Search PubMed⌕ Search

Biomedical subjects

Anna M Wu

Publications and source records attributed to Anna M Wu.

24 records · Page 2Linked to original sources

Optical bioluminescence and positron emission tomography imaging of a novel fusion reporter gene in tumor xenografts of living mice.

Noninvasive imaging of reporter gene expression using various imaging modalitiesis playing an increasingly important role in defining molecular events in the field of cancer biology, cell biology, and gene therapy. In this study, a novel reporter vector was constructed encoding a fusion protein comprised of a mutant herpes simplex virus type 1 thymidine kinase (HSV1-sr39tk) (tk), a positron emission tomography (PET) reporter gene, and renilla luciferase (rl), a bioluminescence optical reporter gene joined by a 20 amino acid long spacer sequence. We validated the activity of the two enzymes encoded by the fusion protein (tk(20)rl) in cell culture. Then, tumors stably expressing the tk(20)rl fusion gene were imaged both by microPET and optically using a cooled charge coupled device camera in xenograft-bearing living mice. Using a single fusion reporter (PET/optical) gene should accelerate the validation of reporter gene approaches developed in cell culture for translation into preclinical and clinical models.

Amino Acid Sequence↗

The crystal structure of an anti-CEA scFv diabody assembled from T84.66 scFvs in V(L)-to-V(H) orientation: implications for diabody flexibility.

Diabodies (scFv dimers) are small, bivalent antibody mimetics of approximately 55kDa in size that possess rapid in vivo targeting pharmacokinetics compared to the intact parent antibody, and may prove highly suitable for imaging and therapeutic applications. Here, we describe T84.66Di, the first diabody crystal structure in which the scFvs comprise V domains linked in the V(L)-to-V(H) orientation. The structure was determined by X-ray diffraction analysis to 2.6 A resolution. The T84.66Di scFv was constructed from the anti-carcinoembryonic antigen (anti-CEA) antibody T84.66 variable domains connected by an eight residue peptide linker to provide flexibility between Fv modules and promote dimer formation with bivalent affinity to the cell-surface target, CEA. Therefore, it was surprising to observe a close association of some Fv module complementarity-determining regions in the T84.66 diabody crystal, especially compared to other diabody structures all of which are linked in the opposite V(H)-to-V(L) orientation. The differences between the arrangement of Fv modules in the T84.66Di V(L)-to-V(H) linked diabody structure compared to the crystal structure of L5MK16 and other proposed V(H)-to-V(L) linked diabodies has been investigated and their potential for flexibility discussed. The comparison between V(H)-to-V(L) and V(L)-to-V(H) linked diabodies revealed in this study represents a limited repertoire of possible diabody Fv orientations, but one that reveals the potential flexibility of these molecules. This analysis therefore provides some signposts that may impact on future molecular designs for these therapeutic molecules with respect to diabody flexibility and avidity.

Antibodies, Bispecific↗

124I-labeled engineered anti-CEA minibodies and diabodies allow high-contrast, antigen-specific small-animal PET imaging of xenografts in athymic mice.

UNLABELLED: Prolonged clearance kinetics have hampered the development of intact antibodies as imaging agents, despite their ability to effectively deliver radionuclides to tumor targets in vivo. Genetically engineered antibody fragments display rapid, high-level tumor uptake coupled with rapid clearance from the circulation in the athymic mouse/LS174T xenograft model. The anticarcinoembryonic antigen (CEA) T84.66 minibody (single-chain Fv fragment [scFv]-C(H)3 dimer, 80 kDa) and T84.66 diabody (noncovalent dimer of scFv, 55 kDa) exhibit pharmacokinetics favorable for radioimmunoimaging. The present work evaluated the minibody or diabody labeled with (124)I, for imaging tumor-bearing mice using a high-resolution small-animal PET system. METHODS: Labeling was conducted with 0.2-0.3 mg of protein and 65-98 MBq (1.7-2.6 mCi) of (124)I using an iodination reagent. Radiolabeling efficiencies ranged from 33% to 88%, and immunoreactivity was 42% (diabody) or >90% (minibody). In vivo distribution was evaluated in athymic mice bearing paired LS174T human colon carcinoma (CEA-positive) and C6 rat glioma (CEA-negative) xenografts. Mice were injected via the tail vein with 1.9-3.1 MBq (53-85 microCi) of (124)I-minibody or with 3.1 MBq (85 microCi) of (124)I-diabody and imaged at 4 and 18 h by PET. Some mice were also imaged using (18)F-FDG 2 d before imaging with (124)I-minibody. RESULTS: PET images using (124)I-labeled minibody or diabody showed specific localization to the CEA-positive xenografts and relatively low activity elsewhere in the mice, particularly by 18 h. Target-to-background ratios for the LS174T tumors versus soft tissues using (124)I-minibody were 3.05 at 4 h and 11.03 at 18 h. Similar values were obtained for the (124)I-diabody (3.95 at 4 h and 10.93 at 18 h). These results were confirmed by direct counting of tissues after the final imaging. Marked reduction of normal tissue activity, especially in the abdominal region, resulted in high-contrast images at 18 h for the (124)I-anti-CEA diabody. CEA-positive tumors as small as 11 mg (<3 mm in diameter) could be imaged, and (124)I-anti-CEA minibodies, compared with (18)F-FDG, demonstrated highly specific localization. CONCLUSION: (124)I labeling of engineered antibody fragments provides a promising new class of tumor-specific probes for PET imaging of tumors and metastases.

Animals↗

An internet-based "kinetic imaging system" (KIS) for MicroPET.

Many considerations, involving understanding and selection of multiple experimental parameters, are required to perform MicroPET studies properly. The large number of these parameters/variables and their complicated interdependence make their optimal choice nontrivial. We have a developed kinetic imaging system (KIS), an integrated software system, to assist the planning, design, and data analysis of MicroPET studies. The system serves multiple functions-education, virtual experimentation, experimental design, and image analysis of simulated/experimental data-and consists of four main functional modules--"Dictionary," "Virtual Experimentation," "Image Analysis," and "Model Fitting." The "Dictionary" module provides didactic information on tracer kinetics, pharmacokinetic, MicroPET imaging, and relevant biological/pharmacological information. The "Virtual Experimentation" module allows users to examine via computer simulations the effect of biochemical/pharmacokinetic parameters on tissue tracer kinetics. It generates dynamic MicroPET images based on the user's assignment of kinetics or kinetic parameters to different tissue organs in a 3-D digital mouse phantom. Experimental parameters can be adjusted to investigate the design options of a MicroPET experiment. The "Image Analysis" module is a full-fledged image display/manipulation program. The "Model Fitting" module provides model-fitting capability for measured/simulated tissue kinetics. The system can be run either through the Web or as a stand-alone process. With KIS, radiotracer characteristics, administration method, dose level, imaging sequence, and image resolution-to-noise tradeoff can be evaluated using virtual experimentation. KIS is designed for biology/pharmaceutical scientists to make learning and applying tracer kinetics fun and easy.

Animals↗

Improved biodistribution and radioimmunoimaging with poly(ethylene glycol)-DOTA-conjugated anti-CEA diabody.

Diabodies are single chain antibody fragments (scFvs) that spontaneously form bivalent dimers of molecular size 50-55000. Radiolabeled diabodies are almost ideal tumor targeting agents due to their high avidity (bivalent) binding to tumor antigens and small size (50-55000) that leads to improved tumor-to-blood ratio compared to intact antibodies (150000). However, due to their high retention and metabolism in the kidney, radioiodine is the current radiolabel of choice for diabodies since radioiodine is rapidly excreted from the kidney once metabolized. We have previously shown that 111In-DOTA-diabody gives higher tumor uptake in nude mouse xenografts than 125I-diabody, but has extremely high kidney retention since its 111In-labeled metabolites are retained by and only slowly excreted from the kidney. When a diabody is conjugated to a bifunctional PEG-3400 derivative followed by reaction with cysteinyl-DOTA, the resulting product has an apparent molecular size of 75000 and a Stokes radius of 35 angstroms on size exclusion chromatography, compared to a Stokes radius of 25 angstroms for intact diabody. When radiolabeled, the conjugate gives high yields of 111In-labeled product, retains high immunoreactivity, and gives improved biodistributions (30-40%ID/g, 12-48 h) compared to 111In-DOTA-diabody (12-13%ID/g, 6-12 h). We show that the improved biodistribution is due to an increase in Stokes radius caused by the linear PEG-3400 since conjugation of diabody with multiple (PEG)12 linkers followed by reaction with cysteinyl-DOTA does not reduce kidney accumulation. We also show that 111In-cysteinyl-DOTA-PEG3400-diabody gives excellent tumor images in the nude mouse xenograft model and that 125I-PEG3400-diabody gives equivalent images to 125I-minibody (molecular size, 80000), but improved tumor-to-liver ratios, suggesting that this imaging agent can be used to image liver metastases.

Animals↗