Andrei R Skovoroda

Publications and source records attributed to Andrei R Skovoroda.

5 recordsLinked to original sources

Measuring the nonlinear elastic properties of tissue-like phantoms.

A direct mechanical system simultaneously measuring external force and deformation of samples over a wide dynamic range is used to obtain force-displacement curves of tissue-like phantoms under plain strain deformation. These measurements, covering a wide deformation range, then are used to characterize the nonlinear elastic properties of the phantom materials. The model assumes incompressible media, in which several strain energy potentials are considered. Finite-element analysis is used to evaluate the performance of this material characterization procedure. The procedures developed allow calibration of nonlinear elastic phantoms for elasticity imaging experiments and finite-element simulations.

Adult↗

Prospects for elasticity reconstruction in the heart.

The elastic moduli in anisotropic media can be estimated using either direct mechanical or sound speed measurements. Here we compare moduli in the passive heart estimated with different methods and demonstrate that high-frequency (i.e., ultrasonic) sound speed measurements are inconsistent with static deformations and low-frequency shear wave results. Both tissue fixation and the high-operating frequency of ultrasonic measurements contribute to these discrepancies. Moreover, the precision of ultrasonic sound speed measurements required to estimate elastic moduli describing static deformations of a nearly incompressible anisotropic medium such as the heart appears to be beyond the scope of current methods. We conclude that an incompressible anisotropic elastic model is appropriate for elasticity reconstruction in the heart, in which three independent constants characterize small strain behavior, but four are needed for a fully nonlinear description of finite deformations.

Algorithms↗

Model-based reconstructive elasticity imaging of deep venous thrombosis.

Deep venous thrombosis (DVT) and its sequela, pulmonary embolism, is a significant clinical problem. Once detected, DVT treatment is based on the age of the clot. There are no good noninvasive methods, however, to determine clot age. Previously, we demonstrated that imaging internal mechanical strains can identify and possibly age thrombus in a deep vein. In this study the deformation geometry for DVT elasticity imaging and its effect on Young's modulus estimates is addressed. A model-based reconstruction method is presented to estimate elasticity in which the clot-containing vessel is modeled as a layered cylinder. Compared to an unconstrained approach in reconstructive elasticity imaging, the proposed model-based approach has several advantages: only one component of the strain tensor is used; the minimization procedure is very fast; the method is highly efficient because an analytic solution of the forward elastic problem is used; and the method is not very sensitive to the details of the external load pattern--a characteristic that is important for free-hand, external, surface-applied deformation. The approach was tested theoretically using a numerical model, and experimentally on both tissue-like phantoms and an animal model of DVT. Results suggest that elasticity reconstruction may prove to be a practical adjunct to triplex scanning to detect, diagnose, and stage DVT.

Aging↗

Nonlinear elasticity imaging: theory and phantom study.

In tissue the Young's modulus cannot be assumed constant over a wide deformation range. For example, direct mechanical measurements on human prostate show up to a threefold increase in Young's modulus over a 10% deformation. In conventional elasticity imaging, these effects produce strain-dependent elastic contrast. Ignoring these effects generally leads to suboptimal contrast (stiffer tissues at lower strain are contrasted against softer tissues at higher strain), but measuring the nonlinear behavior results in enhanced tissue differentiation. To demonstrate the methods extracting nonlinear elastic properties, both simulations and measurements were performed on an agar-gelatin phantom. Multiple frames of phase-sensitive ultrasound data are acquired as the phantom is deformed by 12%. All interframe displacement data are brought back to the geometry of the first frame to form a three-dimensional (3-D) data set (depth, lateral, and preload dimensions). Data are fit to a 3-D second order polynomial model for each pixel that adjusts for deformation irregularities. For the phantom geometry and elastic properties considered in this paper, reconstructed frame-to-frame strain images using this model result in improved contrast to noise ratios (CNR) at all preload levels, without any sacrifice in spatial resolution. From the same model, strain hardening at all preload levels can be extracted. This is an independent contrast mechanism. Its maximum CNR occurs at 5.13% preload, and it is a 54% improvement over the best case (preload 10.6%) CNR for frame-to-frame strain reconstruction. Actual phantom measurements confirm the essential features of the simulation. Results show that modeling of the nonlinear elastic behavior has the potential to both increase detectability in elasticity imaging and provide a new independent mechanism for tissue differentiation.

Algorithms↗

An integrated compliant balloon ultrasound catheter for intravascular strain imaging.

An integrated compliant balloon ultrasound catheter was developed to allow greater deformations in strain imaging with intravascular ultrasound. A 64-element circumferential array was placed inside a compliant silicone balloon catheter to capture real-time, phase-sensitive radio frequency (RF) data during deformation experiments. Strains over 40% could be applied to normal arterial wall tissue with intracatheter pressures as low as 200 kPa (2 atm). Strain images of a hard-soft rubber phantom, thrombus, and fibrotic plaque were produced using the integrated balloon ultrasound catheter. Results show that this catheter can apply large deformations at low pressures and image various vascular pathologies ex vivo. Potentially, it can serve as a multifunctional, intravascular therapeutic device to guide angioplasty and stent deployment.

Animals↗