Search PubMed⌕ Search

Biomedical subjects

Alexandra J Lansky

Publications and source records attributed to Alexandra J Lansky.

At least 37 records · Page 2Linked to original sources

Safety of beta radiation exposure to the non-target segment: an intravascular ultrasound dosimetric analysis.

BACKGROUND: The use of longer radioactive seed trains to avoid geographic miss may lead to greater radiation exposure to distal vasculature due to the natural tapering of coronary arteries. The aim of this study was to use IVUS-based dosimetric analysis to evaluate the effect of beta-radiation on angiographically normal, noninjured distal segments. METHODS: We analyzed 17 in-stent restenosis cases (stent length: 20 +/- 8 mm) treated with a 40 mm 90Sr/Y source train. The prescribed dose was 18.4 Gy (reference less than or equal to 3.3 mm) or 23 Gy (reference > 3.3 mm) at 2 mm from the source. Noninjured, but fully radiated, distal reference sites were determined by angiography. Based upon the three-dimensional vessel contours obtained at baseline, the minimum dose delivered to 90% of plaque volume (Dv90) was determined. Vessel, plaque and lumen volumes and Dv90 were computed in every 2 mm subsegment (n = 52). RESULTS: On average, no significant serial change was observed in plaque area (5.0 +/- 2.5 mm3/mm post-treatment to 5.6 +/- 3.1 mm3/mm at 8-month follow up; p = 0.09), vessel area (10.2 +/- 3.7 to 10.3 +/- 4.0 mm3/mm; p = 0.84), or lumen area (5.2 +/- 2.0 to 4.7 +/- 1.8 mm3/mm; p = 0.19). Subsegment analysis, however, revealed a wide range of dose distribution, with a significant positive correlation between Dv90 and plaque increase (p = 0.008), as well as vessel change (p < 0.001), representing dose-dependent positive vessel remodeling following beta radiation. Consequently, no significant relationship was observed between Dv90 and lumen change. CONCLUSIONS: Detailed IVUS-based dosimetric analysis demonstrated that beta radiation promoted positive remodeling, preventing lumen loss despite a mild increase in plaque mass on angiographically normal, noninjured distal segments.

Aged↗

Bifurcation coronary lesions treated with the "crush" technique: an intravascular ultrasound analysis.

OBJECTIVES: We report intravascular ultrasound (IVUS) findings after crush-stenting of bifurcation lesions. BACKGROUND: Preliminary results with the crush-stent technique are encouraging; however, isolated reports suggest that restenosis at the side branch (SB) ostium continues to be a problem. METHODS: Forty patients with bifurcation lesions underwent crush-stenting with the sirolimus-eluting stent. Postintervention IVUS was performed in both branches in 25 lesions and only the main vessel (MV) in 15 lesions; IVUS analysis included five distinct locations: MV proximal stent, crush area, distal stent, SB ostium, and SB distal stent. RESULTS: Overall, the MV minimum stent area was larger than the SB (6.7 +/- 1.7 mm2 vs. 4.4 +/- 1.4 mm2, p < 0.0001, respectively). When only the MV was considered, the minimum stent area was found in the crush area (rather than the proximal or MV distal stent) in 56%. When both the MV and the SB were considered, the minimum stent area was found at the SB ostium in 68%. The MV minimum stent area measured <4 mm2 in 8% of lesions and <5 mm2 in 20%. For the SB, a minimum stent area <4 mm2 was found in 44%, and a minimum stent area <5 mm2 in 76%, typically at the ostium. "Incomplete crushing"--incomplete apposition of SB or MV stent struts against the MV wall proximal to the carina--was seen in >60% of non-left main lesions. CONCLUSIONS: In the majority of bifurcation lesions treated with the crush technique, the smallest minimum stent area appeared at the SB ostium. This may contribute to a higher restenosis rate at this location.

Angioplasty, Balloon, Coronary↗

Impact of in-hospital acquired thrombocytopenia in patients undergoing primary angioplasty for acute myocardial infarction.

Thrombocytopenia that develops after percutaneous coronary intervention (PCI) may result in hemorrhagic complications, requirement for blood product transfusions, and potentially thrombotic or ischemic complications. The incidence and prognostic significance of thrombocytopenia, in patients with acute myocardial infarction (AMI) who undergo primary PCI have not been evaluated. In the CADILLAC trial 2,082 patients who had AMI within 12 hours of onset without shock were prospectively randomized to receive balloon angioplasty with or without abciximab versus stenting with or without abciximab. Acquired thrombocytopenia, defined as a nadir platelet count <100 x 10(9)/L in patients who did not have baseline thrombocytopenia, developed in 50 of 1,975 qualifying patients (2.5%) after primary PCI. By multivariate analysis, acquired thrombocytopenia developed more frequently in patients who had non-insulin-requiring diabetes mellitus (odds ratio 3.88 [OR], p = 0.0002), previous statin administration (OR 3.28, p = 0.002), and use of abciximab (OR 2.06, p = 0.02) and less frequently in patients who had previous aspirin use (OR 0.26, p = 0.002), a higher baseline platelet count (OR 1.20, p < 0.0001), and greater body mass index (OR 0.90, p = 0.006). Patients who developed thrombocytopenia versus those who did not had higher in-hospital rates of major hemorrhagic complications (10.0% vs 2.7%, p = 0.01), greater requirement for blood transfusions (10.0% vs 3.9%, p = 0.05), longer hospital stay (median 4.8 vs 3.6 days, p = 0.008), and increased costs (median dollar 14,466 vs dollar 11,629, p = 0.001). All-cause mortality was markedly increased at 30 days (8.0% vs 1.6%, p = 0.0008) and at 1 year (10.0% vs 3.9%, p = 0.03) in patients who developed thrombocytopenia. In conclusion, thrombocytopenia that develops after primary PCI for AMI, although uncommon, is associated with increased hemorrhagic complications and decreased survival.

Abciximab↗

Impact and determinants of left ventricular function in patients undergoing primary percutaneous coronary intervention in acute myocardial infarction.

We evaluated the prognostic effect of baseline left ventricular function and the determinants of its recovery after acute myocardial infarction (AMI) treated by primary angioplasty. Left ventriculography was performed during the index procedure in 1,620 of 2,082 patients (78%) who underwent primary angioplasty for AMI in the CADILLAC trial. One-year survival rate was significantly lower in patients whose baseline left ventricular ejection fraction (LVEF) was <40% than in those whose LVEF was > or =40% (89.0% vs 97.2%, respectively, p <0.0001). The effect of baseline left ventricular dysfunction on mortality was confined to the first 3 months after AMI; thereafter, survival was independent of baseline LVEF. By multivariate analysis, baseline LVEF (hazard ratio 0.93, 95% confidence interval 0.90 to 0.97, p <0.001) and infarct zone regional wall motion (hazard ratio 2.67, 95% confidence interval 1.08 to 6.63, p = 0.03) were independent predictors of 1-year mortality. Seven-month convalescent LVEF was also directly related to baseline LVEF and inversely correlated with previous AMI, multivessel coronary disease, preprocedural Thrombolysis In Myocardial Infarction grade 0 to 2 flow, larger infarct artery diameter, and infarct artery restenosis at follow-up. In conclusion, baseline left ventricular function measured during the index procedure is a strong independent predictor of early and late survival after primary angioplasty. Simple clinical and angiographic features readily available at the time of primary angioplasty also predict convalescent LVEF and are thus of prognostic utility.

Aged↗

Intravascular ultrasound study of patterns of calcium in ruptured coronary plaques.

Coronary calcium is intimately associated with coronary atherosclerotic plaque development, although it is controversial as to whether coronary calcium is associated with plaque instability. We analyzed 101 IVUS-detected ruptured plaques and compared them with 101 computer-matched control plaques without evidence of plaque rupture. The arc of calcium was measured every 0.5 mm within 10-mm-long segments that spanned the minimum lumen cross-sectional area, and the number and length of calcium deposits were assessed. Ruptured plaques had a significantly larger number of individual calcium deposits than control plaques (3.5 +/- 1.7 vs 1.8 +/- 1.1, p <0.001). However, the arc of the largest calcium deposit was smaller and the length of the largest calcium deposit in each plaque was shorter in ruptured plaques compared with control plaques (67.3 degrees +/- 41.4 degrees vs 114.9 degrees +/- 77.4 degrees , p <0.001, and 1.6 +/- 1.3 vs 4.0 +/- 2.7 mm, p <0.001, respectively). There was no difference in the number of superficial calcium deposits between the 2 groups, although ruptured plaques had significantly smaller arcs of superficial calcium compared with control plaques (56.2 degrees +/- 35.5 degrees vs 95.8 degrees +/- 65.2 degrees , p <0.001). Conversely, the number of deep calcium deposits was significantly larger in ruptured plaques than in control plaques (1.8 +/- 1.4 vs 0.3 +/- 0.6, p <0.001), although the arc of deep calcium was similar in the 2 groups. Ruptured plaques had quantitatively less calcium, especially superficial calcium, but a larger number of small calcium deposits, especially deep calcium deposits. In conclusion, ruptured plaques are associated with a larger number of calcium deposits within an arc of <90 degrees , a larger number of deep calcium deposits, and a remodeling index.

Aged↗

Intravascular ultrasonic assessment of stent diameters derived from manufacturer's compliance charts.

We used intravascular ultrasound (IVUS) to assess the accuracy of manufacturers' stent balloon compliance charts. Many interventional cardiologists rely on manufacturers' compliance charts to select stent size and optimize stent diameters according to inflation pressures during percutaneous procedures. We randomly selected 212 patients who had de novo coronary lesions that had been treated with a single, bare metal, > or =3.0-mm stent (Bx velocity, NIR, TETRA/PENTA, S660/S670/S7) under IVUS guidance. Cases of stent overlap and postdilatation with another balloon were excluded. Predicted stent diameters were derived from each manufacturer's compliance charts, and stent size and final maximal deployment pressures were derived from each physician's report. IVUS-measured minimum stent diameters (range 1.4 to 4.0 mm, mean 2.79 +/- 0.48) were smaller than predicted diameters (range 3.1 to 4.57 mm, mean 3.79 +/- 0.44). The ratio of IVUS to predicted diameters ranged from 44% to 97% (mean 74 +/- 10%). This finding was common to all 3 stent sizes: 74 +/- 12% for 3.0 mm, 73 +/- 9% for 3.5 mm, and 74 +/- 9% for 4.0-mm stents (p = 0.9). This finding was also common to all 4 stent manufacturers, 72 +/- 8% for Boston Scientific, 76 +/- 11% for Guidant, 73 +/- 9% for Cordis, and 74 +/- 11% for Medtronic (p = 0.13), and to different stent lengths. Only 3.8% of the stents achieved 90% of the predicted minimum stent diameters, and only 24.6% achieved 80% of the predicted minimum stent diameters. In conclusion, in human coronary arteries, minimal stent diameter measured by IVUS is significantly smaller than that predicted by in vitro compliance charts. These differences are independent of stent manufacturer, length, diameter, and deployment pressure.

Aged↗

Prediction of mortality after primary percutaneous coronary intervention for acute myocardial infarction: the CADILLAC risk score.

OBJECTIVES: We sought to develop a simple risk score for predicting mortality after primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). BACKGROUND: Accurate risk stratification after primary PCI is important. Previous risk scores after reperfusion therapy have incorporated clinical +/- angiographic variables but have not considered baseline left ventricular function. Moreover, prior studies have not been validated against independent databases or studies. METHODS: The databases from the two largest multicenter, randomized AMI trials of primary PCI were utilized for score derivation (the Controlled Abciximab and Device Investigation to Lower Late Angioplasty Complications [CADILLAC] trial, n = 2,082) and subsequent validation (the Stent-Primary Angioplasty in Myocardial Infarction [Stent-PAMI] trial, n = 900). Logistic regression and the jackknife procedure were used to select correlates of one-year mortality that were subsequently weighted and integrated into an integer scoring system. RESULTS: Seven variables selected from the initial multivariate model were weighted proportionally to their respective odds ratio for one-year mortality (age >65 years [2 points], Killip class 2/3 [3 points], baseline left ventricular ejection fraction <40% [4 points], anemia [2 points], renal insufficiency [3 points], triple-vessel disease [2 points], and post-procedural Thrombolysis In Myocardial Infarction flow grade [2 points]). Three strata of risk were defined (low risk, score 0 to 2; intermediate risk, score 3 to 5; and high risk, score >/=6) with excellent prognostic accuracy for survival in the derivation and validation sets (c statistics = 0.83 and 0.81 for 30-day mortality and 0.79 and 0.78 for 1-year mortality, respectively). CONCLUSIONS: In AMI patients treated with primary PCI, seven risk factors readily available at the time of intervention accurately predict short- and long-term mortality. Of note, measurement of baseline left ventricular function is the single most powerful predictor of survival and should be incorporated into risk score models.

Aged↗

Gender-based outcomes after paclitaxel-eluting stent implantation in patients with coronary artery disease.

OBJECTIVES: We sought to determine whether gender influences the results of paclitaxel-eluting stent implantation. BACKGROUND: The TAXUS-IV trial demonstrated the safety and effectiveness of the slow-release, polymer-based, paclitaxel-eluting TAXUS stent compared to bare-metal stents in patients undergoing elective coronary intervention. Whether these results are generalizable to women is not known. METHODS: A total of 1,314 patients with coronary lesions 10- to 28-mm long in 2.5- to 3.75-mm vessels were randomized to TAXUS stent versus bare-metal EXPRESS stents (Boston Scientific Corp., Natick, Massachusetts). Outcomes examined were stratified by gender. RESULTS: A total of 662 patients (including 187 women) were assigned to the TAXUS stent, and 652 (180 women) received the control stent. Women were older than men, and had more hypertension, diabetes, renal insufficiency, unstable angina, and heart failure, but less smoking. Among patients receiving the TAXUS stent, women compared with men had higher unadjusted one-year rates of target lesion revascularization (TLR) (7.6% vs. 3.2%, p = 0.03), though female gender was not an independent predictor of TLR (odds ratio [OR] = 1.72 [95% confidence interval (CI) 0.68 to 4.37], p = 0.25). Moreover, restenosis rates were similar in men and women treated with the TAXUS stent (8.6% vs. 7.6%, respectively, p = 0.80), as was late loss (0.22 vs. 0.23 mm, p = 0.90). Compared to control stents, treatment with the TAXUS stent in women resulted in a significant reduction in nine-month restenosis (8.6% vs. 29.2%, p = 0.0001) and one-year TLR (7.6% vs. 14.9%, p = 0.02). The only independent predictor of freedom from restenosis in women was randomization to the TAXUS stent (OR = 0.28 [95% CI 0.11 to 0.74], p = 0.01). CONCLUSIONS: The benefits of the paclitaxel-eluting stent in reducing clinical and angiographic restenosis are generalizable to women.

Age Factors↗

Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study.

OBJECTIVES: We sought to determine the predictors of stent thrombosis after sirolimus-eluting stent (SES) implantation. BACKGROUND: A number of cases of stent thrombosis have been reported after commercial release of the SES in the "real world," such that the U.S. Food and Drug Administration issued a warning. METHODS: Fifteen patients who developed stent thrombosis after successful SES implantation were analyzed and compared with 45 matched control patients who had no evidence of stent thrombosis. RESULTS: Minimum stent cross-sectional area (MSA) (4.3 +/- 1.6 mm(2) vs. 6.2 +/- 1.9 mm(2), p < 0.001) and stent expansion (0.65 +/- 0.18 vs. 0.85 +/- 0.14, p < 0.001) were significantly smaller in the stent thrombosis group than in the matched control patients. There was no significant difference in the rate of SES malapposition between the groups. However, the presence of a significant residual reference segment stenosis was more common in the stent thrombosis group compared with the matched control group (67% vs. 9%, p < 0.001). Independent predictors of stent thrombosis were stent underexpansion (p = 0.03) and a significant residual reference segment stenosis (p = 0.02). CONCLUSIONS: Stent underexpansion and residual reference segment stenosis are associated with stent thrombosis after successful SES implantation.

Aged↗

Gender differences in outcomes after primary angioplasty versus primary stenting with and without abciximab for acute myocardial infarction: results of the Controlled Abciximab and Device Investigation to Lower Late Angioplasty Complications (CADILLAC) trial.

BACKGROUND: Women with acute myocardial infarction (AMI) undergoing primary angioplasty have higher rates of morbidity and mortality than do men. Whether contemporary interventional treatment strategies have improved outcomes for women compared with men is unknown. METHODS AND RESULTS: In the CADILLAC trial, 2082 patients (27% women) with AMI within 12 hours of symptom onset were randomized to balloon angioplasty (PTCA; n=518), PTCA+abciximab (n=528), stenting (n=512), and stenting+abciximab (n=524). As compared with men, women had a lower body surface area; had a greater prevalence of diabetes, hypertension, and hyperlipidemia; experienced significant delays to treatment; and had better baseline and final TIMI grade 3 flows. Unadjusted 1-year event rates were higher for women, including death (7.6% versus 3.0%, P<0.001), ischemic target-vessel revascularization (TVR; 16.7% versus 12.1%, P=0.006), and major adverse cardiac events (MACE; 23.9% versus 15.3%, P<0.001). Female gender was an independent predictor of MACE and bleeding complications, although comorbid risk factors and body surface area but not gender predicted 1-year death. For women, primary stenting resulted in a reduction in 1-year MACE from 28.1% to 19.1% (P=0.01) and in ischemic TVR from 20.4% to 10.8% (P=0.002) compared with PTCA. The addition of abciximab to primary stenting significantly reduced the 30-day ischemic TVR without increasing bleeding or stroke rates. CONCLUSIONS: The higher mortality rate in women compared with men after interventional treatment for AMI may be explained by differences in body size and clinical risk factors, although female gender remains an important independent determinant of overall adverse outcomes. For women in the CADILLAC trial, the addition of abciximab reduced 30-day TVR without increasing bleeding risk, and primary stenting reduced 1-year TVR and MACE rates compared with PTCA.

Abciximab↗

Distal microcirculatory protection during percutaneous coronary intervention in acute ST-segment elevation myocardial infarction: a randomized controlled trial.

CONTEXT: Atheromatous and thrombotic embolization during percutaneous coronary intervention (PCI) in acute myocardial infarction is common and may result in microcirculatory dysfunction, the prevention of which may improve reperfusion success, reduce infarct size, and enhance event-free survival. OBJECTIVE: To determine whether protection of the distal microcirculation from thromboembolic debris liberated during primary PCI results in improved reperfusion and decreased infarct size. DESIGN, SETTING, AND PATIENTS: Prospective randomized controlled trial at 38 academic and community-based institutions in 7 countries enrolling 501 patients aged 18 years or older with ST-segment elevation myocardial infarction (STEMI) presenting within 6 hours of symptom onset and undergoing primary PCI or rescue intervention after failed thrombolysis. INTERVENTIONS: Patients were randomized between May 20, 2002, and November 21, 2003, to receive PCI with a balloon occlusion and aspiration distal microcirculatory protection system vs angioplasty without distal protection. MAIN OUTCOME MEASURES: Coprimary end points were ST-segment resolution (STR) measured 30 minutes after PCI by continuous Holter monitoring and infarct size measured by technetium Tc 99m sestamibi imaging between days 5 and 14. Secondary end points included major adverse cardiac events. RESULTS: Among 252 patients assigned to distal protection, aspiration was performed in 97% (242/251), all angioplasty balloon inflations were fully protected in 79% (193/245), and visible debris was retrieved from 73% (182/250). Complete STR was achieved in a similar proportion reperfused with vs without distal protection (63.3% [152/240] vs 61.9% [148/239], respectively; absolute difference, 1.4% [95% confidence interval, -7.7% to 10.5%; P = .78]), and left ventricular infarct size was similar in both groups (median, 12.0% [n = 229] vs 9.5% [n = 208], respectively; P = .15). Major adverse cardiac events at 6 months occurred with similar frequency in the distal protection and control groups (10.0% vs 11.0%, respectively; P = .66). CONCLUSIONS: A distal balloon occlusion and aspiration system effectively retrieves embolic debris in most patients with acute STEMI undergoing emergent PCI. Nonetheless, distal embolic protection did not result in improved microvascular flow, greater reperfusion success, reduced infarct size, or enhanced event-free survival.

Aged↗

Combined prognostic utility of ST-segment recovery and myocardial blush after primary percutaneous coronary intervention in acute myocardial infarction.

AIMS: ST-segment recovery (SigmaSTR) and myocardial blush (MB) evaluate different elements of microcirculatory integrity after reperfusion therapy in acute myocardial infarction (AMI). We sought to determine whether the combination of SigmaSTR and MB after primary percutaneous coronary intervention (PCI) in AMI has greater prognostic utility than either measure alone. METHODS AND RESULTS: The 30 days and 1 year clinical outcomes of 456 patients were assessed as a function of SigmaSTR and MB after primary PCI from the CADILLAC trial. SigmaSTR and MB were concordant (> or =70% SigmaSTR and MB grade 2/3 or <70% SigmaSTR and MB grade 0/1) in 60.1% of patients and discordant in 39.9% of patients. The greatest survival was observed among patients with complete SigmaSTR (> or =70%) and MB grade 2/3 in whom the cumulative rates of death at 30 days and 1 year were 0.6 and 1.2%, respectively. Poorest survival was observed among patients with incomplete SigmaSTR (<70%) and reduced MB (grade 0/1), in whom 30 days and 1 year rates of death were 8.3 and 10.1%, respectively. Intermediate outcomes were present in patients with discordant MB and SigmaSTR. By multivariable analysis, however, SigmaSTR was an independent correlate of survival at 30 days and 1 year (P=0.05 and 0.01, respectively), whereas MB was no longer predictive (P=0.38 and 0.72, respectively). CONCLUSION: SigmaSTR and MB are not infrequently discordant after primary PCI. By univariate analysis, both measures of reperfusion success strongly correlate with survival and assessment of both yields incremental prognostic information beyond either measure alone. By multivariable analysis, however, SigmaSTR is the stronger prognostic variable.

Aged↗

Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation.

Intravascular ultrasound (IVUS) evaluation was performed in 33 lesions with sirolimus-eluting stent (SES) failure: 4 thromboses, 26 in-stent restenoses (including 6 edge stenoses), 4 new stenoses >5 mm proximal to the stent, and 1 patient with no evidence of the implanted SES (presumably because of embolization). A minimum stent area <5.0 mm(2) (stent underexpansion) was observed in 67% of all SES failures (in particular, 67% of intrastent restenosis); negative remodeling was observed in 4 of 6 stent edge restenoses, and new lesions were secondary to an increase in plaque area.

Coronary Restenosis↗

Impact of diabetes mellitus on myocardial perfusion after primary angioplasty in patients with acute myocardial infarction.

OBJECTIVES: We investigated the impact of diabetes mellitus on myocardial perfusion after primary percutaneous coronary intervention (PCI) utilizing myocardial blush grade (MBG) and ST-segment elevation resolution (STR). BACKGROUND: Diabetes is an independent predictor of outcomes after primary PCI for acute myocardial infarction (AMI). Whether the poor prognosis is due to lower rates of myocardial reperfusion is unknown. METHODS: Reperfusion success in those with and without diabetes mellitus was determined by measuring MBG (n = 1,301) and STR analysis (n = 700) in two substudies of the Controlled Abciximab and Device Investigation to Lower Late Angioplasty Complications (CADILLAC) trial among patients undergoing primary PCI for AMI. RESULTS: There were no differences between those with or without diabetes with regard to postprocedural Thrombolysis In Myocardial Infarction (TIMI) flow grade 3 (>95%), distribution of infarct-related artery, and the frequency of stent deployment or abciximab administration. Patients with diabetes mellitus were more likely to have absent myocardial perfusion (MBG 0/1, 56.0% vs. 47.1%, p = 0.01) and absent STR (20.3% vs. 8.1%, p = 0.002). Diabetes mellitus (hazard ratio [HR] 1.63 [95% confidence interval (CI) 1.17 to 2.28], p = 0.004) was an independent predictor of absent myocardial perfusion (MBG 0/1) and absent STR (HR 2.94 [95% CI 1.64 to 5.37], p = 0.005) by multivariate modeling. CONCLUSIONS: Despite similar high rates of TIMI flow grade 3 after primary PCI in patients with and without diabetes, patients with diabetes are more likely to have abnormal myocardial perfusion as assessed by both incomplete STR and reduced MBG. Diminished microvascular perfusion in diabetics after primary PCI may contribute to adverse outcomes.

Angioplasty, Balloon, Coronary↗

Creatine kinase-MB enzyme elevation and long-term clinical events after successful coronary stenting in lesions with ruptured plaque.

Patients with acute coronary syndrome are at increased risk of acute and long-term events after stent implantation. We compared the impact of intravascular ultrasound detected plaque rupture on creatine kinase-MB (CK-MB) isoenzyme release and clinical outcomes by comparing 62 patients with ruptured plaques with 62 matched control patients who underwent stent implantation. Two thirds of the patients in each group presented with an acute coronary syndrome. There were no differences in procedural complications between groups, although patients with ruptured plaque had higher CK-MB elevation rates than those without ruptured plaque (1 to 3 times the upper limit of normal CK-MB, 35% vs 10%, p <0.001; >3 times the upper limit, 15% vs 2%, p = 0.02). Independent predictors of CK-MB elevation were presence of ruptured plaque (p = 0.03) and unstable angina (p = 0.04). Patients with ruptured plaque had higher composite rates of late events (target lesion revascularizations/myocardial infarctions/cardiac deaths) than controls (25% vs 9%, p = 0.03). These results were similar when only patients with acute coronary syndrome were studied. Plaque rupture morphology is associated with higher periprocedural CK-MB release and worse 1-year clinical outcome in patients treated with coronary stenting.

Analysis of Variance↗

Percutaneous coronary intervention and adjunctive pharmacotherapy in women: a statement for healthcare professionals from the American Heart Association.

More than 1.2 million percutaneous coronary interventions are performed annually in the United States, with only an estimated 33% performed in women, despite the established benefits of percutaneous coronary intervention and adjunctive pharmacotherapy in reducing fatal and nonfatal ischemic complications in acute myocardial infarction and high-risk acute coronary syndromes. This statement reviews sex-specific data on the safety and efficacy of contemporary interventional therapies in women.

Angioplasty, Balloon, Coronary↗

Impact of stenting and abciximab in patients with diabetes mellitus undergoing primary angioplasty in acute myocardial infarction (the CADILLAC trial).

We sought to determine the benefits of stent implantation and abciximab in patients with diabetes mellitus and acute myocardial infarction (AMI) who underwent primary angioplasty. In a 2-by-2 factorial design, 2,082 patients with AMI were randomly assigned to balloon angioplasty versus stenting, with or without abciximab. Diabetes was present in 346 patients (16.6%). The primary end point was the composite incidence of death, disabling stroke, reinfarction, and ischemic target vessel revascularization (TVR). The primary end point at 1 year occurred significantly more frequently in diabetic than nondiabetic patients (21.9% vs 16.8%, p <0.02), driven by increased rates of death (6.1% vs 3.9%, p = 0.04) and TVR (16.4% vs 12.7%, p = 0.07). Among patients with diabetes, TVR at 1 year was significantly reduced with routine stenting compared with balloon angioplasty (10.3% vs 22.4%, p = 0.004), with no differences in death, reinfarction, or stroke. Angiographic restenosis was also greatly reduced in diabetics randomized to stenting (21.1% vs 47.6%, p = 0.009). No beneficial effects were apparent with abciximab in diabetic patients at 1 year. Despite the improved outcomes with stenting in patients with diabetes, 1-year mortality remained increased in diabetic patients who received stents compared with nondiabetics (8.2% vs 3.6%, p = 0.005). Thus, routine stent implantation in diabetic patients with AMI significantly reduces restenosis and enhances survival free from TVR, independent of abciximab use, although survival remains reduced compared with survival in nondiabetic patients regardless of reperfusion modality.

Abciximab↗

Contrast-induced nephropathy after percutaneous coronary interventions in relation to chronic kidney disease and hemodynamic variables.

We previously found that contrast-induced nephropathy (CIN) complicating percutaneous coronary intervention adversely affects patients with chronic kidney disease (CKD). Therefore, we further investigated whether the predictors and outcome of CIN after percutaneous coronary intervention differ among patients with versus without CKD. Among 7,230 consecutive patients, CIN (>or=25% or >or=0.5 mg/dl increase in preprocedure serum creatinine 48 hours after the procedure) developed in 381 of 1,980 patients (19.2%) with baseline CKD (estimated glomerular filtration rate [eGFR] <60 ml/min/1.73 m(2)) and in 688 of 5,250 patients (13.1%) without CKD. Decreased eGFRs, periprocedural hypotension, higher contrast media volumes, lower baseline hematocrit, diabetes, pulmonary edema at presentation, intra-aortic balloon pump use, and ejection fraction <40% were the most significant predictors of CIN in patients with CKD. Apart from intra-aortic balloon pump use, predictors of CIN in patients without CKD were the same as mentioned, plus older age and type of contrast media. Regardless of baseline renal function, CIN correlated with longer in-hospital stay and higher rates of in-hospital complications and 1-year mortality compared with patients without CIN. By multivariate analysis, CIN was 1 of the most powerful predictors of 1-year mortality in patients with preexisting CKD (odds ratio 2.37, 95% confidence interval 1.63 to 3.44) or preserved eGFR (odds ratio 1.78; 95% confidence interval 1.22 to 2.60). Thus, regardless of the presence of CKD, baseline characteristics and periprocedural hemodynamic parameters predict CIN, and this complication is associated with worse in-hospital and 1-year outcomes.

Aged↗