Search PubMed⌕ Search

Biomedical subjects

Andrew Dimitrijevic

Publications and source records attributed to Andrew Dimitrijevic.

8 recordsLinked to original sources

Human electrophysiological examination of buildup of the precedence effect.

Event-related potential correlates of the buildup of precedence effect were examined. Buildup is a type of precedence effect illusion in which perception changes (from hearing two clicks to hearing one click) during a click train. Buildup occurs faster for right-leading than left-leading clicks. Continuous click trains that changed leading sides every 15 clicks were presented. Event-related potential N1 amplitudes became smaller with click train for right-leading only. N1 latency decreased with click trains. Mismatch negativity was seen after lead-lag sides were changed. When the perceived change differed in location (left-to-right), mismatch negativity peaked earlier than when the perceived change differed in location and number of clicks (right-to-left). Results suggest that buildup relates to: N1 refractoriness, event-related potential 'lead domination' and mismatch negativity differences.

Acoustic Stimulation↗

Estimating audiometric thresholds using auditory steady-state responses.

Human auditory steady-state responses (ASSRs) were recorded using stimulus rates of 78-95 Hz in normal young subjects, in elderly subjects with relatively normal hearing, and in elderly subjects with sensorineural hearing impairment. Amplitude-intensity functions calculated relative to actual sensory thresholds (sensation level or SL) showed that amplitudes increased as stimulus intensity increased. In the hearing-impaired subjects this increase was more rapid at intensities just above threshold ("electrophysiological recruitment") than at higher intensities where the increase was similar to that seen in normal subjects. The thresholds in dB SL for recognizing an ASSR and the intersubject variability of these thresholds decreased with increasing recording time and were lower in the hearing impaired compared to the normal subjects. After 9.8 minutes of recording, the average ASSR thresholds (and standard deviations) were 12.6 +/- 8.7 in the normal subjects, 12.4 +/- 11.9 dB in the normal elderly, and 3.6 +/- 13.5 dB SL in the hearing-impaired subjects.

Adult↗

Auditory steady-state responses and word recognition scores in normal-hearing and hearing-impaired adults.

OBJECTIVE: The number of steady-state responses evoked by the independent amplitude and frequency modulation (IAFM) of tones has been related to the ability to discriminate speech sounds as measured by word recognition scores (WRS). In the present study IAFM stimulus parameters were adjusted to resemble the acoustic properties of everyday speech to see how well responses to these speech-modeled stimuli were related to WRS. DESIGN: We separately measured WRS and IAFM responses at a stimulus intensity of 70 dB SPL in three groups of subjects: young normal-hearing, elderly normal-hearing, and elderly hearing-impaired. We used two series of IAFM stimuli, one with modulation frequencies near 40 Hz and the other with modulation frequencies near 80 Hz. The IAFM stimuli, consisting of four carrier frequencies each independently modulated in frequency and amplitude, could evoke up to eight separate responses in one ear. We recorded IAFM responses and WRS measurements in quiet and in the presence of speech-masking noise at 67 dB SPL or 70 dB SPL. We then evaluated the hearing-impaired subjects with and without their hearing aids to see whether an improvement in WRS would be reflected in an increased number of responses to the IAFM stimulus. RESULTS: The correlations between WRS and the number of IAFM responses recognized as significantly different from the background were between 0.70 and 0.81 for the 40 Hz stimuli, between 0.73 and 0.82 for the 80 Hz stimuli, and between 0.76 and 0.85 for the combined assessment of 40 and 80 Hz responses. Response amplitudes at 80 Hz were smaller in the hearing-impaired than in the normal-hearing subjects. Response amplitudes for the 40 Hz stimuli varied with the state of arousal and this effect made it impossible to compare amplitudes across the different groups. Hearing aids increased both the WRS and the number of significant IAFM responses at 40 Hz and 80 Hz. Masking decreased the WRS and the number of significant responses. CONCLUSIONS: IAFM responses are significantly correlated with WRS and may provide an objective tool for examining the brain's ability to process the auditory information needed to perceive speech.

Adult↗

Human auditory steady-state responses.

Steady-state evoked potentials can be recorded from the human scalp in response to auditory stimuli presented at rates between 1 and 200 Hz or by periodic modulations of the amplitude and/or frequency of a continuous tone. Responses can be objectively detected using frequency-based analyses. In waking subjects, the responses are particularly prominent at rates near 40 Hz. Responses evoked by more rapidly presented stimuli are less affected by changes in arousal and can be evoked by multiple simultaneous stimuli without significant loss of amplitude. Response amplitude increases as the depth of modulation or the intensity increases. The phase delay of the response increases as the intensity or the carrier frequency decreases. Auditory steady-state responses are generated throughout the auditory nervous system, with cortical regions contributing more than brainstem generators to responses at lower modulation frequencies. These responses are useful for objectively evaluating auditory thresholds, assessing suprathreshold hearing, and monitoring the state of arousal during anesthesia.

Acoustic Stimulation↗

Auditory steady-state responses to exponential modulation envelopes.

OBJECTIVE: This study examined the steady-state responses evoked by tones modulated with exponential envelopes. The hypothesis was that stimuli with envelopes containing more rapid changes would evoke larger responses. DESIGN: Multiple auditory steady-state responses were recorded simultaneously to eight tonal stimuli, four in each ear. The carrier frequencies of the stimuli ranged from 500 to 6000 Hz and the modulation rates were between 75 and 95 Hz. The modulation envelopes were based on functions using sin' where N was 1, 2, 3, or 4. Setting N to 1 produced the traditional sinusoidal modulation. RESULTS: Exponential envelopes with N greater than 1 produced larger steady-state responses than a sinusoidal envelope. For amplitude-modulation (AM), exponential envelopes increased response amplitudes by 21% at 55 dB pSPL, and by 29% at 35 dB pSPL. The increases were smaller for carrier frequencies of 1500 to 2000 Hz than for lower and higher carrier frequencies. Latencies calculated from phase data increased significantly with increasing N. This was likely caused by the point of maximal envelope-slope shifting later in time as N increased. For frequency modulation (FM), the steady-state responses did not significantly change with changes in the power of the exponential envelopes. CONCLUSIONS: When tones are amplitude-modulated with exponential envelopes based on sin(N), the amplitude and latency of the steady-state response increased significantly with increasing N. Using exponential envelopes with N greater than 1 should considerably shorten the time needed for responses to become significant when using steady-state responses in objective audiometry.

Adult↗

Multiple auditory steady-state responses.

Steady-state responses are evoked potentials that maintain a stable frequency content over time. In the frequency domain, responses to rapidly presented stimuli show a spectrum with peaks at the rate of stimulation and its harmonics. Auditory steady-state responses can be reliably evoked by tones that have been amplitude-modulated at rates between 75 and 110 Hz. These responses show great promise for objective audiometry, because they can be readily recorded in infants and are unaffected by sleep. Responses to multiple tones presented simultaneously can be independently assessed if each tone is modulated at a different modulation frequency. This ability makes it possible to estimate thresholds at several audiometric frequencies in both ears at the same time. Because amplitude-modulated tones are not significantly distorted by free-field speakers or microphones, they can also be used to evaluate the performance of hearing aids. Responses to amplitude and frequency modulation may also become helpful in assessing suprathreshold auditory processes, such as those necessary for speech perception.

Age Factors↗

Estimating the audiogram using multiple auditory steady-state responses.

Multiple auditory steady-state responses were evoked by eight tonal stimuli (four per ear), with each stimulus simultaneously modulated in both amplitude and frequency. The modulation frequencies varied from 80 to 95 Hz and the carrier frequencies were 500, 1000, 2000, and 4000 Hz. For air conduction, the differences between physiologic thresholds for these mixed-modulation (MM) stimuli and behavioral thresholds for pure tones in 31 adult subjects with a sensorineural hearing impairment and 14 adult subjects with normal hearing were 14+/-11, 5+/-9, 5+/-9, and 9+/-10 dB (correlation coefficients .85, .94, .95, and .95) for the 500-, 1000-, 2000-, and 4000-Hz carrier frequencies, respectively. Similar results were obtained in subjects with simulated conductive hearing losses. Responses to stimuli presented through a forehead bone conductor showed physiologic-behavioral threshold differences of 22+/-8, 14+/-5, 5+/-8, and 5+/-10 dB for the 500-, 1000-, 2000-, and 4000-Hz carrier frequencies, respectively. These responses were attenuated by white noise presented concurrently through the bone conductor.

Adult↗

Advantages and caveats when recording steady-state responses to multiple simultaneous stimuli.

This article considers the efficiency of evoked potential audiometry using steady-state responses evoked by multiple simultaneous stimuli with carrier frequencies at 500, 1000, 2000, and 4000 Hz. The general principles of signal-to-noise enhancement through averaging provide a basis for determining the time required to estimate thresholds. The advantage of the multiple-stimulus technique over a single-stimulus approach is less than the ratio of the number of stimuli presented. When testing two ears simultaneously, the advantage is typically that the multiple-stimulus technique is two to three times faster. One factor that increases the time of the multiple-response recording is the relatively small size of responses at 500 and 4000 Hz. Increasing the intensities of the 500- and 4000-Hz stimuli by 10 or 20 dB can enhance their responses without significantly changing the other responses. Using multiple simultaneous stimuli causes small changes in the responses compared with when the responses are evoked by single stimuli. The clearest of these interactions is the attenuation of the responses to low-frequency stimuli in the presence of higher-frequency stimuli. Although these interactions are interesting physiologically, their small size means that they do not lessen the advantages of the multiple-stimulus approach.

Audiometry, Pure-Tone↗