Search PubMed⌕ Search

Biomedical subjects

Alfredo Sanz-Medel

Publications and source records attributed to Alfredo Sanz-Medel.

At least 19 recordsLinked to original sources

Accurate determination of human serum transferrin isoforms: Exploring metal-specific isotope dilution analysis as a quantitative proteomic tool.

Carbohydrate-deficient transferrin (CDT) measurements are considered a reliable marker for chronic alcohol consumption, and its use is becoming extensive in forensic medicine. However, CDT is not a single molecular entity but refers to a group of sialic acid-deficient transferrin isoforms from mono- to trisialotransferrin. Thus, the development of methods to analyze accurately and precisely individual transferrin isoforms in biological fluids such as serum is of increasing importance. The present work illustrates the use of ICPMS isotope dilution analysis for the quantification of transferrin isoforms once saturated with iron and separated by anion exchange chromatography (Mono Q 5/50) using a mobile phase consisting of a gradient of ammonium acetate (0-250 mM) in 25 mM Tris-acetic acid (pH 6.5). Species-specific and species-unspecific spikes have been explored. In the first part of the study, the use of postcolumn addition of a solution of 200 ng mL(-1) isotopically enriched iron (57Fe, 95%) in 25 mM sodium citrate/citric acid (pH 4) permitted the quantification of individual sialoforms of transferrin (from S2 to S5) in human serum samples of healthy individuals as well as alcoholic patients. Second, the species-specific spike method was performed by synthesizing an isotopically enriched standard of saturated transferrin (saturated with 57Fe). The characterization of the spike was performed by postcolumn reverse isotope dilution analysis (this is, by postcolumn addition of a solution of 200 ng mL(-1) natural iron in sodium citrate/citric acid of pH 4). Also, the stability of the transferrin spike was tested during one week with negligible species transformation. Finally, the enriched transferrin was used to quantify the individual isoforms in the same serum samples obtaining results comparative to those of postcolumn isotope dilution and to those previously published in the literature, demonstrating the suitability of both strategies for quantitative transferrin isoform determination in real samples.

Acetates↗

Selenium species in aqueous extracts of alfalfa sprouts by two-dimensional liquid chromatography coupled to inductively coupled plasma mass spectrometry and electrospray mass spectrometry detection.

The complementary use of two different liquid chromatographic mechanisms coupled to inductively coupled plasma mass spectrometry (ICP-MS) for selenium (Se) specific detection has permitted the screening of the most abundant Se-containing fractions in selenized alfalfa sprouts (Medicago sativa). Aqueous extracts of the sprouts were fractionated first by size exclusion chromatography (SEC) using a Superdex Peptide column and a mobile phase containing an ammonium acetate buffer (pH 7). Further purification of the individual SEC Se-containing fractions was carried out using two different chromatographic systems: a Shodex Ashaipack column, with a mixed mechanism of size exclusion and ion exchange, and a conventional reversed phase C8 using ion-pairing reagents. In both cases, the columns were coupled to an inductively coupled plasma mass spectrometer equipped with an octapole reaction system for Se specific detection. This system allowed the on-line monitoring of the most abundant Se isotopes (78Se, 80Se) by reducing the possible polytomic interferences affecting these ions by adding hydrogen (2 mL min(-1)) to the octapole reaction cell. The results obtained by both separation mechanisms were highly comparable, revealing the presence of Se-methionine and Se-methyl selenocysteine. Both compounds were then confirmed by analyzing the corresponding fractions by electrospray quadrupole-time-of-flight (ESI-Q-TOF) mass spectrometry. Finally, an additional Se-containing species showing Se isotope distribution was detected at a molecular ion m/z 239 in the ESI-Q-TOF. The collision-induced dissociation of the m/z 239 and 237 ions (corresponding to 80Se and 78Se isotopes, respectively) revealed the possible presence as well of a derivative of the Se-2-propenyl selenocysteine.

Chromatography, High Pressure Liquid↗

Certification of a new selenized yeast reference material (SELM-1) for methionine, selenomethinone and total selenium content and its use in an intercomparison exercise for quantifying these analytes.

A new selenized yeast reference material (SELM-1) produced by the Institute for National Measurement Standards, National Research Council of Canada (INMS, NRC) certified for total selenium (2,059+/-64 mg kg(-1)), methionine (Met, 5,758+/-277 mg kg(-1)) and selenomethionine (SeMet, 3,431+/-157 mg kg(-1)) content is described. The +/-value represents an expanded uncertainty with a coverage factor of 2. SeMet and Met amount contents were established following a methanesulfonic acid digestion of the yeast using GC-MS and LC-MS quantitation. Isotope dilution (ID) calibration was used for both compounds, using 13C-labelled SeMet and Met. Total Se was determined after complete microwave acid digestion based on ID ICP-MS using a 82Se spike or ICP-OES spectrometry using external calibration. An international intercomparison exercise was piloted by NRC to assess the state-of-the-art of measurement of selenomethione in SELM-1. Determination of total Se and methionine was also attempted. Seven laboratories submitted results (2 National Metrology Institutes (NMIs) and 5 university/government laboratories). For SeMet, ten independent mean values were generated. Various acid digestion and enzymatic procedures followed by LC ICP-MS, LC AFS or GC-MS quantitation were used. Four values were based on species-specific ID calibration, one on non-species-specific ID with the remainder using standard addition (SA) or external calibration (EC). For total selenium, laboratories employed various acid digestion procedures followed by ICP-MS, AFS or GC-MS quantitation. Four laboratories employed ID calibration, the remaining used SA or EC. A total of seven independent results were submitted. Results for methionine were reported by only three laboratories, all of which used various acid digestion protocols combined with determination by GC-MS and LC UV. The majority of participants submitted values within the certified range for SeMet and total Se, whereas the intercomparison was judged unsuccessful for Met because only two external laboratories provided values, both of which were outside the certified range.

Chromatography, Liquid↗

Direct comparison of capillary electrophoresis and capillary liquid chromatography hyphenated to collision-cell inductively coupled plasma mass spectrometry for the investigation of Cd-, Cu- and Zn-containing metalloproteins.

Capillary liquid chromatography (cLC) and capillary electrophoresis (CE) have been critically compared for the separation of metalloproteins when using collision-cell inductively coupled plasma mass spectrometry (ICP-CC-MS) as detection system. For cLC separation, the selected column was a C8 (0.3 mm I.D.) and the separation conditions involved a gradient up to 80% methanol in 10mM ammonium acetate buffer (pH 7.4). The low flow rate used (3 microL min(-1)) permitted the utilization of a high methanol content maintaining the sensitivity along the whole chromatographic run. For this purpose, a new low-flow interface has been developed based on a total consumption nebulizer. Similarly, CE has been studied as separation technique using a 75 microm I.D. fused silica capillary and a running buffer of 20 mM Tris-HNO3 (pH 7.4) and working at 30 kV. Metallothionein (mixture of MT-I and -II) and superoxide dismutase (SOD) have been used as protein models in order to evaluate the separation/detection capabilities using the same injection volumes in both systems (20 nL). For both hybrid systems, separation parameters such as retention factor, numbers of theoretical plates, tailing factor and resolution have been critically compared. Also, the analytical performance characteristics of both hybrid systems have been evaluated and tested by analyzing the Cu-, Zn-species present in red blood cell extracts in order to explore more adequate separation methodology for the analysis of metalloproteins in complex matrices.

Animals↗

Selenium bioaccessibility assessment in selenized yeast after "in vitro" gastrointestinal digestion using two-dimensional chromatography and mass spectrometry.

In order to investigate the potentially bioavailable selenium-containing compounds in the selenized yeast candidate reference material SEAS 6, a two-dimensional (size exclusion-reversed phase) chromatography approach has been worked out. Electrospray tandem mass spectrometry (ESI Q-TOF MS) was then used for off-line identification of low molecular weigh selenocompounds generated during the gastrointestinal digestion. Selenomethionine (SeMet) was the major compound identified in the gastrointestinal extract while SeMet selenoxide was its main degradation product formed after medium and long-term sample storage, respectively. Total Se and SeMet were quantified in both the soluble extracts and the residue. Results showed that 89+/-3% of total Se was extracted after gastrointestinal digestion, but only 34+/-1% was surprisingly quantified as free SeMet. The rest of Se was present as many other low, medium and high molecular weight Se-species, which could be detected and further characterized by using the two-dimensional chromatography approach proposed here. Interestingly, most of Se-species seemed to be Se-peptides unspecifically produced by the gastrointestinal juice. These results show for the first time that while the efficiency of human gastrointestinal digestion to dissolve Se-containing proteins present in yeast may be high, its efficiency to convert them into free SeMet is much lower. Se-species present in the insoluble residue (not assimilated by the organism), accounting for 11+/-1% of the total Se in selenized yeast, were also studied. After treatment with SDS (denaturing agent) only 13+/-2% of this "insoluble" Se was solubilized, indicating that it was mainly non-protein bound and likely associated to other insoluble matrix components.

Chromatography, High Pressure Liquid↗

Isotope dilution SPME GC/MS for the determination of methylmercury in tuna fish samples.

The development of a rapid, precise and accurate analytical method for the determination of methylmercury in tuna fish samples is described. The method is based on the use of isotope dilution GC/MS with electron impact ionization, a widespread technique in routine testing laboratories. A certified spike containing (202)Hg-enriched methylmercury was used for the isotope dilution of the samples. After extraction of the methylmercury from the sample, methylmercury was propylated using sodium tetrapropyl borate in SPME vials and the analytes were sampled from the headspace for 15 min. For isotope measurements, the molecular ion (MePrHg(+)) was used in the SIM mode. Five molecular ions were monitored, corresponding to the (198)Hg, (199)Hg, (200)Hg, (201)Hg and (202)Hg isotopes. The detection at masses corresponding to (198)Hg was used to correct for m + 1 contributions of (13)C from the organic groups attached to the mercury atom on the (199)Hg, (200)Hg, (201)Hg and (202)Hg masses with simple mathematical equations, and the concentration of methylmercury was calculated on the basis of the corrected (200)Hg/(202)Hg isotope ratio. The (202)Hg-enriched methylmercury spike was applied, with satisfactory results, to the determination of methylmercury in the certified reference material BCR 464. The method was successfully applied to the determination of methylmercury in tuna fish samples, and the obtained results were included in the CCQM-P39 interlaboratory exercise, organized by the Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) with excellent agreement between our results and the average obtained by the other participants.

Algorithms↗

Study of phytochelatins and other related thiols as complexing biomolecules of As and Cd in wild type and genetically modified Brassica juncea plants.

The accumulation of As and Cd in Brassica juncea plants and the formation of complexes of these elements with bioligands such as glutathione and/or phytochelatins (PCs) is studied. The genetic manipulation of these plants to induce higher As and Cd accumulation has been achieved by overexpressing the genes encoding for gamma-glutamyl cysteine synthetase (gamma-ECS) and glutathione synthetase (GS). These two enzymes are responsible for glutathione (GSH) formation in plants, which is the first step in the production of PCs. The biomass produced in both the wild type and the genetically modified plants, has been evaluated. Additionally, the total Cd and As concentration accumulated in the plant tissues was measured by inductively coupled plasma mass spectrometry (ICP-MS) after extraction. Speciation studies on the extracts were conducted using size exclusion liquid chromatography (SEC) coupled online with ICP-MS to monitor As, Cd and S. For further purification of the As fractions, reversed phase high performance liquid chromatography (RP-HPLC) was used. Structural elucidation of the PCs and other thiols, as well as their complexes with As and Cd, was performed by electrospray-quadrupole-time-of-flight (ESI-Q-TOF). In both the Cd and As exposed plants it was possible to observe the presence of oxidized PC2 ([M + H]+, m/z 538), GS-PC2(-Glu) ([M + H]+, m/z 716) as well as reduced GSH ([M + H]+, m/z 308) and oxidized glutathione (GSSG) ([M + H]+, m/z 613). However, only the GS plants exhibited the presence of As(GS)3 complex ([M + H]+, m/z 994) that was further confirmed by MS/MS. This species is reported for the first time in B. juncea plant tissues.

Arsenic↗

Species-specific isotope dilution analysis and isotope pattern deconvolution for butyltin compounds metabolism investigations.

A methodology for the study of the absorption and metabolism of butyltin compounds in laboratory animals using isotopically enriched species was developed. The method is based on the oral administration of 119Sn-labeled monobutyltin (MBT), 118Sn-labeled dibutyltin (DBT), and 117Sn-labeled tributyltin (TBT) to the animals and the measurement of both the concentration and isotopic composition of these compounds in the different tissues by GC-ICPMS. The degradation of butyltin compounds during their metabolism was computed using least-squares isotope pattern deconvolution, and their concentration was measured by reverse isotope dilution analysis using natural-abundance MBT, DBT, and TBT standards. Male Wistar rats were used as models to evaluate the proposed methodology. Preliminary toxicological results obtained with one rat indicate that TBT is highly absorbed (64.4%), and it is found in all organs with relatively high levels in stomach and intestines. The apparent absorption of DBT was 27.3% and was mainly found in liver, kidney, and intestines. However, a large proportion of the found DBT is formed from the degradation of TBT (approximately 40% of the found DBT in liver is degraded TBT). The apparent absorption of MBT was found to be 12.5%, and the originally administered MBT was mainly recovered in the feces. However, MBT was clearly detected in liver, kidney, stomach, intestines, and urine as degradation products of DBT and TBT. Although a significant variability from rat to rat is expected to be obtained, the analytical variability provided by this methodology is small enough to yield meaningful biological results. The results obtained demonstrate that the developed methodology is able to follow qualitatively, quantitatively, and simultaneously the specific metabolic pathways of different species of a given element.

Animals↗

An attempt to differentiate HPLC-ICP-MS selenium speciation in natural and selenised Agaricus mushrooms using different species extraction procedures.

Total determination and speciation analysis of Se in commercial and selenised Agaricus mushrooms have been performed to investigate the Se species naturally occurring in non-enriched mushrooms as well as those present in specimens grown in a Se-enriched medium. Mushroom aqueous and enzymatic extracts have been analysed by three complementary chromatographic separation mechanisms (size-exclusion, anion-exchange and reversed-phase) coupled to an inductively coupled plasma mass spectrometer with an octopole reaction system. Post-column isotope dilution analysis has been used on-line with the separations for quantification of the Se species eluted. The 78Se-to-77Se isotope ratio was monitored after adequate corrections for both total determinations and Se species quantitative speciation. The results showed marked differences not only in total Se contents but also in Se species found in the two types of Agaricus mushrooms investigated. Selenomethionine was detected in both of them (free in commercial mushrooms and incorporated into proteins in selenised ones) together with a number of unknown selenocompounds.

Agaricus↗

In-depth profile analysis of thin films deposited on non-conducting glasses by radiofrequency glow-discharge-optical emission spectrometry.

The potential of radiofrequency glow-discharge-optical emission spectrometry (rf-GD-OES) for quantification of thin films on non-conducting materials has been investigated. A commercial rf-GD chamber from Jobin Yvon operated at 13.56 MHz with Ar as discharge gas was used. The signal integration time was 0.1 s. The effect on emission yields of thin conducting layers on glasses of different thickness was studied in detail, using the rf-GD in the common operating mode "constant pressure-constant forward power". Calibration curves were obtained for two types of material-conducting reference materials and a set of non-conductors comprising homogeneous glass of known composition and three different thicknesses coated (or not) with thin layers of gold. Qualitative and quantitative in-depth profile analyses of different coated non-conducting samples were investigated. A variety of samples, including different thick glass substrates (from 1.8 to 5.8 mm), different thin films deposited on homogeneous glasses (from 6 nm to 35 nm), and different kinds of coating (conductors such as Fe, Ni, Cr, Al, and Nb and non-conductors such as Si3N4) were studied at 450 Pa pressure and 20 W forward power. The quantitative in-depth profiles proved satisfactory and results for depths and concentrations were similar to nominal values.

Journal Article↗

Molecularly imprinted polymers based on iodinated monomers for selective room-temperature phosphorescence optosensing of fluoranthene in water.

Aiming at enhancing the advantages of traditional molecularly imprinted polymers (MIPs) for chemical sensing, a new MIP design approach introducing an internal heavy atom in their polymeric structure is described. Based on the heavy-atom effect, the novel polymer allows one to perform room-temperature phosphorescence (RTP) transduction of the analyte. The synergic combination of a tailor-made MIP recognition with a selective RTP detection is a novel concept for optosensing devices which is assessed here for simple and highly selective determination of trace amounts of fluoranthene in water. The noncovalent MIP was synthesized using the laboratory-synthesized tetraiodobisphenol A as one of the polymeric precursors and fluoranthene as template. In the presence of an oxygen scavenger, the iodide included in the polymeric structure induced efficient RTP emission from the analyte, once recognized by the MIP. The developed optosensing system has demonstrated a high specificity for fluoranthene against other polycyclic aromatic hydrocarbons. Detection limit for the target molecule was 35 ng/L (5-mL sample injections), and the linear range extended above 100 microg/L of the analyte. The polymer can be easily regenerated for subsequent sample injections (at least up to 450 cycles) with acetonitrile. The synthesized sensing material showed good stability for at least 6 months after preparation. The feasibility of monitoring fluoranthene in real samples was successfully evaluated through the analysis of five spiked river water samples.

Journal Article↗

Detection of transferrin isoforms in human serum: comparison of UV and ICP-MS detection after CZE and HPLC separations.

Two methods for separation of transferrin (Tf) sialoforms, capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) with conventional UV absorbance detection, have been investigated and compared. First, conditions affecting the separation of the Tf isoforms by capillary zone electrophoresis and HPLC were carefully optimized. The use of 15 mmol L(-1) borate buffer (pH 8.4) containing 3 mmol L(-1) diaminobutane (DAB) as additive enabled good separation of the Tf isoforms by CE (75 cm x 50 microm i.d. fused silica capillary) at 25 kV. In HPLC, a gradient of ammonium acetate (from 0 to 250 mmol L(-1) in 45 min) buffered at pH 6 (Tris-HCl) proved suitable for separation of Tf isoforms on a Mono-Q HR 5/5 anion-exchange column. On-line specific detection of the iron associated with the different Tf isoforms, after Fe saturation, by inductively coupled plasma mass spectrometry (ICP-MS) was studied in detail to compare its analytical performance with UV detection. For both CE and HPLC an octapole reaction system (ORS) ICP-MS instrument was used to minimize polyatomic interferences on the (56)Fe major isotope. Limits of detection of the different isoforms were in the range of 0.02-0.04 micromol L(-1) Tf for HPLC-ICP (ORS)-MS. This hybrid technique proved more selective and reliable detection of transferrin isoforms with 2, 3, 4, 5, and 6 sialic acid residues (S(2), S(3), S(4), S(5), and S(6)) in real serum samples. Interesting results from iron speciation of Tf in serum from healthy individuals and from pregnant women are given.

Chromatography, High Pressure Liquid↗

Isotope dilution GC-MS routine method for the determination of butyltin compounds in water.

A standard GC-MS instrument with electron impact ionisation has been used to develop a fast, simple and reliable method for the simultaneous determination of monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) in water samples. Isotope dilution analysis (IDA) is used for the determination of species, taking advantage of a commercially available spike solution containing a mixture of MBT, DBT and TBT enriched in 119Sn. Method detection limits for 100-mL samples were between 0.18 and 0.25 ng L(-1) for the three butyltin compounds with typical RSD between 2 and 4% at levels between 100 and 10 ng L(-1), respectively. Recovery of tin species in spiked samples (natural water, wastewater and seawater) was quantitative. The stability of butyltin compounds in collected seawater samples was also studied. The addition of a 1% (v/v) glacial acetic acid preserved tin species in the samples for at least 5 days at room temperature. The IDA method was finally implemented in a routine testing laboratory and it was subsequently accredited by the Spanish National Accreditation Body according to the requirements of UNE-EN ISO/IEC 17025.

Journal Article↗

Strategies to study human serum transferrin isoforms using integrated liquid chromatography ICPMS, MALDI-TOF, and ESI-Q-TOF detection: application to chronic alcohol abuse.

Variations in the distribution of sialoforms of human serum transferrin (Tf) in correlation with pathological states, which are associated with abnormalities in glycosylation, is of great clinical interest. In such studies, the methodologies of analysis are required to be sensitive and selective for observing small variations among isoforms and able to characterize the molecular structure of such forms. Thus, the present work describes, in the first part, the separation of transferrin isoforms, after iron saturation of the protein, by high-performance liquid chromatography (HPLC) and the on-line specific atomic detection of the iron present on each of the separated isoforms by on-line coupling the HPLC system to an inductively coupled plasma mass spectrometer (ICPMS). This allowed low detection levels for the different isoforms (L.D. 0.03 microMTf). After screening of the isoforms containing iron by ICPMS, structural characterization of each isoform can be independently carried out. Thus, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF) and electrospray mass spectrometry (ESI-Q-TOF) are compared in the second part of this study. The different atomic and molecular MS methods revealed the presence of elevated carbohydrate-deficient transferrin (CDT) isoforms in human serum samples from chronic alcohol consumption patients. MALDI-TOF appeared to be sensitive to concentration levels of the analytes, and the observed mass accuracy was highly compromised by the protein heterogeneity (peak width at half-maximum approximately 2000 Da for every fraction). On the other hand, ESI-Q-TOF allowed good mass accuracy (m < or = 0.05%) and peak width of 45 Da in the deconvoluted spectra; while ICPMS detection could be preferable for sensitive protein isoforms determinations, ESI-Q-TOF turns out to be an excellent "fingerprinting" technique for alcoholism diagnosis.

Alcoholism↗

Depth profiling with modified dc-Grimm and rf-Grimm-type glow discharges operated with high gas flow rates and coupled to a high-resolution mass spectrometer.

The improved analytical capability of direct-current (dc) and radiofrequency (rf) "fast flow" glow discharges coupled to a sector field mass spectrometer (GD-SFMS) are presented. In particular, the effect of GD chamber design has been studied to obtain suitable crater shapes for depth-profile analysis of solid samples while maintaining the high sensitivity and stability of this source. In this study it was observed that the distance between the sample surface and the end of the flow tube is critical and so careful optimisation is needed. Under optimum conditions plane crater profiles, with high ion-signal sensitivity and sufficient stability, were obtained. The capability to determine qualitative and semi-quantitative depth profiles is presented here using, as model, a coated sample of certified thickness. Finally, the depth resolution achieved for qualitative depth profiles obtained by rf-GD-(SF)MS is compared with that for the well-established rf-GD optical emission spectroscopy (OES) technique.

Chemical Phenomena↗

ICP-MS multielemental determination of metals potentially released from dental implants and articular prostheses in human biological fluids.

A sector field high-resolution (HR)-ICP-MS and an octapole reaction system (ORS)-ICP-MS have been compared for the simultaneous determination of traces of metals (Ti, V, Cr, Co, Ni, and Mo) released from dental implants and articular prostheses in human biological fluids. Optimum sample treatments were evaluated to minimize matrix effects in urine and whole blood. Urine samples were diluted tenfold with ultrapure water, whereas whole blood samples were digested with high-purity nitric acid and hydrogen peroxide and finally diluted tenfold with ultrapure water. In both matrices, internal standardization (Ga and Y) was employed to avoid potential matrix interferences and ICP-MS signal drift. Spectral interferences arising from the plasma gases or the major components of urine and whole blood were identified by (HR)-ICP-MS at 3,000 resolving power. The capabilities of (HR)-ICP-MS and (ORS)-ICP-MS for the removal of such spectral interferences were evaluated and compared. Results indicate that polyatomic interferences, which hamper the determination of such metallic elements in these biological samples, could be overcome by using a resolving power of 3,000. Using (ORS)-ICP-MS, all those elements could be quantified except Ti and V (due to the polyatomic ions 31P16O and 35Cl16O, respectively). The accuracy of the proposed methodologies by (HR)- and (ORS)-ICP-MS was checked against two reference materials. Good agreement between the given values and the concentrations obtained for all the analytes under scrutiny was found except for Ti and V when analyzed by (ORS)-ICP-MS.

Cartilage, Articular↗

Interpretation of butyltin mass spectra using isotope pattern reconstruction for the accurate measurement of isotope ratios from molecular clusters.

The fragmentation patterns of butyltin compounds (mono-, di-, and tributyltin) in an electron impact ion source were studied using an isotope pattern reconstruction algorithm with emphasis on isotope ratio measurements from molecular clusters. For this purpose, standards of natural tin isotope abundance and a (119)Sn-enriched mixture of the three compounds were both ethylated and propylated using sodium tetraalkylborates. The corresponding mass spectra of the various tetraalkyltin compounds prepared were obtained by GC/MS after their extraction with hexane. The results showed that pure interference-free molecular clusters were obtained only for certain R(3)Sn(+) ions where no isobaric overlap with R(2)SnH(+) ions occurred (e.g. BuEt(2)Sn(+) overlaps with Bu(2)SnH(+)). These ions are ideal candidates for accurate Sn isotope ratio measurements, while isotope pattern perturbing interferences are observed for other molecular fragments down to Sn(.)(+). Isotope pattern reconstruction algorithm thus can be used as an analytical tool to ensure the absence of molecular interferences--a requirement for accurate isotope ratio measurements from molecular clusters. The relevance of these studies for the determination of butyltin compounds in environmental samples by isotope dilution GC/MS is also discussed.

Environmental Monitoring↗