repetitive secondary structures. It is now possible to investigate sequence-structure relationships and the driving forces for folding in these systems. Here, we present detailed analysis by X-ray crystallography, NMR, and circular dichroism (CD) of the helical structures formed by N-substituted glycine (or "peptoid") oligomers with alpha-chiral, aliphatic side chains. The X-ray crystal structure of a N-(1-cyclohexylethyl)glycine pentamer, the first reported for any peptoid, shows a helix with cis-amide bonds, approximately 3 residues per turn, and a pitch of approximately 6.7 A. The backbone dihedral angles of this pentamer are similar to those of a polyproline type I peptide helix, in agreement with prior modeling predictions. This crystal structure likely represents the major solution conformers, since the CD spectra of analogous peptoid hexamers, dodecamers, and pentadecamers, composed entirely of either (S)-N-(1-cyclohexylethyl)glycine or (S)-N-(sec-butyl)glycine monomers, also have features similar to those of the polyproline type I helix. Furthermore, this crystal structure is similar to a solution NMR structure previously described for a peptoid pentamer comprised of chiral, aromatic side chains, which suggests that peptoids containing either aromatic or aliphatic alpha-chiral side chains adopt fundamentally similar helical structures in solution, despite distinct CD spectra. The elucidation of detailed structural information for peptoid helices with alpha-chiral aliphatic side chains will facilitate the mimicry of biomolecules, such as transmembrane protein domains, in a distinctly stable form.

Circular Dichroism↗

Helical peptoid mimics of magainin-2 amide.

A series of peptoid oligomers were designed as helical, cationic, and facially amphipathic mimics of the magainin-2 amide antibacterial peptide. We used circular dichroism spectroscopy to determine the conformation of these peptoids in aqueous buffer and in the presence of bacterial membrane-mimetic lipid vesicles, composed of a 7:3 mol ratio of POPE:POPG. We found that certain peptoids, which displayed characteristically helical CD in buffer and lipid vesicles, exhibit selective (nonhemolytic) and potent antibacterial activity against both Gram-positive and Gram-negative bacteria. In contrast, peptoids that exhibit weak CD, reminiscent of that of a peptide random coil, were ineffective antibiotics. In a manner similar to the natural magainin peptides, we find a correlation between peptoid lipophilicity and hemolytic propensity. We observe that a minimum length of approximately 12 peptoid residues may be required for antibacterial activity. We also see evidence that a helix length between 24 and 34 A may provide optimal antibacterial efficacy. These results provide the first example of a water-soluble, structured, bioactive peptoid.

Amides↗

Tandem isotachophoresis-zone electrophoresis via base-mediated destacking for increased detection sensitivity in microfluidic systems.

Electrophoresis in microfluidic devices is becoming a useful analytical platform for a variety of biological assays. In this report, we present a method that allows for an increased sensitivity of detection of fluorescent molecules in microfluidic electrophoresis devices. This capability is provided by the implementation of a particular buffer system that is designed to initially function in an isotachophoretic (ITP) mode and, then after a controlled amount of electric current has been applied to the system, to transition to a zone electrophoretic mode. In the initial ITP mode, analytes dissolved in a large volume of injected sample are concentrated into a single narrow zone. After application of a sufficient and adjustable amount of electric current, the system switches into a zone electrophoretic mode, where the concentrated analytes are separated according to their electrophoretic mobilities. Application of this tandem ITP-zone electrophoretic strategy to the concentration, separation, and detection of fluorescent reporter molecules in a standard microfluidic device results in an approximately 50-fold increase in detection sensitivity relative to equivalent separations that are obtained with zone electrophoresis alone. Even with very long initial sample plugs (up to 3000 microm), this strategy produces electrophoretic separations with high resolutions and peak efficiencies. This strategy can be implemented to increase detection sensitivity in any standard microfluidic electrophoresis platform and does not require any specialized hardware or microchannel configurations.

Buffers↗

A novel thermogelling matrix for microchannel DNA sequencing based on poly-N-alkoxyalkylacrylamide copolymers.

We have developed a novel class of thermogelling polymer networks based on poly-N-alkoxyalkylacrylamides, and demonstrated their use as DNA sequencing matrices for high-throughput microchannel electrophoresis in capillary arrays. Polymers and copolymers of N-ethoxyethylacrylamide (NEEA) and N-methoxyethylacrylamide (NMEA) were synthesized by aqueous-phase free-radical polymerization and characterized by tandem gel permeation chromatography-multi-angle laser light scattering. These copolymer matrices exhibit "re-entrant"-type volume phase transitions, forming entangled networks with high shear viscosity at low (< 20 degrees C) and high (> 35 degrees C) temperatures, and undergoing a "coil-to-globular", lower critical solution temperature (LCST)-like phase transition over an intermediate temperature range (20-35 degrees C). Hence, matrix viscosity is relatively low at room temperature (25 degrees C), and increases rapidly above 35 degrees C. The material properties and phase behavior of these thermogelling polymer networks were studied by steady-shear rheometry. These matrices are easily loaded into capillary arrays at room temperature while existing as viscous fluids, but thermogel above 35 degrees C to form transparent hydrogels via a thermo-associative phase transition. The extent of the intermediate viscosity drop and the final viscosity increase depends on the composition of the copolymers. DNA sequencing by capillary array electrophoresis with four-color laser-induced fluorescence (LIF) detection shows that these thermogelling networks provide enhanced resolution of both small and large DNA sequencing fragments and longer sequencing read lengths, in comparison to appropriate control (closely related, nonthermogelling) polymer networks. In particular, a copolymer comprised of 90% w/w NMEA and 10% w/w NEEA, with a molecular mass of approximately 2 MDa, delivers around 600 bases at 98.5% base-calling accuracy in 100 min of electrophoresis.

Acrylic Resins↗

Sparsely cross-linked "nanogels" for microchannel DNA sequencing.

We have developed sparsely cross-linked "nanogels", sub-colloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel DNA sequencing matrices for capillary electrophoresis. The presence of covalent cross-links affords nanogel matrices with enhanced network stability relative to standard, linear polyacrylamide (LPA), improving the separation of large DNA fragments. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and N,N-methylenebisacrylamide (Bis). In order to retain the fluidity necessary in a replaceable polymer matrix for capillary array electrophoresis (CAE), a low percentage of the Bis cross-linker (< 10(-4) mol%) was used. Nanogels were characterized by multiangle laser light scattering and rheometry, and were tested for DNA sequencing by CAE with four-color laser-induced fluorescence (LIF) detection. The properties and performance of nanogel matrices were compared to those of a commercially available LPA network, which was matched for both weight-average molar mass (Mw) and extent of interchain entanglements (c/c*). Nanogels presented in this work have an average radius of gyration of 226 nm and a weight-average molar mass of 8.8 x 10(6) g/mol. At concentrations above the overlap threshold, nanogels form a clear, viscous solution, similar to the LPA matrix (Mw approximately 8.9 x 10(6) g/mol). The two matrices have similar flow and viscosity characteristics. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, a substantially longer read length ( approximately 63 bases, a 10.4% improvement) is obtained with the nanogel matrix at 98.5% accuracy of base-calling. The nanogel network provides higher-selectivity separation of ssDNA sequencing fragments longer than 375 bases. Moreover, nanogel matrices require 30% less polymer per unit volume than LPA. This is the first report of a sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrices matched for Mw and extent of interchain entanglements.

Acrylic Resins↗

Microchannel wall coatings for protein separations by capillary and chip electrophoresis.

The necessity for microchannel wall coatings in capillary and chip-based electrophoretic analysis of biomolecules is well understood. The regulation or elimination of EOF and the prevention of analyte adsorption is essential for the rapid, efficient separation of proteins and DNA within microchannels. Microchannel wall coatings and other wall modifications are especially critical for protein separations, both in fused-silica capillaries, and in glass or polymeric microfluidic devices. In this review, we present a discussion of recent advances in microchannel wall coatings of three major classes--covalently linked polymeric coatings, physically adsorbed polymeric coatings, and small molecule additives. We also briefly review modifications useful for polymeric microfluidic devices. Within each category of wall coatings, we discuss those used to eliminate EOF, to tune EOF, to prevent analyte adsorption, or to perform multiple functions. The knowledgeable application of the most promising recent developments in this area will allow for the separation of complex protein mixtures and for the development of novel microchannel wall modifications.

Acrylic Resins↗

A DNA sieving matrix with thermally tunable mesh size.

We present a "proof-of-concept" study showing that a blend of thermo-responsive and nonthermo-responsive polymers can be used to create a DNA sieving matrix with a thermally tunable mesh size, or "dynamic porosity". Various blends of two well-studied sieving polymers for CE, including hydroxypropylcellulose (HPC), a thermo-responsive polymer, and hydroxyethylcellulose (HEC), a nonthermo-responsive polymer, were used to separate a double-stranded DNA restriction digest (Phi X174-HaeIII). HPC exhibits a volume-phase transition in aqueous solution which results in a collapse in polymer coil volume at approximately 39 degrees C. Utilizing a blend of HPC and HEC in a ratio of 1:5 by weight, we investigated the effects of changing mesh size on DNA separation, as controlled by temperature. High-resolution DNA separations were obtained with the blended matrix at temperatures ranging from 25 degrees C to 38 degrees C. We evaluated changes in the selectivity of DNA separation with increasing temperature for certain pairs of small and large fragments. A pure HEC (nonthermo-responsive) matrix was used over the same temperature range as a negative control. In the blended matrix, we observe a maximum in selectivity at approximately 31 degrees C for small DNA, while a significant increase in the selectivity of large-DNA separation occurs at approximately 36 degrees C as the polymer mesh "opens". We also demonstrate, through a temperature ramping experiment, that this matrix can be utilized to obtain high-resolution separation of both small and large DNA fragments simultaneously in a single CE run. Blended polymer matrices with "dynamic porosity" have the potential to provide enhanced genomic analysis by capillary array or microchip electrophoresis in microfluidic devices with advanced temperature control.

Bacteriophage phi X 174↗

Detection of Escherichia coli O157:H7 bacteria by a combination of immunofluorescent staining and capillary electrophoresis.

As the number of incidents of bacterial infections continues to rise around the globe, simpler, faster, and more sensitive diagnostic techniques are required to improve the safety of the food supply and to screen for potential bacterial infections in humans. We present here direct and indirect approaches for the detection of bacteria, which are based upon a combination of immunofluorescent staining and capillary electrophoresis. In the direct approach, Escherichia coli O157:H7 bacteria stained with fluorescein-tagged specific antibodies are detected by CE, while in the indirect approach fluorescein-tagged specific antibodies to E. coli are first captured by E. coli O157:H7 bacteria and then released and detected by CE. We have identified suitable bacteria staining and CE protocols, which involved a 10 mM Tris-borate-EDTA (TBE) buffer, 0.25 micro g antibody/1 million bacteria, and capillaries dynamically coated with poly-N-hydroxyethylacrylamide (polyDuramide). We have also successfully detected the presence of E. coli O157:H7 in contaminated meat. The total time required for analysis was 6-8 h, which is less than that realized in most commercial assays presently available.

Electrophoresis, Capillary↗

Poly-N-hydroxyethylacrylamide as a novel, adsorbed coating for protein separation by capillary electrophoresis.

We present the polymer poly-N-hydroxyethylacrylamide (PHEA) (polyDuramide) as a novel, hydrophilic, adsorbed capillary coating for electrophoretic protein analysis. Preparation of the PHEA coating requires a simple and fast (30 min) protocol that can be easily automated in capillary electrophoresis instruments. Over the pH range of 3-8.4, the PHEA coating is shown to reduce electroosmotic flow (EOF) by about 2 orders of magnitude compared to the bare silica capillary. In a systematic comparative study, the adsorbed PHEA coating exhibited minimal interactions with both acidic and basic proteins, providing efficient protein separations with excellent reproducibility on par with a covalent polyacrylamide coating. Hydrophobic interactions between proteins and a relatively hydrophobic poly-N,N-dimethylacrylamide (PDMA) adsorbed coating, on the other hand, adversely affected separation reproducibility and efficiency. Under both acidic and basic buffer conditions, the adsorbed PHEA coating produced an EOF suppression performance comparable to that of covalent polyacrylamide coating and superior to that of adsorbed PDMA coating. The protein separation performance in PHEA-coated capillaries was retained for 275 consecutive protein separation runs at pH 8.4, and for more than 800 runs at pH 4.4. The unique and novel combination of hydrophilicity and adsorptive coating ability of PHEA makes it a suitable wall coating for automated microscale analysis of proteins by capillary array systems.

Acrylic Resins↗