Search PubMed⌕ Search

Biomedical subjects

Andreas Stemmer

Publications and source records attributed to Andreas Stemmer.

7 recordsLinked to original sources

Polymeric, electrically tunable diffraction grating based on artificial muscles.

We demonstrate a low-cost, electrically tunable diffraction grating that is driven by a dielectric elastomer actuator. The angular tuning range of the polymer-based device is up to 118 mrad for the first diffracted order. The achievable grating period change of 32% is an improvement by more than a factor of 150 compared with existing analog tunable diffraction gratings based on hard materials. We show that in combination with a white light source, the presented diffraction grating can be used as a wavelength-adjustable luminous source. Such an illuminant has a potential application in inexpensive color displays that could reproduce all perceivable colors.

Biomimetics↗

High-speed microcontact printing.

We have demonstrated microcontact printing (muCP) of self-assembled monolayers in the millisecond regime. The contact formation and separation of the stamp and substrate was studied with high-speed video recordings. Using high ink concentrations and contact times as short as 1 ms, we printed monolayers of hexadecanethiol on Au, which served as a selective etch resist. High-speed muCP yields defect-free monolayers that are independent of the dimensions of the printed patterns, have high contrast between printed and unprinted areas, and enable perfect reproducibility of prints.

Journal Article↗

Charge patterns as templates for the assembly of layered biomolecular structures.

Electric fields are used to guide the assembly of biomolecules in predefined geometric patterns on solid substrates. Local surface charges serve as templates to selectively position proteins on thin-film polymeric electret layers, thereby creating a basis for site-directed layered assembly of biomolecular structures. Charge patterns are created using the lithographic capabilities of an atomic force microscope, namely by applying voltage pulses between a conductive tip and the sample. Samples consist of a poly(methyl methacrylate) layer on a p-doped silicon support. Subsequently, the sample is developed in a water-in-oil emulsion, consisting of a dispersed aqueous phase containing biotin-modified immunoglobulinG molecules, and a continuous nonpolar, insulating oil phase. The electrostatic fields cause a net force of (di)electrophoretic nature on the droplet, thereby guiding the proteins to the predefined locations. Due to the functionalization of the immunoglobulinG molecules with biotin-groups, these patterns can now be used to initiate the localized layer-by-layer assembly of biomolecules based on the avidin-biotin mechanism. By binding 40 nm sized biotin-labelled beads to the predefined locations via a streptavidin linker, we verify the functionality of the previously deposited immunoglobulinG-biotin. All assembly steps following the initial deposition of the immunoglobulinG from emulsion can conveniently be conducted in aqueous solutions. Results show that pattern definition is maintained after immersion into aqueous solution.

Avidin↗

Electro-osmotic streaming on application of traveling-wave electric fields.

We describe ac electro-osmotic flow of an aqueous electrolyte on application of a traveling-wave electric field. Depending on the frequency of the applied traveling wave, the interaction of the electric double layer charge and the tangential electric field leads to fluid flow in the direction of the traveling wave. We have derived two theoretical models that describe this flow as a function of the amplitude of the applied electric potential, the signal frequency, and the material properties of the system. The first is based on a capacitative model and is limited to frequencies much lower than the double layer relaxation frequency. The second is an analytical solution of the electrokinetic equations and is also valid at higher frequencies. We provide experimental evidence that streaming takes place on application of a traveling wave of potential by tracing the movements of fluorescent latex beads over a spiral electrode structure. Streaming takes place at applied potentials low enough for the method to be easily integrated into lab-on-a-chip devices.

Journal Article↗

Velocity dependent friction laws in contact mode atomic force microscopy.

Friction forces in the tip-sample contact govern the dynamics of contact mode atomic force microscopy. In ambient conditions typical contact radii between tip and sample are in the order of a few nanometers. In order to account for the large interaction area the dynamics of contact mode atomic force microscope (AFM) is investigated under the assumption of a multi-asperity contact interface between tip and sample. Thus, the kinetic friction force between tip and sample is the product of the real contact area between both solids and the interfacial shear strength. The velocity strengthening of the lateral force is modeled assuming a logarithmic relationship between shear-strength and velocity. Numerical simulations of the system dynamics with this empirical model show the existence of two different regimes in contact mode AFM: steady sliding and stick-slip where the tip undergoes periodically stiction and kinetic friction. The state of the system depends on the scan velocity as well as on the velocity dependence of the interfacial friction force between tip and sample. Already small viscous damping contributions in the tip-sample contact are sufficient to suppress stick-slip oscillations.

Journal Article↗

Development of preparation methods for and insights obtained from atomic force microscopy of fluid spaces in cortical bone.

Several preparation methods were developed to investigate the dimensions and surface structure of fluid spaces within cortical bone, using atomic force microscopy (AFM). Of special interest was the morphology of the lacunocanalicular system, which serves as a conduit between osteocytes encased in bone tissue, the intramedullary cavity, blood vessels running through the bone, and the periosteal surface of bone. Fracture and the removal of either the mineral or the organic component is a method by which each component can be investigated at a very high resolution in situ. Although fractured bone was too rough to image details of the lacunocanalicular system, post-treatment with ethylene diamine tetraacetic acid (EDTA) or papain allowed for investigation of the collagen matrix or the mineral crystals of bone, respectively. Cut and polished bone was smooth enough for identifying the lacunae of bone using AFM, but unambiguous differentiation between the canaliculi and cracks in the bone surface was not possible. However, when the lacunocanalicular system was filled with polymethylmethacrylate (PMMA), it was possible to image casts of the lacunocanalicular system by selectively etching away the surrounding bone matrix. Using this method, we identified individual canaliculi and measured their dimensions. Furthermore, by carefully etching away the bone matrix in successive etches, it was shown that the wall structure of the canaliculus is dominated by collagen fibrils. These observations have important implications for fluid flow in bone.

Animals↗

Guiding self-assembly with the tip of an atomic force microscope.

We report the guided self-assembly of nanoparticles to geometrically well-defined charge patterns written on a dielectric surface with the conductive tip of an atomic force microscope (AFM). Charges are deposited in 30-90-nm thick fluorocarbon layers by applying voltage pulses to the conductive AFM tip. The samples are being developed by dipping them into an organic suspension of silica nanoparticles. Coulomb forces draw the nanoparticles to the charge patterns. With this simple process, we achieve a resolution of about 800 nm.

Journal Article↗