Search PubMed⌕ Search

Biomedical subjects

Andrew J Pullan

Publications and source records attributed to Andrew J Pullan.

18 recordsLinked to original sources

An integrative software package for gastrointestinal biomagnetic data acquisition and analysis using SQUID magnetometers.

The study of bioelectric and biomagnetic activity in the human gastrointestinal (GI) tract is of great interest in clinical research due to the proven possibility to detect pathological conditions thereof from electric and magnetic field recordings. The magnetogastrogram (MGG) and magnetoenterogram (MENG) can be recorded using superconducting quantum interference device (SQUID) magnetometers, which are the most sensitive magnetic flux-to-voltage converters currently available. To address the urgent need for powerful acquisition and analysis software tools faced by many researchers and clinicians in this important area of investigation, an integrative and modular computer program was developed for the acquisition, processing and analysis of GI SQUID signals. In addition to a robust hardware implementation for efficient data acquisition, a number of signal processing and analysis modules were developed to serve in a variety of both clinical procedures and scientific investigations. Implemented software features include data processing and visualization, waterfall plots of signal frequency spectra as well as spatial maps of GI signal frequencies. Moreover, a software tool providing powerful 3D visualizations of GI signals was created using realistic models of the human torso and internal organs.

Gastrointestinal Diseases↗

Modelling slow wave activity in the small intestine.

We have developed an anatomically based model to simulate slow wave activity in the small intestine. Geometric data for the human small intestine were obtained from the Visible Human project. These data were used to create a one-dimensional finite element mesh of the entire small intestine using an iterative fitting procedure. The electrically active components of the intestinal walls were modelled using a modified Fitzhugh-Nagumo cell model embedded within a longitudinal smooth muscle layer and a layer containing Interstitial Cells of Cajal. Within these layers, the monodomain equation was used to describe slow wave propagation. To solve the monodomain equation, a high-resolution finite difference grid, with an average spatial resolution of 0.95 mm, was embedded within each finite element. The resulting simulations of intestinal activity agree with the experimental observation that slow wave frequency gradually declines from 12 cycles per minute (cpm) in the duodenum to 8 cpm at the terminal ileum. Furthermore, the simulations demonstrated a decrease in conduction velocity with distance along the small intestine (10.7 cm/s in the duodenum, 5.1cm/s in the jejunum and 1.4 cm/s in the ileum), matching experimental recordings from the canine small intestine. We conclude that the framework presented here is capable of qualitatively simulating normal slow wave activity in an anatomical model of the small intestine.

Finite Element Analysis↗

Cardiac electrophysiology and tissue structure: bridging the scale gap with a joint measurement and modelling paradigm.

Significant tissue structures exist in cardiac ventricular tissue that are of supracellular dimension. It is hypothesized that these tissue structures contribute to the discontinuous spread of electrical activation, may contribute to arrhymogenesis and also provide a substrate for effective cardioversion. However, the influences of these mesoscale tissue structures in intact ventricular tissue are difficult to understand solely on the basis of experimental measurement. Current measurement technology is able to record at both the macroscale tissue level and the microscale cellular or subcellular level, but to date it has not been possible to obtain large volume, direct measurements at the mesoscales. To bridge this scale gap in experimental measurements, we use tissue-specific structure and mathematical modelling. Our models have enabled us to consider key hypotheses regarding discontinuous activation. We also consider the future developments of our intact tissue experimental programme.

Action Potentials↗

Solving the cardiac bidomain equations for discontinuous conductivities.

Fast simulations of cardiac electrical phenomena demand fast matrix solvers for both the elliptic and parabolic parts of the bidomain equations. It is well known that fast matrix solvers for the elliptic part must address multiple physical scales in order to show robust behavior. Recent research on finding the proper solution method for the bidomain equations has addressed this issue whereby multigrid preconditioned conjugate gradients has been used as a solver. In this paper, a more robust multigrid method, called Black Box Multigrid, is presented as an alternative to conventional geometric multigrid, and the effect of discontinuities on solver performance for the elliptic and parabolic part is investigated. Test problems with discontinuities arising from inserted plunge electrodes and naturally occurring myocardial discontinuities are considered. For these problems, we explore the advantages to using a more advanced multigrid method like Black Box Multigrid over conventional geometric multigrid. Results will indicate that for certain discontinuous bidomain problems Black Box Multigrid provides 60% faster simulations than using conventional geometric multigrid. Also, for the problems examined, it will be shown that a direct usage of conventional multigrid leads to faster simulations than an indirect usage of conventional multigrid as a preconditioner unless there are sharp discontinuities.

Action Potentials↗

Do intramural virtual electrodes facilitate successful defibrillation? Model-based analysis of experimental evidence.

INTRODUCTION: Recent computer model and experimental studies have suggested that microscopic intramural collagenous planes may facilitate successful defibrillation through the generation of shock-induced virtual electrodes deep within the ventricular wall. Evidence supporting the existence of intramural virtual electrodes has been drawn from several recent studies, which map shock-induced membrane potential (Vm) over the cut transmural surface of dissected segments of porcine left ventricle (LV). The artificially created transmural boundary in these experiments is impermeable to intracellular current. It is not known how this constraint limits the interpretation of these experiments in terms of the shock response of the intact ventricle. METHODS AND RESULTS: This study uses a realistic 3D computer model of LV myocardium to aid experimental interpretation. The model incorporates a microstructural description of intramural cleavage plane discontinuities measured by confocal microscopy of rat LV. Electrical shocks are applied across the model tissue, with and without introduced transmural boundaries. Shocks of varying strength (4-40 V/cm) are also applied to the model and the response analyzed. Results show that shock-induced Vm changes (deltaVm) on a transmural tissue boundary are significantly different to deltaVm of the intact ventricle, and the extent of difference depends on boundary orientation. However, the presence and qualitative behavior of intramural virtual electrodes is preserved irrespective of boundary placement. The model also confirms experimental observations that most rapid transmural activation occurs for shocks of strength 5-10 V/cm. Two distinct mechanisms suppress virtual electrode propagation, and hence slow tissue activation, outside of this optimal shock strength range. CONCLUSIONS: This study supports the hypothesis that distributed microscopic intramural virtual electrodes contribute to rapid activation of the ventricular wall during defibrillation.

Animals↗

Modeling cardiac electrical activity at the cell and tissue levels.

Significant tissue structures exist in cardiac ventricular tissue, which are of supracellular dimension. It is hypothesized that these tissue structures contribute to the discontinuous spread of electrical activation, may contribute to arrhythmogenesis, and also provide a substrate for effective cardioversion. However, the influences of these mesoscale tissue structures in intact ventricular tissue are difficult to understand solely on the basis of experimental measurement. Current measurement technology is able to record at both the macroscale tissue level and the microscale cellular or subcellular level, but to date it has not been possible to obtain large volume, direct measurements at the mesoscales. To bridge this scale gap in experimental measurements, we use tissue-specific structure and mathematical modeling. Our models, which can incorporate ion channel models at the cell level into the reaction-diffusion equations at the tissue level, have enabled us to consider key hypotheses regarding discontinuous activation.

Heart↗

A generalized finite difference method for modeling cardiac electrical activation on arbitrary, irregular computational meshes.

A generalized finite difference (GFD) method is presented that can be used to solve the bi-domain equations modeling cardiac electrical activity. Classical finite difference methods have been applied by many researchers to the bi-domain equations. However, these methods suffer from the limitation of requiring computational meshes that are structured and orthogonal. Finite element or finite volume methods enable the bi-domain equations to be solved on unstructured meshes, although implementations of such methods do not always cater for meshes with varying element topology. The GFD method solves the bi-domain equations on arbitrary and irregular computational meshes without any need to specify element basis functions. The method is useful as it can be easily applied to activation problems using existing meshes that have originally been created for use by finite element or finite difference methods. In addition, the GFD method employs an innovative approach to enforcing nodal and non-nodal boundary conditions. The GFD method performs effectively for a range of two and three-dimensional test problems and when computing bi-domain electrical activation moving through a fully anisotropic three-dimensional model of canine ventricles.

Algorithms↗

Intramural measurement of transmembrane potential in the isolated pig heart: validation of a novel technique.

INTRODUCTION: Transmembrane potentials can be recorded at multiple intramural sites in the intact heart using fiber optic probes or optrodes. The technique has considerable potential utility for studies of arrhythmia and defibrillation, but has not been validated in large mammalian hearts. METHODS AND RESULTS: An optrode was used to acquire intramural transmembrane potentials in six isolated Langendorff-perfused pig hearts. Mechanical activity was suppressed with 2,3-butanedione monoxime (BDM). Excitation light (488 nm) was delivered to and fluorescence collected from six sites, each spaced 1.4 mm apart across the left ventricle (LV) free wall that was stained with di-4 ANEPPS. Intramural membrane potentials were compared with extracellular potentials recorded at adjacent locations in sinus rhythm, and during atrial and subepicardial ventricular pacing (1-3 Hz). In three hearts, epicardial intracellular potentials were also measured close to the optrode. Optical action potentials were reproducible, with no significant transmural variation in morphology. There was close correspondence between subepicardial optical and intracellular potentials (R2 = 0.948, n = 23). The onset of activation at and its progression across adjacent optical and extracellular recording sites were consistent, as was the variation of action potential duration (APD) with cycle length. However, there was greater variability in absolute APD estimated from optical and extracellular records (R2 = 0.773, n = 258). Comparison of extracellular potentials at the same intramural sites in vivo confirms that heart isolation and BDM slow electrical propagation and depress restitution relationships, but otherwise preserve intramural patterns of electrical activation. CONCLUSIONS: We have demonstrated that our optrode provides reliable intramural transmembrane potential recordings in the isolated pig heart preparation.

Action Potentials↗

Challenges facing validation of noninvasive electrical imaging of the heart.

Noninvasive imaging of regional cardiac electrophysiology remains an elusive target. Such imaging is still in its infancy, particularly in comparison to structural imaging modalities such as magnetic resonance imaging (MRI), x-ray computed tomography (CT), and ultrasound. We present an overview of noninvasive ECG imaging, and the challenges and successes of the various techniques across a range of applications. Unlike MRI and CT, reconstructing cardiac electrophysiology from remote body surface measurements is a highly ill-posed problem. We therefore first review the theoretical considerations and associated algorithms that are used to address this issue. We then focus on the important issue of validation, and review and contrast recent advances in this area. Efforts to validate ECG inverse procedures using a modeling-based approach are addressed first. We then discuss various experimental studies that have been conducted to provide appropriate data for robust validations. We present new data that are simultaneously recorded from dense arrays of electrodes on the epicardium and body surface of anesthetized pigs during sinus rhythm, ventricular pacing, and regional ischemia. These data have been obtained specifically to help validate inverse ECG procedures, and form a useful supplement to recent clinical validation studies. Finally, clinical applications and outstanding issues regarding noninvasive imaging of regional cardiac electrophysiology are addressed.

Algorithms↗

Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in hearts.

Fast voltage-sensitive dyes are widely used to image cardiac electrical activity. Typically, the emission spectrum of these fluorochromes is wavelength shifted with altered membrane potential, but the optical signals obtained also decay with time and are affected by contraction. Ratiometry reduces, but may not fully remove, these artifacts. An alternate approach has been developed in which the time decay in simultaneously acquired short- and long-wavelength signals is characterized nonparametrically and removed. Motion artifact is then identified as the time-varying signal component common to both decay-corrected signals and subtracted. Performance of this subtraction technique was compared with ratiometry for intramural optical signals acquired with a fiber-optic probe in an isolated, Langendorff-perfused pig heart preparation (n = 4) stained with di-4-ANEPPS. Perfusate concentration of 2,3-butanedione monoxime was adjusted (7.5-12.5 mM) to alter contractile activity. Short-wavelength (520-600 nm) and long-wavelength (>600 nm) signals were recorded over 8-16 cardiac cycles at 6 sites across the left ventricular free wall in sinus rhythm and during pacing. A total of 451 such data sets were acquired. Appreciable wall motion was observed in 225 cases, with motion artifact classed as moderate (less than modulation due to action potential) in 187 and substantial (more than modulation due to action potential) in 38. In all cases, subtraction performed as well as, or better than, ratiometry in removing motion artifact and decay. Action potential morphology was recovered more faithfully by subtraction than by ratiometry in 58 of 187 and 31 of 38 cases with moderate and substantial motion artifact, respectively. This novel subtraction approach may therefore provide a means of reducing the concentration of uncoupling agents used in cardiac optical mapping studies.

Action Potentials↗

Cardiac structure and electrical activation: models and measurement.

1. Our group has developed finite element models of ventricular anatomy that incorporate detailed structural information. These have been used to study normal electrical activation and re-entrant arrhythmia. 2. A model based on the actual three-dimensional microstructure of a transmural left ventricular (LV) segment predicts that cleavage planes between muscle layers may give rise to non-uniform, anisotropic electrical propagation and also provide a substrate for bulk resetting of the myocardium during defibrillation. 3. The model predictions are consistent with the results of preliminary experiments in which a novel fibre-optic probe is used to record transmembrane potentials at multiple intramural sites in the intact heart. Extracellular potentials are recorded at adjacent LV sites in these studies. 4. We conclude that structural discontinuities in ventricular myocardium may play a role in the initiation of re-entrant arrhythmia and discuss future studies that address this hypothesis.

Animals↗

Cardiac electrical activity--from heart to body surface and back again.

We report here on our latest developments in the forward and inverse problems of electrocardiology. In the forward problem, a coupled cellular model of cardiac excitation-contraction is embedded within an anatomically realistic model of the cardiac ventricles, which is itself embedded within a torso model. This continuum modelling framework allows the effects of cellular-level activity on the surface electrocardiogram (ECG) to be carefully examined. Furthermore, the contributions of contraction and local ischemia on body surface recordings can also be elucidated. Such information can provide theoretical limits to the sensitivity and ultimately the detection capability of body surface ECG recordings. Despite being very useful, such detailed forward modelling is not directly applicable when seeking to use densely sampled ECG information to assess a patient in a clinical environment (the inverse problem). In such a situation patient specific models must be constructed and, due to the nature of the inverse problem, the level of detail that can be reliably reproduced is limited. Extensive simulation studies have shown that the accuracy with which the heart is localised within the torso is the primary limiting factor. To further identify the practical performance capabilities of the current inverse algorithms, high quality experimental data is urgently needed. We have been working towards such an objective with a number of groups, including our local hospital in Auckland. At that hospital, in patients undergoing catheter ablation surgery, up to 256 simultaneous body surface signals were recorded by using various catheter pacing protocols. The geometric information required to customize the heart and torso model was obtained using a combination of ultrasound and laser scanning technologies. Our initial results indicate that such geometric imaging modalities are sufficient to produce promising inversely-constructed activation profiles.

Algorithms↗

Altered T wave dynamics in a contracting cardiac model.

INTRODUCTION: The implications of mechanical deformation on calculated body surface potentials are investigated using a coupled biophysically based model. METHODS AND RESULTS: A cellular model of cardiac excitation-contraction is embedded in an anatomically accurate two-dimensional transverse cross-section of the cardiac ventricles and human torso. Waves of activation and contraction are induced by the application of physiologically realistic boundary conditions and solving the bidomain and finite deformation equations. Body surface potentials are calculated from these activation profiles by solving Laplace's equation in the passive surrounding tissues. The effect of cardiac deformation on electrical activity, induced by contraction, is demonstrated in both single-cell and tissue models. Action potential duration is reduced by 7 msec when the single cell model is subjected to a 10% contraction ramp applied over 400 msec. In the coupled electromechanical tissue model, the T wave of the ECG is shown to occur 18 msec earlier compared to an uncoupled excitation model. To assess the relative effects of myocardial deformation on the ECG, the activation sequence and tissue deformation are separated. The coupled and uncoupled activation sequences are mapped onto the undeforming and deforming meshes, respectively. ECGs are calculated for both mappings. CONCLUSION: Adding mechanical contraction to a mathematical model of the heart has been shown to shift the T wave on the ECG to the left. Although deformation of the myocardium resulting from contraction reduces the T wave amplitude, cell stretch producing altered cell membrane kinetics is the major component of this temporal shift.

Action Potentials↗

Effects of experimental and modeling errors on electrocardiographic inverse formulations.

The inverse problem of electrocardiology aims to reconstruct the electrical activity occurring within the heart using information obtained noninvasively on the body surface. Potentials obtained on the torso surface can be used as input for the inverse problem and an electrical image of the heart obtained. There are a number of different inverse algorithms currently used to produce electrical images of the heart. The relative performances of these inverse algorithms at this stage is largely unknown. Although there have been many simulation studies investigating the accuracy of each of these algorithms, to date, there has been no comprehensive study which compares a wide variety of inverse methods. By performing a detailed simulation study, we compare the performances of epicardial potential [Tikhonov, Truncated singular value decomposition (TSVD), and Greensite] and myocardial activation-based (critical point) inverse simulations along with different methods of choosing the appropriate level of regularization (optimal, L-curve, composite residual and smoothing operator, zero-crossing) to apply to each of these inverse methods. We also examine the effects of a variety of signal error, material property error, geometric error and a combination of these errors on each of the electrocardiographic inverse algorithms. Results from the simulation study show that the activation-based method is able to produce solutions which are more accurate and stable than potential-based methods especially in the presence of correlated errors such as geometric uncertainty. In general, the Greensite-Tikhonov method produced the most realistic potential-based solutions while the zero-crossing and L-curve were the preferred method for determining the regularization parameter. The presence of signal or material property error has little effect on the inverse solutions when compared with the large errors which resulted from the presence of any geometric error. In the presence of combined Gaussian and correlated errors representing conditions which may be encountered in an experimental or clinical environment, there was less variability between potential-based solutions produced by each of the inverse algorithms.

Algorithms↗

Comparison of potential- and activation-based formulations for the inverse problem of electrocardiology.

Two predominant source formulations for the inverse problem of electrocardiology currently exist. They involve the reconstruction of epicardial potentials or myocardial activation times from noninvasively recorded torso surface potentials. Each of these formulations have their advantages, however, they have not been systematically compared against each other. We present results from a simulation study which compared a number of epicardial potential (Tikhonov, Truncated singular value decomposition (TSVD), Greensite-Tikhonov and Greensite-TSVD), and a myocardial activation time formulation for the inverse problem of electrocardiology. A number of different methods were also used to determine the appropriate level of regularization (optimal, L-curve, zero-crossing, and composite residual and smoothing operator) to apply to each formulation. The simulation study was conducted using an anatomically based boundary element porcine model with a variety of cardiac sources. Varying levels of geometric error were introduced to the system and solutions were computed using each of the inverse algorithms. Results show that under pure Gaussian noise potential-based methods performed best at low noise levels while the activation-based method was less effected by higher noise levels. In the presence of correlated geometric error, the activation-based method out performed the potential methods, with the Greensite-Tikhonov method being the most favored potential-based method when using the L-curve or zero-crossing method to determine the regularization parameter.

Algorithms↗

The effect of torso impedance on epicardial and body surface potentials: a modeling study.

Experimental results have been published that report marked changes in measured epicardial potentials when the conductivity of the material surrounding the heart is altered. These reports raise a question as to the validity of the traditional two step, equivalent cardiac source approach to modeling the forward problem of electrocardiology as the equivalent source calculation occurs in what is effectively an isolated cardiac region. In the physical situation the heart is surrounded by a torso that contains many different tissue types with different conductivities and is certainly not isolated. Here, a fully coupled model of the problem is employed where the electrical pathways are continuous from a cellular level through to the body surface. This model is used to investigate the effects that torso inhomogeneities have on epicardial and body surface potentials, including comparisons with a traditional two step approach. In particular, it is shown that adding lungs changes the epicardial potentials by 17%, which is consistent with the reported experimental results. In none of the tested situations did the equivalent source approach completely reproduce the fully coupled results, supporting the notion that a fully coupled approach is required to properly solve the forward problem of electrocardiology.

Abdomen↗

Modeling total heart function.

Computational models of the electrical and mechanical function of the heart are reviewed. These models attempt to explain the integrated function of the heart in terms of ventricular anatomy, the structure and material properties of myocardial tissue, the membrane ion channels, and calcium handling and myofilament mechanics of cardiac myocytes. The models have established the computational framework for linking the structure and function of cardiac cells and tissue to the integrated behavior of the intact heart, but many more aspects of physiological function, including metabolic and signal transduction pathways, need to be included before significant progress can be made in understanding many disease processes.

Animals↗

Cardiac microstructure: implications for electrical propagation and defibrillation in the heart.

Our understanding of the electrophysiological properties of the heart is incomplete. We have investigated two issues that are fundamental to advancing that understanding. First, there has been widespread debate over the mechanisms by which an externally applied shock can influence a sufficient volume of heart tissue to terminate cardiac fibrillation. Second, it has been uncertain whether cardiac tissue should be viewed as an electrically orthotropic structure, or whether its electrical properties are, in fact, isotropic in the plane orthogonal to myofiber direction. In the present study, a computer model that incorporates a detailed three-dimensional representation of cardiac muscular architecture is used to investigate these issues. We describe a bidomain model of electrical propagation solved in a discontinuous domain that accurately represents the microstructure of a transmural block of rat left ventricle. From analysis of the model results, we conclude that (1) the laminar organization of myocytes determines unique electrical properties in three microstructurally defined directions at any point in the ventricular wall of the heart, and (2) interlaminar clefts between layers of cardiomyocytes provide a substrate for bulk activation of the ventricles during defibrillation.

Animals↗