Search PubMed⌕ Search

Biomedical subjects

Alban Denys

Publications and source records attributed to Alban Denys.

39 records · Page 3Linked to original sources

Detection of low-contrast objects: experimental comparison of single- and multi-detector row CT with a phantom.

PURPOSE: To compare single-detector row computed tomography (CT) and multi-detector row CT by using an experimental phantom containing a contrast-detail modulus for detection of low-contrast structures to optimize acquisition protocols. MATERIALS AND METHODS: The parameters milliampere seconds, reconstructed section thickness, and elementary collimation for multi-detector CT were varied for two pitches with single- and multi-detector CT. For objective assessment of image quality, contrast-to-noise ratio (CNR) was calculated for an 8-HU low-contrast 15-mm-diameter object. Subjective assessment of image quality was performed by means of visual detection of low-contrast objects of various sizes by four independent observers. For each acquisition protocol, the effective doses required to obtain the CNR thresholds allowing 100% detection of 5-, 7-, and 9-mm-diameter objects were compared at single- and multi-detector CT at comparable section sensitivity profile with analysis of variance. RESULTS: Significant correlation was found between CNR measurements and subjective object detection (r = 0.95, P <.05). CNRs of 1.0, 0.8, and 0.6 were required to detect 100% of the 5-, 7-, and 9-mm-diameter objects, respectively. For reconstructed section thickness of 5-10 mm, comparable x-ray doses were required with single- and multi-detector CT to detect objects. For reconstructed sections thinner than 5 mm, single- and multi-detector CT allowed detection of only the 7- and 9-mm-thick objects, but a higher x-ray dose was required for multi- than for single-detector CT (P <.05). CONCLUSION: Multi-detector CT is less effective than single-detector CT in detection of small low-contrast objects if sections thinner than 5 mm are used. Results for single- and multi-detector CT were similar for sections 5 mm or thicker.

Analysis of Variance↗

Magnetic resonance cholangiography features of biliary abnormalities due to cavernous transformation of the portal vein.

BACKGROUND: The aim of this retrospective and monocentric study was to describe the magnetic resonance cholangiography (MRC) features of biliary abnormalities related to extrahepatic obstruction of the portal vein (EHOPV). METHODS: From September 2001 to May 2003, MRC was performed in 10 consecutive patients who had a portal thrombosis. RESULTS: Biliary ductal pathology was demonstrated via MRC in nine patients. It consisted of stenoses, ductal narrowing or irregularities involving the common bile duct for three patients with extrahepatic portal vein thrombosis discovered a mean of 1.5 years ago, or involving both right and left intrahepatic bile ducts and common bile duct for six patients with extrahepatic portal vein thrombosis discovered a mean of 16.2 years ago. Dilation of intrahepatic bile ducts was seen for seven patients, four of them having cholestasis. For three patients with symptomatic cholestasis, direct cholangiography (DC) was performed and showed the same findings as MRC which nevertheless overestimated the degree of bile duct stenosis. CONCLUSIONS: MRC seems to constitute an accurate tool to investigate noninvasively patients with portal biliopathy.

Adult↗

Echinococcal cyst.

Explore the source record for details and available documents.

Adult↗