Search PubMed⌕ Search

Biomedical subjects

Anders Ivarsen

Publications and source records attributed to Anders Ivarsen.

5 recordsLinked to original sources

Corneal power, thickness, and stiffness: results of a prospective randomized controlled trial of PRK and LASIK for myopia.

PURPOSE: To compare the short-, medium-, and long-term changes in corneal optical power and corneal aberrations, central corneal thickness, and corneal "stiffness" assessed by pneumotonometry readings in patients having laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) for myopia. SETTING: Department of Ophthalmology, Arhus University Hospital, Arhus, Denmark. METHODS: One eye of each of 45 patients with myopia ranging from -6.00 to -8.00 diopters (D) (spherical equivalent spectacle refraction [SER]) was randomized to LASIK (n=25; mean SER -7.12 D +/- 0.57 [SD]) or PRK (n=20; mean SER -6.91 +/- 0.57 D). Data were collected prospectively before and 1, 3, 6, 12, and 36 months after surgery. Measurements included corneal topography (TMS-1, Tomey), corneal thickness (ultrasound pachymetry), and apparent intraocular pressure (IOP) (pneumotonometry). Retreatments were not performed during the first year, and retreated eyes were excluded from the 3-year follow-up. Changes in corneal power and aberrations, thickness, and apparent IOP were calculated in a pair-wise manner for 3 time periods: short term (preoperative to 1 month after surgery), medium term (1 to 12 months after surgery), and long term (1 to 3 years after surgery). RESULTS: In the short term, corneal power decreased equally in LASIK and PRK eyes. Spherical aberrations and coma-like aberrations increased equally, while corneal thickness decreased significantly less in LASIK eyes than in PRK eyes. The apparent IOP decreased more in LASIK eyes than in PRK eyes. In the medium term, corneal power increased significantly in both groups. Spherical aberrations decreased significantly in PRK eyes but not in LASIK eyes. From 1 to 12 months, corneal thickness increased more in PRK eyes than in LASIK eyes. During this period, the apparent IOP increased significantly in LASIK eyes. In the long term, corneal power and corneal aberrations did not change significantly in either group. Corneal thickness increased slightly but significantly in both groups. The apparent IOP increased significantly more in PRK eyes. CONCLUSIONS: Differences between LASIK and PRK related to time-dependent events affecting corneal shape and structural integrity were present. Peripheral changes in flap hydration in LASIK eyes and epithelial and/or stromal thickening in PRK eyes appeared to be the most important factors in optical power changes in the first year after treatment. The changes in apparent IOP suggest that some interlamellar healing occurred during the first year after LASIK. After LASIK and PRK, corneal bending stiffness seemed permanently decreased, although some restiffening may occur in PRK eyes in the long term.

Adult↗

LASIK induces minimal regrowth and no haze development in rabbit corneas.

PURPOSE: To quantify central corneal regrowth and haze development after LASIK in rabbits. METHODS: New Zealand White rabbits received an 89 microm (-8 diopters) myopic LASIK and were evaluated during 4 months using slit-lamp and in vivo confocal microscopy to monitor changes in central corneal morphology, epithelial and stromal thickness, flap and bed thickness, and corneal light backscattering (haze). At various time-points, corneas were processed for histology. RESULTS: Using in vivo confocal microscopy, LASIK induced no detectable morphological changes besides a slightly elevated light backscattering at the interface. Correspondingly, all corneas remained clear with no haze development by slit-lamp biomicroscopy. Corneal thickness was stable by 8 weeks after an increase of 17 +/- 4 microm that consisted of a 13 +/- 3 microm stromal regrowth and a 4 +/- 2 microm epithelial hyperplasia. At the LASIK interface, less than 4 microm new extracellular matrix was deposited. Accordingly, all LASIK flaps were easily pulled off by 6 months. CONCLUSIONS: LASIK induces a minimal wound healing response in rabbit corneas with no haze development and a regrowth (regression) of only 17 microm of an 89-microm photoablation. Three main factors contributed to the observed regrowth: epithelial hyperplasia (approximately 4 microm), matrix deposition at the LASIK interface (approximately 4 microm), and stromal growth outside the interface within the flap and wound bed (approximately 9 microm).

Actins↗

Plastic particles at the LASIK interface.

PURPOSE: To investigate the origin, composition, and persistence of the interface particles that frequently are observed after LASIK. DESIGN: Small case series and experimental animal study. METHODS: Four patients received LASIK using a Schwind Supratome (Schwind, Kleinostheim, Germany) and a MEL 70 G-Scan excimer laser (Asclepion, Jena, Germany) and were examined over the course of 1 year using slit-lamp and in vivo confocal microscopy. Four rabbits received a monocular microkeratome incision and were examined immediately after surgery without lifting the flap. After monthly evaluation for 4 months using in vivo confocal microscopy, 2 corneas were processed for histologic analysis and were sectioned serially. To measure the iron content, atomic absorption spectrometry was performed on 2 operated and 2 unoperated rabbit corneas. The chemical composition of the metal and plastic parts of the microkeratome blade was identified using energy dispersive x-ray fluorescence (metal part), and Raman and infrared spectroscopy (plastic part). Before and after oscillation in air, the microkeratome blade and motor-head were examined using light and fluorescence microscopy. In serial sections, interface particles were identified by fluorescence microscopy and their chemical composition was determined using Coherent Antistokes Raman Scattering microscopy. RESULTS: In LASIK patients, thousands of brightly reflecting particles (up to 30 micro m) were observed throughout the interface. The highest particle density was detected where the microkeratome blade had first entered the cornea. Both in the center and at the flap edge, the morphologic features, distribution, and density of these particles remained unaltered throughout the 1-year observation period. In rabbit corneas, interface particles were observed immediately after the microkeratome incision, even though the flap had not been lifted. These particles were similar to those observed in humans and persisted unaltered throughout the study. The operated and unoperated rabbit corneas had comparable iron content, demonstrating that the particles were not fragments of the uncoated steel blade. Only a few particles were observed on the unused microkeratome motor head and blade, whereas numerous fluorescent particles were detected after oscillation in air, the amount of particles increasing with oscillation time. Interestingly, the only fluorescent part of the microkeratome was the plastic segment of the blade. This plastic (polyetherimide) emitted fluorescence identical to that of the observed particles, whereas all metal parts of the microkeratome blade and motor head were nonfluorescent. In serial sections, interface particles showed fluorescent properties equivalent to polyetherimide and exhibited molecular resonance at 1780 and 3100 cm(-1), in accordance with the Raman spectrum of polyetherimide. CONCLUSIONS: Numerous plastic particles are generated during microkeratome oscillation and are deposited at the interface during LASIK. The particles persist unaltered for at least 1 year.

Animals↗

Role of keratocyte loss on corneal wound repair after LASIK.

PURPOSE: To investigate whether an initial keratocyte loss intensifies central corneal wound repair after LASIK in rabbits. METHODS: New Zealand White rabbits received either conventional LASIK (-8 D, 6-mm diameter) or LASIK combined with a 7-mm diameter, epithelial denudation (LASIK-scrape). Animals were examined during 4 months by slit lamp and in vivo confocal microscopy to monitor changes in central corneal morphology, light backscattering (haze), and sublayer thickness. At various time points, corneas were processed for histology and stained for nuclei; F-actin; ED-A fibronectin; alpha-smooth muscle actin; TGF-beta1, -beta2, and -beta receptor II; and connective tissue growth factor (CTGF). RESULTS: In vivo confocal microscopy identified no major acellular zones or changes in cell morphology or reflectivity after conventional LASIK. By contrast, a complete loss of keratocytes was observed in the anterior 77 +/- 25 microm stroma 1 week after LASIK-scrape. Highly reflective, migratory fibroblasts gradually repopulated the acellular zone, and by week 8, quiescent-appearing keratocytes were observed throughout the stroma. Correspondingly, stromal light backscattering peaked at 2 weeks after LASIK-scrape (2200 +/- 620 U) followed by a decline to approximately 60 U from week 8; comparable to the slightly increased reflectivity (approximately 50 U) observed after conventional LASIK (ns). Stromal thickness appeared stable 8 weeks after both LASIK and LASIK-scrape, after a regrowth of 13 +/- 3 and 20 +/- 11 microm, respectively (ns). In addition, both procedures induced a minor and comparable epithelial hyperplasia of 4 +/- 2 and 7 +/- 5 microm, respectively (ns). No myofibroblast transformation or TGF-beta growth factor expression was observed below the flap after either treatment. CONCLUSIONS: LASIK-scrape induces an anterior keratocyte loss, leading to development of temporary haze during cell repopulation. However, 8 weeks after both LASIK and LASIK-scrape, only a slightly increased reflectivity is noted at the interface. Corneal thickness is stable by week 8, and stromal regrowth and epithelial hyperplasia are comparable after both treatments. Thus, an initial loss of stromal keratocytes does not appear to intensify corneal wound repair after LASIK.

Actins↗

Validation of confocal microscopy through focusing for corneal sublayer pachymetry.

PURPOSE: To evaluate the accuracy and precision of confocal microscopy through focusing (CMTF) for corneal sublayer pachymetry. METHODS: A tandem scanning confocal microscope equipped with a nonapplanating contact objective was used to perform CMTF. The accuracy of CMTF measurements was evaluated using nine custom-made calibration contact lenses (PMMA) with varying thickness (300-600 microm) and radius of curvature (7.0-9.0 mm). The influence of immersion fluid stabilization and the consequence of prolonged corneal examination were assessed by performing CMTF in rabbits. Additionally, factors related to the instrumental setup and to sedation of experimental animals were examined. RESULTS: For all calibration contact lenses, the thickness measured by CMTF was within +/-1.0 microm of the certified value. Varying the target thickness or radius of curvature had no consistent impact on the high accuracy of CMTF. When performing CMTF in vivo, z-axis motion was readily identified by sampling and comparing both in- and out-scans. Apart from involuntary eye movements, z-axis motion was due to initial thinning of the immersion fluid with stabilization obtained after approximately 1.5 minutes. Continued confocal examination led to slight but significant swelling of both the stroma (0.5 microm/min) and epithelium (0.1 microm/min). CONCLUSIONS: CMTF is an accurate and precise technique for corneal sublayer pachymetry with concurrent display of cellular morphology. The precision of CMTF can be improved by allowing time for methylcellulose stabilization and by performing repeated two-way (in and out) scans to account for z-axis motion.

Air↗