Search PubMed⌕ Search

Biomedical subjects

Anders Franco-Cereceda

Publications and source records attributed to Anders Franco-Cereceda.

17 recordsLinked to original sources

A functional genomic framework to elucidate novel causal metabolic dysfunction-associated fatty liver disease genes.

BACKGROUND AND AIMS: Metabolic dysfunction-associated fatty liver disease (MASLD) is the most prevalent chronic liver pathology in western countries, with serious public health consequences. Efforts to identify causal genes for MASLD have been hampered by the relative paucity of human data from gold standard magnetic resonance quantification of hepatic fat. To overcome insufficient sample size, genome-wide association studies using MASLD surrogate phenotypes have been used, but only a small number of loci have been identified to date. In this study, we combined genome-wide association studies of MASLD composite surrogate phenotypes with genetic colocalization studies followed by functional in vitro screens to identify bona fide causal genes for MASLD. APPROACH AND RESULTS: We used the UK Biobank to explore the associations of our novel MASLD score, and genetic colocalization to prioritize putative causal genes for in vitro validation. We created a functional genomic framework to study MASLD genes in vitro using CRISPRi. Our data identify VKORC1 , TNKS , LYPLAL1 , and GPAM as regulators of lipid accumulation in hepatocytes and suggest the involvement of VKORC1 in the lipid storage related to the development of MASLD. CONCLUSIONS: Complementary genetic and genomic approaches are useful for the identification of MASLD genes. Our data supports VKORC1 as a bona fide MASLD gene. We have established a functional genomic framework to study at scale putative novel MASLD genes from human genetic association studies.

Humans↗

Reversed remodelling in dilated cardiomyopathy by passive containment surgery is associated with decreased circulating levels of endothelin-1.

OBJECTIVE: To evaluate the influence on circulating levels of endothelin-1 and big endothelin-1 in relation to echocardiographic findings and functional assessment, by passive containment surgery in heart failure patients with dilated cardiomyopathy. METHODS: Thirteen patients with dilated cardiomyopathy subjected to cardiac surgery received the Acorn Cardiac Support Device. Patients with ischemic dilated cardiomyopathy (n=6) underwent coronary artery bypass surgery receiving one to three bypass grafts. In the idiopathic dilated cardiomyopathy group (n=7), mitral valve plasty was performed in five patients while two patients received the cardiac support device only. Circulating plasma levels of endothelin-1 and big endothelin-1 were measured in all patients before surgery and 12 months after surgery. Concomitantly New York Heart Association functional class and 6-min walk were evaluated and cardiac dimensions measured with echocardiography. RESULTS: Following surgery there was a significant decrease in circulating plasma levels of endothelin-1 (5.9+/-0.6 pM preoperatively vs 4.3+/-0.3 pM postoperatively, P<0.05). New York Heart Association functional class improved (2.8+/-0.2 preoperatively vs 1.8+/-0.2 postoperatively, P<0.05). The 6-min walk increased (384+/-24 m preoperatively vs 465+/-33 m postoperatively, P<0.05). There was also a decrease in left ventricular end diastolic diameter (69+/-2mm preoperatively vs 62+/-2mm postoperatively, P<0.05) and left ventricular end systolic diameter (60+/-2mm preoperatively vs 54+/-3mm postoperatively, P<0.05). Linear correlation revealed a relationship between decreased left ventricular end diastolic diameter and decreased endothelin-1 levels (R=0.56; P<0.05). CONCLUSIONS: Following passive containment surgery using the Acorn Cardiac Support Device there is a decrease in circulating levels of endothelin-1 concomitant with a decrease in cardiac dimensions and function improvement.

Adult↗

Invited commentary.

Explore the source record for details and available documents.

Coronary Artery Bypass↗

Echocardiographic findings using tissue velocity imaging following passive containment surgery with the Acorn CorCap cardiac support device.

OBJECTIVE: To echocardiographically evaluate the effects of passive containment surgery using the CorCap Cardiac Support Device in heart failure patients with dilated cardiomyopathy. METHODS: Twelve patients with dilated cardiomyopathy subjected to cardiac surgery received the Cardiac Support Device. Patients with ischemic cardiomyopathy (n=5) underwent coronary artery bypass surgery receiving 1-3 bypass grafts. In the idiopathic cardiomyopathy group (n=7), mitral valve annuloplasty was performed in five patients while two patients received the Cardiac Support Device only. RESULTS: Following surgery there was a gradual, sustained improvement in cardiac dimensions (decreased left ventricular end-diastolic diameter and left ventricular end-systolic diameter) combined with an increase in functional status (6-min walk and NYHA class). Concomitantly there was a marked decrease in right ventricular function (decrease in tricuspid annular systolic and diastolic velocities) while the left ventricular function (mitral annular systolic and diastolic velocities) and output (ejection fraction, stroke volume) remained unchanged. CONCLUSIONS: Addition of the Cardiac Support Device to conventional cardiac surgery improves patient status and decreases left ventricular size in heart failure patients with dilated cardiomyopathy. The positive effect on left ventricular dimensions is not accompanied by any improvement in cardiac output but rather right ventricular dysfunction, although the functional significance of this is unclear.

Adult↗

Attenuation of postoperative noradrenaline need by nitric oxide inhibition using L-NMMA.

In the present report we describe that NG-monomethyl-L-arginine acetate, a non-specific nitric oxide synthesis inhibitor, administered at 1 mg kg(-1) h(-1) to a patient with critical hypotension following mitral valve surgery combined with passive containment surgery, increased the urinary output and arterial blood pressure while the need for noradrenaline was rapidly attenuated. Again increasing the noradrenaline infusion in the presence of NG-monomethyl-L-arginine acetate caused a dramatic increase of the blood pressure.

Blood Pressure↗

One-year clinical experience with the Acorn CorCap cardiac support device: results of a limited market release safety study in Italy and Sweden.

BACKGROUND: The Acorn CorCap cardiac support device (CSD) is a mesh-like device intended to provide end-diastolic support and reduce ventricular wall stress. Animal studies with the CorCap CSD have demonstrated beneficial reverse remodeling, and preliminary safety studies in patients with heart failure have shown that the device is safe and associated with improved left ventricular (LV) structure and function. The objective of the current study was to further evaluate the safety and efficacy of the CorCap CSD in patients with advanced heart failure. METHODS: Twenty-four patients with dilated cardiomyopathy, severe LV dysfunction, and advanced heart failure (NYHA class II-IV) were enrolled at four centers in Italy and Sweden. All patients underwent CorCap CSD implantation either alone (n = 3) or in combination with mitral valve repair/replacement (n = 13), coronary artery bypass surgery (n = 6), combined mitral valve repair/coronary artery bypass surgery (n = 1) or aneurysmectomy (n = 1). RESULTS: The LV end-diastolic diameter decreased from 69.3 +/- 7.2 to 60.1 +/- 9.0 mm at 3 months, 60.9 +/- 9.6 mm at 6 months, and 58.9 +/- 8.0 mm at 12 months (all p < 0.05). A trend toward an improved LV ejection fraction (28.8 +/- 10.5% at baseline and 32.4 +/- 12.7, 33.1 +/- 10.8, and 33.8 +/- 13.9% at 3, 6 and 12 months respectively) was also noted. The NYHA functional class, 6-min walking distance, and quality of life as measured using Uniscale were all improved. There were no differences in response among the patients submitted to the different types of concomitant surgery. CONCLUSIONS: In agreement with earlier safety studies, even the present investigation demonstrated improvements in cardiac structure and function as well as in patient functional status after Cor Cap CSD implantation. Randomized controlled trials are in progress.

Adult↗

[ECMO treatment saved life of a young woman with acute pulmonary embolism].

A 42-year old obese female using contraceptive medication was admitted to the emergency room because of sudden onset of dyspnoea and hypoxia. Computed tomography showed massive pulmonary emboli. Despite initial treatment with thrombolysis her condition deteriorated further and she was referred for acute surgery to our clinic. Before putting the patient to sleep extracorporeal circulation was instituted with access from the groin. After anaesthesia a median sternotomy was performed. With the heart beating, the main pulmonary artery was incised and a 9 cm long thrombus was removed. Immediate weaning from the heart-lung machine was not possible, mainly because of bleeding to the airways. The right atrium and the aorta was therefore cannulated and an extracorporeal circulation membrane oxygenator (ECMO) was used for three days. The patient required several re-entries for bleeding and a tracheotomy during the postoperative course. She was fully recovered three months after the operation.

Acute Disease↗

Early results with cardiac support device implant in patients with ischemic and non-ischemic cardiomyopathy.

OBJECTIVE: To evaluate the possible beneficial echocardiographic, functional and quality of life improving effects of passive containment surgery using the CorCap Cardiac Support Device in heart failure patients with dilated cardiomyopathy. DESIGN: Eight patients with dilated cardiomyopathy subjected to cardiac surgery received the Cardiac Support Device. Patients with ischemic cardiomyopathy (n = 4) underwent coronary artery bypass surgery receiving one to three bypass grafts. In the idiopathic cardiomyopathy group (n = 4) mitral valve plasty was performed in two patients while two patients received the Cardiac Support Device only. RESULTS: All patients survived the surgery and were discharged to home. There was a gradual, sustained improvement in cardiac dimensions (left ventricular end-diastolic diameter, left ventricular end-systolic diameter) and functional improvement (ejection fraction, 6-min walk, NYHA functional class) as well as quality of life. These beneficial effects developed more rapidly and more extensively in the idiopathic cardiomyopathy group. CONCLUSION: Addition of the Cardiac Support Device to conventional cardiac surgery, or applied alone, is safe and simple. The device seems to reverse ventricular dilatation and improve functional capacity and well-being of heart failure patients with dilated cardiomyopathy. Further studies will delineate what patient population will best benefit from passive containment surgery using the CorCap Cardiac Support Device.

Adaptation, Physiological↗

Endothelin and effects of endothelin-receptor activation in the mammary and radial artery.

OBJECTIVE: To determine the tissue content and endothelin-receptor characteristics of endothelin-1 in the radial artery in relation to the internal mammary artery. DESIGN: Endothelin-1 content was quantified in the radial artery and the internal mammary artery. Both arteries were exposed to endothelin-1 and agonists of the endothelin A and B receptors. RESULTS: The highest level of endothelin-1 was found in the radial artery. Endothelin-1 contracted both arteries. The contraction was sensitive to endothelinA-receptor agonism and enhanced in both arteries by inhibition of prostacyclin and nitric oxide formation. In the internal mammary artery the endothelinB-receptor agonist caused an endothelinA-receptor sensitive contraction augmented by inhibition of nitric oxide and prostacyclin. However, in the radial artery this contraction was only observed in the presence of inhibition of nitric oxide and prostaglandin. CONCLUSION: The highest endothelin-1 content was found in the radial artery. The functional effects of endothelin-1 in the radial artery were similar to that in the internal mammary artery, mediated by predominantly endothelinA-receptor activation causing vasoconstriction. Selective endothelinA-receptor blockade may prove beneficial in preventing graft spasm in the radial as well as the internal mammary artery.

Biomarkers↗

Splanchnic metabolism during gut ischemia and short-term endotoxin and hemorrhagic shock as evaluated by intravasal microdialysis.

The splanchnic area is of considerable interest in different types of shock. To characterize the metabolic changes in the splanchnic region in response to different types of shock we used a model where shock-induced metabolic changes in the splanchnic region were studied by the use of intravasal microdialysis. 23 anesthetized domestic pigs were randomized into four groups: Group I, serving as controls (n = 5); Group II, mesenteric ischemia for 180 followed by 120 min of reperfusion (n = 5); Group III, endotoxin shock for 5 h (n = 5); and Group IV, hemorrhagic shock for 180 min followed by re-transfusion of shed blood (n = 8). Microdialysis catheters were placed in the left femoral artery, portal vein and a small ileal mesenteric vein. Samples of the perfusate were continuously collected in micro-vials and analyzed for glucose, lactate, pyruvate and glycerol. In gut ischemia and endotoxin shock the outflow-pattern of lactate, lactate/pyruvate ratio and glucose in the mesenteric vein differed significantly from controls and hemorrhage whereas an increase in glycerol was only noted in the ischemic group. The most prominent differences were detected in lactate/pyruvate ratio, a marker of tissue ischemia with the most pronounced changes during mesenteric ischemia/reperfusion. During endotoxin shock increases in microdialysate metabolites were only noted in the splanchnic region suggesting a specific vulnerability in the region. Studying the lactate/pyruvate ratio may provide additional information when interpreting increased blood lactate levels. In addition glycerol may prove to be a useful marker of splanchnic ischemia. Intravasal microdialysis represents a potentially useful method for monitoring regional metabolic events.

Abdomen↗

Cardiac outflow of amino acids and purines during myocardial ischemia and reperfusion.

A novel application of microdialysis was studied, in which myocardial outflow of amino acids and purines was monitored by intravasal microdialysis in the myocardial venous outflow during ischemia and reperfusion. Microdialysis catheters were introduced into the great cardiac vein, pulmonary artery, and external jugular vein in 20 anesthetized pigs. The left anterior descending artery was occluded in four groups of pigs for 0, 10, 15, and 60 min. Ischemia was followed by 120 min of reperfusion. Microdialysis samples were analyzed for taurine, aspartate, glutamate, hypoxanthine, inosine, and guanosine. Myocardial infarction developed when ischemia exceeded 10 min. Taurine, aspartate, inosine, and guanosine increased early in the great cardiac vein during ischemia. We found the outflow patterns of amino acids and purines to be graded in response to different lengths of ischemia. In this study we have demonstrated a graded outflow of amino acids and purines in response to ischemia and a positive correlation between infarct size and myocardial outflow of amino acids and purines. This could be of value in a clinical setting to quantify the extent of myocardial damage.

Amino Acids↗

Is there a role for endothelin-blockade early after coronary artery bypass grafting?

BACKGROUND: Diverse results exist regarding myocardial release of endothelin after coronary artery bypass grafting. Because endothelin may be involved in regulation of coronary blood flow, postoperative endothelin-blockade could influence the surgical outcome. In this study, we have evaluated the cardiac outflow of endothelin and effects on coronary flow by endothelin-blockade immediately after completion of the coronary bypass grafting. METHODS: Thirty patients were subjected to infusions of endothelinA blocker (BQ-123, 260 nmoL/min for up to 30 minutes) or endothelinA blocker and endothelinB blocker (BQ-123 and BQ-788, 260 and 250 nmol/min, respectively, for up to 30 minutes) into a veingraft anastomosed to a coronary vessel, and the coronary blood flow was measured. Plasma levels of endothelin from the coronary sinus and the periphery were determined. RESULTS: There were no significant changes in flow caused by endothelinA blockade alone or in combination with endothelinB blockade. There were no immediately increased levels of endothelin after surgery or after infusions of the endothelin blockers. CONCLUSIONS: Endothelin blockade does not influence the immediate perioperative myocardial blood flow after coronary bypass grafting. There is no significantly increased myocardial outflow of endothelin, and endothelin does not have any influence on the basal tone of the coronary vessels in the early phase after coronary bypass grafting.

Aged↗

Plasma levels and vascular effects of endothelin and big endothelin in patients with stable and unstable angina pectoris undergoing coronary bypass grafting.

OBJECTIVES: The aim of this study was to determine the plasma and pericardial levels of endothelin-1 (ET-1) and its precursor big endothelin-1 (Big ET-1) in patients with unstable and stable angina prior to and following coronary bypass surgery. To further investigate the content of ET-1, tissue levels were studied in the internal mammary artery (IMA) in patients with stable and unstable angina pectoris. Finally, the difference in reactivity of the IMA to ET-1 and Big ET-1 in stable and unstable patients was evaluated. METHODS: Plasma and pericardial levels of ET-1 and Big ET-1 were determined with radioimmunoassay in 81 patients (33 unstable) immediately before coronary bypass surgery, and at 6, 14, 40 and 64 h following the procedure. Specimens of the distal IMA from 12 patients (six unstable) were collected at the beginning of surgery for determination of tissue levels of ET-1. Additionally, distal internal mammary arteries were obtained from another 24 patients (12 unstable). These vessels were mounted in organ baths for functional studies on vascular reactivity to ET-1 and Big ET-1. RESULTS: The peripheral plasma levels of ET-1 in unstable patients were significantly lower in patients with unstable angina compared with patients with stable angina pectoris at all points of measurement. The levels of Big ET-1 were significantly higher pre-operatively in the unstable group, but decreased to similar levels to those of stable patients following coronary bypass grafting. There was no difference in ET-1 tissue content in the IMA between the patients. ET-1 and Big ET-1 caused an endothelin(A) (ET(A))-receptor blocker sensitive, concentration-dependent contraction of the IMA obtained from stable as well as unstable patients. CONCLUSIONS: It is concluded that unstable angina pectoris is associated with an increased ET-1 turnover. This increased turnover may participate in the local regulation of coronary vascular tone with subsequent influence of the condition of the patients. The present investigation also implies that ET(A)-blockade may be useful as an additional pharmacological principal in the treatment of unstable angina pectoris prior to revascularization, as well as to prevent post-operative arterial graft spasm.

Adult↗

Monitoring of porcine myocardial ischemia and reperfusion by intravasal microdialysis.

OBJECTIVE: A novel application of microdialysis is studied where myocardial metabolism is semi-continuously monitored in the myocardial venous outflow during ischemia and reperfusion. DESIGN: Microdialysis catheters were introduced into the great cardiac vein, the pulmonary artery, and the right external jugular vein in 20 anesthetized pigs. The left anterior descending artery was occluded in four separate groups of pigs for 0, 10, 15, and 60 min, respectively. Ischemia was followed by 120 min of reperfusion. Microdialysis samples were collected every 10-20 min and analyzed for lactate, pyruvate, glycerol, glutamate, and glucose. RESULTS: Myocardial infarction was observed after 15 min of ischemia. Metabolic changes were observed only in the great cardiac vein. Lactate increased early during ischemia. After 60 min of ischemia an increase of the lactate/pyruvate ratio and glutamate was observed. Glycerol was progressively released during prolonged ischemia. Myocardial infarction resulted in an additional release of glycerol early in reperfusion. CONCLUSION: Intravasal microdialysis is a semi-continuous method to monitor myocardial metabolism and tissue damage during ischemia and reperfusion.

Animals↗

[Passive volume-reducing surgery in heart failure and dilated cardiomyopathy. Results from a pilot study account for careful optimism].

Twelve patients with dilated cardiomyopathy and heart failure subjected to cardiac surgery received the CorCap Cardiac Support Device (CSD), a polyester fabric with bi-directional compliance placed around the dilated, failing heart. Patients with ischemic cardiomyopathy (n = 6) additionally underwent coronary artery bypass surgery receiving 1-3 bypass grafts. In the idiopathic cardiomyopathy group (n = 6) mitral valve plasty was performed in four patients in combination with the CSD, while two patients received the CSD only. Twelve months follow-up revealed a gradual, sustained improvement in cardiac dimensions and functional improvement as well as in quality of life. We conclude that addition of the CSD to conventional cardiac surgery, or applied alone, seems to reverse ventricular dilatation and improve functional capacity and well being of heart failure patients with dilated cardiomyopathy. Further studies will delineate what patient population will best benefit from passive containment surgery using the CSD.

Adult↗