Search PubMed⌕ Search

Biomedical subjects

Alessandro Ghidini

Publications and source records attributed to Alessandro Ghidini.

42 records · Page 3Linked to original sources

Factors affecting the decision regarding amniocentesis in women at genetic risk because of age 35 years or older.

OBJECTIVE: To evaluate the effects of anamnestic factors and sonographic findings on the patient's decision regarding amniocentesis in a cohort of women at genetic risk because of advanced age. METHODS: All women 35 years of age or older registered for prenatal care between January 1990 and December 1998 were asked about their attitude towards genetic amniocentesis during the course of individual genetic counseling and once again after ultrasound examination inclusive of markers of aneuploidies (nuchal fold thickness greater than 6 mm, renal pyelectasis, choroid plexus cysts, and hyperechogenic bowel). Their attitudes towards genetic amniocentesis before and after ultrasound examination were compared using chi-square, Fisher's exact test, Mann-Whitney U-test, and logistic regression analysis, with a two-tailed p < 0.05 or an odds ratio (OR) with 95% confidence interval (CI) not inclusive of the unity considered significant. RESULTS: Among the 1486 women in the cohort, 1368 (97%) expressed an opinion towards genetic testing at the time of counseling: 501 (37%) were in favor and 867 (63%) were against having the procedure. After ultrasonographic examination, 33% (446/1368) of women opted for amniocentesis, 36% (146/402) after abnormal findings and 31% (300/966) after normal ultrasound findings. Significantly more women with abnormal than normal ultrasound findings opted for diagnostic testing in both groups. Overall, only 8% (115/1368) of women changed their attitude towards diagnostic testing after ultrasonographic examination. Normal sonographic findings were three times more likely to change the attitude of women initially interested in amniocentesis than abnormal sonographic findings did in women a priori not interested in the procedure (20% versus 7%, p < 0.001, OR = 3.2, 95% CI 1.8; 5.8). CONCLUSIONS: In a cohort of women at genetic risk because of advanced age, the key determinant of the choice regarding genetic amniocentesis is the a priori opinion of the woman towards the procedure, which was expressed by 93% of women. Ultrasonography plays a secondary role in changing or confirming women's attitude towards invasive diagnostic testing. Normal sonographic findings affect women's decisions more powerfully than abnormal sonographic findings, suggesting that ultrasonography has an important reassuring function for the woman.

Adult↗

Impact of different prevention strategies on neonatal group B streptococcal disease.

The objective of this paper is to evaluate the effect of different prevention strategies on the rate of early-onset neonatal group B streptococcus (GBS) disease and mortality. We compared the neonatal mortality and morbidity rates associated with early-onset GBS disease in three periods characterized by different prevention strategies, including no screening for GBS during pregnancy and no standardized chemoprophylaxis (1/1987 to 12/1990), antibiotic prophylaxis only with risk factors for GBS (1/1991 to 12/1994), and universal screening for GBS with rectovaginal cultures and chemoprophylaxis for women with positive results or risk factors (1/1995 to 12/1999). Statistical analysis included Fisher's exact test and Chi-square, with a two-tailed p <0.05 considered significant. The yearly prevalence of positive GBS cultures was similar throughout the screening period (mean 18%, range 16 to 19%). Compared with the no prophylaxis group (rate = 4/8,573), introduction of universal screening (rate = 0/13,754, p = 0.02) but not of prophylaxis for risk factors alone (rate = 1/10,303, p = 0.18) significantly decreased the occurrence of GBS-specific neonatal mortality. Universal screening decreased, though not significantly, the GBS-specific neonatal morbidity rates compared with a policy based on risk factors alone (0.4/1000 vs. 0.8/1000, p = 0.29). Our study had a power to detect a 0.7/1000 difference in the rate of specific morbidity between the two chemoprophylaxis policies (alpha = 0.05, beta= 0.80). Intrapartum prophylaxis for GBS, using universal screening or risk factors, is associated with a significant reduction in the specific neonatal mortality rate compared with no prophylaxis. Universal screening for GBS leads to a decrease in specific GBS morbidity compared with screening using risk factors alone.

Adult↗

Correlating head-to-body delivery intervals with neonatal depression in vaginal births that result in permanent brachial plexus injury.

OBJECTIVE: The purpose of this study was to evaluate which variables predict neonatal depression in vaginal deliveries that result in permanent brachial plexus injury. STUDY DESIGN: With the use of a data set of litigated vaginal deliveries (n = 103 deliveries) from 1978 through 1999 that resulted in permanent brachial plexus injury, detailed delivery and neonatal and pediatric information was obtained by chart review. Neonatal depression was defined as a 5-minute Apgar score of <7. Data that were extrapolated from neonates with low Apgar scores at 5 minutes were compared with neonates with Apgar scores of > or =7 with the use of the Fisher exact test, chi(2) test, or one-way analysis of variance; a two-tailed probability value of <.05 was considered significant. RESULTS: Nine of 89 neonates (10%) had low 5-minute Apgar scores. Head-to-body delivery intervals (available for 36 deliveries) were significantly longer in neonates with 5-minute Apgar scores of <7 vs > or =7 (294 +/- 68 seconds vs 147 +/- 82 seconds, P <.001). Differences in other clinical variables (ie, maternal weight, gestational age, diabetes mellitus, parity, birth weight, and sex) were not significant. None of the infants in this data set, which includes those infants with neonatal depression) died or had long-term asphyxia-related sequelae in the form of speech impediments, seizures, cerebral palsy, coma, or organ dysfunction. CONCLUSION: The head-to-body delivery interval was the only significant factor in the prediction of 5-minute Apgar score of <7 in a data set of deliveries that resulted in permanent brachial plexus injury. Despite extended times (< or =6 minutes) on the perineum that resulted in a higher reduced Apgar score rate, there was no asphyxia-related morbidity.

Apgar Score↗

Prognostic value of uterine artery Doppler velocimetry in growth-restricted fetuses delivered near term.

OBJECTIVE: We have investigated the use of uterine artery Doppler waveform analysis in growth restricted fetuses delivered at > or =34 weeks. STUDY DESIGN: Included in the study were all consecutive euploid non-malformed singleton fetuses with accurate dating diagnosed as growth restricted (sonographic abdominal circumference <10th percentile) between January 1995 and December 1998 and who were delivered at > or =34 weeks. Delivery was expedited for biophysical profile 6 or less with nonreactive nonstress test, preeclampsia, oligohydramnios, absent fetal growth over 2 weeks, absent or reversed diastolic flow in the umbilical artery (UA), or UA pulsatility index (PI) greater than the 95th percentile after 37 weeks. Neonatal outcomes were compared in cases with normal versus abnormal Doppler waveforms at the uterine arteries (defined as average resistance index >0.58 or presence of bilateral notching) using one-way analysis of variance, chi(2) test, and logistic regression analysis. A two-tailed P <.05 or an odds ratio (OR) with 95% CI not inclusive of the unity was considered significant. RESULTS: Growth-restricted fetuses with abnormal (n = 109) versus normal (n = 185) Doppler velocimetry results at the uterine arteries had similar ratios of head-to-abdominal circumference at diagnosis, but asymmetric body proportion at the last scan before delivery. Neonates of mothers with abnormal uterine artery Doppler waveforms were more frequently born of cesarean delivery, particularly for non-reassuring fetal testing (27% vs 10%, P <.001), had significantly lower gestational age at delivery (37.7 +/- 2.0 vs 38.8 +/- 1.6, P <.001), and lower birth weight percentiles (4.8 +/- 5.1 vs 9.3 +/- 10.2, P <.001). More importantly, although 5-minute Apgar scores and UA pH values were not significantly lower, they had a significantly greater risk of admission to intensive care unit for reasons other than low birth weight alone (36% vs 11%). After preeclampsia was controlled, such risk was associated with an OR of 4.1 (95% CI 2.2-7.5). CONCLUSION: In growth-restricted fetuses delivered at > or =34 weeks, presence of abnormal Doppler waveforms at the uterine arteries at diagnosis is associated with a 4-fold increased risk of adverse neonatal outcome.

Adult↗

Caveats for the use of humerus length in the prediction of fetal Down syndrome.

OBJECTIVE: To assess the reliability and reproducibility of fetal humerus length in the diagnosis of trisomy 21. METHODS: Cohort study inclusive of 22 trisomy 21 fetuses, who underwent ultrasonographic examination between 14 and 22 weeks' gestation, and 457 euploid controls. Regression analysis was performed for humerus length as function of biparietal diameter. Based on the generated regression equation in euploid fetuses, expected values of humerus length for a given biparietal diameter were calculated. The ratios of observed to expected (O/E) humerus length values were compared between euploid and trisomy 21 fetuses using Student's t test. Receiver operating characteristic (ROC) curve analysis was used to detect optimal thresholds of O/E humerus length for diagnosis of trisomy 21. In addition, a MEDLINE search was conducted for articles published on humerus length as predictor of trisomy 21. RESULTS: No differences were present between the regression lines of trisomy 21 and euploid fetuses (mean +/- standard deviation O/E humerus length in euploid and aneuploid fetuses: 1.00 +/- 0.10 vs. 0.97 +/- 0.11, p = 0.21). The optimal threshold O/E humerus length <0.88 identified by ROC curve analysis had a sensitivity of 18% and a false-positive rate of 9% for the diagnosis of trisomy 21. From a review of the evidence provided by the 17 published series on humerus length as predictor of Down syndrome, the following caveats emerge: (1) with a median false-positive rate of 5% (range 1-12%), the median sensitivity of humerus length was only 28% (range 15-64%); (2) differences were present among centers in the regression lines of euploid fetuses and in the optimal diagnostic thresholds of humerus length, suggesting inter-center variability, and (3) most populations studied were at high genetic risk for trisomy 21, hence the diagnostic ability of humerus length in low risk populations has not been tested. CONCLUSIONS: The ability of humerus length to predict trisomy 21 is inconsistent. Only institutions with locally generated regression equations and documented predictive ability of this marker should utilize humerus length as a screening test for trisomy 21, alone or incorporated into diagnostic algorithms with serum or other sonographic markers of trisomy 21. The diagnostic ability of humerus length in low risk populations is currently unknown.

Adult↗

Prognostic value of change in amniotic fluid color during labor.

OBJECTIVE: Evidence of meconium-stained amniotic fluid (AF) during labor suggests implementation of close monitoring of fetal well-being. We have investigated whether the presence of meconium in the AF on admission for labor is as important a predictor of neonatal outcome as a change in AF color during labor. METHODS: AF characteristics on admission for labor at term (37-42 weeks) and their changes during labor were recorded in all singleton pregnancies during an 8-year period (1992-1999). Excluded were stillbirths on admission, congenital anomalies, and elective cesarean sections. The presence of meconium and its consistency (light or thick) were documented on admission by inspection with transcervical amnioscopy in women with intact membranes or in the vaginal pool in those with ruptured membranes. Changes in AF color or consistency during labor were recorded and correlated with the obstetric and neonatal outcome. Statistical analysis utilized chi(2) for trend, with p < 0.05 considered significant. RESULTS: 19,090 women were admitted in labor at term during the study period and fulfilled the study inclusion criteria and had amniotic fluid evaluation available. The appearance of meconium or worsening in thickness of meconium during labor was associated with higher rates of Apgar scores <7 at 5 min (clear AF on admission and at delivery 0.6%; light or thick meconium on admission and no change at delivery 0.8%; clear AF on admission and light or thick meconium at delivery 3.2%, and light meconium on admission and thick meconium at delivery 2.5%; p < 0.001) and umbilical artery pH <7.10 (the respective rates in the four groups were 1.7, 1.8, 3.6, and 3.8%; p < 0.001). CONCLUSION: The appearance or thickening of meconium during labor has a greater predictive ability for depressed neonates than the presence of meconium on admission.

Adult↗