Search PubMed⌕ Search

Biomedical subjects

Alfred R Smith

Publications and source records attributed to Alfred R Smith.

5 recordsLinked to original sources

Proton therapy.

Proton therapy has become a subject of considerable interest in the radiation oncology community and it is expected that there will be a substantial growth in proton treatment facilities during the next decade. I was asked to write a historical review of proton therapy based on my personal experiences, which have all occurred in the United States, so therefore I have a somewhat parochial point of view. Space requirements did not permit me to mention all of the existing proton therapy facilities or the names of all of those who have contributed to proton therapy.

Health Physics↗

Treatment planning with protons for pediatric retinoblastoma, medulloblastoma, and pelvic sarcoma: how do protons compare with other conformal techniques?

PURPOSE: To calculate treatment plans and compare the dose distributions and dose-volume histograms (DVHs) for photon three-dimensional conformal radiation therapy (3D-CRT), electron therapy, intensity-modulated radiation therapy (IMRT), and standard (nonintensity modulated) proton therapy in three pediatric disease sites. METHODS AND MATERIALS: The tumor volumes from 8 patients (3 retinoblastomas, 2 medulloblastomas, and 3 pelvic sarcomas) were studied retrospectively to compare DVHs from proton therapy with 3D-CRT, electron therapy, and IMRT. In retinoblastoma, several planning techniques were analyzed: A single electron appositional beam was compared with a single 3D-CRT lateral beam, a 3D-CRT anterior beam paired with a lateral beam, IMRT, and protons. In medulloblastoma, three posterior fossa irradiation techniques were analyzed: 3D-CRT, IMRT, and protons. Craniospinal irradiation (which consisted of composite plans of both the posterior fossa and craniospinal components) was also evaluated, primarily comparing spinal irradiation using 3D-CRT electrons, 3D-CRT photons, and protons. Lastly, in pelvic sarcoma, 3D-CRT, IMRT, and proton plans were assessed. RESULTS: In retinoblastoma, protons resulted in the best target coverage combined with the most orbital bone sparing (10% was the mean orbital bone volume irradiated at > or =5 Gy for protons vs. 25% for 3D-CRT electrons, 69% for IMRT, 41% for a single 3D lateral beam, 51% for a 3D anterolateral beam with a lens block, and 65% for a 3D anterolateral beam without a lens block). A single appositional electron field was the next best technique followed by other planning approaches. In medulloblastoma, for posterior fossa and craniospinal irradiation, protons resulted in the least dose to the cochlea (for only posterior fossa irradiation at > or =20 Gy, 34% was the mean cochlear volume irradiated for protons, 87% for IMRT, 89% for 3D-CRT) and hypothalamus-pituitary axis (for only posterior fossa irradiation at > or =10 Gy, 21% was the mean hypothalamus-pituitary volume irradiated for protons, 81% for IMRT, 91% for 3D-CRT); additional dose reductions to the optic chiasm, eyes, vertebrae, mandible, thyroid, lung, kidneys, heart, and liver were seen. Intensity-modulated radiotherapy appeared to be the second best technique for posterior fossa irradiation. For spinal irradiation 3D-CRT electrons were better than 3D-CRT photons in sparing dose to the thyroid, heart, lung, kidney, and liver. With pelvic sarcoma, protons were superior in eliminating any dose to the ovaries (0% of mean ovarian volume was irradiated at > or =2 Gy with protons) and to some extent, the pelvic bones and vertebrae. Intensity-modulated radiotherapy did show more bladder dose reduction than the other techniques in pelvic sarcoma irradiation. CONCLUSIONS: In the diseases studied, using various techniques of 3D-CRT, electrons, IMRT, and protons, protons are most optimal in treating retinoblastomas, medulloblastomas (posterior fossa and craniospinal), and pelvic sarcomas. Protons delivered superior target dose coverage and sparing of normal structures. As dose-volume parameters are expected to correlate with acute and late toxicity, proton therapy should receive serious consideration as the preferred technique for the treatment of pediatric tumors.

Adolescent↗

Proton radiation therapy for retinoblastoma: comparison of various intraocular tumor locations and beam arrangements.

PURPOSE: To study the optimization of proton beam arrangements for various intraocular tumor locations; and to correlate isodose distributions with various target and nontarget structures. METHODS AND MATERIALS: We considered posterior-central, nasal, and temporal tumor locations, with straight, intrarotated, or extrarotated eye positions. Doses of 46 cobalt grey equivalent (CGE) to gross tumor volume (GTV) and 40 CGE to clinical target volume (CTV) (2 CGE per fraction) were assumed. Using three-dimensional planning, we compared isodose distributions for lateral, anterolateral oblique, and anteromedial oblique beams and dose-volume histograms of CTVs, GTVs, lens, lacrimal gland, bony orbit, and soft tissues. RESULTS: All beam arrangements fully covered GTVs and CTVs with optimal lens sparing. Only 15% of orbital bone received doses > or =20 CGE with a lateral beam, with 20-26 CGE delivered to two of three growth centers. The anterolateral oblique approach with an intrarotated eye resulted in additional reduction of bony volume and exposure of only one growth center. No appreciable dose was delivered to the contralateral eye, brain tissue, or pituitary gland. CONCLUSIONS: Proton therapy achieved homogeneous target coverage with true lens sparing. Doses to orbit structures, including bony growth centers, were minimized with different beam arrangements and eye positions. Proton therapy could reduce the risks of second malignancy and cosmetic and functional sequelae.

Humans↗

Benchmarking analytical calculations of proton doses in heterogeneous matter.

A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike varying density media. The purpose of this study was to determine the accuracy of our computational tool by comparing it with experimental and Monte Carlo (MC) simulation data as benchmarks. In the tests, parallel wide beams of protons were scattered in water phantoms containing embedded air and bone materials with simple geometrical forms and spatial dimensions of a few centimeters. For homogeneous water and bone phantoms, the proton doses we calculated with the ASPB algorithm were found very comparable to experimental and MC data. For layered bone slab inhomogeneity in water, the comparison between our analytical calculation and the MC simulation showed reasonable agreement, even when the inhomogeneity was placed at the Bragg peak depth. There also was reasonable agreement for the parallelepiped bone block inhomogeneity placed at various depths, except for cases in which the bone was located in the region of the Bragg peak, when discrepancies were as large as more than 10%. When the inhomogeneity was in the form of abutting air-bone slabs, discrepancies of as much as 8% occurred in the lateral dose profiles on the air cavity side of the phantom. Additionally, the analytical depth-dose calculations disagreed with the MC calculations within 3% of the Bragg peak dose, at the entry and midway depths in the phantom. The distal depth-dose 20%-80% fall-off widths and ranges calculated with our algorithm and the MC simulation were generally within 0.1 cm of agreement. The analytical lateral-dose profile calculations showed smaller (by less than 0.1 cm) 20%-80% penumbra widths and shorter fall-off tails than did those calculated by the MC simulations. Overall, this work validates the usefulness of our ASPB algorithm as a reasonably fast and accurate tool for quality assurance in planning wide beam proton therapy treatment of clinical sites either composed of homogeneous materials or containing laterally extended inhomogeneities that are comparable in density and located away from the Bragg peak depths.

Air↗

Proton beam dosimetry for radiosurgery: implementation of the ICRU Report 59 at the Harvard Cyclotron Laboratory.

Recent proton dosimetry intercomparisons have demonstrated that the adoption of a common protocol, e.g. ICRU Report 59, can lead to improved consistency in absorbed dose determinations. We compared absorbed dose values, measured in the 160 MeV proton radiosurgery beamline at the Harvard Cyclotron Laboratory, based on ionization chamber methods with those from a Faraday cup technique. The Faraday cup method is based on a proton fluence determination that allows the estimation of absorbed dose with the CEMA approximation, under which the dose is equal to the fluence times the mean mass stopping power. The ionization chamber technique employs an air-kerma calibration coefficient for 60Co radiation and a calculated correction in order to take into account the differences in response to 60Co and proton beam radiations. The absorbed dose to water, based on a diode measurement calibrated with a Faraday cup technique, is approximately 2% higher than was obtained from an ionization chamber measurement. At the Bragg peak depth, the techniques agree to within their respective uncertainties, which are both approximately 4% (1 standard deviation). The ionization chamber technique exhibited superior reproducibility and was adopted in our standard clinical practice for radiosurgery.

Algorithms↗