Search PubMed⌕ Search

Biomedical subjects

Andreas P Dahlin

Publications and source records attributed to Andreas P Dahlin.

3 recordsLinked to original sources

A simplified multidimensional approach for analysis of complex biological samples: on-line LC-CE-MS.

Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices.

Animals↗

Sample pretreatment on a microchip with an integrated electrospray emitter.

This study presents a microbead-packed PDMS microchip with an integrated electrospray emitter for sample pretreatment prior to sheathless ESI-MS. We prove the concept of analytical functions integrated onto a cm-sized area of a single bulk material. The microchip consists of two PDMS substrates replicated from SU-8 fabricated silicon wafer masters, bonded together after oxidation by corona discharge treatment. The channel within the microchip contains a grid structure that was used to trap 5 microm hypercross-linked polystyrene beads. The beads acted as a medium for sample desalting and enrichment. Electrical contact for the sheathless ESI process was achieved by coating the integrated emitter with conductive graphite powder after applying a thin layer of PDMS as glue. The coating as well as the bond of the PDMS structures showed excellent durability. A continuous spray was obtained from the microchip for over 800 h in a long-term electrospray stability experiment. Desalting and enrichment of neuropeptides from a physiological salt solution was successful by loading the sample onto the packed beads, followed by a washing and an eluting step. The results were obtained and evaluated using a TOF MS. An LOD of approximately 20 fmol (loaded onto the beads) for angiotensin II was obtained from a sample of neuropeptides dissolved in physiological salt solution.

Dimethylpolysiloxanes↗

Poly(dimethylsiloxane)-based microchip for two-dimensional solid-phase extraction-capillary electrophoresis with an integrated electrospray emitter tip.

A microchip in poly(dimethylsiloxane) (PDMS) for in-line solid-phase extraction-capillary electrophoresis-electrospray ionization-time-of-flight mass spectrometry (SPE-CE-ESI-TOF-MS) has been developed and evaluated. The chip was fabricated in a novel one-step procedure where mixed PDMS was cast over steel wires in a mold. The removed wires defined 50-microm cylindrical channels. Fused-silica capillaries were inserted into the structure in a tight fit connection. The inner walls of the inserted fused-silica capillaries and the PDMS microchip channels were modified with a positively charged polymer, PolyE-323. The chip was fabricated in a two-level cross design. The channel at the lower level was packed with 5-microm hyper-cross-linked polystyrene beads acting as a SPE medium used for desalting. The upper level channel acted as a CE channel and ended in an integrated emitter tip coated with conducting graphite powder to facilitate the electrical contact for sheathless ESI. An overpressure continuously provided fresh CE electrolyte independently of the flows in the different levels. Further studies were carried out in order to investigate the electrophoretic and flow rate properties of the chip. Finally, six-peptide mixtures, in different concentrations, dissolved in physiological salt solution was injected, desalted, separated, and sprayed into the mass spectrometer for analysis with a limit of detection in femtomole levels.

Amino Acid Sequence↗