Search PubMed⌕ Search

Biomedical subjects

Andrea Natale

Publications and source records attributed to Andrea Natale.

At least 91 records · Page 5Linked to original sources

Ventricular rate control by selective vagal stimulation is superior to rhythm regularization by atrioventricular nodal ablation and pacing during atrial fibrillation.

BACKGROUND: Selective atrioventricular nodal (AVN) vagal stimulation (AVN-VS) has emerged as a novel strategy for ventricular rate (VR) control in atrial fibrillation (AF). Although AVN-VS preserves the physiological ventricular activation sequence, the resulting rate is slow but irregular. In contrast, AVN ablation with pacemaker implantation produces retrograde activation (starting at the apex), with regular ventricular rhythm. We tested the hypothesis that, at comparable levels of VR slowing, AVN-VS provides hemodynamic benefits similar to those of ablation with pacemaker implantation. METHODS AND RESULTS: AVN-VS was delivered to the epicardial fat pad that projects parasympathetic nerve fibers to the AVN in 12 dogs during AF. A computer-controlled algorithm adjusted AVN-VS beat by beat to achieve a mean ventricular RR interval of 75%, 100%, 125%, or 150% of spontaneous sinus cycle length. The AVN was then ablated, and the right ventricular (RV) apex was paced either irregularly (i-RVP) using the RR intervals collected during AVN-VS or regularly (r-RVP) at the corresponding mean RR. The results indicated that all 3 strategies improved hemodynamics compared with AF. However, AVN-VS resulted in significantly better responses than either r-RVP or i-RVP. i-RVP resulted in worse hemodynamic responses than r-RVP. The differences among these modes became less significant when mean VR was slowed to 150% of sinus cycle length. CONCLUSIONS: AVN-VS can produce graded slowing of the VR during AF without destroying the AVN. It was hemodynamically superior to AVN ablation with either r-RVP or i-RVP, indicating that the benefits of preserving the physiological antegrade ventricular activation sequence outweigh the detrimental effect of irregularity.

Animals↗

Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies.

OBJECTIVES: We conducted this study to compare the efficacy and safety of different catheter ablation technologies and of distal versus ostial pulmonary veins (PV) isolation using the circular mapping technique. BACKGROUND: Electrical isolation of the PVs in patients with atrial fibrillation (AF) remains a technical challenge. METHODS: Two hundred eleven patients (163 men; mean age 53 +/- 11 years) with symptomatic AF were included in this study. In the first 21 patients (group 1), distal isolation (> or = 5 mm from the ostium) was achieved targeting veins triggering AF. In the remaining 190 patients (group 2), ostial isolation of all PVs was performed using 4-mm tip (47 patients), 8-mm tip (21 patients), or cooled-tip (122 patients) ablation catheters. RESULTS: Distal isolation was able to eliminate premature atrial contractions (PACs) and AF in six of 21 patients (29%) and 10 of 34 PVs. After a mean follow-up time of 6 +/- 4 months, no patients treated with the 8-mm tip catheter experienced recurrence of AF, whereas 21% (10 of 47 patients) and 15% (18 of 122 patients) of the patients ablated with the 4-mm tip and the cooled-tip ablation catheters experienced recurrence of AF after a mean follow-up of 10 +/- 3 and 4 +/- 2 months, respectively. Significant complications including stroke, tamponade, and severe stenosis occurred in 3.5% (8/211) of patients. CONCLUSIONS: Catheter technologies designed to achieve better lesion size appeared to have a positive impact on procedure time, fluoroscopy time, number of lesions, and overall efficacy. Although distal isolation can be achieved with fewer lesions, ostial isolation is required in the majority of patients to eliminate arrhythmogenic PACs and AF.

Adult↗

Three-dimensional nonfluoroscopic mapping and ablation of inappropriate sinus tachycardia. Procedural strategies and long-term outcome.

OBJECTIVES: We conducted this study to assess long-term results of three-dimensional (3-D) mapping-guided radiofrequency ablation (RFA) of inappropriate sinus tachycardia (IST). Change in activation after the administration of esmolol was also assessed and compared to the shift documented with successful sinus node (SN) modification. BACKGROUND: The long-term results after RFA of IST have been reported to vary between 27% and 66%. METHODS: Thirty-nine patients (35 women, mean age 31 +/- 9 years) with debilitating IST were included in the study. The area around the earliest site of activation recorded using the 3-D mapping system was targeted for ablation. The shift in the earliest activation site after administration of esmolol was compared with the shift after RFA. RESULTS: The heart rate at rest and in drug-free state ranged between 95 and 125 beats/min (mean 99 +/- 14 beats/min). Sinus node was successfully modified in all patients. Following ablation, the mean heart rate dropped to 72 +/- 8 beats/min, p < 0.01. The extent of the 3-D shift in caudal activation along the crista terminalis was more pronounced after RFA than during esmolol administration (23 +/- 11 mm vs. 7 +/- 5 mm, respectively, p < 0.05). No patient required pacemaker implantation after a mean follow-up time of 32 +/- 9 months; 21% of patients experienced recurrence of IST and were successfully re-ablated. CONCLUSIONS: Three-dimensional electroanatomical mapping seems to facilitate and improve the ablation results of IST. The difference in caudal shift seen after esmolol administration and following SN modification suggests that adrenergic hypersensitivity is not the only mechanism responsible for the inappropriate behavior of the SN.

Adult↗

Human chorionic gonadotropin patterns after a single dose of methotrexate for ectopic pregnancy.

OBJECTIVE: The great variability in human chorionic gonadotropin (HCG) levels after a single dose of methotrexate (MTX) for ectopic pregnancy makes it difficult to predict treatment failure. We describe different patterns of HCG levels. STUDY DESIGN: Fifty patients were injected i.m. with 50mg/m(2) of MTX for an ectopic pregnancy. Venous blood samples for HCG detection were obtained on the day of treatment (day 0), day 3 and day 7 and weekly until values were undetectable. Patients were classified as: group 1, persistent pathology (n=11); group 2, complete resolution with a decrease of HCG levels at day 3 (n=30); group 3, complete resolution after a rise of HCG values at day 3 (n=9). Statistical analysis was performed using the Mann-Whitney non-parametric test with 95% confidence intervals. RESULTS: Values of day 0 were similar for all the groups. HCG levels of group 3 decreased rapidly after day 3 and at day 7 they were significantly different from levels of group 1. Differences in HCG levels between groups 2 and 3 became indistinguishable from day 21. CONCLUSION: The observation of patients undergoing resolution after an initial increase of HCG levels justify an expectant management for 1 week in clinically stable patients. The strategy to separate HCG curves in patients undergoing resolution may shed light on the different clinical responses to therapy for ectopic pregnancies. However, the phenomenon of the immediate rise of HCG should be better investigated.

Abortifacient Agents, Nonsteroidal↗

Ablation of atrial fibrillation.

Associated with significant morbidity and mortality, atrial fibrillation is one of the most common cardiac rhythm disorders. Cure of this arrhythmia has been elusive over the years, despite development of different antiarrhythmic drugs and advances in the understanding of its pathophysiology. Initial experience with catheter ablation procedures based on the creation of linear lesions in both atria has been disappointing, but has led to the key observation that focal triggers localized in the pulmonary veins are responsible for initiation of atrial fibrillation, and thus are suitable targets for catheter ablation. With advances in technology and larger experience, it has become clear that electrical isolation of all four pulmonary veins from the left atrium provides the higher cure rates. However, the procedure is still operator dependent and is associated with a small but significant risk of pulmonary vein stenosis. Further simplification of the isolation techniques and refinement in the catheter design will allow more widespread use of this procedure and higher success rate.

Atrial Fibrillation↗

Evaluation and management of ventricular outflow tract tachycardias.

Ventricular tachycardia (VT) arising from the right or left ventricular outflow tract (OT) is a recognized arrhythmia in individuals with structurally normal hearts. Treatment options for OTVT include medications, ablation and, rarely, an implantable cardioverter defibrillator (ICD). In the past few years ablation techniques have developed to the point where most OTVTs can be successfully ablated. However, a percentage of cases have remained where ablation is unsuccessful. Some of these cases may represent an epicardial focus of the VT. Several approaches to epicardial VT ablation have been described. We recently described a LVOT-VT variant, which may be epicardial in nature, in a group of patients in whom prior ablation attempts had failed. A trans-aortic ablation approach to outflow tract VT was successful in these patients.

Anti-Arrhythmia Agents↗

Ablation of focal atrial fibrillation.

In the past decades management of atrial fibrillation (AF) has been based mainly on drug therapy. New insights into the pathophysiology of AF initiation and maintenance have provided the background for the design of catheter based procedures. The crucial role of the pulmonary veins (PVs) as triggers of AF paved the way for successful mapping and ablation. Electrical isolation of all PVs using the circular mapping approach has been shown to be an effective procedure, with reported success rates around 70 to 80% in most series. Intracardiac echocardiography is a very helpful adjunctive tool to facilitate correct positioning of the circular catheter at the PV-left atrial junction, as well as to monitor energy delivery and assist transseptal left atrial access. PV stenosis is a potential serious complication, occurring in around 2% of cases. It presents mainly with respiratory symptoms, although it is frequently asymptomatic. Spiral computed tomography is a reliable non-invasive method for imaging the PVs and can be used to screen patients for PV stenosis after radiofrequency ablation. In symptomatic patients, PV dilatation and stenting is the preferred treatment approach. The possibility of curing AF represents a major breakthrough in invasive cardiac electrophysiology. Isolation of all PVs is a very solid endpoint for successful ablation and should be pursued in all patients. It seems to be associated with high success rates over long term follow-up. Future refinements in catheter technology should provide simpler and faster procedures and render catheter ablation of AF more widespread and accepted.

Atrial Fibrillation↗

Matching approved "nondedicated" hardware to obtain biventricular pacing and defibrillation: feasibility and troubleshooting.

Biventricular ICDs may offer increased benefit for patients with severe congestive heart failure and ventricular arrhythmia. Currently there are no approved dedicated biventricular ICDs available. Twenty-one consecutive patients who had approved nondedicated hardware implanted for biventricular pacing and defibrillation were included in this study. All device therapies were evaluated using stored electrograms. During mean follow-up at 13 +/- 7 months, 8 (36%) patients had inappropriate shocks. Ventricular fibrillation therapy was delivered for slow ventricular tachycardia because of double counting in two patients. In one patient, AV nodal reentrant tachycardia below detection rate cut off triggered device therapy because of ventricular double counting. Sinus tachycardia or premature atrial contraction initiating AV conduction and ventricular double counting resulted in shocks in five patients. The number of shocks per patient ranged from 1 to 64. Two patients required transient disconnection of the LV lead and subsequent ICD generator replacement for premature battery depletion. Two patients required AV junction ablation and three needed slow pathway ablation. Two patients were treated by upgrading to a device that was capable of a higher atrial tracking rate. The patients with impaired AV conduction or constant ventricular pacing did not have inappropriate therapy for sinus tachycardia or supraventricular arrhythmia. Use of conventional nondedicated hardware for biventricular pacer/defibrillator is feasible but should be considered only in patients with poor AV node function or less likely to require antitachycardic therapy, to avoid ICD double counting of ventricular sensed events and consequent high incidence of inappropriate therapies.

Adult↗

Simultaneous epicardial and endocardial mapping of a left-sided posteroseptal accessory pathway associated with a large coronary sinus diverticulum: successful ablation by transection of the diverticulum's neck.

Transcutaneous pericardial instrumentation in a patient with a left-sided posteroseptal accessory pathway associated with a large coronary sinus diverticulum was performed after three previous unsuccessful ablations. The earliest ventricular activation site was recorded epicardially using a catheterin the pericardial space, but energy delivery at this site was not possible due to high impedances. Intravascular linear lesions transecting the neck of the large coronary sinus diverticulum using the pericardial catheter as a target allowed successful radiofrequency catheter ablation of the accessory pathway. This case outlines potential problems with ablations in the pericardial space and provides an alternative solution that can spare patients from open surgical procedures.

Catheter Ablation↗

Nonexcitatory stimulus delivery improves left ventricular function in hearts with left bundle branch block.

INTRODUCTION: Preliminary data in a heart failure animal model and isolated muscle preparation have suggested that nonexcitatory stimulation (NES) improves left ventricular (LV) function. METHODS AND RESULTS: We compared biventricular (BV) pacing with NES in an animal model with left bundle branch block (LBBB). The left bundle branch (LBB) was ablated in eight normal heart pigs and led to >50% increase in QRS duration (mean 100 +/- 15 msec). End-diastolic LV pressure, end-systolic LV pressure, LV pressure (LV dP/dtmax), aortic pulse pressure, and LV ejection fraction were measured before pre-LBB ablation and compared with post-LBB ablation (AAI pacing), BV pacing, NES delivery, and BV+NES. Moreover, to evaluate LV diastolic function, we measured the early (E wave) and late flows (A wave) through the mitral valve using spectral Doppler. Compared with post-LBB ablation, NES led to a significant increase in LV dP/dtmax (1,047 +/- 224 mmHg/sec vs 897 +/- 116 mmHg/sec; P < 0.05), LV ejection fraction (64% +/- 18% vs 49% +/- 17%; P < 0.05), and aortic pulse pressure (18 +/- 3.6 mmHg vs 16 +/- 2.8 mmHg; P < 0.05). Moreover, improvement in LV hemodynamic parameters was significantly higher during NES delivery when compared with BV pacing. No significant changes in E wave, A wave, and E/A were recorded during NES, NES+BV, and BV pacing. CONCLUSION: Our preliminary data demonstrate that NES is superior to BV pacing in improving LV function in an animal model with LBBB. Moreover, we demonstrated that NES does not affect transmitral valve flow and subsequently LV diastolic function.

Animals↗

Circumferential ultrasound ablation for pulmonary vein isolation: analysis of acute and chronic failures.

INTRODUCTION: In patients undergoing circumferential isolation of the pulmonary veins with an ultrasound ablation system, we analyzed the temperatures achieved while delivering circumferential ostial lesions in the pulmonary veins. We also reviewed the angiograms obtained during the procedure and identified anatomic variants that could be responsible for ineffective lesion formation. METHODS AND RESULTS: During the early clinical use in 33 patients, a total of 85 veins were ablated. A mean of 16.9 +/- 12.3 ablations were delivered per patient, and a mean of 6.7 ablations per vein were applied. Entry block was assessed by placing a deflectable octapolar or a circular catheter in the vein. The following anatomic characteristics and technical limitations were identified as possible reasons for ineffective energy delivery: (1) funnel-shaped ostium; (2) ostial diameter larger than the balloon diameter; (3) inability to deliver the catheter to the right inferior or other vein ostia; (4) ostial instability; (5) early branching of the vein; and (6) eccentric position of the ultrasound transducer in the vein. In patients with recurrence of atrial fibrillation, 40% of the ostial lesions reached a temperature >60 degrees C. However, in patients cured by the ablation, 64% of the ostial lesions reached a temperature >60 degrees C (P < 0.06). At least 12 of the 20 chronic recurrences could have been related to technical limitations of the first system. Duration of atrial fibrillation and eccentric deployment of the ultrasound transducer were more frequent in patients with recurrence of arrhythmias at follow-up. CONCLUSION: Ostial anatomy of the veins may affect delivery of ultrasound energy to achieve circumferential lesions. Energy delivery at the ostium with a temperature > 60 degrees C may be important to maximize success. Reconfiguration of the system to overcome the shortcomings identified in the initial experience could increase its performance.

Adult↗

Use of intracardiac echocardiography for prediction of chronic pulmonary vein stenosis after ablation of atrial fibrillation.

INTRODUCTION: Measurements of pulmonary vein (PV) flow with intracardiac echocardiography (ICE) immediately before and after PV isolation may be a useful method for predicting which patients will develop chronic PV stenosis. METHODS AND RESULTS: We assessed preablation and postablation flows in each of the four PVs using a phase-array ICE catheter in 95 patients (mean age 52 +/- 13) undergoing atrial fibrillation ablation. The ostium of each of the PVs was defined using angiography, electrical mapping, and ICE imaging. Ostial electrical isolation of all PVs was achieved using a 4-mm cooled-tip radiofrequency ablation catheter. Change in PV flow, when present, was examined as both an absolute value and as a percentage of the baseline flow. All patients underwent spiral computed tomography (CT) scans of the PVs 3 months after the procedure for detection of stenosis. The average preablation diastolic flows for the left superior, left inferior, right superior, and right inferior veins were 0.56, 0.54, 0.47, and 0.45 m/sec, respectively. These values increased to 0.74, 0.67, 0.58, and 0.59 m/sec postablation (P < 0.001). Of 380 PVs ablated, the CT scans revealed 2 (1%) with severe (>70%) stenosis, 13 (3%) with moderate (51%-70%) stenosis, and 62 (16%) with mild (< or = 50%) stenosis. The r value between flow and stenosis was only 0.09 (P = NS). CONCLUSION: Acute changes in PV flow immediately after ostial PV isolation do not appear to be a strong predictor of chronic PV stenosis.

Adult↗

Ventricular fibrillation: ablation of a trigger?

We report the case of a patient with recurrent ventricular fibrillation (VF) and no evidence of structural heart disease. VF was consistently initiated by a relatively early-coupled premature ventricular contraction with identical morphology on each occasion. Treatment with antiarrhythmic agents failed to suppress the arrhythmia. Electrophysiologic testing showed high-frequency potential at the earliest activation site, and radiofrequency ablation resulted in abolition of the ventricular ectopy with no further VF recurrence. Suppression of VF arising from focal triggers in patients with frequent ventricular ectopy and normal heart can be achieved with catheter ablation, but further studies are needed to evaluate the prevalence of such a mechanism.

Adult↗

Pulmonary vein firing triggering atrial fibrillation after open heart surgery.

We report the case of a 44-year-old woman with obstructive hypertrophic cardiomyopathy without history of prior arrhythmias who underwent surgical myectomy. She developed symptomatic postoperative atrial fibrillation (AF) that was refractory to antiarrhythmic therapy and could not be adequately rate controlled. AF always was preceded by short and fast runs of atrial tachycardia. In the electrophysiology laboratory, this arrhythmia appeared to originate from the right superior pulmonary vein and conducted with variable degrees of exit block. Pulmonary vein isolation guided by circular mapping was performed, and no further episodes of either atrial tachycardia or AF were noted. This case highlights the potential role of the pulmonary veins in the pathophysiology of postoperative AF.

Adult↗