Search PubMed⌕ Search

Biomedical subjects

Anil A Bharath

Publications and source records attributed to Anil A Bharath.

4 recordsLinked to original sources

Segmentation of blood vessels from red-free and fluorescein retinal images.

The morphology of the retinal blood vessels can be an important indicator for diseases like diabetes, hypertension and retinopathy of prematurity (ROP). Thus, the measurement of changes in morphology of arterioles and venules can be of diagnostic value. Here we present a method to automatically segment retinal blood vessels based upon multiscale feature extraction. This method overcomes the problem of variations in contrast inherent in these images by using the first and second spatial derivatives of the intensity image that gives information about vessel topology. This approach also enables the detection of blood vessels of different widths, lengths and orientations. The local maxima over scales of the magnitude of the gradient and the maximum principal curvature of the Hessian tensor are used in a multiple pass region growing procedure. The growth progressively segments the blood vessels using feature information together with spatial information. The algorithm is tested on red-free and fluorescein retinal images, taken from two local and two public databases. Comparison with first public database yields values of 75.05% true positive rate (TPR) and 4.38% false positive rate (FPR). Second database values are of 72.46% TPR and 3.45% FPR. Our results on both public databases were comparable in performance with other authors. However, we conclude that these values are not sensitive enough so as to evaluate the performance of vessel geometry detection. Therefore we propose a new approach that uses measurements of vessel diameters and branching angles as a validation criterion to compare our segmented images with those hand segmented from public databases. Comparisons made between both hand segmented images from public databases showed a large inter-subject variability on geometric values. A last evaluation was made comparing vessel geometric values obtained from our segmented images between red-free and fluorescein paired images with the latter as the "ground truth". Our results demonstrated that borders found by our method are less biased and follow more consistently the border of the vessel and therefore they yield more confident geometric values.

Algorithms↗

Numerical study of short-term afterimages and associate properties in foveal vision.

A cellular model of the primate retina has been developed. Unlike existing models, it incorporates spatial non-uniformities, such as the random arrangement of L and M cones, and the radial dilation with eccentricity. Based on a population of ganglion cell activities, colour-image representation is modelled with the luminance and the R-G opponent channels. The developed model reproduces experimentally known properties in temporal and spatial vision. Furthermore, spatio-temporally coupled properties such as transition from positive to negative phases in an afterimage, are recapped. In colour vision, the model can explain the insensitivity in our colour perception to the L/M cone ratio.

Afterimage↗

Carotid artery wall motion estimated from B-mode ultrasound using region tracking and block matching.

The motion of the carotid atheromatous plaque relative to the adjacent wall may be related to the risk of cerebral events. A quantitative method for motion estimation was applied to analyse arterial wall movement from sequences of 2-D B-mode ultrasound (US) images. Image speckle patterns were tracked between successive frames using the correlation coefficient as the matching criterion. The size of the selected region-of-interest (ROI) was shown to affect the motion analysis results; an optimal size of 3.2 x 2.5 mm(2) was suggested for tracking a region at the wall-lumen interface and of 6.3 x 2.5 mm(2) for one within the tissue. The results showed expected cyclical motion in the radial direction and some axial movement of the arterial wall. The method can be used to study further the axial motion of the carotid artery wall and plaque and, thus, provide useful insight into the mechanisms of atherosclerosis.

Carotid Arteries↗

Retinal vascular tree morphology: a semi-automatic quantification.

A semi-automatic method to measure and quantify geometrical and topological properties of continuous vascular trees in clinical fundus images is described. Measurements are made from binary images obtained with a previously described segmentation process. The skeletons of the segmented trees are produced by thinning,ff branch and crossing points are identified and segments of the trees are labeled and stored as a chain code. The operator selects a tree to be measured and decides if it is an arterial or venous tree. An automatic process then measures the lengths, areas and angles of the individual segments of the tree. Geometrical data and the connectivity information between branches from continuous retinal vessel trees are tabulated. A number of geometrical properties and topological indexes are derived. Vessel diameters and branching angles are validated against manual measurements and several derived geometrical and topological properties are extracted from red-free fundus images of ten normotensive and ten age- and sex-matched hypertensive subjects and compared with previously reported results.

Adult↗