Andrew E Epstein

Publications and source records attributed to Andrew E Epstein.

45 records · Page 3Linked to original sources

Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.

CONTEXT: Implantable cardioverter defibrillator (ICD) therapy with backup ventricular pacing increases survival in patients with life-threatening ventricular arrhythmias. Most currently implanted ICD devices provide dual-chamber pacing therapy. The most common comorbid cause for mortality in this population is congestive heart failure. OBJECTIVE: To determine the efficacy of dual-chamber pacing compared with backup ventricular pacing in patients with standard indications for ICD implantation but without indications for antibradycardia pacing. DESIGN: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial, a single-blind, parallel-group, randomized clinical trial. SETTING AND PARTICIPANTS: A total of 506 patients with indications for ICD therapy were enrolled between October 2000 and September 2002 at 37 US centers. All patients had a left ventricular ejection fraction (LVEF) of 40% or less, no indication for antibradycardia pacemaker therapy, and no persistent atrial arrhythmias. INTERVENTIONS: All patients had an ICD with dual-chamber, rate-responsive pacing capability implanted. Patients were randomly assigned to have the ICDs programmed to ventricular backup pacing at 40/min (VVI-40; n = 256) or dual-chamber rate-responsive pacing at 70/min (DDDR-70; n = 250). Maximal tolerated medical therapy for left ventricular dysfunction, including angiotensin-converting enzyme inhibitors and beta-blockers, was prescribed to all patients. MAIN OUTCOME MEASURE: Composite end point of time to death or first hospitalization for congestive heart failure. RESULTS: One-year survival free of the composite end point was 83.9% for patients treated with VVI-40 compared with 73.3% for patients treated with DDDR-70 (relative hazard, 1.61; 95% confidence interval [CI], 1.06-2.44). The components of the composite end point, mortality of 6.5% for VVI-40 vs 10.1% for DDDR-70 (relative hazard, 1.61; 95% CI, 0.84-3.09) and hospitalization for congestive heart failure of 13.3% for VVI-40 vs 22.6% for DDDR-70 (relative hazard, 1.54; 95% CI, 0.97-2.46), also trended in favor of VVI-40 programming. CONCLUSION: For patients with standard indications for ICD therapy, no indication for cardiac pacing, and an LVEF of 40% or less, dual-chamber pacing offers no clinical advantage over ventricular backup pacing and may be detrimental by increasing the combined end point of death or hospitalization for heart failure.

Adrenergic beta-Antagonists↗

Endocardial wave front organization during ventricular fibrillation in humans.

OBJECTIVES: This study was designed to characterize the organization of ventricular fibrillation (VF) on the endocardium of humans. BACKGROUND: Most proposed mechanisms for the maintenance of VF postulate the propagation of a number of activation wave fronts that reenter to maintain the arrhythmia. We tested the hypothesis that, in patients undergoing internal cardioverter-defibrillator implantation, VF consists primarily of a few large wave fronts on the endocardium. METHODS: Electrograms were recorded from a 36-electrode catheter in the left ventricle of 16 patients during VF. Activation times were chosen for a 2-s epoch for each fibrillation episode, and a two-dimensional Kolmogorov-Smirnov test was performed to determine if activation occurred randomly along the catheter over that time interval. The maximum cross-correlation was found for all possible pairs of electrodes on the catheter, and these values were plotted relative to the distance between the two electrodes. An exponential curve was then fit to the data, and a length constant was determined. Activation times were grouped into wave fronts along the catheter, and the lengths of the wave fronts were estimated. RESULTS: The Kolmogorov-Smirnov test showed that activation was not random along the catheter in any of the patients studied. The correlation length determined was 9 +/- 2 cm. The number of wave fronts recorded by the catheter was 9.2 +/- 2.9 wave fronts/s. The length of the pathway of each wave front along the catheter was 6.5 +/- 4.5 cm. CONCLUSIONS: Ventricular fibrillation is well organized on the endocardial surface of humans, consisting primarily of a few large wave fronts on the order of 6 to 9 cm.

Adult↗

Long-term structural failure of coaxial polyurethane implantable cardioverter defibrillator leads.

Transvene models 6936/6966, a coaxial polyurethane ICD lead, may be prone to structural failure. These models comprise 54% of ICD lead failures in the authors' Multicenter Registry database. Because ICD leads perform a vital function, the clinical features, causes, and probability of Transvene 6936/6966 lead failure were determined. The Registry and United States Food and Drug Administration databases were queried for the clinical features and structural causes of the Transvene 6936/6966 lead failure, and a five-center substudy estimated the survival probability for 521 Transvene 6936/6966 implants. The mean time to failure was 4.8 +/- 2.1 years, and the estimated survival at 60 and 84 months after implant were 92% and 84%, respectively. Oversensing was the most common sign of failure (76%), and 24 patients experienced inappropriate shocks. The manufacturer's reports indicated that high voltage coil fracture and 80A polyurethane defects were the predominant causes of lead failure. Transvene models 6936 and 6966 coaxial polyurethane ICD leads are prone to failure over time. Patients who have these leads should be evaluated frequently. Additional studies are needed to identify safe management strategies.

Death, Sudden, Cardiac↗

Frequency of symptomatic atrial fibrillation in patients enrolled in the Atrial Fibrillation Follow-up Investigation of Rhythm Management (AFFIRM) study.

INTRODUCTION: The frequency of symptomatic paroxysmal atrial fibrillation (AF) may identify subsets with different characteristics. Because the approach to AF now is so varied, ranging from drug therapy to surgery and catheter ablation, the frequency of AF may have important therapeutic implications if the frequency identifies subsets with distinguishing features. METHODS AND RESULTS: The Atrial Fibrillation Follow-up Investigation of Rhythm Management (AFFIRM) Study is evaluating patients with AF who are at high risk for stroke. We evaluated the clinical characteristics of the patients in the AFFIRM Study in an attempt to identify features that might distinguish patients with infrequent and frequent AF occurrences. Patients were divided into five groups, based upon the historic frequency of occurrence of AF at the time the patients were enrolled in the study. Although statistically significant differences were present among the groups, no important differences were noted in clinical or echocardiographic characteristics that could differentiate patients with frequent episodes of AF from other patients in the AFFIRM population. CONCLUSION: In a large population of patients with AF at high risk for stroke, individual historic and echocardiographic characteristics failed to distinguish patients based on the frequency of AF. Those with frequent and infrequent AF were similar. Although AF frequency has been suggested as a marker of a focal etiology in young populations with little overt heart disease, it does not seem to be a distinguishing characteristic in older populations at high risk for stroke.