Search PubMed⌕ Search

Biomedical subjects

Andrea Laghi

Publications and source records attributed to Andrea Laghi.

At least 19 recordsLinked to original sources

Clinical management of hepatic malignancies: ferucarbotran-enhanced magnetic resonance imaging versus contrast-enhanced spiral computed tomography.

This study compares ferucarbotran-enhanced magnetic resonance (MR) imaging with spiral computed tomography (CT) in the clinical management of patients with suspected hepatic malignancy. One hundred fifty-nine patients with suspected liver malignancy were included in a prospective, multicenter, phase IIIB clinical trial. Patients were examined with baseline plus contrast-enhanced spiral CT and with baseline plus ferucarbotran-enhanced MR imaging. For each patient, four maps of liver lesions were constructed by a trusted blind party on the basis of (a) baseline plus contrast-enhanced spiral CT, (b) baseline MR imaging, (c) baseline plus ferucarbotran-enhanced MR imaging, and (d) final diagnosis. Three blinded experts evaluated the treatment options for each map. The concordance of the treatment choice based on imaging with the treatment choice based on final diagnosis was verified. The final therapeutic decision was radical therapy for 85 patients, palliative therapy for 49 patients, and no treatment for 25 patients who had a final diagnosis of benign lesion. Proper treatment allocation was achieved in 121 (76%) of 159 patients when the evaluation was based on liver maps obtained from spiral CT, in 97 (61%) of 159 patients when the evaluation was based on liver maps obtained from baseline MR imaging, and in 136 (85%) of 159 patients when the evaluation was based on liver maps obtained from baseline plus ferucarbotran-enhanced MR imaging. MR imaging with ferucabotran was significantly superior to spiral CT for correct treatment allocation (P = 0.0167). Ferucarbotran-enhanced MR imaging is superior to spiral CT in clinical management of patients with suspected hepatic malignancy.

Adult↗

Small bowel.

MR imaging, using modern equipment and a rigorous technical approach, can offer detailed morphologic information and functional data on the small bowel. The optimal study technique is debatable, although the oral administration of contrast material as a first-line approach is less expensive, faster, easier to perform, and better tolerated by patients. MR enteroclysis might be reserved for selected cases as a second-line study. The major clinical indication is the evaluation of patients who have suspected or known Crohn's disease. The absence of ionizing radiation, considering the young age of most of the patients and the frequency of the examinations, is an important advantage over other techniques (radiograph and CT enteroclysis).

Contrast Media↗

Hepatocellular carcinoma: role of unenhanced and delayed phase multi-detector row helical CT in patients with cirrhosis.

PURPOSE: To determine, by using multi-detector row helical computed tomography (CT), the added value of obtaining unenhanced and delayed phase scans in addition to biphasic (hepatic arterial and portal venous phases) scans in the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis. MATERIALS AND METHODS: Local ethical committee approval and patient consent were obtained. One hundred ninety-five patients (129 men, 66 women; mean age, 61 years; age range, 39-78 years) with 250 HCCs underwent multi-detector row helical CT of the liver. A quadruple-phase protocol that included unenhanced, hepatic arterial, portal venous, and delayed phases was performed. Analysis of images from hepatic arterial and portal venous phases combined, hepatic arterial and portal venous phases with the unenhanced phase, hepatic arterial and portal venous phases with the delayed phase, and all phases combined was performed separately by three independent radiologists. Relative sensitivity, positive predictive value, and area under the receiver operating characteristic curve (A(z)) were calculated for each reading session. RESULTS: Mean sensitivity and positive predictive values, respectively, for HCC detection were 88.8% (666 of 750 readings) and 97.8% (666 of 681 readings) for the combined hepatic arterial and portal venous phases, 89.2% (669 of 750 readings) and 97.8% (669 of 684 readings) for hepatic arterial and portal venous phases with the unenhanced phase, 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for hepatic arterial and portal venous phases with the delayed phase, and 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for all four phases combined. The reading sessions in which delayed phase images were available for interpretation showed significantly (P < .05) superior sensitivity and A(z) values. CONCLUSION: Unenhanced phase images are not effective for HCC detection. Because of the significant increase in HCC detection, a delayed phase can be a useful adjunct to biphasic CT in patients at risk for developing HCC.

Adult↗

Contrast-enhanced sonography with SonoVue: enhancement patterns of benign focal liver lesions and correlation with dynamic gadobenate dimeglumine-enhanced MRI.

OBJECTIVE: Contrast-enhanced real-time low-mechanical-index sonography is a new diagnostic technique for the assessment of macro- and microcirculation. The purpose of our article is to describe contrast-enhancement patterns of different benign focal liver lesions using the second-generation contrast agent SonoVue and to compare these findings with those of gadobenate dimeglumine-enhanced MRI. CONCLUSION: SonoVue-enhanced real-time low-mechanical-index sonography provides specific contrast-enhancement patterns of different benign focal liver lesions, allowing accurate characterization. Findings on SonoVue-enhanced sonography correlate well with those obtained on gadobenate dimeglumine-enhanced MRI.

Adult↗

Virtual colonoscopy.

Explore the source record for details and available documents.

Colonography, Computed Tomographic↗

Computed tomographic colonography without cathartic preparation for the detection of colorectal polyps.

BACKGROUND AND AIMS: We prospectively compared the performance of low-dose multidetector computed tomographic colonography (CTC) without cathartic preparation with that of colonoscopy for the detection of colorectal polyps. METHODS: A total of 203 patients underwent low-dose CTC without cathartic preparation followed by colonoscopy. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. No subtraction of tagged feces was performed. Colonoscopy was performed 3-7 days after CTC. Three readers interpreted the CTC examinations separately and independently using a primary 2-dimensional approach using multiplanar reconstructions and 3-dimensional images for further characterization. Colonoscopy with segmental unblinding was used as reference standard. The sensitivity of CTC was calculated both on a per-polyp and a per-patient basis. For the latter, specificity, positive predictive values, and negative predictive values were also calculated. RESULTS: CTC had an average sensitivity of 95.5% (95% confidence interval [CI], 92.1%-99%) for the identification of colorectal polyps > or =8 mm. With regard to per-patient analysis, CTC yielded an average sensitivity of 89.9% (95% CI, 86%-93.7%), an average specificity of 92.2% (95% CI, 89.5%-94.9%), an average positive predictive value of 88% (95% CI, 83.3%-91.5%), and an average negative predictive value of 93.5% (95% CI, 90.9%-96%). Interobserver agreement was high on a per-polyp basis (kappa statistic range, .61-.74) and high to excellent on a per-patient basis (kappa statistic range, .79-.91). CONCLUSIONS: Low-dose multidetector CTC without cathartic preparation compares favorably with colonoscopy for the detection of colorectal polyps.

Adult↗

Decrease of signal intensity of myometrium and cervical stroma after ultrasmall superparamagnetic iron oxide (USPIO) particles administration: an MR finding with potential benefits in T staging of uterine neoplasms.

OBJECTIVES: Following the empiric observation of a significant decrease of signal intensity of both myometrium and cervical stroma on ultrasmall superparamagnetic iron oxide (USPIO)-enhanced images, the aim of our study was to evaluate whether USPIO-enhanced T2*-weighted gradient echo (GRE) images might provide any potential advantage on T-staging of uterine malignancies having surgery and histology as standard of reference MATERIALS AND METHODS: Seventeen female patients with known uterine malignancies underwent magnetic resonance (MR) imaging before and 24 hours after the intravenous administration of the USPIO agent. Imaging protocol included proton density-weighted turbo spin echo and T2*-weighted GRE sequences. Each patient underwent surgery within 14 days from the first MR examination, and histologic confirmation of tumor T-stage was obtained. Quantitative (calculation of signal-to-noise and contrast-to-noise ratios) and qualitative (visual assessment of T staging) analyses were performed on unenhanced and USPIO-enhanced images. RESULTS: Quantitative analysis showed a significantly lower (P < 0.05) signal-to-noise ratio of myometrium and cervical stroma on USPIO-enhanced compared with unenhanced images. In 15 of 17 patients (88.2%), the contrast-to-noise ratio between tumor and myometrium and between tumor and cervical stroma was higher on USPIO-enhanced compared with unenhanced images (P < 0.001). Qualitative analysis demonstrated that the GRE T2* USPIO-enhanced MR offers a better definition of the depth of tumor infiltration rather than the unenhanced GRE T2* images. CONCLUSION: The decrease of signal intensity of myometrium and cervical stroma on T2*-weighted GRE images after the intravenous administration of USPIO should be considered a constant and physiologic finding that improves tumor conspicuity in the majority of the cases, allowing more accurate T-staging of neoplastic lesions.

Adult↗

Infrarenal aortic and lower-extremity arterial disease: diagnostic performance of multi-detector row CT angiography.

PURPOSE: To compare multi-detector row spiral computed tomographic (CT) angiography with digital subtraction angiography (DSA) in evaluation of the infrarenal aorta and lower-extremity arterial system. MATERIALS AND METHODS: Fifty patients with peripheral arterial occlusive disease were evaluated with multi-detector row CT angiography and DSA. Arteries depicted at CT angiography and DSA were graded separately for degree of stenosis as 23 anatomic segments (infrarenal aorta, right and left common iliac artery, internal iliac artery, external iliac artery, common femoral artery, superficial femoral artery, deep femoral artery, popliteal artery, anterior tibial artery, tibioperoneal trunk, posterior tibial artery, and peroneal artery). Grades included the following: 1, normal patency; 2, moderate (< or =50%) stenosis; 3, focal severe (>50%) stenosis; 4, multiple severe stenoses; and 5, occlusion. Three readers independently interpreted the images, and statistical analysis was performed. The results of image interpretation were evaluated for strength of agreement by using Cohen kappa statistics. On the basis of consensus readings, sensitivity, specificity, and accuracy for detection of stenotic lesions were calculated, with findings at DSA used as the reference standard. RESULTS: Substantial to almost perfect interobserver agreement was achieved in all cases. At DSA, 349 diseased segments were found among the 1,137 segments evaluated. Sensitivity, specificity, and accuracy, based on a consensus reading of multi-detector row CT angiograms, were 96%, 93%, and 94%, respectively. A statistically significant difference (P <.05) between DSA and multi-detector row CT angiography was present only in arteries graded 1 or 2. Interobserver agreement was almost perfect among the three readers for treatment recommendations based on findings at CT angiography and DSA. CONCLUSION: Multi-detector row CT angiography appears consistent and accurate in the assessment of patients with peripheral arterial occlusive disease.

Adult↗

Focal liver lesions in the cirrhotic patient: multislice spiral CT evaluation.

Imaging of the cirrhotic patient is a very difficult task due to the several morphologic and structural alterations that occur in the hepatic parenchyma. The presence of areas of fibrosis and regenerative nodules, often associated with haemodynamic alterations due to the portal hypertension, can make the identification of hepatocellular carcinoma very difficult or, in many cases, simulate the presence of tumour. Despite the use of state-of-the-art equipment and optimised study protocols, computed tomography (CT) has poor sensitivity for the detection of hepatocellular carcinoma. The present article illustrates the spiral CT findings that most often can be found in the evaluation of cirrhotic patients. In particular, the authors illustrate the CT patterns of regenerative nodules, dysplastic nodules, hepatocellular carcinomas and of all lesions that may mimic hepatocellular carcinoma.

Carcinoma, Hepatocellular↗

Hepatocellular carcinoma: detection with triple-phase multi-detector row helical CT in patients with chronic hepatitis.

PURPOSE: To evaluate whether the use of two arterial phase image acquisition series, when combined with portal venous phase imaging at multi-detector row helical computed tomography (CT), would be superior enough to use of a single arterial phase image acquisition series to warrant the increased radiation dose. MATERIALS AND METHODS: Multi-detector row CT was performed in 77 patients with 140 foci of hepatocellular carcinoma (HCC). A triple-phase protocol that included an early arterial phase, a late arterial phase, and a portal venous phase was performed. Images were analyzed separately by three radiologists to document the presence and number of HCC nodules. Separate reading sessions were performed for images from the early arterial phase, images from the late arterial phase, images from both arterial phases combined, and images from all three phases. Sensitivity and positive predictive values were calculated for each reading session. RESULTS: The average sensitivity and positive predictive values, respectively, for the detection of HCC were 48.5% and 96.4% for early arterial phase images, 87.1% and 94.0% for late arterial phase images, 87.1% and 94.0% for images from both arterial phases, and 88.5% and 93.4% for images from all three phases. Analysis of images from both arterial phases together yielded no improvement in either sensitivity or positive predictive value compared with analysis of late arterial phase images alone. Analysis of the combination of late arterial and portal venous phase images resulted in the highest sensitivity value. CONCLUSION: The acquisition of images during two arterial contrast phases does not provide additional benefit over timed conventional biphasic CT technique.

Aged↗

Detection of colorectal lesions: lower-dose multi-detector row helical CT colonography compared with conventional colonoscopy.

PURPOSE: To compare the performance of lower-dose multi-detector row helical computed tomographic (CT) colonography with that of conventional colonoscopy in the detection of colorectal lesions. MATERIALS AND METHODS: One hundred fifty-eight patients underwent multi-detector row helical CT colonography (beam collimation, 4 x 2.5 mm; table feed, 17.5 mm/sec; voltage, 140 kV; and effective dose, 10 mAs) followed by conventional colonoscopy. Conventional colonoscopy served as the reference standard. Two radiologists interpreted CT colonographic images to assess the presence of polyps or carcinomas. Sensitivity was calculated on both a per-polyp and a per-patient basis. In the latter, specificity and positive and negative predictive values were also calculated. Weighted CT dose index was calculated on the basis of measurements obtained in a standard body phantom. Effective dose was estimated by using commercially available software. RESULTS: CT colonography correctly depicted all 22 carcinomas (sensitivity, 100%) and 52 of 74 polyps (sensitivity, 70.3%). Sensitivity for detection was 100% in all 13 polyps 10 mm or larger in diameter, 83.3% in 20 of 24 polyps 6-9 mm, and 51.3% in 19 of 37 lesions 5 mm or smaller. With regard to the per-patient analysis, CT colonography had a sensitivity of 96.0%, a specificity of 96.6%, a positive predictive value of 94.1%, and a negative predictive value of 97.7%. The total weighted CT dose index for combined prone and supine acquisitions was 2.74 mGy. The simulated effective doses for complete CT colonography were 1.8 mSv in men and 2.4 mSv in women. CONCLUSION: Lower-dose multi-detector row helical CT colonography ensures substantial dose reduction while maintaining excellent sensitivity for detection of colorectal carcinomas and polyps larger than 6 mm in diameter.

Aged↗

MR imaging of the small bowel using polyethylene glycol solution as an oral contrast agent in adults and children with celiac disease: preliminary observations.

OBJECTIVE: The purpose of our report is to describe morphologic abnormalities of the small bowel in a population of patients with known celiac disease using MR imaging with polyethylene glycol solution as an oral contrast agent. CONCLUSION: Polyethylene glycol-enhanced MR imaging is a noninvasive (no ionizing radiation is used), feasible, and reproducible imaging technique in both adult and pediatric populations. Findings on polyethylene glycol-enhanced MR imaging, similar to those of conventional barium studies, may suggest a diagnosis of celiac disease because the technique can not only reveal intestinal involvement but also show extraintestinal findings.

Administration, Oral↗

Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study.

The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer.

Adenocarcinoma↗

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience.

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT colonography also detected 10 of 12 polyps (overall sensitivity 83.3%). Based on polyp diameter, the sensitivity for the detection of polyps 10 mm or larger was 100% (3 of 3); between 6 and 9 mm, 100% (3 of 3); and 5 mm or smaller, 66.6% (4 of 6). Total radiation exposure for prone and supine acquisitions combined was 1.7 mSv (for men) and 2.3 mSv (for women). Although preliminary, our experience suggests that ultra-low-dose scanning for multislice CT colonography is feasible. This technique provides a sensitivity comparable to that of previous experiences with CT colonography but with a 40-70% reduction of the radiation dose delivered to patients.

Butylscopolammonium Bromide↗