André Garon

Publications and source records attributed to André Garon.

3 recordsLinked to original sources

Structure of large arteries: orientation of elastin in rabbit aortic internal elastic lamina and in the elastic lamellae of aortic media.

This study was designed to further our understanding of the elastic ultrastructure of vessels. Scanning electron microscopy and transmission electron microscopy were used to study the histomorphologic properties of the elastic fibers of rabbit aorta after purification of the elastin by means of hot alkaline treatments. The elastic fibers of whole rabbit aorta samples were also studied using confocal microscopy. Morphological assessment revealed that the elastin fibers contained in the elastic lamellae of media are perpendicular to the blood flow, and that the elastic fibers of the internal elastic lamina are parallel to the luminal flow. In conclusion, the structure of the elastin making up the elastic lamellae of the media is oriented in such a way as to sustain the circumferential mechanical stress of pulsation. By contrast, the structure of the elastin fibers that make up the internal elastic lamina provides little mechanical support for the circumferential tension, but can support longitudinal loading and act as a fenestrated membrane.

Animals↗

Asymptotically consistent numerical approximation of hemolysis.

In a previous communication, we have proposed a numerical framework for the prediction of in vitro hemolysis indices in the preselection and optimization of medical devices. This numerical methodology is based on a novel interpretation of Giersiepen-Wurzinger blood damage correlation as a volume integration of a damage function over the computational domain. We now propose an improvement of this approach based on a hyperbolic equation of blood damage that is asymptotically consistent. Consequently, while the proposed correction has yet to be proven experimentally, it has the potential to numerically predict more realistic red blood cell destruction in the case of in vitro experiments. We also investigate the appropriate computation of the shear stress scalar of the damage fraction model. Finally, we assess the validity of this consistent approach with an analytical example and with some 3D examples.

Computer Simulation↗

Fast three-dimensional numerical hemolysis approximation.

The in vivo implantation of a mechanical device contributes to hemodynamic disturbances, which are responsible for damage to the membranes of red blood cells that in turn can lead to their rupture (hemolysis). It is important to ascertain at the design stage of such mechanical devices that they are innocuous to blood. Because there is no in vivo hemolysis index, we concentrated our efforts on the in vitro hemolysis index of the American Society for Testing and Material (ASTM) standard. We present in this work a framework for minimizing medical device-induced hemolysis by the development of a numerical method for predicting hemolysis similar to that used in in vitro experiments. The method is based on a novel interpretation of the Giersiepen-Wurzinger blood damage correlation that replaces the computation of blood damage along the streamline by a volume integration of a damage function over the computational domain. We assess the behavior and accuracy of this methodology with 3D examples.

Blood Flow Velocity↗